81 / 82
SERIES
MULTIMODE
or
8
FEATURES:
• Form-C (Normally Open or Normally Closed) Dry
Contact Closure
• Latching Relays reduce power requirement
• User-Selectable feature maintains Contact Status
through Power-Cycle and Loss-of-Optical-Power.
• User Control to Reset all Contact Status
• Diagnostics: DC Power, Optical Presence, and
Channel Indicators
• High Density DB26 Data Connector with
Adaptor to screw terminal
SPECIFICATIONS:
Contact Closure:
Input ........................... .Switch Closure to Ground
Output ................................................Dry Contact
Response Time .............................................0.5 ms
Maximum Voltage ................. 40 VDC or Peak AC
Maximum Current ....................................0.5 amp
Connector .............................DB 26 with Adaptor
....................................... To Screw Terminal Block
Optical:
Wavelength ............................................1310 nm
Loss Budget (62.5/125µ) ...............................12 dB
Connector ...........................................................ST
Temperature (Operating):
-40°C to +75°C, non-condensing
Power Supply:
Module - 12 VDC (AFI Part #: PS-12D)
Power Consumption ..............................3 Watts
Rack Card (See AFI Part #: SR-20D/2)
Power Consumption ..............................3 Watts
Size (81 Series):
Module .......................................81⁄8” x 41⁄8” x 11⁄8”
Rack Card .........................................61⁄2” x 5” x 1”
Size (82 Series):
Module .......................................81⁄8” x 41⁄8” x 11⁄2”
Rack Card .......................................611⁄2” x 5” x 2”
Note: 82 Series Rack Card Requires Two Slots
ORDERING INFORMATION:
MT-81 = Module Transmitter- 8 Channel
RT-81 = Rack Card Transmitter- 8 Channel
MR-81 = Module Receiver- 8 Channel
RR-81 = Rack Card Receiver- 8 Channel
MT-82 = Module Transmitter-16 Channel
RT-82 = Rack Card Transmitter-16 Channel
MR-82 = Module Receiver-16 Channel
RR-82 = Rack Card Receiver-16 Channel
THE 81SL SERIES AND 82SL
SERIES ARE AVAILABLE FOR
SINGLEMODE APPLICATIONS
16
Eight or Sixteen Channel Contact Closure System
With Power Fail Safe Normally Open / Normally Closed Outputs
The American Fibertek 81 Series multiplexes 8 channels of dry latching
contact closure on one multimode fiber. The American Fibertek 82 Series
multiplexes 16 channels of dry latching contact closure on one multimode
fiber. A user-selectable feature allows the contact status to be maintained
unchanged or reset through power-cycle and loss-of-optical-power. A reset
button is available to clear all contact status to the default state. Individual
channel LEDs on the transmitter and the receiver units indicate the channel
status. These systems require no field adjustments at installation or additional
maintenance thereafter. Diagnostic indicators provide a quick visual indication
of system status. Equipment may be ordered as stand alone modules or rack
cards that are mounted in the SR-20D/2 or SR-20R/1 AFI Card Cages.
The
“Afinety” intelligent remote monitoring system is available on the Rack Card
product, please consult factory.
Contact 1 In:
Gnd
•
•
•
•
Contact 8 In:
Gnd
Contact 1 In:
Gnd
•
•
•
•
Contact 16 In:
Gnd
One
Multimode
Fiber
MT-81
or
RT-81
Transmitter
One
Multimode
Fiber
MT-82
or
RT-82
Transmitter
SEE WEBSITE FOR CURRENT RoHS PRODUCT AVAILABILITY
MR-81
or
RR-81
Receiver
MR-82
or
RR-82
Receiver
Contact 1 Out:
Norm Open
Common
Norm Closed
•
•
Contact 8 Out:
Norm Open
Common
Norm Closed
Contact 1 Out:
Norm Open
Common
Norm Closed
•
•
Contact 16 Out:
Norm Open
Common
Norm Closed
american fibertek inc. 120 Belmont Drive, Somerset, NJ, USA 08873-1204
Phone: 732-302-0660 FAX: 732-302-0667 Toll Free: 877-234-7200 Email: mail@americanfibertek.com
42