American Dynamics RASELHC, RASELHS, RASELPC, RASELPS, RASONPC Installation

...
SpeedDome® Optima LT Indoor Camera Dome
Installation and Service Guide
Contents
Warnings................................................................2
Before You Begin................................................... 3
Installation..............................................................6
Troubleshooting .....................................................9
Parts List for Authorized Users ............................ 10
Specifications.......................................................12
Declarations ......................................................... 14
The SpeedDome Optima LT indoor camera dome mounts either to a hard ceiling or to a 2x2 tile ceiling using a mounting plate (instructions for the plate are supplied separately).
CAUTION: Save the box and packing materials. These materials are required should you need to ship the dome to a repair center.
Note: The dome accepts either cable or conduit. If running cable through a plenum ceiling, either plenum-rated cable or flexible conduit is required.
© 2006 Sensormatic Electronics Corp.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E INSTALLATION AND SERVICE GUIDE 1 of 14

Warnings

Please review the following warnings before you install or service the camera dome.
ALWAYS USE:
Proper safety equipment for the location and type of installation.
Proper lift equipment to reach the installation.
Safety features of the lift equipment.
BE SURE:
Electrical power is not connected to the dome when connecting wires. Camera will move when power is applied.
Electrical power is not connected to nearby fixtures that you might touch during installation.
DO NOT install this dome in hazardous areas where highly combustible or explosive products are stored or used.
This dome runs on 24Vac. DO NOT connect line voltage to this dome.
North America power requirements: In North America, this device is intended to be supplied from a Class 2 power supply.
This installation should be made by a qualified service person and should conform to all local codes.
EU power requirements: This product runs on 24Vac. In the EU, it is intended to be powered from a Limited Power Source. A limited power source is a certified source of SELV, and if inherently limited, with 8 amps maximum output current, and a maximum of 100VA available; or if not inherently limited, fused with a maximum value of 3.3 Amps, meeting section 2.11 of IEC950, and a maximum of 250VA available. The power supply can be obtained through Sensormatic or through another source where the provider can furnish the verification. This is required to assure electrical safety in the product.
Stromanforderungen in der EU: Dieses Produkt wird mit 24 V Wechselstrom betrieben. In der EU ist es für den Betrieb durch eine begrenzte Stromquelle vorgesehen. Eine begrenzte Stromquelle ist eine zertifizierte SELV-Quelle (Schutzkleinspannung), bei inhärenter Begrenzung mit einem maximalen Ausgangsstrom von 8 A und 100 VA maximaler Verfügbarkeit, bei nicht inhärenter Begrenzung mit einer maximalen Sicherung von 3,3 A gemäß Abschnitt 2.11 der IEC950 und 250 VA maximaler Verfügbarkeit. Das Netzteil kann über Sensormatic oder eine andere Quelle bezogen werden, wobei der Anbieter den Nachweis der Konformität bereitstellen sollte. Dies ist zur Gewährleistung der elektrischen Sicherheit des Produktes erforderlich.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E INSTALLATION AND SERVICE GUIDE 2 of 14

