specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indi­rect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
Caution: Fog Machines may set o Smoke Alarms!
User Instructions
10/13
Fog Fury 3000 Introduction
Fog Fury 3000 Safety Precautions
Introduction: Congratulations, you have just purchased one of the
most reliable fog machines on the market today! The Fog Fury 3000 commercial fog machine have been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and
understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
Customer Support: ADJ Products, LLC provides a toll free customer
support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. For service related issue please contact ADJ Products, LLC. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
Do not discard the shipping cartoon in the trash. Please recycle when ever possible.
SAFETY ISSUES:
NEVER POINT OR AIM A FOG MACHINE TOWARDS PEOPLE OR THEIR CLOTHING. THIS UNIT EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE WHEN USING AN ELECTRIC KETTLE OR IRON.
Please Note: Specications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
• Be sure to save the packing carton in the unlikely event the unit may have to be returned for service
• Do not spill water or other liquids into or on to your fogger. Be sure that all the fog uid is kept inside the uid reservoir
• Be sure that the local power outlet match that or the required voltage for your fog machine
• Do not remove the top cover under any conditions. There are no user serviceable parts inside
• Disconnect the unit’s main power when left unused for long peri-
ods of time
• Never connect this unit to a dimmer pack
• Do not attempt to operate this unit, if it becomes damaged in anyway
• Never operate this unit when it’s cover is removed
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not attempt to operate this unit if the power cord has been fray­ ed or broken. Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short
• Disconnect from main power before making any type of connection
• Never block the ventilation holes. Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall
• This unit is intended for indoor use only, use of this product out­ doors voids all warranties
• Always mount this unit in a safe and stable matter
• Please route your power cord out of the way of foot trac. Power cords should be routed so they are not likely to be walked on, pinched by items placed upon or against them
• The unit should only be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the unit. C. The unit has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a marked change in performance.
ADJ Products, LLC - www.adj.com - Fog Fury 3000 Instruction Manual Page 2
ADJ Products, LLC - www.adj.com - Fog Fury 3000 Instruction Manual Page 3
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
Fog Fury 3000 DMX Information Fog Fury 3000 DMX Information
Power Supply: Before plugging your unit in, be sure the source volt-
age in your area matches the required voltage for your ADJ Fog Fury
3000. The ADJ Fog Fury 3000 is available in a 120v and 230v version. Because line voltage may vary from venue to venue, you should be sure your unit voltage matches the wall outlet voltage before attempt­ing to operate you xture.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The Fog Fury 3000 can be controlled via DMX-512 protocol. The Fog Fury 3000 has 3 DMX channels. The DMX address is set on the back panel. Your unit and your DMX controller require a standard 3-pin XLR connec­tor for data input and data output (Figure 1). We rec­ommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX
cable must be daisy chained and cannot be split.
ADJ Products, LLC - www.adj.com - Fog Fury 3000 Instruction Manual Page 4 ADJ Products, LLC - www.adj.com - Fog Fury 3000 Instruction Manual Page 5
Figure 1
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
1 Ground
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
DMX +
DMX -
XLR Female Socket
2 Cold
3 Hot
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting stan­dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-)
Some manufactures use 5-pin DMX-
3-Pin XLR to 5-Pin XLR Conversion
Pin 1
Pin 2