American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH
INSTALLATION INSTRUCTIONS
CORVUS MEDIUM (CVM)
WARNING
!
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
WARNING
!
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
CAUTION
!
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION,
CONSULT LOCAL CODE AUTHORITY
OPENING & CLOSING THE UNIT:OPENING & CLOSING THE UNIT:
11.. TO OPEN THE FIXTURE, LOCATE THE LATCH AT THE FRONTTO OPEN THE FIXTURE, LOCATE THE LATCH AT THE FRONT
AND FLIP IT TOWARDS THE FRONT. (SEE FIGURE 1.) AND FLIP IT TOWARDS THE FRONT. (SEE FIGURE 1.)
OPEN THE HOOD.OPEN THE HOOD.
2. 2.
3. SECURE THE HOOD ON ITS OPEN POSITION USING THE ROD.3. SECURE THE HOOD ON ITS OPEN POSITION USING THE ROD.
(SEE FIGURE 2.)(SEE FIGURE 2.)
4. TO CLOSE THE FIXTURE, SIMPLY 4. TO CLOSE THE FIXTURE, SIMPLY UN-SECURE THE ROD AND UN-SECURE THE ROD AND
CLOSE THE CLOSE THE
PUSHING IT TOWARDS THE BACK UNTIL IT ENGAGES. PUSHING IT TOWARDS THE BACK UNTIL IT ENGAGES.
(SEE FIGURE 3.) (SEE FIGURE 3.)
HOOD AND RE-POSITION THE LATCH ON ITS PLACEHOOD AND RE-POSITION THE LATCH ON ITS PLACE
LATCHLATCH
FIGURE 1 FIGURE 1
CLOSED HOOD - STREET SIDE VIEWCLOSED HOOD - STREET SIDE VIEW
RODROD
FIGURE 2 FIGURE 2
OPEN HOOD - TOP VIEWOPEN HOOD - TOP VIEW
POWERPAD REMOVAL & INSTALLATION:POWERPAD REMOVAL & INSTALLATION:
1. OPEN THE UNIT. (SEE “OPENING AND CLOSING THE UNIT”1. OPEN THE UNIT. (SEE “OPENING AND CLOSING THE UNIT”
ABOVE.) ABOVE.)
2. UNSCREW THE FOUR SCREWS ATTACHING THE POWER PAD2. UNSCREW THE FOUR SCREWS ATTACHING THE POWER PAD
TO THE UNIT, TOTALLY DISENGAGING THEM FROM THE TO THE UNIT, TOTALLY DISENGAGING THEM FROM THE
CASTING. CASTING.
3. REMOVE THE SOCKET HOLDER (SEE LAMP INSTALLATION 3. REMOVE THE SOCKET HOLDER (SEE LAMP INSTALLATION
INSTRUCTIONS) GRIPPING THE BRACKET, REMOVE THE INSTRUCTIONS) GRIPPING THE BRACKET, REMOVE THE
POWER PAD FROM THE UNIT, DISCONNECTING THE WIRING POWER PAD FROM THE UNIT, DISCONNECTING THE WIRING
BY USE OF THE QUICK DISCONNECT. BY USE OF THE QUICK DISCONNECT.
4. TO REINSTALL THE POWER PAD REPEAT THE STEPS ABOVE4. TO REINSTALL THE POWER PAD REPEAT THE STEPS ABOVE
IN REVERSE ORDER. IN REVERSE ORDER.
NOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHEDNOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHED
AGAINST THE CASTING DURING RE-INSTALLATION OF THE AGAINST THE CASTING DURING RE-INSTALLATION OF THE
POWER PAD.POWER PAD.
RODROD
FIGURE 3FIGURE 3
DRAWING NO. A68045 REV C (FRONT)
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-68045

American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
CORVUS MEDIUM (CVM)CORVUS MEDIUM (CVM)
MOUNTING:MOUNTING:
NOTE: THIS UNIT WILL ACCEPT SIDE MOUNTING POLESNOTE: THIS UNIT WILL ACCEPT SIDE MOUNTING POLES
WITH AN EXTERIOR DIAMETER BETWEEN 1 5/8” AND 2.375”.WITH AN EXTERIOR DIAMETER BETWEEN 1 5/8” AND 2.375”.
