American Diagnostic Corporation (ADC) ADview Modular Diagnostic Station User Manual

Page 1
User’s Manual
American Diagnostic Corporation
ADview Modular Diagnostic Station
Blood Pressure Device for Automated and Manual
Measurement
Page 2
ii
About this Manual
This manual describes features and uses of the American Diagnostic Corporation ADview a non-invasive, clinical-grade automated device to measure blood pressure, pulse rate and mean arterial pressure. Optional modules to measure temperature and functional oxygen saturation are available, and their use is also described in this manual.
This manual accompanies all the versions of the ADview :
ADview Versions*
Item Name
Item Description
ADview Battery: BP
BP device with rechargeable battery
ADview Battery: BP & Temperature
BP device with temperature and rechargeable battery
ADview Battery: BP & SpO2
BP device with SpO2 and rechargeable battery
ADview Battery: BP, Temperature & SpO2
BP device with SpO2, temperature, and rechargeable battery
* All above versions are available with a Bluetooth wireless communication option.
This document is designed to help you quickly familiarize yourself with your ADview, and subsequently, to use it to its full potential. Dispersed throughout the body of the manual are tips, notes and warnings to enable you to use your ADview easily, safely and effectively.
Changes and Reissues
This manual is identified as Part Number: 93-9000SM-00. Changes occurring between issues of this document are addressed through change information sheets, addenda, or replacement pages. If none of these accompany this manual, the manual is correct as printed.
Should you notice errors or omissions in this manual, please notify us at:
American Diagnostic Corporation 55 Commerce Drive
Hauppauge, New York 11788 USA Phone: 631.273.9600 Fax: 631.273.9659 E-mail: info@adctoday.com
Copyright Information
All content in this manual is the proprietary information of American)Diagnostic)Corporation and is provided solely for purposes of operation, maintenance or service of the ADview. This manual and the ADview described in it are protected under copyright law under which they may not be copied, in whole or in part, without written consent of ADC.
Page 3
iii
ADview is a registered trademark of ADC. All other trademark names are the trademarks of their respective holders.
The information in this manual is furnished for guidance only, is subject to change without notice, and should not be construed as a commitment by ADC. ADC assumes no liability for errors or inaccuracies that may appear in this manual.
© 2010 ADC. All rights reserved.
Page 4
iv
KEYS AND ACRONYMS
Acronyms
Acronyms commonly used in this document include:
APC
An ADC proprietary acronym for “All Purpose Cuff”
BP
Blood pressure
HR
Pulse rate
K-sound
MAP
NIBP
Korotkoff sound
Mean arterial pressure
Non-invasive blood pressure
EMR/EHR
Electronic Medical Records/Electronic Health Records
Document Key
This manual uses the following icons to call attention to specific instructions or guidance.
TIP: A step or process that eases or enhances your use of your ADview device.
NOTE: Indicates something you must do to use your device correctly and
effectively.
CAUTION: Warns you that not following these instructions can cause injury, harm
or serious damage.
Page 5
v
Indications for Use
The ADview NIBP , Temperature, and Pulse Oximeter device is indicated for use in measuring and displaying Systolic and Diastolic blood pressures, pulse rate, temperature, and functional oxygen saturation (SpO2) of adult and pediatric patients in hospitals, medical facilities, clinics, physicians offices, and other sub-acute environments.
User Responsibility
Your ADview product is designed to perform in conformity with the description contained in this operation manual and accompanying labels and inserts, when assembled, operated, maintained and repaired in accordance with the instructions provided. It is your responsibility to:
Check calibration of the device annually.
Never knowingly use a defective device.
Immediately replace parts that are broken, worn, missing, incomplete, damaged or contaminated.
Contact the nearest factory approved service center should repair or replacement become
necessary. A list of approved service centers appears on pages 44-47 or on our website at www.adctoday.com.
Further, the user of the device bears sole responsibility for any malfunction that results from improper use, faulty maintenance, improper repair, damage or alteration by anyone other than ADC or authorized service personnel.
Warnings and Contraindications
Please read this manual thoroughly before starting to use your ADview. Only those clinicians trained to measure, record and interpret vital signs should use this device.
Do not use this device on pediatric patients under 3 years old, infants, or neonates. The ADview must be charged before using it for the first time.
For accurate blood pressure measurements, ensure that the circumference of the arm fits within the range markings on the cuff.
Page 6
vi
The ADview is not intended for continuous monitoring. Although the blood pressure cuff and cable are defibrillator proof, the temperature probe and SpO2 sensor are not. Do not leave the device unattended while taking measurements on a patient.
Only use such accessories as are recommended for use with this device. A list of recommended accessories is on pages 61-66.
Do not operate the ADview near flammable anesthetics or volatile vapors. An explosion may result.
Compressing the pneumatic tubing may cause system errors.
Do not use the device if it has failed its diagnostic self test or if it displays a greater than zero pressure with no cuff attached or a value of functional oxygen saturation or temperature with no sensor attached.
Prevent water or other fluids from entering any connectors or vents on the device. Should this happen, all connectors should be dried with warm air. Then check the calibration of the device and operating functions before reusing.
Do not make repairs yourself. Equipment must be returned to ADC or authorized service personnel for repairs. Substitution of a component different from that supplied may result in measurement error.
Page 7
vii
If the ADview is dropped or mishandled, please have it checked by a authorized service center before bringing it back into use.
The ADview is not intended for patients connected to a cardiopulmonary bypass machine.
At least every three months, inspect probes, cords and accessories for fraying or other mechanical damage. Replace as necessary.
Check the calibration of your ADview at least once a year.
If Luer Lock connectors are used in the constructions of tubing, there is a possibility that they might be inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel.
Page 8
viii
TABLE OF CONTENTS
Changes and Reissues ........................................................................................................................ ii
Copyright Information ........................................................................................................................ ii
KEYS AND ACRONYMS .......................................................................... IV
Acronyms ................................................................................................................................................ iv
Document Key ........................................................................................................................................ iv
Indications for Use ............................................................................................................................. v
User Responsibility ............................................................................................................................. v
Warnings and Contraindications ......................................................................................................... v
TABLE OF CONTENTS ......................................................................... VIII
GETTING TO KNOW THE
ADVIEW
............................................................. 1
Package Contents .................................................................................................................................... 1
The
ADview
Kit .................................................................................................................................. 1
Accessory Modules ............................................................................................................................ 2
Other Accessories ............................................................................................................................. 2
A Bird’s Eye View ................................................................................................................................... 3
BP module ......................................................................................................................................... 3
BP display ......................................................................................................................................... 4
Optional temperature and pulse oximetry modules ........................................................................... 5
Optional temperature and pulse oximetry displays ............................................................................ 8
Icons and Cues ........................................................................................................................................ 9
Auditory Cues ................................................................................................................................... 9
Visual Cues - Battery Icon ................................................................................................................. 9
Visual Cues - Blood Pressure Module .............................................................................................. 10
Visual Cues - Temperature Module ................................................................................................. 11
Visual Cues - Pulse Oximetry Module .............................................................................................. 12
QUICK START GUIDE ........................................................................... 13
Measuring Blood Pressure and Pulse Rate Automatically ............................................................... 13
Measuring Blood Pressure Using Sphygmode ................................................................................... 13
Measuring Temperature ...................................................................................................................... 13
Measuring Oxygen Saturation ............................................................................................................. 14
SETTING UP THE
ADVIEW
..................................................................... 15
Safety Precautions ................................................................................................................................. 15
Protecting Your Patient .................................................................................................................... 15
Protecting Yourself .......................................................................................................................... 15
Protecting Your
ADview
................................................................................................................... 15
Page 9
ix
Mounting Your Device ......................................................................................................................... 15
Mounting the Device on a Wall ........................................................................................................ 16
Affixing the Device to a Mobile Stand .............................................................................................. 16
Placing the Device on a Tabletop ..................................................................................................... 16
First-Time Setup ................................................................................................................................... 16
Charging the Battery ....................................................................................................................... 16
Connecting Your Device .................................................................................................................. 16
Powering Up .......................................................................................................................................... 17
Selecting Temperature Unit of Measurement ................................................................................... 17
MEASURING BLOOD PRESSURE WITH THE
ADVIEW
.................................... 19
Prepping Your Patient .......................................................................................................................... 19
Selecting the Right Cuff ................................................................................................................... 20
Taking a Measurement ......................................................................................................................... 21
