© Copyright 2010, American Fibertek, Inc. 0525JPM
Instruction Manual
MX-04 RX-04-13 MX-04S
RX-04 RX-04-13 RX-04S
RS422 Transceivers

INSTALLATION AND OPERATION INSTRUCTIONS
INTRODUCTION
Thank you for purchasing your American Fibertek 04 Series RS422 data transmitter. Please
take a few minutes to read these installation instructions in order to obtain the maximum
performance from this product.
FUNCTIONAL DESCRIPTION
The 04 Series operates as full duplex transmitter / receiver pair for the transmission of balanced
RS422 data signals over multimode or singlemode fiber optic cable depending upon the model
suffix. Two units are required to make a transmission pair.
MODEL NUMBERS
Model Number Wavelength Fiber
MX-04 850 nm Multimode 50 or 62.5u
RX-04 850 nm Multimode 50 or 62.5u
MX-04-13 1300 nm Multimode 50 or 62.5u
RX-04-13 1300 nm Multimode 50 or 62.5u
MX-04S 1300 nm Singlemode
RX-04S 1300 nm Singlemode
The transmitter converts a single data input into a AM modulated optical output. The standard
model operates at 850 nm, the -13 at 1300nm, both on 50 um or 62.5 um multimode fiber. The –
S model transmits at 1300 nm and is compatible with singlemode fiber. Refer to the data sheets
for detailed performance specifications.
This unit is contained in a compact and rugged aluminum housing with internal dc voltage
regulation. The detachable terminal block and LED indicator provide for easy installation and
monitoring dc power.
2

The MX is designed for mounting as a modular stand alone unit. For a rack mounted version
please see the RX.
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL
CODES.
Mount the unit to a secure surface using #8 (3mm) hardware in four places. See the drawing on
the next page for mounting dimensions. Be sure to allow sufficient room for the required
minimum bend radius of the fiber cable used.
POWER SOURCE
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY.
This unit requires a 12 VDC power source for proper operation. Current draw is approximately
150 mA maximum. In the USA and in Canada an American Fibertek PS-12 is supplied with this
unit. ANSI/NFPA 70 Class 2 wiring is recommended.
POWER CONNECTION
Power is supplied to the unit via a two pin terminal connector. See the customer assembly
drawing for proper location of the 12 volt dc input.
POWER
A green LED indicator monitors the internal dc voltage created within the MT-05B. Power status
associated with this LED is summarized below.
Power Indicator Power Status
Green Voltage Present
Off Voltage Not Present
DATA CONNECTION
The signal connector is a 5 pin detachable terminal block on the rack card (RX) and a 7 pin
combined power and data block on the module (MX) units. Connections should be made
according to the customer assembly drawing. The data input connections pass data to the fiber
optic transmitter Tx port for transmission on the fiber cable. Optical data on the Rx optical port is
present on the Data Output terminals.
FIBER CONNECTION
The fiber optic connection is made via a ST connector located on the side of the unit.
DIP SWITCHES
There are four DIP switches on the unit. Sw1 is used to boost the optical output by
approximately 3 dB. At low fiber loss, the use of this switch may introduce distortions at high
data rates. Only apply this switch with fiber loss of 6 dB or greater.
3

Sw2 determines the output logic state with no fiber connected. This switch must be set to the
same position on both sides of the link for proper operation. For a standard RS422 logic 1 with
no fiber connected, this switch should be Open. This switch may also be used to temporarily
turn on the optical transmitter with no data signal applied to aid in troubleshooting fiber cables or
verify optical output power of the transmitter.
Sw3 and SW4 are not used on these models.
LIFETIME WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of
defects in materials and workmanship. Defective products will be repaired or replaced at the
exclusive option of American Fibertek. A Return Material Authorization (RMA) number is
required to send the products back in case of return. All returns must be shipped prepaid. This
warranty is void if the products have been tampered with. This warranty shall be construed in
accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction
over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE,
EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN
THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for
contingent, consequential, or incidental damages. No agreement or understanding, expressed
or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in
writing, signed by a duly authorized officer of American Fibertek.
SERVICE INFORMATION
There are no user serviceable parts inside the unit.
In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc. Phone: (877) 234-7200
120 Belmont Drive Phone: (732) 302-0660
Somerset, NJ 08873 FAX (732) 302-0667
E-mail: techinfo@americanfibertek.com
4