American Fibertek MX-48-SX-ST, MX-48-LX-ST, MX-48-LX-SL-ST, MTX-48-LX-ST, MTX-48-LX-SL-ST User Manual

...
2012_4_1JPK
Instruction Manual
Series-48
Ethernet
Data Transceiver
INTRODUCTION
Thank you for purchasing your American Fibertek Series 48 Series Ethernet data transceiver. Please take a few minutes to read these installation instructions in order to obtain the maximum performance from this product.
FUNCTIONAL DESCRIPTION
The Series 48 Transceiver operates as a 3 port Ethernet switch / media converter. It has two copper ports that support triple speed (10/100/1000 BASE-T) Ethernet data and one fiber port that operates at 1000 Base-X over Singlemode or Multimode fiber optic cable. Auto MDI/MDIX operation on the copper ports eliminates the potential need for crossover cables. either 10/100/100 Base-T Ethernet data at full or half duplex The fiber port is available in the following options (see datasheets for more detail).
- 1 fiber or 2 fiber optical connections
- SX (short range), LX (long range) versions
- SC or ST optical connectors
- Multi-mode or Singlemode
- Modules or Rackcards.
INSTALLATION
THE INSTALLATION OF THIS UNIT SHOULD BE MADE BY A QUALIFIED SERVICE PERSON(S) AND MUST CONFORM TO ALL LOCAL CODES.
Mount the unit to a secure surface using #8 (3mm) hardware in four places. See the drawing on the next page for mounting dimensions. Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used.
POWER SOURCE
This module unit requires a +12VDC power source for proper operation. The DC input is diode protected. In the USA and in Canada an American Fibertek PS-12 is supplied with this unit. The negative side of the power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended. Power is supplied to the unit via a two pin terminal connector. Follow label on unit for proper orientation of +12 volt dc and ground.
The rackcard is powered from a subrack. Refer to the SR-20 and PSR-2 instructions for further details.
FIBER CONNECTION
The fiber optic connection is made via an SC or ST optical connector.
ETHERNET INPUT / OUTPUT CONNECTIONS
The UTP Ethernet input/output connection is made via a RJ45 plug. For optimum performance the shortest length of UTP wire practical should be used. Ethernet specifications permit a maximum CAT5 wire length of 100 meters.
The Series 48 is configured to auto negotiate
2