Taking an Automated Measurement ................................................................................................ 21
Taking a Sphygmode Measurement ................................................................................................. 22
K-Sounds: A Primer ............................................................................................................................. 23
MEASURING TEMPERATURE WITH THE
ADVIEW
........................................ 24
Temperature Units of Measurement ................................................................................................ 24
Temperature Measurement Modes .................................................................................................. 24
Using temperature probe and probe covers ..................................................................................... 24
Taking an Oral Temperature .............................................................................................................. 25
Taking an Axillary Temperature ........................................................................................................ 25
Taking a Rectal Temperature .............................................................................................................. 26
MEASURING OXYGEN SATURATION WITH THE
ADVIEW
.............................. 27
Prepping the Patient ............................................................................................................................. 27
Selecting the Right Sensor ............................................................................................................... 27
Protecting Your Pulse Oximetry Sensors .......................................................................................... 27
Guidelines for Use ........................................................................................................................... 27
Measuring Oxygen Saturation with Sensor on Finger ...................................................................... 28
MANAGING READINGS ......................................................................... 30
Recalling the Last Set of Readings ...................................................................................................... 30
Clearing the Last Set of Readings ....................................................................................................... 30
MAINTAINING THE
ADVIEW
.................................................................. 31
Routine Maintenance ....................................................................................................................... 31
Cleaning ......................................................................................................................................... 31
Checking the Calibration of Your Device .......................................................................................... 32
Replacing the Rechargeable Battery ................................................................................................. 32
Attaching the Temperature Module ................................................................................................. 34
Page 10
x
Attaching the Pulse Oximetry Module .............................................................................................. 35
Storage, Shutdown, Transport ............................................................................................................ 36
Storage ........................................................................................................................................... 36
Moving Your Device ........................................................................................................................ 36
TROUBLESHOOTING ............................................................................ 38
Troubleshooting - Blood Pressure Module ....................................................................................... 38
Troubleshooting - Temperature Module .......................................................................................... 39
Troubleshooting - Pulse Oximetry Module ...................................................................................... 40
FAQs ...................................................................................................................................................... 42
Web Resources ...................................................................................................................................... 43
Service Centers ...................................................................................................................................... 44
For customers in the Americas ........................................................................................................ 44
For customers in Europe, the Middle East, and Africa ...................................................................... 45
For customers in Asia and the Pacific .............................................................................................. 45
SPECIAL SITUATIONS ........................................................................... 46
Special Situations .................................................................................................................................. 46
Measuring Blood Pressure in Children ............................................................................................. 46
Measuring Blood Pressure in Obese Patients .................................................................................... 46
Measuring Blood Pressure in the Presence of Arrhythmia ................................................................. 46
Measuring Blood Pressure During Pregnancy ................................................................................... 46
Measuring Blood Pressure in the Elderly .......................................................................................... 46
Measuring Blood Pressure in the Emergency Room .......................................................................... 47
Measuring Blood Pressure in the Presence of Orthostatic Hypotension ............................................. 47
APPENDICES ...................................................................................... 48
Specifications ......................................................................................................................................... 48
Compliance ............................................................................................................................................ 49
Safety Requirements ....................................................................................................................... 49
EMC Statement ................................................................................................................................ 49
Symbols .................................................................................................................................................. 50
EU and FCC Regulatory Information ................................................................................................ 55
Limited Warranty ................................................................................................................................. 57
Purchasing Parts and Accessories ....................................................................................................... 58
Page 11
1
GETTING TO KNOW THE
ADVIEW
Your ADview is a model of functionality, offering consistent blood pressure measurements along with reliable temperature and functional oxygen saturation readings.
Package Contents
Upon opening your kit, please ensure that all listed contents are included. If any contents are missing or damaged, please contact ADC.
The
ADview
Kit
The ADview kit contains your rechargeable battery powered device. Your kit will also contain:
An 8-foot blood pressure hose
Adult and large adult size all purpose cuffs
A wall mounting kit or tabletop stand kit (Mobile stand shipped in separate carton)
A 9v AC power supply
A geography specific power cord
A CD with this manual
A quick start guide
To register your product, visit us at www.adctoday.com/adview and follow the links.
The ADview must be plugged in and charged before first use.
Page 12
2
Accessory Modules
Accessory modules that you can purchase from your distributor or ADC to enhance usability of your ADview include:
A temperature module that includes the oral/axillary probe and one box of disposable probe
covers. A rectal probe option is available separately.
A pulse oximetry module with an adult reusable finger sensor and 6-foot sensor extension cable.
Other Accessories
Many other accessories and sources for purchasing them are listed in the Appendix on pages 58-66. A few to note include:
An APC Adult package (contains one each of the following cuff sizes: Small Adult, Adult, and
Large Adult)
An APC Pediatric cuff package (contains one each of the following cuff sizes: Child, Small
Adult, and Adult)
A rectal temperature kit compatible with the temperature module
Page 13
3
A Bird’s Eye View
BP module
Connectors on the main BP module
Power Connector: Connects to the power supply.
Blood Pressure Hose Connector: Connects to the 8-foot pressure hose.
Buttons
The buttons are used for all actions on the interface, and provide tactile feedback when pressed.
Automatic
button
Sphygmode
manual
button
Power button
(recessed)
Blood pressure hose connector
Power connector
(rear panel)
Page 14
4
Buttons on the main BP module
Button Functionality for the BP Module
Button
Device Status
Action
Result
Automatic
Idle
Select for less than 2 seconds
Start an automatic BP measurement.
Select for 2 to 5 seconds
Redisplay last measurement values for all modules.
Select for more than 5 seconds
Clear last measurement values for all modules.
Taking an automatic or Sphygmode BP
Select
Aborts the BP measurement in progress.
In Calibration Check mode
Select
Device exits Calibration Check mode and is ready to take measurements.
Sphygmode
Manual
Idle
Select
Inflates the cuff as long as the button is selected.
Taking a Sphygmode BP
Select
Re-inflates the cuff as long as the button is selected.
Taking an automatic BP
Select
Aborts the BP measurement in progress.
In Calibration Check mode
Select
Device exits Calibration Check mode and is ready to take measurements.
Power
Power off
Select
Turns on the device.
Power on
Select
Turns off the device.
Automatic + Power
Power off
Hold the Automatic button down while selecting the Power button.
Device enters the Calibration Check mode.
Sphygmode Manual + Power
Power off
Hold the Sphygmode button down while selecting the Power button.
Device enables/disables MAP mode.
BP display
Page 15
5
Information on the BP module display
Systolic blood pressure: At the end of a measurement or when the last measurement is recalled,
the patient’s systolic BP is displayed. During a measurement, the cuff pressure is displayed.
Diastolic blood pressure: At the end of a measurement or when the last measurement is recalled,
the patient’s diastolic BP is displayed.
Pulse rate/Mean arterial pressure (MAP): At the end of a measurement or when the last
measurement is recalled, the patient’s pulse rate is displayed. When the MAP feature is enabled, MAP toggles with pulse rate. If the cuff/hose error and warning icons are lit, a status code may appear in this space. See page 39 for details.
Pulse rate icon: When displayed, the value below is the patient’s pulse rate.
Mean arterial pressure icon: When displayed, the value below is the patient’s MAP.
Power level indicator: Displays connection to AC power or the charge level of the battery.
Cuff/hose icon: When displayed, indicates that the cuff and/or pneumatic hose need to be checked
and adjusted in order to take a measurement. See page 38 for details.
Warning icon: When displayed, indicates that the system needs to be checked. See page 38 for
details.
Pressure column: Displays the pressure in the cuff. Each segment represents approximately
10mmHg.
Optional temperature and pulse oximetry modules
Pressure
column
Systolic blood
pressure
Diastolic blood
pressure
Pulse rate/ Mean
arterial
pressure/Status
code
Power level
indicator
Cuff/hose error icon
Warning icon
Pulse rate icon
Mean arterial
pressure icons
Page 16
6
Buttons on the optional temperature module
Temperature units select: Recessed momentary switch that toggles the display between °F and
°C.
Temperature mode select (symbol on button: ): Momentary switch that selects oral vs. axillary
measurements for the oral temperature probe, and selects predictive vs. direct measurement methods for all probes.
Connectors on the optional temperature module
Temperature unit connector: Located on the temperature
module, connects to the temperature probe housed in the temperature probe well.
Temperature units
select (recessed)
Temperature mode
select
SpO2 sensor
connector
Temperature unit connector (not shown)
Temperature probe connector
Page 17
7
Buttons on the optional pulse oximetry module: None
Connectors on the optional pulse oximetry module
SpO2 sensor connector: Connects to a SpO2 extension cable or sensor. See page 60 for compatible
accessories.
