The SpeedDome Optima LT indoor camera dome
mounts either to a hard ceiling or to a 2x2 tile
ceiling using a mounting plate (instructions for the
plate are supplied separately).
CAUTION: Save the box and packing
materials. These materials are required
should you need to ship the dome to a
repair center.
Note: The dome accepts either cable or conduit. If
running cable through a plenum ceiling, either
plenum-rated cable or flexible conduit is required.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E
INSTALLATION AND SERVICE GUIDE 1 of 14
Warnings
Please review the following warnings before you
install or service the camera dome.
ALWAYS USE:
• Proper safety equipment for the location and
type of installation.
• Proper lift equipment to reach the installation.
• Safety features of the lift equipment.
BE SURE:
• Electrical power is not connected to the dome
when connecting wires. Camera will move when
power is applied.
• Electrical power is not connected to nearby
fixtures that you might touch during installation.
DO NOT install this dome in hazardous areas
where highly combustible or explosive products are
stored or used.
This dome runs on 24Vac. DO NOT connect line
voltage to this dome.
North America power requirements: In North
America, this device is intended to be supplied
from a Class 2 power supply.
This installation should be made by a qualified
service person and should conform to all local
codes.
EU power requirements: This product runs on
24Vac. In the EU, it is intended to be powered from
a Limited Power Source. A limited power source is
a certified source of SELV, and if inherently limited,
with 8 amps maximum output current, and a
maximum of 100VA available; or if not inherently
limited, fused with a maximum value of 3.3 Amps,
meeting section 2.11 of IEC950, and a maximum of
250VA available. The power supply can be
obtained through Sensormatic or through another
source where the provider can furnish the
verification. This is required to assure electrical
safety in the product.
Stromanforderungen in der EU: Dieses Produkt
wird mit 24 V Wechselstrom betrieben. In der EU
ist es für den Betrieb durch eine begrenzte
Stromquelle vorgesehen. Eine begrenzte
Stromquelle ist eine zertifizierte SELV-Quelle
(Schutzkleinspannung), bei inhärenter Begrenzung
mit einem maximalen Ausgangsstrom von 8 A und
100 VA maximaler Verfügbarkeit, bei nicht
inhärenter Begrenzung mit einer maximalen
Sicherung von 3,3 A gemäß Abschnitt 2.11 der
IEC950 und 250 VA maximaler Verfügbarkeit. Das
Netzteil kann über Sensormatic oder eine andere
Quelle bezogen werden, wobei der Anbieter den
Nachweis der Konformität bereitstellen sollte. Dies
ist zur Gewährleistung der elektrischen Sicherheit
des Produktes erforderlich.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E
INSTALLATION AND SERVICE GUIDE 2 of 14
Before You Begin
To ensure a smooth and successful installation,
observe the following requirements.
General Requirements
• Have electrical work comply with latest national
electrical code, national fire code, and all
applicable local codes and ordinances.
• Coordinate work with other trades to avoid
interference.
• Verify existing site conditions and coordinate
with the owner’s representative and appropriate
utilities as required.
• Obtain copies of all related plans, specifications,
shop drawings and addenda to schedule and
coordinate related work.
• Thoroughly review the project to ensure that all
work meets or exceeds the above requirements.
Bring alleged discrepancies to the attention of
the CCTV Project Coordinator.
Mounting Requirements
Mounting space: Ensure there is the following
space above the ceiling to accommodate the
dome.
Height above ceiling:
Diameter: 192mm (7.5in)
Structural members: Verify that ceiling members
can support the camera dome and mounting
structure, if used.
170mm (6.7in)
Data cable requirements
SensorNet
Cable type 1 unshielded,
twisted pair*
Wire gauge 22 AWG 22AWG 18 AWG
Connection Non-
polarized
Max. devices
per cable run
* Power, data, and video cables can be ordered separately or
within a composite cable that can be ordered in various
lengths. Plenum-rated cables must be used in indoor
ceilings used for environmental air return (called "other air
space" in the National Electrical Code). Order parts through
your distribution network.
Note: If you order cable from an outside source, wire colors
may be different.
** The RS-422 Simplex connection only uses a single twisted
pair allowing the dome to receive only. RS-422 transmit
from the dome is not supported.
*** Belden 88760 (plenum), or Belden 8760 cable (non-plenum)
cable is recommended. Plenum-rated cables must be used
in indoor ceilings used for environmental air return (called
"other air space" in the National Electrical Code). Order
cable directly from Belden by calling 1-800-235-3361.
32 10 3
RS-422
Simplex Manchester
1 shielded,
twisted
pair* **
Polarized Polarized
1
shielded
twisted
pair***
Plenum ceilings: Cable must be rated for plenum
or routed through flexible conduit. A cover plate for
the dome accepts ½" conduit.
WARNING! Do not run cables adjacent
to or in the same conduit as line voltage
mains power.
