American Dynamics RCSN422 Installation

Page 1
SensorNet to RS-422 Code Converter
Rack Mount
Installation Guide
e
n
s
o
r
N
e
t
t
o
R
4
2
2
C
o
n
v
e
r
t
e
r
RCSN422
Overview
The RCSN422 code converter converts SensorNet to RS-422. The converter supports the ADTT16E controller and MegaPower LT matrix switcher.
Installation
The converter can be placed on a tabletop, or installed in a rack, under a shelf, or on a wall.
S
e
n
s
o
r
N
e
t
t
o
R
S
4
2
2
C
o
n
v
e
r
t
e
r
M3x8 Screws (supplied)
Under-Shelf Mount
S
e
n
s
o
r
N
e
t
t
o
R
S
4
2
2
C
o
n
v
e
r
t
e
r
M3x8 Screws (supplied)
Parts Supplied
Wall Mount
Install Kit 0351-1635-01, which includes:
Mounting Bracket (2)
Screw, PHP, M3x8 (4)
Connector, RS-422, 3.5mm, 1x5 (7)
Connector, Power, 5.06mm, 1x3 (1)
Connector, RS-485, 5.06mm, 1x2 (1)
Cable, 16.5ft, 24Vac, 3 Cond., 18AWG (1)
M3x8 Screws (supplied)
© 2005 Sensormatic Electronics Corporation
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
1 of 7
Page 2
Indicators, Connections, and Settings
Front
µP 485 422
~
Rear
Pin 1
Front Panel (left to right)
Reset Recessed button used to reset the
code converter (use a paperclip).
µP Green LED blinks when processor in
485 Green LED shows SensorNet activity:
422 Green LED blinks to indicate that at
Green LED indicates 24Vac is applied.
code converter is operating.
Off indicates no activity
On indicates network is active with
valid data
Blinks when unit is answering polls.
Red, noise LED lights for 0.5s. Usually indicates invalid frame lengths or noise on the line.
least one RS-422 device is responding to polls.
Blinks twice when unit is reset or powered up
First blink indicates a successful ROM check; second blink indicates a successful RAM check
LED illuminates continuously when either check fails, stopping the test
Remains illuminated during program load.
Pin 1
Rear Panel (left to right)
422 Ports (Seven)
485 Port Receives a SensorNet (RS-485) cable
Terminate Switch
Address Switches
x10
24Vac Connector
Each port receives a RS-422 cable from a dome camera or RJ-860AP J-Box. An RS-422 line test switch and LED are adjacent to each port.
LED
Pinouts: Pin 1 – RXHI+ Pin 2 – RXLO­Pin 3 – TXHI+ Pin 4 – TXLO­Pin 5 – Ground
from the ADTT16E or MegaPower LT.
Set to left (terminated) Set to right (unterminated)
Use address 00 for the loopback test (see page 4).
x1
If MiniDomes are used, set the device address to 16. If SpeedDomes are used, set the device address to 32.
Receives 24Vac from a transformer.
Pinouts: Pin 1 – AC or common Pin 2 – Ground Pin 3 – 24Vac
Test Switch
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
2 of 7
Page 3
WARNING! EU power requirements: This product runs on 24Vac. In
Specifications
Electrical
Primary input .............. 110-120, 200-240Vac @ 50-60Hz
RS-422 Converter Input from Transformer
Primary input ...................................... 24Vac @ 50-60Hz
Power consumption ......................................... 20W max.
Allowable line drop.................................................150ms
Environmental
Operating temperature:............. 0° to 50°C (32° to 122°F)
Relative humidity: ....................0 to 90% non-condensing
Mechanical
Height ...................................................... 38.5mm (1.5in)
Width .......................................................435mm (17.1in)
Depth ........................................................ 129mm (5.1in)
Weight ......................................................1.5kg (3.3 lbs.)
Declarations
Regulatory Compliance
REG ID: RS422
EMC........................................................47 CFR, Part 15
ICES-003 EN55022 (CE)
Immunity ................................................ EN50082-1 (CE)
Safety ......................................................... UL 1950 (UL)
cUL CSA C22.2 No. 950 EN 60950 (CE)
FCC COMPLIANCE: This equipment complies with Part 15 of the FCC rules for intentional radiators and Class A digital devices when installed and used in accordance with the instruction manual. Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area. This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications, a situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition.
WARNING! North America power requirements: In North America, this device is intended to be supplied from a Class 2 power supply. This installation should be made by a qualified service person and should conform to all local codes.
the EU, it is intended to be powered from a Limited Power Source. A limited power source is a certified source of SELV, and if inherently limited, with 8 amps maximum output current, and a maximum of 100VA available; or if not inherently limited, fused with a maximum value of 3.3 Amps, meeting section 2.11 of IEC950, and a maximum of 250VA available. The power supply can be obtained through American Dynamics or through another source where the provider can furnish the verification. This is required to assure electrical safety in the product.
