Functional Description
Installation
MX2
MX2
MX2
MX2 Copper Data
MXR2 Power Source
MXR2 Power Connection
MXR2 Fiber Data Connections
MXR2 Copper Data Connections
Thank you for purchasing your American Fibertek MX2 / MXR2
few minutes to read these installation instructions in order to obtain the maximum performance from
this product.
FUNCTIONAL DESCRIPTION
The
MX2 / MXR2 s
MX2-MM-FX-ST,
speeds of 10 Mb/s or 100 Mb/s on each of the copper
100 Mb/s. The MX2 / MXR2 series converts the electronic Ethernet input into an optical output using a
1300 nm wavelength source. The MX2 / MXR2 series also converts an optical Ethernet input signal
returning on a separate fiber into an electronic Ethernet output using a
The MX2-MM-FX-ST
maximum distance of 2 Km. The MX2-SM-FX-ST and
single
mode fiber with a maximum distance of 20 Km. Refer to the data sheets for detailed performance
specifications.
The
MX2 / MXR2
100Base
or MDIX interface. The MX2 / MXR2 series fiber port is set to 100Base-FX and is compatible with
IEEE802.3 100Base-FX standard products.
eries
combines
MXR2-MM-FX-ST, MX2-SM-FX-ST
and
MXR2-MM-FX-ST
series
-TX Ethernet data at full or half duplex.
is configured to auto negotiate the copper ports to
a single
fiber
units operate on 50 um or 62.5 um multimode fiber with a
Ethernet
, and
The auto negotiate feature also selects the proper MDI
MXR2-SM-FX-ST
ports.
MXR2
series
port with two copper Ethernet ports. The
The fiber port transmission speed is set at
media converter. Please take a
units allow transmission
130
0 nm wavelength detector.
-SM-FX-ST units operate on 9 um
either
10Base-T or
The availability of both a copper and a fiber port allows the
straight through Ethernet media converter, changing an electronic data signal to a fiber optic data
signal.
This unit is contained in a compact and rugged aluminum housing with internal dc voltage regulation.
The detachable terminal block, RJ45 Ethernet data
installation and monitoring of data and dc power. The
modula
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD
CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES.
Mount
on the next page for mounting dimensions. Be sure to allow sufficient room for the required minimum
bend radius of the fiber cable used.
MXR2 series units slide into any open slot in the MXRC-1 subrack. Use a small screwdriver to screw
the top and bottom fasteners into place.
r stand alone unit.
MX2 series units to a secure surface using #8 (3mm) hardware in four places. See the
The MXR2 series is designed for rack mounting in the MXRC-1 subrack
MX2 / MXR2 series product to be used as a
connector
, and LED indicators provide for easy
MX2 series
is designed for mounting as a
.
drawing
3
Page 4
FIBER
RXTX
FX LINK
SPD
1
LINK/ACT2LINK/ACT1
PWR
SPD
2
21
american fibertek
Media Converter MX2-MM-FX-SC
10/100BASE-TX To 100BASE-FX
DC IN 5V
MX2 Series
MX2 SERIES
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY.
MX2 series units require a +5VDC power source for proper operation. The DC input is diode protected.
In the USA and in Canada a 5 Volt DC power supply is supplied with this unit. The negative side of the
power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is reco
MX2 SERIES POWER CONNECTION
Power is supplied to the MX2 series units via a connection on the right side of the unit (refer to the
drawing
MX2 SERIES
The fiber o
of this unit is connected to the
MX2 SERIES
The UTP Ethernet input/output connections
maximum CAT
above).
POWER SOURCE
FIBER
ptic connections are made via ST
COPPER DATA C
5 wire length of 100 meters
DATA
CONNECTIONS
RX
port of the corresponding unit.
