American Fibertek MT-984C-SL User Manual

Page 1
10/30/2012 JPK
Instruction Manual
MT-984C-SL
Eight Channel Digital Transmitter
With RS485, RS-422, RS232 or
Page 2
Table of Contents
Functional Description................................................................................. 3
Installation ................................................................................................... 3
Power Source.............................................................................................. 3
Power Connection ....................................................................................... 3
Fiber Connection ......................................................................................... 3
Video Input Connections ............................................................................. 4
Data Input / Output Connections ................................................................. 4
Typical System Data Connections............................................................... 5
Data Configuration....................................................................................... 5
MT-984C-SL Status LED Indicators ............................................................ 5
Warranty and Service Information............................................................... 6
2
Page 3
INSTALLATION AND OPERATION INSTRUCTIONS
INTRODUCTION
Thank you for purchasing your American Fibertek MT-984C-SL singlemode eight channel digital video transmitter with RS485, RS422, RS232 or Manchester data. Please take a few minutes to read these installation instructions in order to obtain the maximum performance from this product.
FUNCTIONAL DESCRIPTION
The MT-984C-SL operates as half of a transmitter / receiver pair for the transmission of eight channels of high performance 10 bit digital NTSC, PAL, RS170, or RS343 video signals. The MT-984C-SL also supports one bi-directional RS485, RS422, RS232 or a return Manchester data channel. The RS485 channel may be configured for 2-wire (half duplex) or 4-wire (full duplex) operation The MT-984C-SL is designed to operate with MR-984C-SL or RR-984C-SL video receiver with bi-directional data over one singlemode fiber optic cable. LED indicators provide for easy monitoring of video, data, and optical power.
The MT-984C-SL multiplexes eight video input signals along with one data signal into a high speed serial data stream. This serial data stream modulates a laser at 1310 nm wavelength. The MT-984C-SL also detects and demultiplexes a return optical serial data stream containing one data signal at 1550 nm wavelength. Refer to the data sheets for detailed performance specifications.
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES.
POWER SOURCE
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY. This unit requires a +12VDC power source with a current rating of 1.25 amps for proper operation. The
DC input is diode protected. The negative side of the power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended.
POWER CONNECTION
Power is supplied to the unit via a two pin terminal connector on the right side of the unit. Follow the label on unit for proper orientation of +12 volt dc and ground.
FIBER CONNECTION
The fiber optic connection is made via an FC/PC singlemode optical connector on the MT-984C-SL.
3
Page 4
VIDEO INPUT CONNECTIONS
The video input connections are made via BNC connectors on the unit. The video input should be connected to an appropriate 75 baseband video source such as a camera or a video recorder output. For optimum performance the video cables should be the shortest length of coax practical.
DATA INPUT / OUTPUT CONNECTIONS
Data input and output connections are made via a terminal block on the unit. Follow the drawings below for proper orientation of input and output connections. Please note that the far left pin on each connection drawing corresponds with the far left pin on the terminal block. For example RS485 DATA IN + is pin 5 as shown above and on the label.
4
Page 5
TYPICAL SYSTEM DATA CONNECTIONS
The RS422 or RS485 four wire interconnection between the MT-984C-SL and the copper device to which it is attached is based on industry standard EIA terminology for the transmission of electronic data signals. Using this terminology, the driver of an electronic signal is labeled TX or Data Out. Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard, the TX or Data Out of the copper device is connected to the RX or Data In of the MT-984C-SL. The plus terminal of the copper device is connected to the plus terminal of the MT-984C-SL and the minus is connected to the minus. The reverse flow of data from the MT-984C-SL to the copper device follows the same pattern. Not all manufactures follow standard EIA terminology. Consult the installation instructions for your copper device if you are unsure which two wires are the drive (data out) wires and which two wires are the received (data in) wires.
DATA CONFIGURATION
The MT-984C-SL is factory shipped with the data channel configured in the 4-wire RS485 mode.
See table below for a summary of switch settings. Data Switch Off=Up On=Down
1 2 3 4 5 Off Off Off Off Off RS485-4W/Manchester On Off On Off Off RS485-2W Off On Off On Off RS422 On On On On Off RS 232
MT-984C-SL STATUS INDICATORS
The MT-984C-SL transmitter provides the following LED status indicators to aid in installation and troubleshooting:
DATA TX
A green LED indicator is provided to monitor input data from the electrical interface, through the MT­984C-SL, and out onto the fiber. The intensity of this indicator will vary with input data patterns. However, in typical applications it will cycle on and off as data is transmitted. Data status associated with this LED is summarized below.
Data TX LED Data Status
Green Data Flow Present
Off Data Flow Not Detected
DATA RX
A green LED indicator is provided to monitor the data coming in from the fiber, through the MT-984C­SL, and out onto the electrical interface. The intensity of this indicator will vary with input data patterns. However, in typical applications it will cycle on and off as data is received. Data status associated with this LED is summarized below.
Data RX LED Data Status
Green Data Flow Present
Off Data Flow Not Detected
5
Page 6
VIDEO 1 THROUGH VIDEO 8
A bi-color LED indicator is provided for each of the eight video inputs to the MT-984C-SL. DC power and video status associated with each of these LED’s are summarized below.
Video Presence LED DC Power Status Video Status
Green On Proper Input Video /DC Power Present
Red On Input Video Not Detected/DC Power Present
Off Off Check Power Supply
OLI
A bi-color LED indicator monitors the optical input power that is being received into the MT-984C-SL from either the MR-984C-SL, or the RR-984C-SL. DC power and optical input status associated with this LED are summarized below.
Optical Level Indicator DC Power Status Optical Status
Green On Proper Optical Input/DC Power Present
Red On Optical Input Not Detected/DC Power Present
Off Off Check Power Supply
LIFETIME WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return. All returns must be shipped prepaid. This warranty is void if the products have been tampered with. This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract. EXCEPT FOR THE
FOREGOING WARRANTY, THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT. In any event, American Fibertek will
not be responsible or liable for contingent, consequential, or incidental damages. No agreement or understanding, expressed or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing, signed by a duly authorized officer of American Fibertek.
SERVICE INFORMATION
There are no user serviceable parts inside the unit. In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc. Phone: (877) 234-7200 120 Belmont Drive Phone: (732) 302-0660 Somerset, NJ 08873 FAX (732) 302-0667
E-mail: techinfo@americanfibertek.com
6