Stromanforderungen in der EU: Dieses Produkt wird mit 24 V Wechselstrom betrieben. In der EU ist es für den Betrieb durch eine begrenzte Stromquelle vorgesehen. Eine begrenzte Stromquelle ist eine zertifizierte SELV-Quelle (Schutzkleinspannung), bei inhärenter Begrenzung mit einem maximalen Ausgangsstrom von 8 A und 100 VA maximaler Verfügbarkeit, bei nicht inhärenter Begrenzung mit einer maximalen Sicherung von 3,3 A gemäß Abschnitt 2.11 der IEC950 und 250 VA maximaler Verfügbarkeit. Das Netzteil kann über American Dynamics oder eine andere Quelle bezogen werden, wobei der Anbieter den Nachweis der Konformität bereitstellen sollte. Dies ist zur Gewährleistung der elektrischen Sicherheit des Produktes erforderlich.
Other Declarations
Thank you for using American Dynamics products. We support our products through an extensive and worldwide network of dealers. The dealer, through whom you originally purchased this product, is your point of contact if you have a need for service or support. Our dealers are fully empowered to provide the very best in customer service and support. Dealers should contact American Dynamics at (800) 507-6268 or (561) 912-6259 or on the web at www.americandynamics.net.
WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose.
NOTICE: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: American Dynamics and Sensormatic are trademarks or registered trademarks of Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.
COPYRIGHT: Under copyright laws, the contents of this manual may not be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of Sensormatic Electronics.
MDR 8/05
www.americandynamics.net
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
3 of 7
Page 4
Troubleshooting
The converter's front-panel LEDs indicate when activity occurs during operation. They also identify many errors that could occur:
422 LED on steadily
(noise) LED
flashes randomly
485 LED off No SensorNet protocol detected.
LED Off
µP LED flashes rapidly
ROM checksum or RAM read/write failure. Reload software from host.
Indicates SensorNet transmission errors.
No power.
Code converter in loopback test.
Addendums
Addendum A:
Performing a SensorNet Ping Test on a Dome Camera
To conduct a ping test from the controller to a dome, select the dome camera and run the test (described in the appropriate operator manual).
Note:
- Address selected at the controller determines the dome camera tested.
- Dome address switch settings must be correct.
- The code converter responds to pings if the dome is responding.
- If the code converter is selected, only the communication line from the controller to the converter is tested.
- For how to get dome information and to conduct the ping test from the controller, refer to ADTT16E (8200-0306-02) and VM16 (8000­2653-01) operation instructions. For just the ping test, refer to MegaPower LT operation instructions (MP-LTHB-1).
Note: If a controller requests device information from a camera having the same address as the converter, the controller receives configuration information from the converter instead of the dome.
Addendum B: Performing an RS-422 Line Test
For each RS-422 port: Press and hold the port’s line status test switch and view the adjacent LED. The LED lights as follows:
Constant green, Blinking red
Constant green, No red
Constant red, Blinking green
Blinking red, Green off
Both LEDs off "Data In" + and – wires shorted
RS-422 line correctly wired.
"Data In" – shorted to ground.
"Data In" + and – wires reversed.
"Data In" + shorted to ground.
or open.
Addendum C: Resetting the Code Converter
If communications cease, press the reset switch on the front panel using a paper clip. If that fails, try recycling power.
Addendum D: Performing an RS-422 Loopback Test
1. Disconnect data lines from all seven RS-422 connectors.
2. Wire each connector’s pins as follows:
Pin 1 white wire (RX+) loops to Pin 3 (TX+)
Pin 2 gray wire (RX–) loops to Pin 4 (TX–)
3. Set the code converter to address 00.
4. Press the RS-422 line test switch to the right of the port.
5. If the LED adjacent top the port lights, that port is working. If the LED remains off, the port is not working.
6. Repeat steps 4 and 5 for the next port.
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
4 of 7
Page 5
Addendum E: ADTT16E to RCSN422 Installation Wiring
Code Converter
RS-422
J1 J2 J3 J4 J5
J6 J7 J8 J9 J10
RJ860AP
J-BOX
2
2
g
4
4
n
v
d
v
a
a
c
c
t
t
e
e
N
N
r
r
o
o
s
s
c
RX–
TX+ TX–
12 11 10
9 8 7 6 5 4 3 2 1
RX+
0
3
0
E
D
B
1
J
c
n
n
.
