American Standard 1480.115, 1480.110 User Manual

Page 1
Installation
Instructions
SEVA
Centerset Lavatory Faucet with
SpeedConnect™ Drain
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
1480.110
1480.115
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time. *Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
Certified to comply with ANSI A112.18.1
M968305 REV. 1.1
1
INSTALL FAUCET
CAUTION
Turn off hot and cold water supplies before beginning.
Note: Putty is not required unless mounting surface is uneven.
Apply a bead of PUTTY along the edge of the underside of the BODY (1) if required.
Insert FAUCET (1) and CABLE CONNECTOR (2) through mounting holes of Sink or mounting surface.
Assemble LOCKNUTS (3) onto SHANKS (4) from under side of Sink. Hand tighten firmly.
Turn off water at
main supply.
Fig. B.
(HAND TIGHTEN)
Fig. A.
3
1
PUTTY
(IF REQUIRED)
Fig. A.
POP-UP CABLE
Tubing Cutter
4
Fig. B.
4
SINK OR
MOUNTING
SURFACE
3
2
1
2
Page 2
POP-UP DRAIN
2
Fig. A. Fig. B.
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY.
REMOVE FLANGE
3
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3).
Fig. B.
Fig. B.
1
3
2
Fig. A. Fig. B.
1
2
4
3
DRAIN BODY
4
INSTALL DRAIN FROM
4
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
FLANGE GASKET AND POP-UP KNOB
6
Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
TIGHTEN LOCKNUT
REAR OF SINK
4
DRAIN OUTLET
5
Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.
3
1
1
2
Fig. A. Fig. B.
DOWN
1
WHITE FOAM GASKET NOT VISIBLE
DRAIN FLANGE
M968305 REV. 1.1
2
Page 3
ATTACH CABLE CONNECTOR
7
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A.
Your new POP-UP DRAIN installation is now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. B.
Fig. A.
Fig. B.
1
CHECK OPERATION OF POP-UP
8
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
2
1-1/4” O.D.
1
2
Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
3/8” COMPRESSION
CONNECTION
3
1/2" PIPE
THREAD
2
FLEXIBLE
SUPPLIES
HOT
1
COUPLING NUT
3
3/8 O.D.
BULL-NOSE
RISERS
COMPRESSION NUT
FERRULE
COLD
M968305 REV. 1.1
Page 4
10
0
1
2
3
4
5
6
7
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.
Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
1
4
3
5
WASTE OUTLET
11
2
“P” TRAP
SERVICE
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Loosen SET SCREW (2) with 2.5mm hex wrench. Pull HANDLE (1) off valve stem. Pull off CAP (3). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (4). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
Replace ESCUTCHEON CAP (3), HANDLE (1), tighten HANDLE SCREW (2).
TEMPERATURE
SETTING NUMBERS
"B"
PRY RED RING FORWARD AND ROTATE CLOCKWISE
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD AND ROTATE COUNTER-
"A"
CLOCKWISE ONE CLICK
"B"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
"A"
4
1 2 3
2
"RED RING"- HOT LIMIT SAFETY STOP
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
4
M968305 REV. 1.1
Loading...