American Dryer Corp D20 User Manual

Page 1
D20
Installation Manual
WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
— L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
JLA Limited
Meadowcroft Lane, Halifax Road
Ripponden
West Yorkshire, England
HX6 4AJ
Telephone: 01422 822282 / Fax: 01422 824390
100502GS/wmarelli ADC Part No. 113396
Page 2
Retain This Manual In A Safe Place For Future Reference
This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation.
ONLY qualified technicians should service this equipment.
OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.
The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
We have tried to make this manual as complete as possible and hope you will find it useful. Manufacturer reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models. The illustrations included in this manual may not depict your particular dryer exactly.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.
Important
For your convenience, log the following information:
DATE OF PURCHASE ________________________________ MODEL NO. __________________________________________
DISTRIBUTOR’S NAME ____________________________________________________________________________________
Serial Number(s) ________________________________________________________________________________________
D20
________________________________________________________________________________________
________________________________________________________________________________________
Replacement parts can be obtained from your distributor or J.L.A. When ordering replacement parts, you can FAX your order to J.L.A. at 01422 824390 or telephone your order directly to the J.L.A. Parts Department at 01422 822282. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
“IMPORTANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer.
Page 3
IMPORTANT
YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA
(Occupational Safety and Health Administration) STANDARDS.
«Attention: Au moment de l’entretien des “Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation.”
commandes, étiquetez tous les fils avant de
les débrancher. Des erreurs de câblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.»
CAUTION
DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.
WARNING
CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).
CHILDREN
SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.
FOR YOUR SAFETY
DO NOT DRY MOP HEADS IN THE DRYER. DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.
WARNING
UNDER NO CIRCUMSTANCES should the dryer main door switch, lint drawer switch, or the heat circuit devices ever be disabled.
Page 4
WARNING
The dryer must never be operated with the back guard removed. PERSONAL INJURY OR FIRE COULD RESULT.
WARNING
DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE.
IMPORTANT
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
Dryers must not be installed or stored in an area where it
will be exposed to water or weather.
Page 5
Table of Contents
SECTION I
IMPORTANT INFORMATION............................................................................... 2
A. Receiving and Handling ............................................................................................................... 2
B. Safety Precautions ...................................................................................................................... 3
SECTION II
SPECIFICATIONS .................................................................................................... 5
A. Specifications ............................................................................................................................. 5
SECTION III
INSTALLATION PROCEDURES ........................................................................... 7
A. Unpacking/Setting Up ................................................................................................................. 7
B. Location Requirements ............................................................................................................... 8
C. Dryer Enclosure Requirements .................................................................................................... 9
D. Fresh Air Supply Requirements ................................................................................................. 10
E. Exhaust Requirements ............................................................................................................... 11
F. Electrical Information ................................................................................................................ 14
G. Gas Information ........................................................................................................................ 20
H. Preparation For Operation/Start-Up ......................................................................................... 24
I. Preoperational Tests ................................................................................................................. 25
J. Shut Down Instructions ............................................................................................................. 26
SECTION IV
SERVICE/PARTS INFORMATION ...................................................................... 27
A. Service ..................................................................................................................................... 27
B. Parts ........................................................................................................................................ 27
SECTION V
WARRANTY INFORMATION .............................................................................. 28
A. Returning Warranty Cards ......................................................................................................... 28
B. Warranty .................................................................................................................................. 28
SECTION VI
ROUTINE MAINTENANCE .................................................................................. 29
A. Cleaning ................................................................................................................................... 29
SECTION VII
DATA LABEL INFORMATION ............................................................................. 31
A. Data Label ............................................................................................................................... 31
Page 6
SECTION I
IMPORTANT INFORMATION
A. RECEIVING AND HANDLING
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves.
Dryers damaged in shipment:
1.
ALL dryers should be inspected upon receipt and before they are signed for.
2. If there is suspected damage or actual damage, the trucker’s receipt should be so noted.
3. If the dryer is damaged beyond repair, it should be refused. Those dryers, which were not damaged in a damaged shipment, should be accepted, but the number received and the number refused must be noted on the receipt.