a
a
e
e
d
V
V
S
n
S
4
4
2
2
G
3
J
0
-
1
0
0
0
-
1
0
M
I
5
J
R
4
9
J
2
6 0 0 3
-
0 0 4 7
­0
1
0
D
A
T
O
C
H
U
3
0
1
T
T
T
R
A
E
6
R
K
E
C
-
3
4
2
2
-
0
0
1
RL-860-AP J-Box
J1–10 J5 P3 P1 P7
Pin 1 (TX+) Pin 1 (RX+) Pin 7 (RX+) Pin 1 (RX+) Pin 1 (RX+) Pin 6 (RX+) Pin 1 (RX+)
Pin 2 (TX–) Pin 2 (RX–) Pin 6 (RX–) Pin 2 (RX–) Pin 2 (RX–) Pin 7 (RX–) Pin 2 (RX–)
Pin 3 (AC) Pin 3 (AC) Pin 3 (AC) (AC) (AC) Pin 3 (AC) Pin 3 (AC)
Pin 4 (GND) Pin 4 (GND) Pin 4 (GND) (GND) (GND) Pin 4 (GND) Pin 4 (GND)
Pin 5 (AC) Pin 5 (AC) Pin 5 (AC) (AC) (AC) Pin 5 (AC) Pin 5 (AC)
Pin 6 (N/A)
Pin 7 (RX–) Pin 7 (TX–) Pin 1 (TX–) Pin 4 (TX–) Pin 9 (TX–) Pin 4 (TX–)
Pin 8 (RX+) Pin 8 (TX+) Pin 2 (TX+) Pin 3 (TX+) Pin 8 (TX+) Pin 3 (TX+)
To MiniDome
To Unicard SpeedDome
To Optima
To Optima LT
To SpeedDome Ultra Pigtail
To SpeedDome Ultra I/O
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
5 of 7
Page 6
Addendum E: MegaPower LT to RCSN422 Installation Wiring
Code Converter
RS-422
J1 J2 J3 J4 J5
J6 J7 J8 J9 J10
RJ860AP
J-BOX
2
2
g
4
4
n
v
d
v
a
a
c
SensorNet from MegaPower LT
RX–
TX+ TX–
12 11 10
9 8 7 6 5 4 3 2 1
RX+
Matrix Switcher
c
RL-860-AP J-Box
J1–10 J5 P3 P1 P7
Pin 1 (TX+) Pin 1 (RX+) Pin 7 (RX+) Pin 1 (RX+) Pin 1 (RX+) Pin 6 (RX+) Pin 1 (RX+)
Pin 2 (TX–) Pin 2 (RX–) Pin 6 (RX–) Pin 2 (RX–) Pin 2 (RX–) Pin 7 (RX–) Pin 2 (RX–)
Pin 3 (AC) Pin 3 (AC) Pin 3 (AC) (AC) (AC) Pin 3 (AC) Pin 3 (AC)
Pin 4 (GND) Pin 4 (GND) Pin 4 (GND) (GND) (GND) Pin 4 (GND) Pin 4 (GND)
Pin 5 (AC) Pin 5 (AC) Pin 5 (AC) (AC) (AC) Pin 5 (AC) Pin 5 (AC)
Pin 6 (N/A)
Pin 7 (RX–) Pin 7 (TX–) Pin 1 (TX–) Pin 4 (TX–) Pin 9 (TX–) Pin 4 (TX–)
Pin 8 (RX+) Pin 8 (TX+) Pin 2 (TX+) Pin 3 (TX+) Pin 8 (TX+) Pin 3 (TX+)
To MiniDome
To Unicard SpeedDome
To Optima
To Optima LT
To SpeedDome Ultra Pigtail
To SpeedDome Ultra I/O
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
6 of 7
Page 7
Addendum F: Flashing Firmware on the RCSN422 Using an ADCASNET Module
Procedure
1. Download and install the ADCASNET utility from http://www.americandynamics.net. Click on Support/Software Downloads/USB Control Module/USB Control Module Utilities/ADUtils_1_00.zip.
2. Download RCSN422 hex file from the web site and copy it to c:\program files\AD_Utilities (Note: This file must be F2814-0102 or higher).
3. Set the code converter to address 32.
4. Launch the ADCASNET utility and click “Load Utility”.
5. Click the “Scan Network” icon; the load utility will look for the code converter on the right-hand screen.
6. Once it detects the code converter, the firmware version is displayed. For example: 2814-XXXX.
7. Click on the displayed version and then click “Load Snet Device”. A progress bar appears.
8. When complete, close the ADCASNET utility and reboot the code converter.
9. Rescan the code converter and verify firmware was updated.
SENSORNET TO RS-422 CODE CONVERTER 8000-2593-01, REV. C INSTALLATION GUIDE
7 of 7