Model Numbers
RJ860AP . . . . . . . . . . . . . . . . . . . . .Indoor, ten-position RS-422 J-Box,
120 VAC
RJ860AP-1 . . . . . . . . . . . . . . . . . . . .Indoor, ten-position RS-422 J-Box,
230 VAC
Electrical
Input Voltage . . . . . . . . . . . . . . . . .120V or 230V, 50/60 Hz
Input Current . . . . . . . . . . . . . . . .6.0 A
Max Operational Limits . . . . . . .90 to 132 VAC or 180 to 265 VAC, 50/60 Hz
Output Per Position . . . . . . . . . . .28 VAC, 2.0 A, Class 2 LPS
Surge Protection . . . . . . . . . . . . . .TVS, line conditioning
Operational
Diagnostic LEDs . . . . . . . . . . . . . .RS-422 communication
Mechanical
Environment . . . . . . . . . . . . . . . . .Indoor
Wall Mounting Options . . . . . . .Concrete, wood, sheet rock
Dimensions (H x W x D) . . . . . . .514 x 310 x 150 mm
(20.25 x 12.25 x 6 in)
Unit Weight . . . . . . . . . . . . . . . . . .16.3 kg (36 lbs)
Shipping Weight . . . . . . . . . . . . . .21.8 kg (48 lbs)
Construction . . . . . . . . . . . . . . . . .Steel
Color . . . . . . . . . . . . . . . . . . . . . . . .Light gray
Cover Locks . . . . . . . . . . . . . . . . . .One captive screw
Cable Access . . . . . . . . . . . . . . . . . .Four knockouts provided for cable access
RS-422 Serial Communication Interface
Cable Distance
J-Box to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
Host to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
J-Box to Dome . . . . . . . . . . . . . .Limited by the length of the low-voltage
AC power cable
Maximum Loads . . . . . . . . . . . . . .10 daisy-chained
Cable Type . . . . . . . . . . . . . . . . . . .Two shielded twisted pair (STP), 22 AWG,
polarized
Surge Protection . . . . . . . . . . . . . .TVS, 6.2 V, 1 W, .73 A
Connectors
Host . . . . . . . . . . . . . . . . . . . . . . .Spring-loaded
Aux . . . . . . . . . . . . . . . . . . . . . . . .Spring-loaded
Dome . . . . . . . . . . . . . . . . . . . . . .Cinch Jones
Environmental
Operating Temperature . . . . . . . .-10° to 50° C (14° to 122° F)
Storage Temperature . . . . . . . . . .-40° to 70° C (-40° to 158° F)
Relative Humidity . . . . . . . . . . . . .0 to 95% RH (non-condensing)
Regulatory
Emissions . . . . . . . . . . . . . . . . . . . .FCC: 47 CFR, Part 15,
Subpart B Class A
CE: EN55022, Class B
CE: EN6100-3-2
CE: EN6100-3-3
AS/NZS 3548, Class A
CISPR22
ICES-003
Immunity . . . . . . . . . . . . . . . . . . . .CE: EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . . . .UL: UL1950
cUL: CSA 22.2, No. 950
CE: EN60950
IEC950
Compatibilities
SpeedDome Ultra Series Dome
SpeedDome Optima Series Dome
AMERICAN DYNAMICS RJ860AP SERIES TEN POSITION J-BOXES
VS291-02 01/03 L
©2003 Sensormatic Electronics Corporation
Product specifications and availability subject to change without notice.
Certain product names mentioned herein may be trade names and/or
registered trademarks of other companies.
Back side – Single sheet – Letter size – print b/w