4. If you determine that the dryer was damaged after the trucker has left your location, you should call the delivering carrier’s freight terminal immediately and file a claim. The freight company considers this concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult when more than a day or two passes after the freight was delivered. It is your responsibility to file freight claims. Dryer/parts damaged in transit cannot be claimed under warranty.
5. Freight claims are the responsibility of the consignee, and ALL claims must be filed at the receiving end. Manufacturer assumes no responsibility for freight claims or damages.
IMPORTANT: The dryer must be transported and handled in an upright position at ALL times.
2
Page 7
B. SAFETY PRECAUTIONS
WARNING: For your safety, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury, or loss of life.
WARNING: The dryer must never be operated with the back guard removed. PERSONAL
INJURY OR FIRE COULD RESULT.
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.
3. WHAT TO DO IF YOU SMELL GAS...
a. DO NOT try to light any appliance.
b. DO NOT touch any electrical switch.
c. DO NOT use any phone in your building.
d. Clear the room, building, or area of ALL occupants.
e. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
f. If you cannot reach your gas supplier, call the fire department.
4. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
5. Dryer(s) must be exhausted to the outdoors.
6. Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry
cleaning solvents, a combustible detergent, or “all purpose” cleaner.
EXPLOSION COULD RESULT.
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint,
or wax. EXPLOSION COULD RESULT.
3
Page 8
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a
fire hazard.
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or
similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
7. A program should be established for the inspection and cleaning of lint in the exhaust ductwork and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
WARNING: The collection of lint in the exhaust ductwork can create a potential fire hazard.
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to do so will VOID THE WARRANTY.
9. UNDER NO CIRCUMSTANCES should the dryer main door switch, lint drawer switch, or the heat circuit devices ever be disabled.
WARNING: PERSONAL INJURY OR FIRE COULD RESULT.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
WARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPLY BEFORE ANY COVERS OR PANELS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.
4
Page 9
A. SPECIFICATIONS
SECTION II
SPECIFICATIONS
)THGIEWYRD(YTICAPACMUMIXAMsbl02 gk9
GasElectric
RETEMAID)RELBMUT(TEKSAB”57.52
HTPED)RELBMUT(TEKSAB”42
ROTOM)RELBMUT(TEKSABPH4/1
ROTOMREWOLBPH8/1
EMULOV)RELBMUT(TEKSAB.tf.uc5.7
NOITCENNOCTNEV”4
HTDIWTENIBAC”72
HTPEDTENIBAC”03
THGIEHTENIBAC”14
THGIEWTENTENIBACsbl732
WOLFRIA05H
WOLFRIA06H
Z
Z
ELBALIAVAEGATLOV
mc4.56
mc59.06
wk91.0
wk1.0
.m.uc12.0 mc2.01 mc6.86 mc2.67
mc401
gk7.701
mfc002 mmc66.5 mfc042 mmc97.6
,ø1/zH06/v8021/zH06/v021
ø1/zH05/v042,ø1/zH06/v042
TUPNITAEHrh/utb000,04
NOITCENNOCEPIPTELNI.T.P.N8/3
ø1/v802
EZISNEVO
ELBALIAVAEGATLOV
stnelaviuqecirtemnidetatserasaeradedahS
* Contact factory for information not listed, 3-phase (3ø) figures shown are for 4-wire service, non-reversing.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice
or obligation.
5
ø1/v042 ø3/v614
wk0.4 wk4.5 wk1.8
ø3/zH05/v614,ø1/zH05/v042
rh/lack080,01
,ø1/zH06/v8021/zH06/v042
Page 10
Specifications
D20
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or
obligation.
6
Page 11
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1­LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).
A. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer.
IMPORTANT: Dryer must be transported and handled in an upright position at ALL times.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. To unskid the dryer, locate and remove the two (2) bolts securing the base of the dryer to the wooden skid.
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4) leveling legs, so that the dryer will slide on the legs instead of the base frame.
7
Page 12
B. LOCATION REQUIREMENTS
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1­M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing).
