American Fibertek MTX-82B-SL, MRX-82B-SL, RRX-82B-SL Specsheet

8 CHANNEL BI-DIRECTIONAL CONTACT CLOSURE SYSTEM
Features:
(Normally Open or Normally Closed) Dry Contact Closure
Latching Relays reduce power
requirement
Maintains Contact Status through
Power-Cycle and Loss-of-Optical-Power.
User Control to Reset all Contact Status Diagnostics: Power, Optical Presence
and Channel Indicators
High Density DB26 Data Connector with
Adaptor to screw terminal
Specifications: Data:
Contact Closure Rating...............0.5A Max.
40 Volt DC or Peak AC Per Channel
Response Time...................................5 ms
Connector .....................DB26 with Adaptor
to Screw Terminal
Optical:
Wavelength..........................1310/1550 nm
Loss Budget (9/125µ).........................21 dB
Connector ........................................ FC/PC
Temperature (Operating)
-40°C to +75°C, non-condensing
Power Supply:
Module – 12 VDC (AFI Part # PS-12+) Rack Card – AFI SR 20/2
Size:
Module ...........................81/8” x 41/8” x 1.5”
Rack Card 6½” x 5” x2”
Product Ordering Information:
MTX = Module Transmitter–Signal Source MRX = Module Receiver–Signal Receive RTX = Rack Card Transmitter-Signal Source RRX = Rack Card Receiver–Signal Receive
Example: MTX-82B-SL to RRX-82B-SL
9/24/2012 JPM
82B-SL
SERIES
SINGLEMODE
Photo of another product which has the same packaging.
The American Fibertek 82B-SL Series multiplexes 16 total channels (8 in each direction) of dry latching contact closure on one singlemode fiber. Individual channel LEDs on the transmitter and the receiver units indic ate the channel status.
The contact output relays are latching which maintain their states when either optical power is removed (fiber disconnected) or the fiber modules lose DC power. A reset button is available to clear all contact status to the default state.
These systems require no field adjustments at installation or additional maintenance thereafter. Diagnostic indicators provide a qu ick visual i ndication of system status.
Equipment may be ordered as stand alone modules or rack cards that are mounted in the SR-20/2 or SR20H/2(redundant power supply) AFI Card Cage.
CONTACT
INPUTS
Channels 1 to 8
CONTACT OUTPUTS
Channels 9 to 16
MTX-82B-SL
or
RTX-82B-SL
ONE
SINGLEMODE
FIBER
MRX-82B-SL
or
RRX-82B-SL
CONTACT OUTPUTS
Channels 1 to 8
CONTACT
INPUTS
Channels 9 to 16
Loading...