Page 18
8
Optional temperature and pulse oximetry displays
Information on the optional temperature module display
Temperature: At the end of a measurement, the patient’s temperature is displayed. During a
measurement, displays the probe type and related information. If the warning icon is lit, displays the status code. See page 39 for details.
Celsius icon: When lit, the value below is displayed in degrees Celsius.
Fahrenheit icon: When lit, the value is displayed in degrees Fahrenheit.
Warning icon: When displayed, indicates that the system needs to be checked. See page 39 for
details.
Celsius icon
Fahrenheit icon
Temperature
Signal quality
SpO2
Warning icon
Warning icon
Page 19
9
Information on the optional pulse oximetry module display
SpO2: At the end of a measurement, the functional oxygen saturation of the patient is displayed. If
the warning icon is lit, displays the status code. See page 40 for details.
Signal quality: During a measurement, indicates the quality of signal from the pulse oximeter
sensor.
Warning icon: When displayed, indicates that the system needs to be checked. See page 40 for
details.
Icons and Cues
Your ADview is designed to provide unambiguous visual and auditory cues before, during and after a measurement. For easy reference, all cues are tabulated in this chapter.
Audible cues, or beeps, identify stages in the measurement cycle.
Icons illuminated within a module’s display indicate measurement modes, processes or warnings.
Auditory Cues
The temperature and BP modules of the ADview are programmed with auditory cues. A listing of these cues appears below.
NUMBER OF BEEPS…
INDICATES…
One short beep after power up or right
before powering down
The device is powered up and ready to use or the device is about to turn off.
One short beep after
taking a measurement
Success – measurement taken.
Three short beeps
BP measurement error. Please check or take another measurement.
Three long beeps
A system error has occurred. Please refer to page 39 for troubleshooting.
One short beep followed
by a long beep
You have aborted this BP measurement.
Visual Cues - Battery Icon
The battery icon indicates the status of the power supply as follows.
ICON/DISPLAY
INDICATES…
Page 20
10
ICON/DISPLAY
INDICATES…
Battery fully charged Battery is charging (segments animated)
Power-off state
As the charge level drops, the segments will be turned off in sequence from the right to the left.
The battery charge is very low. Recharge before using. (segment flashing)
Visual Cues - Blood Pressure Module
Icons and numeric displays on your device assist you in taking quick and accurate readings.
ICON/DISPLAY
INDICATES…
The systolic BP, read in mmHg, displays immediately below this symbol.
The diastolic BP, read in mmHg, displays immediately below this symbol.
Unit of measurement for SYS, DIA, and MAP
Pulse rate, in beats per minute, displays immediately below this symbol.
If this icon is lit on power-up, MAP mode is enabled. After a measurement, this icon is lit when MAP is displayed in the space below.
These letters are displayed in the pulse rate display area when you are checking the device’s calibration.
Indicates an issue associated with the cuff, its position, or connection. Please check the cuff and hose and try again. Additionally, check page 38 for troubleshooting details.
Page 21
11
ICON/DISPLAY
INDICATES…
Warning! The device is unable to take a valid reading. See page 38 for troubleshooting details.
A measurement is in progress. If the column is rising, the cuff is being inflated; if the column is falling, the cuff is deflating. Each segment lit is approximately equivalent to 10 mmHg.
Visual Cues - Temperature Module
ICON/DISPLAY
INDICATES…
Temperature shown in degrees Fahrenheit.
Temperature shown in degrees Celsius.
“Traveling dash” in temperature display
The unit is taking a measurement in predictive measurement mode.
Warning! There is an error in the measurement or module. Please check the status code in the troubleshooting section on page 39 for details and solutions.
The device is set to measure an oral temperature.
The device is set to measure an axillary temperature.
The device is set to measure a rectal temperature.
The unit is taking a measurement in direct measurement mode. The display of alternates with the current probe temperature.
Temperature value flashes
The unit is taking a measurement in direct measurement mode, but the reading is currently out­of-range.
Temperature value flashes in an upward direction
Final measurement is greater than 109.4°F/43.0°C.
Page 22
12
ICON/DISPLAY
INDICATES…
Temperature value flashes in a downward direction
Final measurement is less than 86°F /30.0°C.
Temperature value is steady (no flashing)
This is the final temperature value.
Visual Cues - Pulse Oximetry Module
ICON/DISPLAY
INDICATES…
“Traveling dash” in SpO2 display
The unit is taking a measurement. Warning! Indicates an error in the optional pulse oximetry module. Please refer to the troubleshooting section on page 40.
Indicates signal strength and quality from the pulse oximeter sensor. If there is no measurement and the signal quality is low, try a different site or sensor.
SpO2 value
Indicates the functional oxygen saturation. This area also displays the status code when the warning symbol is lit.
Page 23
13
QUICK START GUIDE
If the device is off, turn it on by depressing the power button on the right side.
Measuring Blood Pressure and Pulse Rate Automatically
1. Wrap an appropriately sized cuff (sizes are tabulated on page 20) snugly around the upper arm
midway between the elbow and shoulder.
2. Ask the patient to stay still and quiet before taking the measurement.
3. Press the automatic button on your unit. The cuff begins to inflate and the cuff pressure is
shown in the systolic display.
4. In about 30-40 seconds, depending on the size of the cuff, you will hear a beep to indicate cycle
completion. The systolic and diastolic values are shown in their respective locations. If MAP mode is enabled, the pulse rate and MAP values will alternate.
Measuring Blood Pressure Using Sphygmode
1. Wrap an appropriately sized cuff (sizes are tabulated on page 20) snugly around the upper arm
midway between the elbow and shoulder.
2. Ask the patient to stay still and quiet.
3. Press and hold the Sphygmode manual button to inflate the cuff. Watch the pressure
displayed and release the button to start deflating the cuff at 3 mmHg/sec. Place your stethoscope on the brachial artery to take a Sphygmode measurement.
If you see the cuff and/or warning icon , you will need to take another measurement. Please refer to the troubleshooting section on page 38.
Measuring Temperature
1. To measure temperature orally, remove the blue probe from its
holder and secure a disposable cover on it. The display shows
the type of measurement, .
Page 24
14
2. Wait for the device to beep before placing the probe carefully under the patient’s tongue as
denoted by the heat pockets shown to the right. The posterior medial sublingual pocket is preferred for accuracy. Hold the probe in place so that its tip maintains tissue contact. Close the
patient’s mouth. During measurement, a “traveling dash” is displayed. In approximately 10­15 seconds, you will hear a long beep and the temperature reading will display.
3. Remove the probe from the patient’s mouth, discard the probe cover by pressing the button on the
end of the probe handle and replace the probe in its holder, ready for the next measurement.
Measuring Oxygen Saturation
1. For the reusable finger sensor, insert the patient’s digit, index
most preferable, into the sensor. You will see a “traveling dash” until a valid reading is available, typically in 10-20 seconds. This reading is displayed along with the signal strength.
When selecting a sensor site, give priority to an extremity free of an arterial catheter, blood pressure cuff or intravascular infusion.
2. Detach the sensor carefully and replace it in the basket. At the end of the measurement, the last
valid reading will flash for 8 seconds and then be displayed for two minutes or until the next measurement.
Page 25
15
SETTING UP THE
ADVIEW
Safety Precautions
As a clinically trained professional using the ADview, your responsibilities include safeguarding your patients, yourself and your equipment. Many setup functions will be performed either only once or very occasionally, and it is important that you pay close attention. Before you set up your ADview, please review these safety guidelines.
Protecting Your Patient
While your ADview is designed for accurate, reliable vital signs measurement for adults and
children, it is not to be used on patients connected to cardiopulmonary bypass machines, patients needing continuous monitoring, or patients under three years of age.
If you feel that a particular blood pressure reading is questionable, use the ADview and your
stethoscope to take a second, Sphygmode reading. If you would like confirmation for an SpO2 or temperature reading, please use an alternate device. After taking confirmatory readings, check the device for proper functioning.
Arrange the power supply and cabling so that it does not constitute a hazard to your patient, your
co-workers or yourself.
Protecting Yourself
Removing the cover or the back of the device can cause electric shocks. Do not attempt to service
your ADview unless you are authorized.
Protecting Your
ADview
Do not use your ADview around flammable substances.
Use only ADC approved accessories to power your ADview. A listing of these is in the Appendix
on page 58.
Use only those batteries supplied by ADC or an authorized service representative.
The ADview must be placed on a stable, slip proof surface. Only recommended hardware should
be used to mount your device to a wall, pole or tabletop carrier.