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.
IMPORTANT: “The dryer must be installed on noncombustible floors only.”
2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
3. The dryer is for use in noncombustible locations.
4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements in
5. Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer
Enclosure Requirements in Section C).
Section D).
6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).
7. Dryer must be exhausted to the outdoors as noted in this manual (refer to Exhaust Requirements in Section E).
8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.
9. The dryer must be installed with a proper exhaust duct connection to the outside.
10. The dryer must be installed with provisions for adequate combustion and make-up air supply.
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.
8
Page 13
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 6-inches (15.24 cm) above the dryer’s outer top; except along the front of the dryer which may be closed if desired.
NOTE: Allowances must be made for opening the control door.
X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance.
NOTE: Air considerations are important for proper and efficient operation.
Dryers may be positioned sidewall to sidewall. However, a 1/16” (1.5875 mm) minimum allowance must be made for the opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about 2 feet (0.61 meters) away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back guard). Refer to the illustration above for details.
9
Page 14
D. FRESH AIR SUPPLY REQUIREMENTS
The D20 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1/4 square feet (0.023 square meters) is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It necessary to have a separate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to the dryers. The dryer must be installed with provisions for adequate combustion and make-up air supply.
EXAMPLE: For a bank of eight (8) dryers, two (2) unrestricted openings measuring 1 foot by 1
foot (0.31 meters by 0.31 meters), (1 square foot [0.93 square meters]) are acceptable.
is not
IMPORTANT: Make-up air openings should not be located in an area directly near where exhaust
vents exit the building.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas.
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components.
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.
10
Page 15
E. EXHAUST REQUIREMENTS
DO NOT use a nonmetal flexible vent or a metal vent that is smaller than 4” (10.2 cm) in diameter or exhaust hoods with magnetic latches.
DO NOT exhaust dryer into a chimney, furnace, cold air vent, attic, crawl space, or any other vent used for venting.
DO NOT install flexible vent in enclosed walls, ceilings, or floors.
IMPORTANT: Observe ALL governing codes and ordinances.
Exhaust your dryer to the outside. Moisture and lint indoors may cause:
1. Lint to gather around the dryer where it can be fuel for a fire.
2. Moisture damage to woodwork, furniture, paint, wallpaper, carpet, etc...
3. Housecleaning problems and health problems.
A 4” (10.2 cm) diameter vent is required. A rigid or flexible metal vent must be used. DO NOT use a plastic or a foil covered vent.
Use a heavy metal vent. DO NOT use a plastic or metal foil vent. A rigid metal vent is recommended to prevent crushing and kinking. A flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible vent to avoid sagging and kinking that may result in reduced airflow.
If using an existing exhaust system, clean lint from entire length of system and make exhaust hood with lint. Replace any vinyl or metallized plastic foil vent with rigid metal or flexible metal vent.
Use duct tape to seal ALL joints. DO NOT use screws or other fastening devices that extend into the interior of the vent to secure vent.
Service check: Back pressure in any exhaust system used must not exceed 0.6 inches (1.49 mb) water column (W.C.) measured with an incline manometer at the point that exhaust vent connects to the dryer.
is not plugged
11
Page 16
12
Page 17
IMPORTANT VENTING REMINDERS
1. Ductwork size and installation should be done by a qualified professional.
2. The dryer must be exhausted to the outdoors.
3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible.
4. Avoid 90° turns, use 30° or 45° turns instead.
5. The inside of the ductwork should be as smooth as possible with no projections from sheet metal screws.
Ducts added should overlap the duct to which it is to be connected.
6.
ALL ducts should be taped to prevent moisture and lint from escaping into the building.
7. Inspection or clean out doors should be installed throughout strategic points in the ductwork for periodic
inspection and cleaning.
8. Wherever the ductwork passes through combustible materials, the opening must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
9. The outside of the ductwork must be protected from the weather. A 90° elbow must be used for horizontal
run and when vertically through a roof by using a 180° turn to point the opening downward. The distance between the exhaust duct and the nearest obstruction (i.e., roof or ground) must be twice the diameter of the duct.
