W ARNING: For your safety the information in
this manual must be followed to minimize the
risk of fire or explosion or to prevent property
damage, personal injury or death.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHA T TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electrical switch; do not
use any phone in your building.
•Clear the room, building or area of all
occupants.
•Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
— QUE F AIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
•Ne pas tenter d’allumer d’appareils.
•Ne touchez à aucun interrupteur . Ne pas
vous servir des téléphones se trouvant dans
le bâtiment.
•Évacuez la pièce, le bâtiment ou la zone.
•Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.
•Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
— L ’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
RET AIN THESE INSTRUCTIONS IN A SAFE
PLACE FOR FUTURE REFERENCE
020502JEV/mcronanPart No. 113364
Retain This Manual In A Safe Place For Future Reference
This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will
provide many years of safe, efficient, and trouble-free operation.
ONLY qualified technicians should service this equipment.
OBSERVEALLSAFETYPRECAUTIONS displayed on the equipment or specified in the installation manual included with
the dryer.
The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
W e have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer reserves the
right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to
change or discontinue models. The illustrations included in this manual may not depict your particular dryer exactly.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
Important
For your convenience, log the following information:
DA TE OF PURCHASE________________________________ MODEL NO. __________________________________________
DISTRIBUTOR’S NAME ____________________________________________________________________________________
Serial Number(s)________________________________________________________________________________________
For replacement parts, contact the distributor from which the dryer was purchased or contact:
Maytag Co.
403 W est Fourth Street North
Newton, Iowa 50208
(641) 787-7000
“IMPORT ANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the instructions
to be followed if the user smells gas. These instructions must be posted in a
prominent location near the dryer.
IMPORTANT
YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPL Y and THE GAS
SUPPL Y BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE
TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, or TESTING
OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration)
ST ANDARDS.
«Attention: Lor des opérations d’entretien
“Caution: Label all wires prior to
disconnection when servicing controls. W iring
errors can cause improper operation.”
des commandes étiqueter tous fils avant
de les déconnecter. Toute erreur de
câblage peut étre une source de danger et
de panne.»
CAUTION
DR YERS SHOULD NEVER BE LEFT UNA TTENDED WHILE IN OPERA TION.
WARNING
CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR THE DRYERS.
CHILDREN SHOULD BE SUPERVISED IF NEAR DR YERS IN OPERATION.
FOR YOUR SAFETY
DO NOT DR Y MOP HEADS IN THE DRYER.
DO NOT USE DR YER IN THE PRESENCE OF DR Y CLEANING FUMES.
WARNING
UNDER NO CIRCUMSTANCES should the dryer door switch, lint drawer switch, or
heat safety circuit ever be disabled.
WARNING
The dryer must never be operated with any of the back guards, outer tops, or service
panels removed. PERSONAL INJURY or FIRE COULD RESUL T .
WARNING
DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FIL TER (SCREEN) IN
PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.
IMPORTANT
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or
specified in the installation manual included with the dryer.
Dryers must not be installed or stored in an area where it will be exposed to water or weather .
The wiring diagram for the dryer is located in the front electrical control box area.
Table of Contents
SECTION I
IMPORTANT INFORMATION ............................................................................... 3
A. Receiving and Handling ............................................................................................................... 3
B. Safety Precautions ...................................................................................................................... 4
Optional Gas Piping Kit .................................................................................................................. 46
SECTION I
IMPORTANT INFORMA TION
A. RECEIVING AND HANDLING
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or
optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and
wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect
further before delivering carrier leaves.
Dryers Damaged in Shipment:
1. ALL dryers should be inspected upon receipt and before they are signed for.
2. If there is suspected damage or actual damage, the trucker ’s receipt should be so noted.
3. If the dryer is damaged beyond repair, it should be refused. Those dryers which were not damaged in a
damaged shipment should be accepted, but the number received and the number refused must be noted
on the receipt.
4. If you determine that the dryer was damaged after the trucker has left your location, you should call the
delivering carrier’s freight terminal immediately and file a claim. The freight company considers this
concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult
when more than a day or two passes after the freight was delivered. It is your responsibility to file freight
claims. Dryer/parts damaged in transit cannot be claimed under warranty.
5. Freight claims are the responsibility of the consignee, and ALL claims must be filed at the receiving end.
Manufacturer assumes no responsibility for freight claims or damages.
IMPORTANT: The dryer must be transported and handled in an upright position at ALL times.
3
B. SAFETY PRECAUTIONS
WARNING: For your safety , the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury , or loss of life.
WARNING: The dryer must never be operated with any of the back guards, outer tops, or
service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T .
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the
user smells gas. The instructions should be posted in a prominent location.
3. WHAT TO DO IF YOU SMELL GAS...
a. DO NOT try to light any appliance.
b. DO NOT touch any electrical switch.
c. DO NOT use any phone in your building.
d. Clear the room, building, or area of
e. Immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions.
f. If you cannot reach your gas supplier, call the fire department.
