SpeedDome® Ultra
PRESSURIZED OUTDOOR DOME HOUSING
The SpeedDome Ultra pressurized outdoor
housing allows the SpeedDome Ultra dome to
be installed in virtually any hostile environment.
The housing is pressurized, temperature
controlled and weatherproof, protecting the
dome from a wide range of outside elements
such as moisture, dust and temperature
fluctuations. In extreme temperatures, the
housing’s built-in thermostat and heater
prevents ice from forming on the outside bubble.
The bubble assembly is affixed to the top via
nine screws.
Simply plug in the video cable, connect power
Durable engineered
•
plastic top, UV protected
IP67, NEMA 4x rated
•
Pressurized to 5 psi
•
Schrader valve
•
Pressure relief valve
•
Pendant, wall and corner
•
mount available
Heater and blower
•
st
Lo
•
d
andar
w pressure alarm
and data, and install any SpeedDome Ultra.
Diagnostic power and communications LEDs
confirm proper connection and aid in
troubleshooting. A choice of wall, pendant or
corner mounts accommodate the housing,
making it easy to install. The housing is
equipped with surge protection provided to all
video and external lines. The housing is supplied
with a choice of either clear or smoked bubble.
www.americandynamics.net
AMERICAN DYNAMICS SPEEDDOME®UL
TRA PRESSURIZED OUTDOOR DOME HOUSING
Model Numbers
RHODULP-01 . . . . . . . . . . . . . .Pressure Housing with Integrated I/O Board
and Clear Bubble (ƒ0)
RHODULP-02 . . . . . . . . . . . . . .Housing with Integrated I/O Board and
Smoked Bubble (ƒ1.0)
Electrical
Voltage . . . . . . . . . . . . . . . . . . . .24-28 VAC
Power . . . . . . . . . . . . . . . . . . . . . .52 watts
Power-On In-Rush Current . .2.5 A
Surge Protection
Video . . . . . . . . . . . . . . . . . . . . .Series resistor of 3.9 Ω; low-capacitance Zener
suppressor of 6.5 V, 1500 watts, 500 watts,
8/20 µsec impulse, 500 watts, 10 kA impulse
rated gas tube
Manchester/SensorNet . . . . .Isolation transformer coupled, 2000 Vrms;
PTC resettable fuse protects transformer;
TVS rated at 5.6 V, 40 A, 0.1 joules, 8/20 µsec
impulse, 500 watts, 10 kA impulse rated
gas tube
RS-422 . . . . . . . . . . . . . . . . . . . .Series resistors of 33 Ω; TVS rated at 5.6 V,
40 A, 0.1 joules, 8/20 µsec impulse, 500 watts,
10 kA impulse rated gas tube
Power Line . . . . . . . . . . . . . . .TVS rated at 60 V, 250 A, 1.5 joules, 8/20 µsec
impulse, 500 watts, 10 kA impulse rated
gas tube
Mechanical
Construction
Enclosure . . . . . . . . . . . . . . . . .Aluminum
Color . . . . . . . . . . . . . . . . . . . . . .White
Height . . . . . . . . . . . . . . . . . . . . .325 mm (12.8 in)
Diameter . . . . . . . . . . . . . . . . . . .409 mm (16.1 in)
Weight . . . . . . . . . . . . . . . . . . . . .3.63 kg (8.0 lbs)
Bubble . . . . . . . . . . . . . . . . . . . . .Acrylic
Maximum Distances From Power Source
Dome and housing to be connected to a Class 2 LPS, 24 VAC, 80 VA power
source (do not exceed maximum outdoor Class 2 ratings of 30 VAC, 100 VA).
Environmental
Weatherproof Standard . . . . .NEMA 4X/IP67
Temperature
Operating . . . . . . . . . . . . . . . . .-40° to 50° C (-40° to 122° F)
Humidity . . . . . . . . . . . . . . . . .0 to 95% RH (non-condensing)
Storage . . . . . . . . . . . . . . . . . . .-10° to 50° C (14° to 122° F)
Regulatory
Emissions . . . . . . . . . . . . . . . . . .FCC: 47 CFR Part 15, Subpart B Class A
CE: EN55022 Class B
CE: EN6100-6-1
ICES-003
Immunity . . . . . . . . . . . . . . . . . .CE: EN50130-4
Safety . . . . . . . . . . . . . . . . . . . . . .UL: UL2044
CE: EN60950
Accessories
WM20G . . . . . . . . . . . . . . . . . . .Aluminum gooseneck wall mount bracket
for RHODULP pressurized housings
ACA2 . . . . . . . . . . . . . . . . . . . . . .Aluminum corner mount bracket for
RHODULP pressurized housings, to be used
in conjunction with WM20G
APM3 . . . . . . . . . . . . . . . . . . . . . .Aluminum pole mount bracket for
RHODULP pressurized housings, to be used
in conjunction with WM20G
RHONKIT* . . . . . . . . . . . . . . . .Nitrogen recharge kit with hose, regulator
and tank. Tank holds sufficient gas for three
housings
RHONTANK* . . . . . . . . . . . . . .Nitrogen tank for use with RHONKIT or
equivalent. Tank holds sufficient gas for
three housings
RHONREG . . . . . . . . . . . . . . . .Hose and regulator kit for RHONTANK or
equivalent. For use when gas is to be sourced
locally
* Please check with your salesperson for recharge kit availability in your
geographic region.
Note: For proper performance, the dome housing must be pressurized
using 99.998% dry nitrogen.
Connectors (on integrated I/O board)
Manchester/SensorNet . . . . . .Two-position 3.5 mm Euro-style terminal
block
RS-422 . . . . . . . . . . . . . . . . . . . . .Four-position 3.5 mm Euro-style terminal
block
Video Output . . . . . . . . . . . . . .Female BNC
I/O Connector . . . . . . . . . . . . . .Spring contact gold fingers for mate with
SpeedDome Ultra housing/ey
w pressure alarm pre-wired (alarm inputs
. . . . . . . . . . . . . . . . . . . . . .
Alarm
Product specifications and availability subject to
change without notice.
Certain product names mentioned her
names and/or registered trademarks of other companies.
Lo
2-4 are not used)
ein may be trade
eball assemblies
©2005 Sensormatic Electronics Corporation
VS412-02 08/05 A4