THIS UNIT WILL ACCEPT VERTICAL MOUNTING POLETHIS UNIT WILL ACCEPT VERTICAL MOUNTING POLE
WITH AN EXTERIOR DIAMETER BETWEEN 2.375” AND 3.0” WITH AN EXTERIOR DIAMETER BETWEEN 2.375” AND 3.0”
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE MOUNTING BASE OF SUPPLY LEADS THROUGH THE MOUNTING BASE OF
THE UNIT. THE UNIT.
CAUTION
!
VERTICAL MOUNTINGVERTICAL MOUNTING
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
0°0°
LAMP INSTALLATION:LAMP INSTALLATION:
11. OPEN THE UNIT. . OPEN THE UNIT.
2. 2. REMOVEREMOVE SOCKET SOCKET HOLDER CLAMPS HOLDER CLAMPS..
3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY
DEPRESS AND LOAD THE CENTER CONTACT OF THE DEPRESS AND LOAD THE CENTER CONTACT OF THE
SOCKET. SOCKET.
cont. cont.
NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEEDNOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEED
THE SUPPLIED PRE-WIRE THROUGH THE MOUNTING BASETHE SUPPLIED PRE-WIRE THROUGH THE MOUNTING BASE
AND DOWN THE POLE. AND DOWN THE POLE.
2. ORIENT THE UNIT SO THAT THE CLOSURE LATCH2. ORIENT THE UNIT SO THAT THE CLOSURE LATCH
IS TO THE STREET SIDE. IS TO THE STREET SIDE.
3. TIGHTEN THE TWO MOUNTING SET SCREWS.3. TIGHTEN THE TWO MOUNTING SET SCREWS.
HORIZONTAL MOUNTINGHORIZONTAL MOUNTING
5°5°
NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.
4. PLACE SOCKET HOLDER IN PLACE AND SECURE CLAMPS.4. PLACE SOCKET HOLDER IN PLACE AND SECURE CLAMPS.
5. CLOSE THE UNIT.5. CLOSE THE UNIT.
6. ENERGIZE AND VERIFY OPERATION.6. ENERGIZE AND VERIFY OPERATION.
IF LAMP IS MARKED IT CONTAINS MERCURY.IF LAMP IS MARKED IT CONTAINS MERCURY.
FOLLOW DISPOSAL LAWS. SEE WWW.LAMPRECYCLE.ORGFOLLOW DISPOSAL LAWS. SEE WWW.LAMPRECYCLE.ORG
Hg
WIRING:WIRING:
NNOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT ISOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
SUPPLIED WITH PRE-WIRE.SUPPLIED WITH PRE-WIRE.
1. OPEN THE UNIT.1. OPEN THE UNIT.
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
INSIDE OF THE HOOD. INSIDE OF THE HOOD.
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK. THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
TERMINAL BLOCK, AND TIGHTENING THE SCREW TERMINAL BLOCK, AND TIGHTENING THE SCREW
SECURELY. SECURELY.
5. CLOSE THE UNIT.5. CLOSE THE UNIT.
PPHHOOTTOOCCOONNTTRROOLL::
NNOOTTEE:: OONN TTHHEE CCVVM M NNOO TTOOOOLLIINNGG IISS NNEECCEESSSSAARRYY FFOORR TTHHEE
PPHHOOTTOOCCOONNTTRROOLL INSTALLATION OR ADJUSTMENT. INSTALLATION OR ADJUSTMENT.
11.. IINNSSEERRTT TTHHEE PPHHOOTTOOCCOONNTTRROOLL IINNTTOO TTHHEE RREECCEEPPTTAACCLLEE..
22.. TTUURRNN TTHHEE PPHHOOTTOOCCOONNTTRROOLL TTOOWWAARRDD NNOORRTTHH BBYY LLIIFFTTIINNGG
A ANNDD TTUURRNNIINNGG SSIMULTANEOUSLY UNTIL IT IS FACINGIMULTANEOUSLY UNTIL IT IS FACING
NORTH. NORTH.
VERTICAL MOUNTVERTICAL MOUNT
DRAWING NO. A68045 REV C (BACK)
HORIZONTAL MOUNTHORIZONTAL MOUNT
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-68045