10. DO NOT use screens, louvers, or caps on the outside opening of the exhaust ductwork.
11. Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0
and must not exceed 0.6 inches (1.49 mb) of water column (W.C.).
WARNING: DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN
IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.
12. Exhaust ductwork outlets should not be located in an area directly where the make-up air openings are
located.
IMPORTANT: It is recommended that exhaust or booster fans not be used in the exhaust ductwork
system.
13
Page 18
F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
ALL electrical connections made by a properly licensed and competent
ALL electrical connections, materials, and workmanship must
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
IMPORTANT: Each circuit must be connected to an independently protected branch circuit.
IMPORTANT: USE ONLY COPPER CONDUCTOR CABLE of proper ampacity and insulation in
accordance with electric codes for making service connections.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
IMPORTANT: A separate circuit servicing each dryer must be provided.
2. Electrical Service Specifications
a. Electric Service
1) Gas Models ONLY
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left area of the inner back panel.
IMPORTANT: USE ONLY COPPER CONDUCTOR CABLE of proper ampacity and insulation in
accordance with electric codes for making service connections.
NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.
14
Page 19
2) Electric Models ONLY
ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label, which is affixed to the upper left area of the inner back panel. The connecting wires must be properly sized to handle the rated current.
NOTE: Electrically heated service (amperage) specifications/requirements are not available at the time
of printing. Contact factory for update.
NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.
3. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a gas pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection ALL the way to the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or other insulating connectors, they must be jumped out with no. 4 copper wire and securely clamped to bare metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4. Electrical Connections
A wiring diagram is located inside the rear electric box.
NOTE: A CIRCUIT SERVICING EACH DRYER
MUST BE PROVIDED.
The electrical input connections on ALL dryers are made into the rear service box located at the upper right area of the dryer.
15
Page 20
a. Gas Models Only
1) Single-Phase (1ø) Wiring Connections/Hookup
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
16
Page 21
b. Electric Models Only
1) Single-Phase (1ø) Wiring Connections/Hookup
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
17
Page 22
c. Electric Models Only
1) 3-Phase (3ø) Wiring Connections/Hookup
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
18
Page 23
02D
)REYRDREP(SNOITACIFICEPSECIVRESLACIRTCELE
:SETON .A
.B
.C
Gas
Electric
yehtdesuerasesufnehW ebtsum ssalc,gnitimiltnerruc,yaledemit,tnemelelaud
5KRro1KR YLNO rehtiegniylppayb,eulavesuftcerrocenimreted/etaluclaC.
.atadwardpmaecnailppadetsilotsedoClacirtcelElanoitaNro/dnalacol
epytevrucrotom)lairtsudni(citengam-lamrehterasrekaerbtiucriC YLNO roF.
wardpmaecnailppaotgnidroccaezisrekaerbtcerrocyfirev/etaluclac,srehto
.desurekaerbfoepytdnagnitar
sreyrd)Ø3(esahp-3rofsrekaerbtiucriC ebtsum .epytelop-3
ECIVRES
EGATLOV
02129.01---51
8013/22.6---51
0413/2651
04138.5---51
80135.52---53
0413/2---5.8253
04133.82---53
6134---8152
ESAHP
ERIW
ECIVRES
zH06zH05
.XORPPA
WARDPMA
TIUCRIC
REKAERB
IMPORTANT: Figures shown are for non-reversing models ONLY.
IMPORTANT: The wire size must be properly sized to handle the related current.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or
obligation.
19
Page 24
G. GAS INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes,
ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.
IMPORTANT: FAILURE TO COMPLY WITH CODES OR ORDINANCES, AND/OR
REQUIREMENTS IN THIS MANUAL, CAN RESULT IN PERSONAL INJURY AND IMPROPER OPERATION OF THE DRYER.
The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer must be isolated from the gas supply piping system by closing an external manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted can cause irreparable
damage to the gas valve, which will VOID THE WARRANTY.
WARNING: FIRE OR EXPLOSION COULD RESULT.
1. Gas Supply
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances and must be done by a qualified professional.