At no point should the contents of the storage basket exceed 5 lbs. in weight.
Do not immerse the device in water or attempt to gas sterilize or autoclave it.
The reliability of your ADview depends upon conformance with the operation and service
instructions as detailed in this manual.
Mounting Your Device
For convenience, you may mount your unit on the wall or attach it to a mobile stand or a tabletop stand. A storage basket is included and can be used to hold cuffs, boxes of probe covers for the optional temperature module, and SpO2 sensors for the optional pulse oximetry module. All compatible accessories for mounting your ADview can be found in the list starting on page 58. All versions of the ADview can be mounted in the following ways:
Page 26
16
Mounting the Device on a Wall
Mount the ADview on the wall in place of an aneroid manometer. To affix your ADview to the wall:
1. Attach the bracket to the wall using 4 wall screws, and the basket using 2 screws.
2. Attach the wall bracket adapter to the rear panel of the BP device using the 3 screws.
3. Position the adapter onto the rivets of the wall bracket and slide the device down until it locks
into place.
The weight of the contents of the wall-mounted storage basket should never exceed five pounds. Please do not store heavy items in the storage basket.
Affixing the Device to a Mobile Stand
Attaching the ADview to a mobile stand facilitates portability. To mount the ADview to the mobile stand:
1. Assemble the mobile stand according to the manufacturer’s directions.
2. Using the three thumb screws, secure the rear panel of the BP device to
the stand.
Placing the Device on a Tabletop
Use the ADview with the tabletop stand to make it easier to carry with you. To mount the ADview to the tabletop stand:
1. Using the three thumb screws, secure the rear panel of the BP device to the stand.
First-Time Setup
The ADview must be plugged in and charged before first use.
Charging the Battery
The ADview Battery is powered by a rechargeable 6V lead-acid battery or by AC power. To turn the device on for the first time, connect the device to the power supply, then the power supply to an AC mains power source. Leave it connected for 8 to 12 hours to fully charge the battery.
Page 27
17
The charging status is indicated by the rotating sequence of lit segments in the battery icon. When
the battery is fully charged, all segments will be lit . A fully charged battery provides enough power for the device to make at least 200 measurements within a 12-hour period. The battery is guaranteed to last for 200 readings in an 8 hour period per charge.
Connecting Your Device
To maintain the easy readability and streamlined facade of your ADview, all connections are made through the back or sides of the enclosure.
Connectors on the BP enclosure are for:
Blood pressure hose
Power supply
Connectors on the optional modules are for:
A pulse oximetry sensor on the pulse oximetry module
A temperature probe on the temperature module
To connect the ADview:
1. For blood pressure measurements, the blood pressure hose should already be attached to the BP
device. If not, push the open end of the blood pressure hose (one without the plastic connector) over the blood pressure hose connector on the module. Secure the end with the plastic connector to an appropriately sized cuff by twisting the two mating connectors together.
2. For temperature measurements, remove the tape holding the temperature probe in the well, and
place the box of probe covers in the well next to the probe.
3. For SpO2 measurements, attach the pulse oximetry sensor to the extension cable. Flip the
retention clip forward. Then, connect the other end of the extension cable to the connector on the module. Finally, push the clip backward over the SpO2 connector to hold the connector in the module.
4. Connect the power supply to the main BP module. Then, connect the power supply to an AC
mains power source. The device will turn on automatically.
Powering Up
1. Depress the power button located on the right side of the main enclosure. The power-up sequence
begins. All display segments light up for three seconds. A short beep indicates that the ADview is ready.
2. Check the status of the power level indicator. If the power level indicator shows one segment
flashing, connect the device to the power supply before using. You are now ready to use your ADview.
Selecting Temperature Unit of Measurement
Page 28
18
With the device powered on, select the unit of measurement for temperature by depressing the recessed button on the side of the temperature module to toggle between the °C and °F icons. The selected icon will be lit in the display and becomes your default selection.
Bluetooth Wireless Communication
If your ADview has the optional Bluetooth wireless communication capability, please contact your IT administrator for configuration with your EMR/HER system or communication network.
Page 29
19
MEASURING BLOOD PRESSURE WITH THE
ADVIEW
Your ADview device is designed to take accurate blood pressure readings by the oscillometric method. Systolic pressures from 60 to 270 mmHg and diastolic pressures from 30 to 170 mm Hg lie within the range of your device. In most cases, you will be able to take accurate blood pressure (BP) and pulse rate (HR) measurements within 30-40 seconds.
Steps in taking a BP measurement are:
Prepping the patient and attaching the cuff
Taking the measurement
Prepping Your Patient
Ensure that the patient:
Is not wearing any constricting clothing on the selected arm.
Has no injury or tissue damage on the selected arm.
Keeps the cuffed arm at heart level.
Keeps the cuffed arm motion-free and relaxed without any muscle tension in the biceps and
triceps during the measurement.
Does not cross his/her legs for the measurement.
Keep aware of current practices as recommended by the American Heart Association, British Hypertension Society, and other medical practice associations.
1. Ready the patient into a sitting , standing , or supine position. Remember that a
patient’s BP can vary with position.
The stress of being in a clinical situation often causes patients to undergo ‘white coat hypertension,’ leading to higher-than-normal readings. Help your patient to relax as you prepare to take the measurement.
Page 30
20
Selecting the Right Cuff
Your device comes with durable two-piece All Purpose Cuffs (APC) from ADC. Cuffs are available in a range of sizes, from Child to Thigh. Note that your ADview works optimally with APC cuffs.
Using the table below, select a cuff you estimate to be of the right circumference:
2. Wrap the cuff around the patient’s upper arm midway between the elbow and the shoulder.
3. Ensure the ARTERY arrow is over the brachial artery, between the biceps and triceps muscles on
the inside of the arm.
4. Use the range indicator and the INDEX line on the inside of the cuff to check that the
arm circumference falls within the specified range of the cuff. If the arm is within range, this cuff size is correct for your patient. If the measurement is outside the RANGE indicator, use the appropriate larger or smaller cuff and re-check.
Using a cuff that is too small, commonly called undercuffing, can result in overestimating a patient’s BP. Using a cuff that is too large, or overcuffing, can result in underestimating a patient’s BP. For most accurate results, take care in selecting the appropriate size cuff for your patient.
5. Ensure that the BP pressure hose is connected to the cuff. Confirm that the hose is neither
compressed nor kinked.
6. Ask the patient to stay still and quiet before taking the measurement.
Do not place the cuff on an arm currently being used for other procedures such as intravenous infusions or oximetry readings.
Page 31
21
Taking a Measurement
The ADview allows you to take BP measurements automatically like a monitor or manually like a sphygmomanometer using manual Sphygmode™.
In automatic mode, the cuff inflates and deflates automatically. Initial inflation reaches a cuff pressure of 160 mmHg; the cuff then re-inflates as necessary to obtain a reading. Deflation is optimized to reduce measurement time and obtain an accurate result.
In manual Sphygmode, you inflate the cuff manually using the Sphygmode MAN button in place of an inflation bulb of a sphygmomanometer. When you release the Sphygmode MAN button, the cuff automatically deflates at the AHA recommended rate of 3mmHg/sec. Simply use your stethoscope to determine your patient’s blood pressure.
Taking an Automated Measurement
1. With the patient prepped as described earlier (page 19), and the device powered on, depress the
automatic button that is located in front of the BP module and denoted by the cuffed arm icon
. The cuff inflates to approximately 160 mmHg, as indicated in the systolic area of the
display.
2. Once the cuff pressure reaches its target, the device controls the deflation and, in some instances,
re-inflation of the cuff in order to accurately measure BP. The cuff pressure displays in the systolic area and is also indicated by the vertical LED bar to the left. When you hear a single short beep, indicating the end of the measurement cycle, read the systolic and diastolic pressures,
displayed under the SYS and DIA symbols, and the pulse rate, displayed under the symbol.
Want a MAP
reading? NOTE:
MAP available
outside USA
only
By default, your ADview measures systolic and diastolic BP, and HR. To obtain a Mean Arterial Pressure (MAP) reading, hold down the Sphygmode manual button
as you toggle power to on. On power up, the MAP icon lights up on the LED display. Now, once measurements are complete, the display will alternate between HR and MAP. To exit MAP mode, power the device off and again hold down the
Sphygmode manual button as you toggle power to on. On power up, the MAP icon will flash and disappear. MAP will no longer be displayed.
3. If there is an error in obtaining a measurement, indicated by three beeps, please refer to the
troubleshooting tips on page 38 and take the appropriate remedial measure.
