American Dynamics RJ6SN Specsheet

The six position J-Boxes provide Class 2 LPS power and data communications for up to six SpeedDome
®
Series programmable domes. Each J-Box receives data from the compatible controller and feeds that data to the domes.
The units contain an on/off power switch as well as diagnostic LEDs for host, aux, dome activity, noise, and power. Surge protection circuitry within the J-Box arrests unexpected voltage surges on exterior power and data lines to protect interior equipment. The J-Boxes can be surface­mounted to concrete, wood, or sheet rock with supplied hardware. They can also be mounted to a ceiling or to a pole with user-supplied hardware.
RJ6SN
SIX-POSITION SENSORNET J-BOX
Supports up to six SpeedDome, SpeedDome Ultra and Optima domes
Meets Class 2 LPS power requirements
Can be configured for either 120 VAC or 230 VAC input
Hardwire or line card power latch
Diagnostic LEDs
Quick-release lockable cover latch
Surge protection
On/off switch for field servicing
www.americandynamics.net
FEATURES
SPECIFICATIONS
Model Number
RJ6SN . . . . . . . . . . . . . . . . . . . . . . .Six-position SensorNet J-Box,
120 VAC/230 VAC Transformer primary jumpers and main line cord are field changeable to support either 120 VAC or 230 VAC.
Electrical
Input Voltage . . . . . . . . . . . . . . . . .100 to 120 VAC or 200 to 240 VAC,
50/60 Hz
Input Current . . . . . . . . . . . . . . . .1.6 A/0.8 A
Max Operational Limits . . . . . . .90 to 135 VAC or 180 to 265 VAC,
50/60 Hz
Output . . . . . . . . . . . . . . . . . . . . . . .28 VAC, 5 A max, Class 2 LPS
Power Line . . . . . . . . . . . . . . . . . . .TVS rated at 10 kA, 8/20 µsec impulse
rated gas tube
Operational
Diagnostic LEDs
SensorNet . . . . . . . . . . . . . . . . . .Host, aux, dome activity, noise, power
Power . . . . . . . . . . . . . . . . . . . . . . . .On/off power switch
Mechanical
Environment . . . . . . . . . . . . . . . . .Indoor
Wall Mounting Options . . . . . . .Concrete, wood, sheet rock
Dimensions (H x W x D) . . . . . . .320 x 210 x 160 mm
(12.60 x 8.27 x 6.30 in)
Unit Weight . . . . . . . . . . . . . . . . . .8.5 kg (18.7 lbs)
Shipping Weight . . . . . . . . . . . . . .10.9 kg (24 lbs)
Construction . . . . . . . . . . . . . . . . .Galvanized steel
Color . . . . . . . . . . . . . . . . . . . . . . . .Light gray
Cover Locks . . . . . . . . . . . . . . . . . .One quick-release lockable cover latch
Cable Access . . . . . . . . . . . . . . . . . .Three knockouts provided for cable access
SensorNet Serial Communication Interface
Cable Distance
J-Box to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
Host to J-Box . . . . . . . . . . . . . . .1 km (3000 ft)
J-Box to Dome . . . . . . . . . . . . . .Limited by the length of the low-voltage
AC power cable
Maximum Loads . . . . . . . . . . . . . .32/node
Cable Type . . . . . . . . . . . . . . . . . . .Single unshielded twisted pair (UTP),
22 AWG, non-polarized
Surge Protection . . . . . . . . . . . . . .Isolation transformer coupled, 2000 Vrms,
10 kA, 8/20 µsec impulse rated gas tubes,
TVS rated at 1 watt Host, Aux and
Dome Connectors . . . . . . . . . . . .Eurostyle plug
Environmental
Operating Temperature . . . . . . . .0°to 50° C (32° to 122°F)
Storage Temperature . . . . . . . . . .-40° to 70° C (-40°to 158° F)
Relative Humidity . . . . . . . . . . . . .0 to 95% RH (non-condensing)
Regulatory
Emissions . . . . . . . . . . . . . . . . . . . .FCC: 47 CFR, Part 15,
Subpart B Class A CE: EN55022, Class B CE: EN6100-3-2 CE: EN6100-3-3 AS/NZS 3548, Class A CISPR22
ICES-003
Immunity . . . . . . . . . . . . . . . . . . . .CE: EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . . . .UL: UL1950
cUL: CSA 22.2, No. 950
CE: EN60950
IEC950
Compatibilities
SpeedDome Ultra Series Dome SpeedDome Optima Series Dome
AMERICAN DYNAMICS RJ6SN SIX-POSITION J-BOX
VS292-02 01/03 L
©2003 Sensormatic Electronics Corporation
Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.