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and
can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated on the dryer data label affixed to the upper left area of the inner back panel. If this information does not agree with the type of gas available, DO NOT
operate the dryer. Contact the reseller who sold the dryer.
IMPORTANT: Any burner changes or conversions must be made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters), unless elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (609.6 meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller who sold the dryer.
20
Page 25
2. Technical Gas Data
a. Gas Specifications
LARUTANENATUBENAPORPDIUQIL
02G52G03G13G
*erusserPdlofinaMbm7.8bm21.bm03ot82bm43
erusserPylppuSbm0.21bm52.bm03bm73
* Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections
Inlet connection ------------- 3/8” N.P.T. Inlet supply size ------------- 3/8” N.P.T. (minimum) Btu/hr input (per dryer) ---- 40,000 (10,080 kcal/hr)
SAGFOEPYT
LEDOM
REBMUN
02D 080,01 113#868041294#968041016388
* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas ........................ #31 = 3.048 mm.
Liquid Propane Gas ........... #49 = 1.8542 mm.
rh/lack
gnitaR
.ytQ*.S.M.D
)52Gdna02G(larutaNenatuBdnaenaporPdiuqiL
traP
rebmuN
.ytQ*.S.M.D
SAGFOEPYT
traP
rebmuN
enatuBdna.P.L
noisrevnoC
tiK
rebmuNtraP
21
Page 26
Piping Connections
3.
ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance BTUs being supplied.
The dryer is provided with a 3/8-inch N.P.T. inlet pipe connection located at the right side of the base of the dryer. The minimum pipe size (supply line) to the dryer is 3/8-inch N.P.T. For ease in servicing, the gas supply line of each dryer must have its own shutoff valve.
IMPORTANT: The gas supply line to each dryer must be a minimum of 3/8-inch (9.5 mm). DO
NOT REDUCE THIS PIPE SIZE REQUIREMENT.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in
erratic operation of the burner ignition system.
22
Page 27
Consistent gas pressure is essential at pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pressure. Refer to the illustrations on the previous page.
ALL gas connections. It is recommended that a 1/2-inch (12.7 mm)
NOTE: A water column test pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb)
for liquid propane (L.P.) dryers is required at the gas valve pressure tap of each dryer for proper and safe operation.
A 1/8-inch N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply line immediately upstream of each dryer.
IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used.
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid
detergent works well).
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!
ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST
EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance BTUs being supplied.
IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
23
Page 28
H. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1. Read
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to
3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the dryer
4. GAS AND ELECTRIC MODELS - the sail switch damper assembly was installed and adjusted at the
5. Check bolts, nuts, screws, terminals, and fittings for tightness.
6. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.
7. Check that the back guard panel and the electrical box cover have been replaced.
8. Check the lint drawer to assure that it is closed and secured in place.
ALLCAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.
the left side panel area behind the top control (access) door.
data label.
factory prior to shipping. However, each sail switch adjustment must be checked to assure that this important safety control is functioning.
IMPORTANT: If during installation the lint door safety chain was disconnected, it must be
reconnected or personal injury may result.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10. Check terminals and fittings for security.
24
Page 29
I. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Refer to the Operating Instructions for starting your particular model dryer.
3. GAS MODELS ONLY
a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition
attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.
NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.
NOTE: Gas model dryers are equipped with a Direct Spark Ignition (DSI) system, which has internal
diagnostics. If ignition is not established after the first attempt, the heat circuit in the DSI module will lockout until it is manually reset. To reset the DSI system, open and close the main door and restart the dryer.
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be
regulated at the source (L.P. tank), or an external regulator must be added to each dryer.
4. Make a complete operational check of ALL safety related circuits:
a. Door Switch(es)
b. Hi-Limit Thermostats
c. Cycling Thermostat
d. GAS AND ELECTRIC MODELS ONLY - Sail Switch
NOTE: The sail switch can be checked for proper operation by opening the lint door while heating
circuit (gas burner/electric oven) is active (on). The heating unit should shut off within a few seconds. If not, make necessary adjustments to the sail switch.