Page 32
22
Taking a measurement on each arm helps rule out dissecting aneurysms, coarctation of the aorta, vascular obstruction and possible errors in measurement.1
You can find more tips like this in the American Heart Association’s current scientific statement on recommendations for blood pressure measurement.
Taking a Manual Sphygmode Measurement
1. With the patient prepped as described earlier (page 19), and the device powered on, palpate the
brachial artery at the antecubital fossa. Place your stethoscope over this space.
2. Press and hold the Sphygmode manual button until you inflate the cuff to a level at least 30
mmHg higher than the patient’s systolic pressure.
3. Once the cuff has been inflated to the desired level, release the Sphygmode manual button. The
cuff begins to deflate at approximately 3mmHg/sec and the device displays the cuff pressure.
4. While listening to your stethoscope, note the systolic and diastolic pressures corresponding to the
first and last Korotkoff sounds (K-sounds) heard.
Press the Sphygmode manual button to re-inflate the cuff.
Press the automatic button if you need to rapidly release all the air from the cuff.
1
Circulation. AHA Scientific Statement: Recommendations for Blood Pressure Measurement in Humans and Experimental Animals, Part 1: Blood Pressure Measurement in Humans: A Statement for Professionals From the Subcommittee of Professional and Public Education of the American Heart Associations Council on High Blood Pressure Research. Thomas G. Pickering, MD, DPhil; John E. Hall, PhD; Lawrence J. Appel, MD; Bonita E. Falkner, MD; John Graves, MD; Martha N. Hill, RN, PhD; Daniel W. Jones, MD; Theodore Kurtz, MD; Sheldon G. Sheps, MD; Edward J. Roccella, PhD, MPH, 2005;111:697-716.
Page 33
23
K- Sounds: A Primer
Korotkoff sounds, commonly called K-sounds, are the sounds you detect through your stethoscope when you measure blood pressure with a sphygmomanometer or an aneroid device. Named for the Russian physician who identified them, there are five phases of K-sounds, each phase characterized by a distinct volume and quality of sound.
K-sounds are heard through the stethoscope as the blood pressure cuff deflates. The first sound, K-1, is heard when cuff pressure equals systolic pressure. K-1 is a sharp, tapping sound.
The K-2 phase is characterized by a swishing sound, caused by the swirling currents in the blood as the flow through the artery increases.
In the K-3 phase, there is a resumption of crisp tapping sounds, similar to those heard during phase 1.
An abrupt muffling of sound identifies K-4, the fourth phase.
The end or fifth phase is the point at which sounds cease to be heard altogether.
Systolic pressure is registered at K-1 and diastolic at K-5.
K-4 or K-5? There exists some debate about whether K-4 or K-5 should be recorded as the diastolic BP. In most cases, K-5 is preferred. However, if the sound persists even after the cuff is completely deflated, it is recommended that K-4 be recorded as the diastolic blood pressure.2
You can find more tips like this in the British Hypertension Society’s current guidelines for management of hypertension.
2
B Williams, NR Poulter, MJ Brown, M Davis, GT McInnes, JF Potter, PS Sever, S McG Thom, British Hypertension Society Guidelines, Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society 2004 – BHS IV, Journal of Human Hypertension, 2004 18, 139-
185.
Page 34
24
MEASURING TEMPERATURE WITH THE
ADVIEW
Your ADview device can measure temperature with the optional temperature module. This module enables you to take rapid, accurate temperature measurements ranging from 86°F-109.4°F. Typically, predictive readings are obtained within ten to fifteen seconds, and direct readings within two minutes. The module is equipped with the temperature probe for oral/axillary measurement, color-coded blue. A rectal probe that is color-coded red is optionally available.
Temperature Units of Measurement
The device displays the temperature measurement in:
Celsius
Fahrenheit
To choose a unit of measurement, depress the recessed button on the left side of the temperature module. The icon for the selected unit is illuminated. This is now the default selection.
Temperature Measurement Modes
The device can measure temperature via three modes:
Oral, indicated by on the display and measured using the blue probe
Axillary, indicated by on the display and measured using the blue probe
Rectal, indicated by on the display and measured using the red probe
All three modes can be used for both predictive and direct measurement. In the default predictive mode, your ADview predicts temperature in 10-15 seconds with an accuracy of +/- 0.2 °F (+/- 0.1°C). When a fever is detected, the measurement may last longer. In direct mode, the display continually updates until a stable reading is reached. This mode is used in certain difficult conditions when a predictive reading is not preferred or possible.
Axillary and rectal modes are preferred for children and compromised patients.
Using temperature probe and probe covers
In addition to the safety instructions for your ADview, here are some additional tips on using the probe and probe covers for the optional temperature module:
Use only ADC by SunTech supplied probe covers with this device.
The device and probe covers are non-sterile. Do not use on abraded tissue.
To limit cross contamination, use blue probes for taking oral and axillary temperature only. Use
red probes for rectal temperatures only.
Page 35
25
Dispose used probe covers in accordance with current medical practices or local regulations
regarding disposal of infectious, biological medical waste.
Note that proper placement of the probe is essential to the accuracy of the measurement.
Taking an Oral Temperature
1. Remove the blue probe from its holder and secure a disposable cover on it. The probe pre-
heating process begins with the flashing display of the type of measurement, .
2. After a few seconds, the device will beep to signify that the
probe is ready for placement. After the beep, place the probe carefully under the patient’s tongue as denoted by the heat pockets shown to the right. The posterior medial sublingual pocket is preferred for accuracy. Hold the probe in place so that its tip maintains tissue contact. Close the patient’s mouth.
During measurement, a “traveling dash” is displayed.
3. After 10-15 seconds, a long beep signals the end of the
measurement cycle. The temperature will display for two minutes or until you initiate a new measurement.
4. Remove the probe from the patient, discard the probe cover by pressing the end of the probe
handle, and return the probe to the probe holder. Note the temperature reading.
By default, the predictive method is selected. To select direct measurement from the start, press the temperature mode select button located on left side of the temperature module for three seconds or until you hear two short, quick beeps. When using direct measurement, the display will alternate displaying “dir” and the current probe temperature. A long beep signals the final temperature result.
Taking an Axillary Temperature
1. Remove the blue probe from its holder and secure a disposable
cover on it. The probe pre-heating process begins with the
flashing display of the type of measurement, .
2. Briefly (less than 2 seconds) press the temperature mode select
button until it displays for axillary.
3. After a few seconds, the device will beep to signify that the probe is ready for placement. After
the beep, lift the patient’s upper arm and place the probe high under the patient’s axilla. Apply pressure gently to assure good contact between the probe and axilla, and make sure there is no interference such as clothing. Hold the probe in place so that its tip maintains tissue contact.
Place the arm by the patient’s side. During measurement, a “traveling dash” is displayed.
Note that proper placement of the probe is essential to the accuracy of the
Page 36
26
measurement.
4. After 10-15 seconds, a long beep signals the end of the measurement cycle. The temperature will
display for two minutes or until you initiate a new measurement.
5. Remove the probe, discard the probe cover and place back in the probe holder. Note the
temperature reading.
Taking a Rectal Temperature
1. Remove the blue probe and well by sliding the pieces upward until they detach.
2. Place the red probe in the holder of the red well and the probe
connector in the notched space as shown to the right (see page 35 for detailed instructions). Slide the red well vertically onto the back of the module thus replacing the blue well.
3. Assist patient into a prone (facedown) position and ensure that the
patient is relaxed.
4. Remove the red probe from its holder and secure a disposable cover on it. The probe pre-heating
process begins with the flashing display of .
5. After a few seconds, the device will beep to signify that the probe is ready for placement. After
the beep, separate the patient’s buttocks and apply a thin coat of water-based lubricant for smooth entry of the probe. Insert the probe gently 1 cm inside the sphincter. Tilt the probe to keep it in place and hold it in position to ensure tissue contact. During measurement, a “traveling dash”
is displayed.
Note that proper placement of the probe is essential to the accuracy of the measurement.
6. After 10-15 seconds, a long beep signals the end of the measurement. The result will be displayed
for two minutes or until you initiate a new measurement.
7. Remove the probe, discard the probe cover and place back in the probe holder. Note the reading.
If the temperature reading is out of range, the device will beep and flash the limit that is exceeded. So, if the reading is greater than 109.4°F (43.0°C), “109.4” or “43.0” will flash on the display followed by a sequence of rising LED’s. If the reading is less than
86.0°F (30.0°C), “86.0” or “30.0” will flash on the display followed by a sequence of falling LED’s.