Weight: 2.5kg (5.5 lbs)
Power cables. Make power cable lengths as short
as possible to minimize the affects of low line
Cable Requirements
Data cables: The following table shows cable
requirements for SensorNet, RS-422 and
Manchester networks. For more information about
communication protocols and cable networks, see
Communication Protocols and Cable Networks,
8000-2573-19.
voltages and outdoor cold temperature
performance. Maximum cable length between a
Class 2 LPS (low voltage) ac source, such as a Jbox, and the dome depends on the ac line voltage.
See the tables below for maximum cable lengths
based on the worst-case low line voltages.
The line voltage must not go below the voltage
shown for the dome to be able to power up and
operate at the corresponding distances shown.
Typically cable distances are used that provide a
15% margin between nominal and low line
conditions. For example, if the nominal voltage
measures 120Vac, restrict the cable length to the
distance for .85 x 120 or approximately 100Vac.
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E
INSTALLATION AND SERVICE GUIDE 3 of 14
r
Power cable requirements—Indoor Dome
Table 1 shows the maximum cable distance for
several worst-case low line voltages between
various indoor power sources and the indoor
SpeedDome Optima. These distances are for
Sensormatic composite cables, which use 18
ac power wires.
This table applies to domes produced after October
of 2001; distances are much less for earlier domes.
Twisted Pair Adapter
The ADACTP01BNC Twisted Pair Adapter
(supplied) can be used to transmit video or video
with up-the-coax (UTC) dome control signals over
unshielded twisted pair (UTP) cables, point-topoint, up to 300m (1000ft).
The adapter mounts directly to the video source or
receiver without additional cabling and uses
Category 2-6 twisted pair wires to transmit the
video and dome control signals. The adapter does
not require power.
One adapter is supplied. If used, another adapter
must be ordered to for the connection at the other
end of the cable. The figure below shows twisted
pair cable connections. See installation guide
8200-0298-01 for details.
Twisted Pair Adapter
(Dome End)
American Dynamics
Dome O
Fixed Camera
Twisted Pair Adapter
(Fixed Camera End)
Cat 2-6 UTP Cable
AWG
Table 1. Maximum cable length and worst-case
low line voltages
Indoor Dome
AC Power Source
28 VA
Transformer
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
or RS-422 J-Box
RJ1SNUD, RS856UD
1-position SensorNet
or RS-422 J-Box
RJ1SNUD-1, RS856UD-1
6-position SensorNet
Indoor J-Box
RJ6SN
10-position RS-422
Indoor 120V/60Hz J-Box
RJ860AP
10-position RS-422
Indoor 240V/50Hz J-Box
RJ860AP1
Universal Transformer
0300-0914-01
Universal Transformer
0300-0914-03
Worst-Case Meters
Low Line V (Feet)
117 130 (425)
100 80 (250)
90 60 (200)
117 160 (525)
100 100 (325)
90 60 (200)
117 160 (525)
100 100 (325)
90 80 (250)
240 160 (525)
200 100 (325)
180 80 (250)
117 210 (675)
100 130 (425)
90 80 (250)
240 210 (675)
200 130 (425)
180 80 (250)
117 200 (625)
100 130 (425)
90 100 (325)
240 225 (750)
200 160 (525)
180 125 (375)
117 130 (425)
100 100 (325)
90 60 (200)
240 160 (525)
200 100 (325)
180 80 (250)
Twisted Pair Adapter
(Switcher/Controller End)
Video Switcher/
Controller
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E
INSTALLATION AND SERVICE GUIDE 4 of 14
SensorNet Line Termination
SensorNet communication protocols require line
termination. Accessing slide switch S1 through the
hole in the top of the dome, terminate the dome
furthest from the video controller or junction box by
moving the switch to the “terminated” position. All
other domes along the line must be unterminated.
Manchester and RS-422 protocols do not require
line termination.
Setting the Camera Address
Accessed through the hole in the top of the dome
are rotary switches SW1, SW2, and SW3 are used
to set the dome address.
Protocol address ranges are as follows:
SensorNet 1-255
Manchester 1-64
RS-422 1-99
For example, for address 107, set SW3 to 1, SW2
to 0 (black dot), and SW1 to 7.
Power-Up Routine
After power is connected to the dome, the dome
performs a homing routine. During the homing
process, the camera will pan and then either:
• Go to the start point of the “apple peel” pattern,
or
• If powered up once before, to the last position in
memory.
Once the camera stops, the camera is online and
is ready to be controlled.
Synchronizing Domes
To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to the ac source. A V-phase adjustment at the
control console enables the dome to sync to any
line phase.
Save Packaging Material
Should the camera dome need to be sent to a
repair center, use the packaging that the dome was
shipped in.
Compatibility with the VM96 Controller
If using a VM96 controller, the controller must be
Version 5.2 or higher.
Box for
Bubble
Plastic Bag
SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200-0181-01, REV. E
INSTALLATION AND SERVICE GUIDE 5 of 14