WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
●
Do not try to light any appliance.
●
Do not touch any electrical switch;
do not use any phone in your
building.
●
Clear the room, building or area of
all occupants.
●
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
●
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de
bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d’incendie ou d’explosion ou pour
éviter tout dommage matériel, toute
blessure ou la mort.
—Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
●
Ne pas tenter d’allumer d’appareils.
●
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
●
Évacuez la pièce, le bâtiment ou la
zone.
●
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
●
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L’installation et l’entretien doivent être
assurés par un installateur ou un
service d’entretien qualifié ou par le
fournisseur de gaz.
Retain This Manual in a Safe Place for Future Reference
This product embodies advanced concepts in engineering, design, and safety. If this product is properly
maintained, it will provide many years of safe, efficient, and trouble free operation.
Only qualified technicians should service this equipment.
OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation
manual included with the dryer.
The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.
FOR YOUR SAFETY
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
We have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer
reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and
material, and to change or discontinue models. The illustrations included in this manual may not depict your particular
dryer exactly.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
IMPORTANT
For your convenience, log the following information:
DATE OF PURCHASE ________________________________________________ MODEL NO. ______________________
RESELLER’S NAME __________________________________________________________________________________
SERIAL NUMBER(S) __________________________________________________________________________________
Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the
factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts
Department at +1 (508) 678-9000. Please specify the dryer model number and serial number in addition to the
description and part number, so that your order is processed accurately and promptly.
These instructions are only valid if the following country code is on the appliance… If this code is not present on the
appliance, it is necessary to refer to the technical instructions which will provide the necessary information concerning
the modification of the appliance to the condition of use for the country.
In accordance with EN ISO 3166-1, the names of countries shall be represented by the following codes:
GB United Kingdom
IEIreland
“IMPORTANT NOTE TO PURCHASER”
Information must be obtained from your local gas supplier on the
instructions to be followed if the user smells gas. These
instructions must be posted in a prominent location near the dryer.
2American Dryer Corp.113019-7
!
WARNING
Proposition 65
Use of this product could expose you to
substances from fuel combustion that contain
chemicals known to the State of California
to cause cancer, birth defects and other
reproductive harm.
In the State of Massachusetts, the following
installation instructions apply:
■ Installations and repairs must be performed by
a qualified or licensed contractor, plumber, or
gasfitter qualified or licensed by the State of
Massachusetts.
■ If using a ball valve, it shall be a T-handle type.
■ A flexible gas connector, when used, must not
exceed 3 feet.
IMPORTANT
You must disconnect and lockout the electric supply and
the gas supply or the steam supply before any covers or
guards are removed from the machine to allow access
for cleaning, adjusting, installation, or testing of any
equipment per OSHA standards.
Please observe all safety precautions displayed on the
equipment and/or specified in the installation manual
included with the dryer.
CAUTION
Dryer(s) should never be left unattended while in
operation.
“Caution: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
operation.”
«Attention: Au moment de l’entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des
erreurs de câblage peuvent entraîner un fonctionnement
inadéquat et dangereux.»
WARNING
Children should not be allowed to play on or near the
dryer(s). Children should be supervised if near dryer(s)
in operation.
Under no circumstances should the dryer door switch,
lint door switch, or heat safety circuit ever be disabled.
Do not modify this appliance.
The dryer must never be operated with any of the back
guards, outer tops, or service panels removed. Personal
injury or fire could result.
The dryer must never be operated without the lint filter/
screen in place, even if an external lint collection system
is used.
If the hi-limit switch trips, a service call is required to
investigate the reason and resolve the issue.
FOR YOUR SAFETY
Do not dry mop heads in the dryer. Do not use dryer
in the presence of dry cleaning fumes.
The dryers must not be installed or stored in an area
where it will be exposed to water and/or weather.
The wiring diagram for the dryer is located in the front
electrical control box area.
D.M.S. Drill Measurement Size
HVACHeating, Ventilating, and Air-Conditioning
in WCInches of Water Column
L.C.D.Liquid Crystal Display
L.E.D.Light Emitting Diode
L.P.Liquid Propane
OSHAOccupational Safety and Health Administration
R.M.A. Return Material Authorization
ULUnderwriters Laboratory
113019-7www.adclaundry.com3
Safety Precautions ___________________
!
WARNING
For your safety, the information in this manual must
be followed to minimize the risk of fire or explosion
or to prevent property damage, personal injury, or loss
of life.
The dryer must never be operated with any of the back
guards, outer tops, or service panels removed.
Personal injury or fire could result.
A program should be established for the inspection and
cleaning of lint in the burner area, exhaust ductwork, and area
around the back of the dryer. The frequency of inspection
and cleaning can best be determined from experience at each
location.