Notched space/ Probe connector
Page 37
27
MEASURING OXYGEN SATURATION WITH THE
ADVIEW
The ADview optional pulse oximeter module measures functional oxygen saturation ranging from 40% to 100%. A signal strength display assists the clinician in the proper placement of the sensor.
The ADview is a spot check device and is not used for patient monitoring. Therefore, there are no SpO2 alarms.
Steps for measuring functional oxygen saturation:
Prepping the patient and affixing the sensor
Taking a reading
Prepping the Patient
Selecting the Right Sensor
Your choice of sensor is affected by many factors including:
Patient’s body weight
Patient activity
Infection control concerns
For most patients greater than 30kg, use an adult sensor; for patients 10-50kg, a pediatric sensor may provide better fit.
Protecting Your Pulse Oximetry Sensors
In addition to the safety instructions for your ADview, here are some additional tips on caring for the sensor of the optional pulse oximetry module:
To prevent damage, do not autoclave or immerse the sensor in liquid.
For peak performance and accurate measurements, do not expose the sensor to excessive ambient
light, electromagnetic interference, dysfunctional hemoglobin, low perfusion, intravascular dyes, finger nail polish and long or artificial finger nails.
Do not use a damaged sensor as it may cause patient injury or equipment failure.
The use of this sensor is contraindicated in patients with allergies to adhesive tape.
Guidelines for Use
Page 38
28
When selecting a sensor site, give priority to an extremity free of an arterial catheter, blood
pressure cuff or intravascular infusion line.
Clean reusable sensors after use.
Ensure that the optical components of the sensor are properly
affixed to the patient and aligned.
Artificial nails, or dark shades of nail polish, may reduce light
transmissions and affect pulse oximetry accuracy. Clean off nail polish or detach artificial nails before applying the sensors.
Secure sensor cable firmly but lightly at the base of the finger.
Inspect the sensor application site at least every 6 to 8 hours to ensure correct sensor alignment
and skin integrity. Patient sensitivity may vary due to medical status or skin condition. Discontinue use of adhesive tape strips if the patient exhibits an allergic reaction to the adhesive materials.
Measuring Oxygen Saturation with Sensor on Finger
For best results, clip the sensor on the index, middle or ring finger, avoiding the little finger or thumb.
1. For the reusable finger sensor, insert the patient’s digit, index
most preferable, into the sensor. Ensure that the tip of the digit touches the rear guide posts of the sensor and the sensor cable extends along the top of the patient’s hand. Secure sensor with wrap, tape or bandage.
SpO2 measurement will begin automatically. Once the SpO2 determination begins, a “traveling
dash” will be displayed until a measurement is determined, usually in 10 seconds. This reading will be updated once per second. SpO2 can be measured without interruption for up to 10 minutes. Along with the functional oxygen saturation value, the signal strength will also display.
2. When you remove the sensor from the patient’s finger, the display will flash the last measurement
for 8 seconds. The measurement will then be displayed for 2 minutes or until another measurement is made. Note the patient’s reading and confirm normal venous return.
After 10 minutes of continuous measurement, the measurement is automatically terminated and status code “01” is displayed. To view the last measurement prior to
automatic termination, press and hold the automatic button for more than two
Page 39
29
seconds (see page 30 for details).
Page 40
30
MANAGING READINGS
Recalling the Last Set of Readings
To redisplay the last set of readings, depress the automatic button on the BP module for more than two seconds until the last reading is displayed. If your ADview has temperature and/or pulse oximetry modules, the last set of readings includes these readings as well. If the last attempted reading resulted in an error and/or warning, then this will be displayed. The device will display dashes if no reading is in memory, a reading was aborted or, the previous BP was a Sphygmode measurement.
For the pulse oximetry module: In the event of the 10-minute measurement timeout, the module will terminate the measurement and status code “01” will display on the main module. The last valid reading recorded at the end of the ten-minute period will be the recalled reading.
Clearing the Last Set of Readings
To clear the values from the last automatic BP measurement and the accessories, press and hold the
automatic button more than 5 seconds. Previous values will be displayed momentarily. Then the display blanks. On redisplay you will see dashes for all the values that have been cleared.
Your ADview displays the most recent set of readings for two minutes. If patient privacy is a concern, you can clear these readings from the display before collecting vital signs from another patient.
Bluetooth Wireless Transmission of Readings
If your ADview has the optional Bluetooth wireless communication capability you may be able to transmit the readings into your EMR/EHR system or communication network. Contact your IT administrator or EMR/EHR vendor for support on configuring your ADview for Bluetooth wireless communication.
Page 41
31
MAINTAINING THE
ADVIEW
Routine Maintenance
Establishing simple care guidelines helps protect the performance and life of your ADview. On a routine basis, you should inspect the device, cables and pneumatic hoses for cracks, fraying or kinks and immediately replace any damaged parts.
Remember to check the calibration of the BP module annually. If available, a biomedical technician may help in maintaining your equipment.
Cleaning
Cleaning the Device
1. Wipe the device with a soft, damp cloth to remove surface dust and dirt.
The ADview device cannot be sterilized. Never immerse the device in any fluid or attempt to employ cleaning fluids or solvents.
Cleaning the Cuffs
1. Between uses, wipe cuff sleeves and the insides of cuffs with a medical grade cleaning agent.
2. Periodically, remove the bladders and machine-wash the cuffs in cold water.
3. Line dry.
Cleaning the SpO2 Sensor
1. Clean sensor and clips with a soft cloth dampened with water, a mild soap solution, or isopropyl
alcohol.
2. Remove all tape residues by rubbing off.
3. Dry sensor and clips thoroughly before re-use.
Never immerse sensor and clips in fluids. Do not pour or spray any liquids on them either. Caustic or abrasive cleaners will cause permanent damage.
Page 42
32
Prying the finger clip sensor to an angle greater than 90° can permanently damage its casing.
Checking the Calibration of Your Device
It is recommended that you check the BP calibration of your ADview once a year. To check calibration:
1. Start with the device powered off. While holding down the automatic button on the front of
the BP module, toggle on the power button on the right side of the main enclosure. The “CAL” message is displayed in the pulse rate display to indicate that the system is in the calibration mode. During this mode, the system pressure displays in the systolic BP display area.
2. Using a T-connector, connect a calibrated pressure reference and control, such as a manometer
and inflation bulb, to the pressure hose connector of the ADview. Contact ADC customer support for details on ordering the calibration kit which includes a T-connector.
3. Compare the pressure reference to the ADview throughout the pressure range, 0 to 270mmHg. If
the difference between the pressure reference and the ADview is no larger than 2mmHg, the ADview is calibrated correctly for operation. If the ADview needs calibrating, contact an authorized service center on page 44.
4. Exit the calibration check by pressing the automatic button again. Once the display shows
dashes as the systolic BP, you are now ready to take a measurement.
It is recommended that you check the temperature calibration of your ADview temperature module annually. A Calibration Plug (see page 58 for details) is available to check accuracy of the technology. It replaces the regular probe and verifies the accuracy of the temperature electronics. Replace the temperature module if error is greater than +/-0.1 C. To check the calibration:
1. Remove the Temperature Well from the Temperature Module.
2. Replace the Temperature Probe with the Calibration Plug.
3. Replace the Temperature Well.
4. Initiate a measurement by inserting and removing the Temperature probe from the well.
5. Verify the accuracy of the measurement.
Probe accuracy can be checked by using the thermometer as you would on a patient in any mode with a cover, but place it in a calibrated water bath. Direct mode is accurate to +/- 0.1 C of the calibrated water bath temperature. Predictive mode accuracy is accurate to +/- 0.2 C of the calibrated water bath temperature.
Replacing the Rechargeable Battery
Replace the battery:
According to your regular maintenance schedule.
When the battery no longer charges.
After heavy use, if necessary.
Page 43
33
To replace the battery:
1. Remove the four screws securing the battery bay door.
2. Carefully remove the battery from the battery bay, being careful not to pull on the wires
attached to the battery terminals.
3. Disconnect the wires from the battery terminals.
4. The rechargeable battery contains lead. Please dispose of the old battery properly.
5. Connect the wires to the terminals of the replacement battery, ensuring the red wire is
attached to the red terminal and the black wire to the black terminal. If the wires are reversed, no damage will occur, however the ADview will not operate. Be sure to use ADC item number 9000BAT for the replacement battery in order to maintain optimum performance.
6. Re-secure the battery bay door with the four screws removed in step 1.
7. Connect the power supply to turn the device on and charge the replacement battery fully
before using.