Before You Begin

To ensure a smooth and successful installation, observe the following requirements.
General Requirements
Have electrical work comply with latest national electrical code, national fire code, and all applicable local codes and ordinances.
Coordinate work with other trades to avoid interference.
Verify existing site conditions and coordinate with the owner’s representative and appropriate utilities as required.
Obtain copies of all related plans, specifications, shop drawings and addenda to schedule and coordinate related work.
Thoroughly review the project to ensure that all work meets or exceeds the above requirements. Bring alleged discrepancies to the attention of the CCTV Project Coordinator.
Mounting Requirements
Mounting space: Ensure there is the following space above the ceiling to accommodate the dome.
Height above ceiling:
Diameter: 192mm (7.5in)
Structural members: Verify that ceiling members can support the camera dome and mounting structure, if used.
170mm (6.7in)
Data cable requirements
SensorNet
Cable type 1 unshielded,
twisted pair*
Wire gauge 22 AWG 22AWG 18 AWG
Connection Non-
polarized
Max. devices per cable run
* Power, data, and video cables can be ordered separately or
within a composite cable that can be ordered in various lengths. Plenum-rated cables must be used in indoor ceilings used for environmental air return (called "other air space" in the National Electrical Code). Order parts through your distribution network.
Note: If you order cable from an outside source, wire colors may be different.
** The RS-422 Simplex connection only uses a single twisted
pair allowing the dome to receive only. RS-422 transmit from the dome is not supported.
*** Belden 88760 (plenum), or Belden 8760 cable (non-plenum)
cable is recommended. Plenum-rated cables must be used in indoor ceilings used for environmental air return (called "other air space" in the National Electrical Code). Order cable directly from Belden by calling 1-800-235-3361.
32 10 3
RS-422 Simplex Manchester
1 shielded, twisted pair* **
Polarized Polarized
1 shielded twisted pair***
Plenum ceilings: Cable must be rated for plenum or routed through flexible conduit. A cover plate for the dome accepts ½" conduit.
WARNING! Do not run cables adjacent
to or in the same conduit as line voltage mains power.
Weight: 2.5kg (5.5 lbs)
Power cables. Make power cable lengths as short as possible to minimize the affects of low line
Cable Requirements
Data cables: The following table shows cable
requirements for SensorNet, RS-422 and Manchester networks. For more information about communication protocols and cable networks, see Communication Protocols and Cable Networks, 8000-2573-19.
voltages and outdoor cold temperature performance. Maximum cable length between a Class 2 LPS (low voltage) ac source, such as a J­box, and the dome depends on the ac line voltage. See the tables below for maximum cable lengths based on the worst-case low line voltages.
The line voltage must not go below the voltage shown for the dome to be able to power up and operate at the corresponding distances shown. Typically cable distances are used that provide a 15% margin between nominal and low line conditions. For example, if the nominal voltage measures 120Vac, restrict the cable length to the distance for .85 x 120 or approximately 100Vac.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E INSTALLATION AND SERVICE GUIDE 3 of 14
r
Power cable requirements—Indoor Dome
Table 1 shows the maximum cable distance for several worst-case low line voltages between various indoor power sources and the indoor SpeedDome Optima. These distances are for Sensormatic composite cables, which use 18 ac power wires.
This table applies to domes produced after October of 2001; distances are much less for earlier domes.
Twisted Pair Adapter
The ADACTP01BNC Twisted Pair Adapter (supplied) can be used to transmit video or video with up-the-coax (UTC) dome control signals over unshielded twisted pair (UTP) cables, point-to­point, up to 300m (1000ft).
The adapter mounts directly to the video source or receiver without additional cabling and uses Category 2-6 twisted pair wires to transmit the video and dome control signals. The adapter does not require power.
One adapter is supplied. If used, another adapter must be ordered to for the connection at the other end of the cable. The figure below shows twisted pair cable connections. See installation guide 8200-0298-01 for details.
Twisted Pair Adapter (Dome End)
American Dynamics
Dome O
Fixed Camera
Twisted Pair Adapter (Fixed Camera End)
Cat 2-6 UTP Cable
AWG
Table 1. Maximum cable length and worst-case low line voltages
Indoor Dome
AC Power Source
28 VA
Transformer
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
or RS-422 J-Box
RJ1SNUD, RS856UD
1-position SensorNet
or RS-422 J-Box
RJ1SNUD-1, RS856UD-1
6-position SensorNet
Indoor J-Box
RJ6SN
10-position RS-422
Indoor 120V/60Hz J-Box
RJ860AP
10-position RS-422
Indoor 240V/50Hz J-Box
RJ860AP1
Universal Transformer
0300-0914-01
Universal Transformer
0300-0914-03
Worst-Case Meters
Low Line V (Feet)
117 130 (425)
100 80 (250)
90 60 (200)
117 160 (525)
100 100 (325)
90 60 (200)
117 160 (525)
100 100 (325)
90 80 (250)
240 160 (525)
200 100 (325)
180 80 (250)
117 210 (675)
100 130 (425)
90 80 (250)
240 210 (675)
200 130 (425)
180 80 (250)
117 200 (625)
100 130 (425)
90 100 (325)
240 225 (750)
200 160 (525)
180 125 (375)
117 130 (425)
100 100 (325)
90 60 (200)
240 160 (525)
200 100 (325)
180 80 (250)
Twisted Pair Adapter (Switcher/Controller End)
Video Switcher/
Controller
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E INSTALLATION AND SERVICE GUIDE 4 of 14
SensorNet Line Termination
SensorNet communication protocols require line termination. Accessing slide switch S1 through the hole in the top of the dome, terminate the dome furthest from the video controller or junction box by moving the switch to the “terminated” position. All other domes along the line must be unterminated.
Manchester and RS-422 protocols do not require line termination.
Setting the Camera Address
Accessed through the hole in the top of the dome are rotary switches SW1, SW2, and SW3 are used to set the dome address.
Protocol address ranges are as follows:
SensorNet 1-255
Manchester 1-64
RS-422 1-99
For example, for address 107, set SW3 to 1, SW2 to 0 (black dot), and SW1 to 7.
Power-Up Routine
After power is connected to the dome, the dome performs a homing routine. During the homing process, the camera will pan and then either:
Go to the start point of the “apple peel” pattern, or
If powered up once before, to the last position in memory.
Once the camera stops, the camera is online and is ready to be controlled.
Synchronizing Domes
To prevent picture rolling when switching from camera to camera, all domes can be synchronized to the ac source. A V-phase adjustment at the control console enables the dome to sync to any line phase.
Save Packaging Material
Should the camera dome need to be sent to a repair center, use the packaging that the dome was shipped in.
Compatibility with the VM96 Controller
If using a VM96 controller, the controller must be Version 5.2 or higher.
Box for Bubble
Plastic Bag
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E INSTALLATION AND SERVICE GUIDE 5 of 14