4. Installation and service must be performed by a qualified installer, service agency , or gas supplier.
5. Dryer(s) must be exhausted to the outdoors.
6. Although Maytag produces a very versatile dryer, there are some articles that, due to fabric composition or
cleaning method, should not be dried in it.
ALL occupants.
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry
cleaning solvents, a combustible detergent, or “all purpose” cleaner .
EXPLOSION COULD RESUL T .
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint,
or wax.
EXPLOSION COULD RESUL T .
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a
fire hazard.
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or
similarly textured rubber materials. Drying in a heated basket (tumbler) may damage
plastics or rubber and may be a fire hazard.
4
7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust
ductwork, and inside the dryer. The frequency of inspection and cleaning can best be determined from
experience at each location.
WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to do so will VOID THE WARRANTY.
9. UNDERNOCIRCUMSTANCES should the dryer door switch, lint drawer switch, or heat safety
circuit ever be disabled.
W ARNING: PERSONAL INJURY OR FIRE COULD RESUL T.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
13. For safety, proper operation, and optimum performance, the dryer must not be operated with a load less
than sixty-six percent (66%), 20 pounds (9.1 kg) of its rated capacity.
W ARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED
FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING ,
ADJUSTING , INSTALLA TION, OR TESTING OF ANY EQUIPMENT PER
OSHA (Occupational Safety and Health Administration) STANDARD.
5
SECTION II
SPECIFICATIONS
A44”111.76 cm
B42-3/4”
C5-5/8”
D16-11/16”
E1-3/16”
F71-1/2”
Shaded areas are in metric equivalents
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice
or obligation.
6
108.58 cm
14.29 cm
42.38 cm
3.02 cm
181.61 cm
MAXIMUM C APACI TY (TO TAL DRY WEIGHT)60 lbs27.2 kg
BAS K ET ( TUMBLER) DIA METER27 -1 /4 ”
BAS K ET ( TUMBLER) DEP TH30 ”
BAS K ET ( TUMBLER) VOLUME ( P ER BAS KET)10 . 1 c u. ft.
BAS K ET ( TUMBLER) M O TO R ( 2 P LACES )1/ 3 HP
DO O R OP ENIN G - DIAM ETER ( 2 P LAC ES )21 -1 /2 ”
VOLTAGE
AVAILABLE120-240v 1Ø 50/60 Hz
APP RO X. WEIGHT (UN C RATED)79 3 lbs
APPROX.
HEAT
W EIGHT ( C RATED)86 0 lbs390.1 kg
INPUT (TOTAL F OR BO TH BAS K ETS )13 6 , 00 0 b tu/hr34,272 kcal/hr
69.22 cm
76.2 cm
0.286 cu.m.
0.279 kw
54.61 cm
359.7 kg
Gas
AIRFLOW
GAS
Shaded areas are stated in met ric equi val ent s
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice
or obligation.
(P ER BAS KET/TUMBLER)40 0 c fm11.3 cmm
INL ETSIZE (2 PLACES)1/2” F.P.T.
7
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the
absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical
Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91
(Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General
Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION
(for Electrical Connections).
A. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap and/or optional shipping box) from dryer.
NOTE: The access keys for the service doors are included in the information packet shipped in the
basket (tumbler). These keys should be removed and put in a safe place yet made accessible
because some will be needed throughout various phases in the installation of the dryer .
Dryers are shipped with a coin box and coin box faceplate ONLY. The coin box lock is not included and
must be purchased elsewhere or the lock can be ordered as a parts order from the manufacturer.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. T o unskid
the dryer, locate and remove the four (4) bolts securing the base of the dryer to the wooden skid. Two (2) are
at the rear of the base, and two (2) are located in the front. Once the bolts are removed, slide the dryer off the
skid.
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4)
leveling legs, so that the dryer will slide on the legs instead of the base frame. The dryer is equipped with four
(4) leveling legs, one (1) at each corner of the dryer base. The hex head adjustment bolts for the two (2) front
leveling legs are located directly behind the lower access door, and the rear two (2) adjustments are directly
behind the lower rear back (guard) panel.
For more effective automatic door closure and better tumbling action (and improved efficiency), the dryer
should be tilted slightly to the rear.
B. LOCATION OF THE DRYER
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such
codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1-LATEST
EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.
8
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be
removed from the floor area that the dryer is to rest on.
IMPORTANT: “The dryer must be installed on noncombustible floors only .”
2. The dryer must not be installed or stored in an area where it will be exposed to water or weather.
3. The dryer is for use in noncombustible locations.
4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply
Requirements in Section D).
5. Clearance provisions must be made from noncombustible construction as noted in this manual (refer to
Dryer Enclosure Requirements in
Section C).
Even though a 12-inch (30.48 cm) clearance is acceptable,
positioned approximately 2 feet (0.61 meters) away from the nearest obstruction, i.e., wall, for ease of
installation, maintenance, and service. (Refer to the illustration below.)
6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual
(refer to Dryer Enclosure Requirements in Section C).
7. Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as
noted in this manual (refer to Exhaust Requirements in Section E).
8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual
(refer to Exhaust Requirements in Section E).
it is recommended that the rear of the dryer be
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct willbe necessary.
9
Even though a 12-inch (30.48 cm) clearance is acceptable,
positioned approximately 2 feet (0.61 meters) away from the nearest obstruction, i.e., wall, for ease of
installation, maintenance, and service.
9. The dryer must be installed with a proper exhaust duct connection to the outside.
10. The dryer must be installed with provisions for adequate combustion and make-up air supply.
it is recommended that the rear of the dryer be
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of
12-inches (30.48 cm) - (18-inches [45.72 cm] or more is recommended for ease of installation, maintenance, and
service) - above the dryer’s outer top, except along the front of the dryer which may be closed in if desired.
NOTE: Even though a minimum of 12-inches (30.48 cm) above the dryer’s outer top is acceptable, a
clearance of 18-inches (45.72 cm) or more is suggested for ease of installation and service
(electrical power connections).
NOTE: When fire sprinkler systems are located above the dryers, a minimum of 12-inches (30.48 cm)
above the dryer’s outer top is required.
NOTE: Allowances must be made for opening the control door .
Dryers may be positioned sidewall to sidewall. However, allowances must be made for opening and closing of
the control door and the lint door. It is suggested that the dryer be positioned about 2 feet (0.61 meters) away
from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back
guard). Refer to the illustration on the previous page for details.
NOTE: Air considerations are important for proper and efficient operation.
10
D. FRESH AIR SUPPLY REQUIREMENTS
Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An
unrestricted source of 800 cfm (22.65 cmm) is necessary for each dryer. An unrestricted air entrance from the
outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is required for each dryer. This
area must be enlarged if louvers or registers cover the opening. It is not necessary to have a separate
make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be
set up in such a manner that the make-up air is distributed equally to the dryers. For example, for a bank of eight
(8) dryers, a total make-up air opening of 12 square feet (1.15 square meters) is required. Two (2) openings
measuring 2 feet by 3 feet (6 square feet) - 0.61 meters by 0.91 meters (0.56 square meters) are acceptable.
The dryer must be installed with provisions for adequate combustion and make-up air supply .
Allowances must be made for remote or constricting passageways or where dryers are located at excessive
altitudes or predominantly low-pressure areas.
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.
IMPORTANT: Make-up air openings should not be located near ductwork exhaust outlets. If
make-up air openings are too close to the exhaust outlet, lint and fumes may be drawn
back into the dryer area through these openings.
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.
11
E. EXHAUST REQUIREMENTS
Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will
create excessive back pressure, which results in slow drying, increased use of energy, overheating of the dryer,
and shut down of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats.
The dryer must be installed with a proper exhaust duct connection to the outside.
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors.
CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCTWORK CAN
CREA TE A POTENTIAL FIRE HAZARD.
The exhaust ductwork should be laid out in such a way that the ductwork travels as directly as possible to the
outdoors with as few turns as possible. When single dryer 10-inches (25.4 cm) vertical venting is used, the
ductwork from the dryer to the outside exhaust outlet must not exceed 35 feet (10.67 meters) or for 10-inches
(25.4 cm) horizontal 10 feet (3.05 meters). In the case of multiple (common) dryer venting, the distance from
the last dryer to the outside exhaust outlet must not exceed 15 feet (4.57 meters). The shape of the exhaust
ductwork is not critical so long as the minimum cross-sectional area is provided.
It is suggested that the use of 90º turns in ducting be avoided; use 30º or 45º angles instead. Excluding basket
(tumbler)/dryer elbow connections or elbows used for outside protection from the weather, no more than two (2)
elbows should be used in the exhaust duct run. If more than two (2) elbows are used the cross section area of
the ductwork must be increased in proportion to the number of elbows added.
1. Exhaust Connections of Top and Bottom Baskets (Tumblers)
There is no common venting connection provided with the dryer. Each basket (tumbler) exhaust duct is
provided with its own back draft damper. Each basket (tumbler) can be exhausted directly outdoors
independently or connected to a common duct. Both single or common ductwork can be rigid ducting or
flexible ducting. For common connections, a kit (ADC Part No. 882035) is available from the factory and
includes the necessary flex ducting, elbows, and “Y” assembly, etc., to join the top and bottom exhausts
together.
ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building.
IMPORTANT: Exhaust back pressure measured by a manometer at each basket (tumbler) exhaust
duct area must be no less than 0 and must not exceed 0.3 inches (0.74 mb) water
column (W .C.) when both baskets (tumblers) are operating.
NOTE: Common exhaust connections of top and bottom baskets (tumblers) should be installed in
such a manner that the back guards can be removed easily for servicing.
2. Single Dryer Venting
Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust ductwork
should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as
few turns as possible. It is suggested that the use of 90º turns in ducting be avoided; use 30º or 45º angles
instead. The shape of the exhaust ductwork is not critical so long as the minimum cross-sectional area is
provided.
12