5. Make a complete operational check of ALL operating controls.
NOTE: If computer program changes are required, refer to the computer programming section of the
manual supplied with the dryer.
6. The dryer should be operated through one (1) complete cycle to assure that ALL components are functioning properly.
25
Page 30
J. SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS...discontinue the gas supply.
1) SHUT OFF
external gas supply shutoff valve.
26
Page 31
SECTION IV
SERVICE/PARTS INFORMATION
A. SERVICE
1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the equipment was purchased.
NOTE: When contacting the Reseller’s Service Department, be sure to give them the correct model
number and serial number so that your inquiry is handled in an expeditious manner.
B. PARTS
1. Replacement parts should be purchased from the reseller from whom the equipment was purchased.
NOTE: When ordering replacement parts from the reseller be sure to give them the correct
model number and serial number so that your parts order can be processed in an
expeditious manner.
27
Page 32
SECTION V
WARRANTY INFORMATION
A. RETURNING WARRANTY CARDS
1. Before any dryer leaves the factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file a warranty claim.
IMPORTANT: A separate warranty card must be completed and returned for each individual dryer.
NOTE: Be sure to include the installation date when returning the warranty card(s).
B. WARRANTY
For a copy of the commercial warranty covering your particular dryer(s), contact the reseller from whom you purchased the equipment and request a dryer warranty form.
NOTE: Whenever contacting the reseller for warranty information, be sure to have the dryer’s model
number and serial number available so that your inquiry can be handled in an expeditious
manner.
28
Page 33
SECTION VI
ROUTINE MAINTENANCE
A. CLEANING
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper air circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, an ADC dryer will provide many years of efficient, trouble free, and most importantly, safe operation.
WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE
ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE HAZARD.
WARNING: KEEP DRYER AREA CLEAR AND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
NOTE: Suggested time intervals shown are for average usage which is considered six (6) to eight (8)
operational (running) hours per day.
IMPORTANT: Dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.
SUGGESTED CLEANING SCHEDULE
EVERY THIRD OR FOURTH LOAD
Clean the lint drawer every third or fourth load. A clogged lint drawer will cause poor dryer performance. The lint drawer is located on the lower front of the dryer. Inspect lint screen and replace if torn.
NOTE: The frequency of cleaning the lint drawer can best be determined from experience at each
location.
WEEKLY
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor (sensor bracket) area.
WARNING: TO AVOID THE HAZARD OF ELECTRICAL SHOCK, DISCONTINUE
ELECTRICAL SUPPLY TO THE DRYER.
29
Page 34
90 DAYS
Inspect and remove lint accumulation in customer furnished exhaust ductwork system from dryer’s internal exhaust ducting.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD.
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION
AIR.
NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
30
Page 35
A. DATA LABEL
SECTION VII
DATA LABEL INFORMATION
When contacting the reseller certain information is required to insure proper service/parts information. This information is on the data label located on the left side panel area behind the control (access) door. When contacting the reseller please have the model number and serial number available.
31
Page 36
THE DATA LABEL
1. MODEL NUMBER The model number is a manufacturers number, which describes the size of the dryer and the type of heat (gas, electric, or steam).
2. SERIAL NUMBER The serial number allows the manufacturer to gather information on your particular dryer.
3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by the manufacturer, which de­scribes
ALL possible options on your particular model.
4. TYPE OF HEAT This describes the type of heat for your particular dryer: gas (either natural gas or liquid propane [L.P.] gas) or steam.
5. HEAT INPUT (for GAS DRYERS) This describes the heat input in British Thermal Units per Hour (BTUH).
6. ORIFICE SIZE (for GAS DRYERS) Gives the number drill size used.
7. ELECTRIC SERVICE This describes the electric service for your particular model.
8. GAS MANIFOLD PRESSURE (for GAS DRYERS) This describes the manifold pressure taken at the gas valve tap.
9. APPLICABLE APPROVAL SEAL(S) I.E., Canadian Standards Association International.
32
Page 37
ADC 113396 1 - 10/30/02-25 2*12/03/02-250