FALL 2016
2.18
www.americangranby.com
In the United States: Phone (800) 776-2266 Fax (800) 729-3299
In Canada: Phone (800) 268-7570 Fax (905) 629-3204
Yard Hydrants - Replacement Parts
5451NL Series Hydrant Replacement Parts
Part Number Item Number Description List Price
YRK1 Repair Kit (Items 1-8) $ 17.33
9175B 1 Plunger - BUNA N rubber/brass 6.37
9023B 2 Fulcrum Bolt - zinc plated steel 0.36
9023C 3 Fulcrum Nut - zinc plated steel 0.27
9023D 4 Links (set of 2) - zinc plated steel 2.38
9023E 5 Set Screw square head - zinc plated steel 0.47
9023A 6 Packing Nut - brass 3.18
29609G 7 Packing - graphite (2 - 1 old, 1 new style) 4.03
9023G 8 Connector - brass 5.79
2506K 9 Handle - painted cast iron 10.14
2222AHSS 10 Clevis Rod - SS NEW STYLE (for double bypass)11.77
2500K 11 Head only - painted cast iron 34.19
382914 13 Hose Adapter - brass 7.31
381504 14 Valve Body - brass 45.00
2575K Complete Head Assembly (Items 2-13) 56.18
STEEL ROD (use with double bypass valve 5451 Series)
TA7100099NS 54511 Rod (32.4”) 11.89
TA7100100NS 54512 Rod (44.4”) 15.46
TA7100101NS 54513 Rod (56.4”) 19.03
TA7100102NS 54514 Rod (68.4”) 20.60
TA7100103NS 54515 Rod (80.4”) 26.17
TA7100104NS 54516 Rod (92.4”) 29.74
TA7100105NS 54518 Rod (116.4) 36.89
®
5451NL HYDRANT ADJUSTMENT PROCEDURE
1. Turn water supply OFF.
2. Open hydrant to relieve pressure.
3. Loosen set screw. (Item 1)
4. Push brass rod down as far as it will go by hand to be sure the plunger is touching the seat.
5. Open handle (Item 2) approximately 30° from closed position.
6. Tighten set screw snugly.
7. Turn water supply ON.
8. Operate hydrant and make sure the hydrant is shutting off properly and flowing properly.
9. If hydrant still does not shut off, repeat steps 1 through 8.
10. Flow water through hydrant and then close completely to check for proper drainage by:
a) listening for water draining down pipe or
b) putting your hand over the hose connection to feel for a vacuum.
If hydrant does not drain, see step 11.
11. To clear drain hole blockage, close off hydrant spout by using hose cap or by attaching and kinking a hose. Open and close
hydrant to allow water pressure to clear blockage. Repeat step 10 to verify proper drainage. If hydrant still does not drain, repeat
steps 1 through 10 to fully uncover drain hole.
CAUTION: Do not try to make the shutoff adjustment in one attempt or you may overadjust and cause damage to the plunger and
rods. For this reason adjust in multiple small increments.
3/4” 5451NL Hydrant Flow Rates
PSI
10
15
20
25
30
35
40
45
50
GPM 15 20 25 30 35 40 45
45 GPM @ 50 PSI
42.5 GPM @ 45 PSI
37.5 GPM @ 35 PSI
40 GPM @ 40 PSI
35 GPM @ 30 PSI
32.5 GPM @ 25 PSI
29.3 GPM @ 20 PSI
25.7 GPM @ 15 PSI
20 GPM @ 10 PSI
NOTE: All 5451NL Series Hydrants are preset at factory.
There should be no need for any adjustment on initial installation.
Adjust only if water does not shut off or hydrant does not operate properly.