If the rechargeable battery is disconnected for any reason, the device must be connected to AC mains power via the power supply before the unit will turn on; this is required even if the battery has been properly reconnected.
Disposal
This symbol indicates the device contains materials (such as electrical components) which are hazardous. Please return to ADC for disposal.
Page 44
34
Attaching the Temperature Module
Should you need to attach or remove the temperature module; the following instructions give an overview of its attachment to the BP module. The temperature module attaches to the top of the BP module. It is made up of the following two pieces:
Part A with the display.
Part B, the probe holder, which holds the temperature
probe and probe cover box.
1. Using the power button on the right side of the BP module, ensure that the ADview is off.
2. Remove the cover plate from the top of the BP module.
3. Slide part A of the temperature module along the guides on the top of the
BP module from front to back until it snaps into place. All the segments of the temperature module display will light when the modules have been connected correctly.
B A A
Page 45
35
4. Attach the temperature probe connector to part B as follows: with the black surface facing
downward, hold the probe connector end against the notches on the probe holder, as shown in red (step 1 shown below).
5. Rotate the connector upwards until it snaps securely into place (step 2 shown above). The black
surface faces outward and the cord extends upward.
6. Slide part B onto part A as shown (this connects the temperature probe
connector to the temperature unit connector), and insert the temperature probe into the well.
7. Turn the device on using the power button on the right side of the BP module.
At the end of the start-up sequence, the temperature module display will be blank except for the appropriate temperature unit icon (°F or °C). A short beep indicates that the ADview is ready.
Note: If the temperature module does not appear to be working properly, cycle the power several times using the power button on the right side of the BP module. This will “synchronize” all the modules. The modules are synchronized when, after you turn the power on, all segments on all module displays light simultaneously for 3 to 5 seconds, followed by a short beep, and all displays go to their “ready” state (BP: battery icon and middle segments of the systolic value are lit; Temperature: appropriate temperature units icon is lit; Pulse Oximetry: the “%SpO2” icon is lit).
Attaching the Pulse Oximetry Module
Should you need to attach or remove the pulse oximetry module; the following instructions give an
overview of its attachment to the BP module. The pulse oximetry module attaches to the bottom of the BP
module.
1. Using the power button on the right side of the BP module, ensure that the ADview is off.
2. Remove the cover plate from the bottom of the main BP module.
Temperature unit connector (not shown)
B
A
Page 46
36
3. Slide the pulse oximetry module along the guides on the bottom of the main BP
module from front to back until it snaps into place. All the segments of the pulse oximetry module display will light when the modules have been connected correctly.
4. Turn the device on using the power button on the right side of the BP module.
At the end of the start-up sequence, the pulse oximetry module display will be blank except for the “%SpO2” symbol.
5. Turn the device off. Connect the adult reusable sensor to the 6’ extension cable and then the
cable to the connector on the module. Secure the cable to your device using the retention clip.
6. Turn the device on. All display segments light up for three to five seconds. A short beep
indicates that the ADview is ready.
Note: If the pulse oximetry module does not appear to be working properly, cycle the power several times using the power button on the right side of the BP module. This will “synchronize” all the modules. The modules are synchronized when, after you turn the power on, all segments on all module displays light simultaneously for 3 to 5 seconds, followed by a short beep, and all displays go to their “ready” state (BP: battery icon and middle segments of the systolic value are lit; Temperature: appropriate temperature units icon is lit; Pulse Oximetry: the “%SpO2” icon is lit).
Storage, Shutdown, Transport
Storage
The ADview must be stored between -20°C (-4°F) and 55°C (131°F). Relative humidity must be less than 90%.
If you are storing the ADview Battery for 30 days or longer, it is recommended that you disconnect the battery from the device.
Moving Your Device
To pack your device for repair or transport:
Page 47
37
1. Detach the cuff, temperature probe, SpO2 sensor, power supply, and other ancillary products from
the device.
2. Disconnect the battery and remove it from the device.
3. Place the device in the original shipping carton, preferably with its original packing material.
4. Ensure that the device will be kept at between -20°C (-4°F) and 55°C (131°F) and in relative
humidity less than 90% during transshipment.
Page 48
38
TROUBLESHOOTING
The troubleshooting chart provides pointers on diagnosing issues associated with error or status codes.
Problem: The ADvew will not power on.
Solutions:
1. The ADview must be plugged in to charge before first use.
Problem: My ADview is not communicating with my EMR/EHR system or network
Solutions:
1. Be sure your ADview is equipped with the Bluetooth option.
2. Your ADview and wireless system must be configured to communicate. Refer to your
EMR/EHR operator’s manual or contact your IT administrator or EMR/EHR provider.
3. You may need to move your ADview closer to the wireless system. While the
Bluetooth capability on the ADview has been rated up to a maximum range of 100 m, be sure to minimize walls, structures and other obstacles that may impede wireless connectivity.
Troubleshooting - Blood Pressure Module
Problem: Wrong size cuff, Misplaced cuff, or Blocked brachial artery
Solutions:
1. Check that the cuff is in the correct position.
2. Check that the cuff is properly tightened.
3. Check that there is no excessive clothing between the arm and the cuff.
4. Check that the cuff applied is of the correct size.
5. The patient may have been moving too much.
6. Take another BP reading.
Problem: Too much patient or environment motion or conditions causing tremors
Solutions:
1. Check that the cuff is in the correct position.
2. The patient may have been moving too much.
3. Take another BP reading.
.
Problem: Air leak, Loose cuff, or Blocked or pinched hose
Solutions:
1. Check that the hose has no sharp bends or is pinched.
2. Check that the patient is not lying on the cuff.
3. Check that the cuff is in the correct position.
4. Check that the hose is connected to the system and the cuff.
5. Check that the cuff is properly tightened.
Page 49
39
6. Check that the correct size cuff is being applied.
7. Check that the cuff is not leaking air.
8. Check that the hose connections are not damaged or loose.
9. Take another BP reading.
Status Codes: 800, 900, 910, 970, 980, or 990 Problem: System error
Solutions:
1. Take another measurement.
2. If this is unsuccessful, power down, then power up the unit using the power button on the
right side of the unit. If the error does not recur immediately, take another measurement.
3. If the error recurs, remove power from the unit (unplug any power supplies and remove
the battery, if there is one), then reconnect the power. If the error does not recur immediately, take another measurement.
4. If the error recurs, contact ADC or an authorized service center.
Troubleshooting - Temperature Module
Status Code: 5
Problem: Temperature probe missing or outside of well Solutions:
1. Remove and then place the probe in the well.
2. Ensure that the temperature well (the rear portion of the temperature module) is well
seated on the display. Along the top of the module, the edge of the well should be flush with the display. Remove and carefully slide the well onto the display.
When properly fixed, the error should no longer be displayed. Take a new measurement.
Status Code: 10 Problem: Defective temperature probe Solutions:
1. Remove and then place the probe in the well.
2. Ensure that the temperature well (the rear portion of the temperature module) is well
seated on the display. Along the top of the module, the edge of the well should be flush with the display. Remove and carefully slide the well onto the display.
When properly fixed, the error should no longer be displayed. Turn the device off. After it has shut down, turn it on. The error should no longer be displayed. Take a new measurement.
Status Code: 15 Problem: Stuck button
Solution: Depress the Temperature units select button and/or the Temperature mode select button until the button becomes unstuck. When the button is unstuck, the error will no longer be displayed. If you cannot un-stick the button, contact ADC or an authorized service center.
Page 50
40
Status Code: 20 Problem: Hardware error Solutions:
1. Take another measurement.
2. If this is unsuccessful, power down, then power up the unit using the power button on the
right side of the unit. If the error does not recur immediately, take another measurement.
3. If the error recurs, remove power from the unit (unplug any power supplies and remove
the battery), then reconnect the power. If the error does not recur immediately, take another measurement.
4. If the error recurs, contact ADC or an authorized service center.
Troubleshooting - Pulse Oximetry Module
Status Code: 01 Problem: Measurement time-out. The measurement time exceeded the 10-minute
time limit.
Solution: Remove the sensor from the patient. Redisplay the last measurement prior to the
timeout, or take a new measurement by placing the sensor on the patient.
Status Code: 02 Problem: Poor sensor position (signal is inadequate for a reliable measurement)
Solution: Adjust position of sensor on patient by placing sensor on opposite hand or ear or alternate site. Avoid fingers with nail polish or artificial nails.
Status Code: 05 Problem: The sensor has been disconnected from the device.
Solution: Reconnect the sensor. If you wish, you may leave the sensor disconnected as this code is only displayed once at the time the sensor is disconnected.