ONNECTIONS
is permitted
connectors located o
are
made via RJ45 plugs on the
.
n the
mmended.
left
side of the unit. The TX port
left
side of the unit. A
4
Page 5
FIBER
TX
RX
L
N
K
A
C
T
1
2
FX LINK
SPD
1
I
1
/
2
SPD
2
PWR
american fibertek
Media Converter MXR2-MM-FX-SC
10/100BASE-TX To 100BASE-FX
DC IN 5V
MXR2 Series
MXR
2 SERIES POWER SOURCE
Power to MXR2 series units is supplied by the subrack. Please refer to the MXRC-1 and MXRCPSinstructions for further details.
1
MXR
2 SERIES POWER CONNECTION
Power is supplied to the MXR2 series units via a four finger backplane connector. The MXR2 series
units can be inserted into the subrack or removed from the subrack with power applied to the
backplane.
MXR
The fiber optic connections are made via ST connectors located on the
this unit is connected to the RX port of the corresponding unit.
MXR
The UTP Ethernet input/output connections are made via RJ45 plugs on the
maximum CAT5 wire length of 100 meters is permitted.
2 SERIES FIBER
2 SERIES
COPPER DATA C
DATA
CONNECTIONS
ONNECTIONS
front
of the unit. The TX port of
fron
t of the unit. A
5
Page 6
MX2 / MXR2
The
MX2 / MXR2 series units
PWR
A green LED indicator monitors the presence of DC power into the unit. Power
this LED is summarized below.
PWR
FX Link
A
Green
associated with this LED is summarized below:
FX
Link Indicator
Solid
Flashing Green
Link/ACT1
A Green LED indicator monitors the copper connection and data flow on copper port #1.
associated with this LED is summarized below:
Link/ACT1 Indicator:
Solid Green
Flashing Green
STATUS INDICATORS
provide the following LED status indicators to aid in troubleshooting:
status associated with
Indicator
Green
Off
LED indicator monitors the fiber connection and data flow on the fiber p
Green
Off
Off
:
:
Input Power at Correct Level
Fiber Port Communicating in 100 Mbps Mode
Power
Check Input Power
Port 1 Communicating
Status
Fiber Port
Fiber Connected
Fiber Not Connected
Port 1 Status:
Port 1 Connected
No Data Flow
:
Status
:
ort. Fiber
Port
status
status
SPD1
A bi-
colored
associated with this LED is summarized below:
SPD1 Indicator:
Link/ACT2
A Green LED indicator monitors the copper connection and data flow on copper port #2. Port status
associated with this LED is summarized below:
Link/ACT2 Indicator:
Solid Green
Flashing Green
SPD2
A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #2. Data status
associated with this LED is summarized below:
SPD2 Indicator:
LED indicator monitors the speed of the data flow on RJ45 copper port #1. Data status
Green
Amber
Off
Off
Green
Amber
Off
P
Port 1 Connected and in 100 Mbps Mode
Port 2 Connected and in 100 Mbps Mode
Port 1 Connected and in 10 Mbps Mode
Port 2 Connected and in 10 Mbps Mode
Port 1 Status:
No Data Flow
Port 2 Status:
Port 2 Connected
ort 2 Communicating
No Data Flow
Port 2 Status:
No Data Flow
6
Page 7
WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery and for a period of five years thereafter
products delivered will be free of defects in materials and workmanship. Defective products will be
repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization
(RMA) number is required to send the products back in case of return. All returns must be ship
prepaid. This warranty is void if the products have been tampered with. This warranty shall be
construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive
jurisdiction over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET
FORTH IN THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for
contin
gent, consequential, or incidental damages. No agreement or understanding, expressed or
implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing,
signed by a duly authorized officer of American Fibertek.
the
ped
SE
RVICE INFORMATION
There are no user serviceable parts inside the unit.
In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc.
120 Belmont Drive
Somerset, NJ 0
8873
E-
mail:
techinfo@americanfibertek.com
Phone: (877) 234-7200
Phone: (732) 302-0660
FAX (732) 302-0667
7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.