!
WARNING
The collection of lint in the burner area and exhaust
ductwork can create a potential fire hazard.
Keep dryer area clear and free from combustible materials,
gasoline, and other flammable vapors and liquids.
Do not spray aerosols in the vicinity of this appliance while it
is in operation.
Purchaser/user should consult the local gas supplier for proper
instructions to be followed in the event the user smells gas.
The instructions should be posted in a prominent location.
What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Clear the room, building, or area of all occupants.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency, or gas supplier.
Dryers must be exhausted to the outdoors.
Although the manufacturer produces a very versatile dryer,
there are some articles that, due to fabric composition or
cleaning method, should not be dried in it.
For personal safety, the dryer must be electrically grounded
in accordance with local codes and/or the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada,
the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990
or LATEST EDITION.
NOTE: Failure to electrically ground the dryer properly will
void the warranty.
Under no circumstances should the dryer door switch, lint door
switch, or heat safety circuit ever be disabled.
!
WARNING
Personal injury or fire could result should the dryer
door switch, lint door switch, or heat safety circuit
ever be disabled.
This dryer is not to be used in the presence of dry cleaning
solvents or fumes.
Remove articles from the dryer as soon as the drying cycle
has been completed.
!
WARNING
Articles left in the dryer after the drying and cooling
cycles have been completed can create a fire hazard.
!
WARNING
Dry only water washed fabrics. Do not dry articles
spotted or washed in dry cleaning solvents,
combustible detergents, industrial chemicals, or “all
purpose” cleaner. Explosion could result.
Do not dry rags or articles coated or contaminated
with gasoline, kerosene, oil, paint, or wax. Explosion
could result.
Do not dry mop heads. Contamination by wax or
flammable solvents will create a fire hazard.
Do not use heat for drying articles that contain plastic,
foam, sponge rubber, or similarly textured rubber
materials. Drying in a heated tumbler may damage
plastics or rubber and also may be a fire hazard.
The possible presence of residual quantities of aggressive or
decomposed chemicals in the load may produce damage to
the machine and harmful fumes.
4American Dryer Corp.113019-7
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors cause improper and
dangerous operation. Verify proper operation after
servicing.
Read and follow all caution and direction labels attached to
the dryer.
For safety, proper operation, and optimum performance, the
dryer must not be operated with a load less than sixty-six
percent, 20 lb (9.1 kg) of its rated capacity.
!
WARNING
You must disconnect and lockout the electric supply
and the gas supply or the steam supply before any
covers or guards are removed from the machine to
allow access for cleaning, adjusting, installation, or
testing of any equipment per OSHA standards.
IMPORTANT: The dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).
!
WARNING
Disconnect power before resetting the hi-limit. The
hi-limit is located on the rear opening of the lint
compartment. Press and release and the hi-limit will
reset.
CE ONL Y
IMPORTANT: This appliance must only be installed and
operated in the country of destination indicated on the
dryer’s data plate. If the appliance is to be installed and
operated in a country other than the one indicated on the
data plate, a data plate amendment must be obtained from
American Dryer Corporation.
MAXIMUM CAPACITY (DRY WEIGHT) PER POCKET30 lb
TUMBLER DIAMETER30”
TUMBLER DEPTH27”
TUMBLER VOLUME PER POCKET11 cu ft
TUMBLER / DRIVE MOTOR PER POCKET1/4 hp
BLOWER / FAN MOTOR PER POCKET1/2 hp
DOOR OPENING (DIAMETER)21-1/2”
DOOR SILL HEIGHT TOP POCKET / BOTTOM POCKET
DRYERS PER 20’ / 40’ CONTAINER14 / 28
DRYERS PER 48’ / 53’ TRUCK36 / 42
VOLTAGE AVAILABLE120-240V 1ø 2w 50/60 Hz
APPROXIMATE NET WEIGHT520 lb
APPROXIMATE SHIPPING WEIGHT550 lb
AIRFLOW PER POCKET
GAS
HEAT INPUTPER POCKET72,000 Btu/hr
EXHAUST CONNECTION (DIAMETER) PER DRYER8”
INLET PIPE CONNECTION PER DRYER1/2” M.N.P.T.
Shaded areas are stated in metric equivalents4/10/14
60 Hz
50 Hz
51-3/4” / 13-1/8”
450 cfm
375 cfm
1/2” B.S.P.T. (CE and Australia Only)
13.6 kg
76.2 cm
68.5 cm
311.5 L
0.19 kW
0.37 kW
54.6 cm
131.4 cm / 33.3 cm
236 kg
249 kg
12.74 cmm
10.6 cmm
18,144 kcal/hr
20.3 cm
NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
6American Dryer Corp.113019-7
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.