American Dynamics RJ860AP Specsheet

The SpeedDome®Ultra/Optima ten-position
J-Boxes provide Class 2 LPS power and data
communications for up to ten SpeedDome
Series programmable domes. Each J-Box
and feeds that data to the dome.
The units contain diagnostic LEDs for RS-422
communication. Surge protection circuitry
within the J-Box arrests unexpected voltage
surges on exterior power and data lines to
protect interior equipment. The J-Boxes can be
surface-mounted to concrete, wood, or sheet
rock with supplied hardware.
RJ860AP Series
TEN POSITION J-BOX (RS-422)
Supports up to ten SpeedDome, SpeedDome Ultra and Optima domes
Meets Class 2 LPS power requirements
120 VAC or 230 VAC input versions available
Diagnostic LEDs mounted on PC board
Front cover can be secured with a captive screw
Surge protection
Hardware or line cord power connection
Front side – Single sheet – Letter size – print 4/c
Actual product may vary from photo
www.americandynamics.net
RJ860AP_VS293_L.qxd 2/19/04 3:53 PM Page 1
FEATURES
SPECIFICATIONS
Model Numbers
RJ860AP . . . . . . . . . . . . . . . . . . . . .Indoor, ten-position RS-422 J-Box,
120 VAC
RJ860AP-1 . . . . . . . . . . . . . . . . . . . .Indoor, ten-position RS-422 J-Box,
230 VAC
Electrical
Input Voltage . . . . . . . . . . . . . . . . .120V or 230V, 50/60 Hz
Input Current . . . . . . . . . . . . . . . .6.0 A
Max Operational Limits . . . . . . .90 to 132 VAC or 180 to 265 VAC, 50/60 Hz
Output Per Position . . . . . . . . . . .28 VAC, 2.0 A, Class 2 LPS
Surge Protection . . . . . . . . . . . . . .TVS, line conditioning
Operational
Diagnostic LEDs . . . . . . . . . . . . . .RS-422 communication
Mechanical
Environment . . . . . . . . . . . . . . . . .Indoor
Wall Mounting Options . . . . . . .Concrete, wood, sheet rock
Dimensions (H x W x D) . . . . . . .514 x 310 x 150 mm
(20.25 x 12.25 x 6 in)
Unit Weight . . . . . . . . . . . . . . . . . .16.3 kg (36 lbs)
Shipping Weight . . . . . . . . . . . . . .21.8 kg (48 lbs)
Construction . . . . . . . . . . . . . . . . .Steel
Color . . . . . . . . . . . . . . . . . . . . . . . .Light gray
Cover Locks . . . . . . . . . . . . . . . . . .One captive screw
Cable Access . . . . . . . . . . . . . . . . . .Four knockouts provided for cable access
RS-422 Serial Communication Interface
Cable Distance
J-Box to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
Host to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
J-Box to Dome . . . . . . . . . . . . . .Limited by the length of the low-voltage
AC power cable
Maximum Loads . . . . . . . . . . . . . .10 daisy-chained
Cable Type . . . . . . . . . . . . . . . . . . .Two shielded twisted pair (STP), 22 AWG,
polarized
Surge Protection . . . . . . . . . . . . . .TVS, 6.2 V, 1 W, .73 A
Connectors
Host . . . . . . . . . . . . . . . . . . . . . . .Spring-loaded
Aux . . . . . . . . . . . . . . . . . . . . . . . .Spring-loaded
Dome . . . . . . . . . . . . . . . . . . . . . .Cinch Jones
Environmental
Operating Temperature . . . . . . . .-10° to 50° C (14° to 122° F)
Storage Temperature . . . . . . . . . .-40° to 70° C (-40° to 158° F)
Relative Humidity . . . . . . . . . . . . .0 to 95% RH (non-condensing)
Regulatory
Emissions . . . . . . . . . . . . . . . . . . . .FCC: 47 CFR, Part 15,
Subpart B Class A CE: EN55022, Class B CE: EN6100-3-2 CE: EN6100-3-3 AS/NZS 3548, Class A CISPR22
ICES-003
Immunity . . . . . . . . . . . . . . . . . . . .CE: EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . . . .UL: UL1950
cUL: CSA 22.2, No. 950
CE: EN60950
IEC950
Compatibilities
SpeedDome Ultra Series Dome SpeedDome Optima Series Dome
AMERICAN DYNAMICS RJ860AP SERIES TEN POSITION J-BOXES
VS291-02 01/03 L
©2003 Sensormatic Electronics Corporation
Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
Back side – Single sheet – Letter size – print b/w
RJ860AP_VS293_L.qxd 2/19/04 3:53 PM Page 2