Status Code: 10
Problem: Defective sensor Solution: Replace the sensor and take a new measurement.
Status Code: 20 Problem: Hardware error
Solutions:
1. Take another measurement.
2. If this is unsuccessful, power down, then power up the unit using the power button on the
right side of the unit. If the error does not recur immediately, take another measurement.
3. If the error recurs, remove power from the unit (unplug any power supplies and remove
the battery), then reconnect the power. If the error does not recur immediately, take another measurement.
4. If the error recurs, contact ADC or an authorized service center.
Page 51
41
Problem: Inadequate signal strength
Solution: If there is no measurement and the signal quality is low, try a different site or sensor. Avoid fingers with nail polish or artificial nails. If there is no improvement in signal quality, then discontinue use.
Page 52
42
FAQs
Can I obtain replacement copies of the ADview CD and manual?
Copies of the ADview manual are available through the Customer Service area of our website. To download the manual, please visit www.adctoday.com/adview. For a replacement CD, please email Customer Service at info@adctoday.com
How do I clean the ADview device?
The ADview requires only minimal cleaning. Wipe it down occasionally with a soft, damp cloth. Never immerse the device or apply cleaning fluid or solvents.
How do I install the rechargeable battery in the ADview?
Remove the battery bay cover and position the rechargeable battery within, ensuring proper alignment of polarities. Replace the cover securely and connect the device to AC mains power via the power supply to turn the device on. Ensure the battery is fully charged before use. (See page 33 for detailed instructions.)
How often should I calibrate the BP Module for the ADview?
You should check the calibration once a year. If there is a difference larger than 2 mmHg against the pressure reference, then contact an authorized service center on page 46.
How accurate is the ADview blood pressure device?
The ADview, designed for accuracy, has been manufactured to comply with AAMI SP10 protocol, and has been independently validated to both the British Hypertension Society (BHS) and European Society of Hypertension (ESH) standards for clinical accuracy.
What method of blood pressure measurement is used in the ADview?
The ADview takes automated BP measurements using the oscillometric method. It supplements this with the ability to take measurements as you would if you were using a mechanical sphygmomanometer.
Can I upgrade my current version of ADview at a later date?
To upgrade your ADview device, please review the list of accessories on page 58 or on our website. Contact your local distributor for details.
Page 53
43
Could I use the ADview to measure blood pressure during a stress test?
Although your ADview is a robust device that has been manufactured with motion tolerance, it is not intended for use during stress testing.
Should I wait between temperature measurements?
Yes. Accurate temperature measurement requires the probe to be at normal room temperature. After taking a measurement, wait for the probe to return to room temperature or wipe the probe with an alcohol wipe before taking a subsequent measurement.
Do I need to calibrate the temperature or pulse oximetry modules?
For calibration or service on the ADview temperature and pulse oximeter modules, contact an authorized service center on page 46.
How accurately does the ADview temperature module measure temperature?
The ADview temperature module is accurate to +/- 0.2 °F (+/-0.1°C).
What is the accuracy of the ADview pulse oximetry module?
The ADview pulse oximetry module is +/- 2% in the 70 to 100% range for no motion and normal perfusion. For motion or low perfusion, the accuracy is +/- 3%.
When does the warranty period begin?
The warranty for your ADview begins on the date of shipment of your device.
How do I make a warranty claim for the ADview?
Contact an authorized service center on pages 46 - 47.
How do I get my ADview to communicate with my EMR/EHR software system?
You must have the optional Bluetooth capability to allow communication with any EMR/EHR system. Please contact your IT administrator or EMR/EHR system provider about configuring your ADview for communication. Software development kits are available from ADC for EMR/EHR vendors to support communication with the ADview.
Page 54
44
Web Resources
www.adctoday.com/adview
Service Centers
For customers in the Americas
American Diagnostic Corporation Service Department 55 Commerce Drive Hauppauge, NY 11788 USA Tel: 631.273.9600 Fax: 631.273.9659
Page 55
45
For customers in Europe, the Middle East, and Africa
American Diagnostic Corporation Oakfield Estate Eynsham, Oxfordshire England Tel: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235
For customers in Asia and the Pacific
American Diagnostic Corporation Level 19, Two, International Finance Centre 8, Finance Street, Central Hong Kong Tel: +852.2251.1949 Fax: +852.2251.1950
Page 56
46
SPECIAL SITUATIONS
Special Situations
Unique circumstances, such as the patient’s age or physiological disturbances, require you to take special care while measuring blood pressure or vital signs. The more common examples of such circumstances are described here, to assist you in using your ADview optimally under such conditions. You can find recommendations on dealing with each of these special situations in the American Heart Association’s current scientific statement on recommendations for blood pressure measurement or the British Hypertension Society’s current guidelines for management of hypertension.
Measuring Blood Pressure in Children
Typically, children exhibit greater variability in blood pressure than do adults. They are more likely to be crying, eating or restless in a clinical situation, further increasing the potential for variability.
Measuring Blood Pressure in Obese Patients
There appears to be a positive correlation between obesity and hypertension. Due to the increased arm circumference of obese patients, use of a "standard" cuff may lead to blood pressure being erroneously elevated – a condition known as "cuff hypertension."
Selecting an Appropriate Cuff for Obese Patients:
For larger-than-normal upper arms, use a wider and longer cuff than you would otherwise use.
Prominent biceps in a muscular upper arm require a large cuff.
Measuring Blood Pressure in the Presence of Arrhythmia
Irregular cardiac rhythms can result in a large variation in blood pressure from beat-to-beat. If you are using the ADview on a patient with known arrhythmia, we recommend that you follow up with a Sphygmode BP reading as a confirmatory measure.
In patients with severe regular bradycardia, take Sphygmode rather than automatic readings.
Measuring Blood Pressure During Pregnancy
Hypertension is a common medical disorder of pregnancy, occurring in about ten percent of pregnancies. Detection of elevated blood pressure is essential to optimal prenatal care.
For clinically relevant hypertension in pregnancy, use the ADview to take a Sphygmode measurement.
Measuring Blood Pressure in the Elderly
In the elderly, the combination of hypertension and ageing can manifest as a decrease in arterial compliance. Variability in blood pressure can lead to a number of circadian blood pressure patterns that are best identified using ambulatory blood pressure measurement. The clinical consequence of this blood pressure variability is inaccurate readings.
Page 57
47
Measuring Blood Pressure in the Emergency Room
Measuring blood pressure in the emergency room can be done through automated blood pressure measurements. For critically ill or injured patients, blood pressure should be measured through the invasive arterial pressure method.
Measuring Blood Pressure in the Presence of Orthostatic Hypotension
Orthostatic hypotension is defined as a decrease in systolic blood pressure of 20 mmHg or more or diastolic blood pressure of 10 mmHg or more measured after three minutes of standing up from a supine position. Food ingestion, time of day, age, and hydration can impact this form of hypotension, as can a history of Parkinsonism, diabetes, or multiple myeloma.
Page 58
48
APPENDICES
Specifications
Patient population: Adult and pediatric patients (age 3 and above).
Method of measurement: Oscillometric
Initial inflation pressure: 160mmHg +/- 20mmHg
Blood pressure range (mmHg): 60< Systolic BP< 270, 30< Diastolic BP< 170
Blood pressure accuracy: Measurements determined with this device are equivalent to those obtained by a
trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Manual, electronic or automated sphygmomanometers.
Blood pressure determination time: 30-40 seconds typical for Adult cuff
Pulse rate range: 30-200 bpm +/- 2% or +/- 3 bpm, whichever is greater
Temperature range: 86°F (30.0°C) – 109.4°F (43.0°C)
Temperature accuracy: +/- 0.2°F (+/-0.1°C)
Functional oxygen saturation range: 40-100%
Functional oxygen saturation accuracy: 70-100% +/- 2 digits
(Note: because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of pulse oximeter equipment measurements can be expected to fall within ± 2 digits of the value measured by a CO-oximeter.)
Operating conditions: 10°C (50°F) to 40°C (104°F) Less than 90% RH
Storage conditions: -20°C (-4°F) to 55°C (131°F) Less than 90% RH
Power: External power supply, AC adapter (ADC item number 9000AC9V)
Calibration: Check once per year for BP and Temperature
Page 59
49
Safety systems: Independent hardware over-pressure circuit and redundant software overpressure
algorithm to limit cuff pressure to less than 330 mmHg. Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Length = 5.5 inches, Height = 11.5 inches, Width = 3.8 inches; Length =14.0 cm, Height =
29.2 cm, Width = 9.7 cm
Standards: UL60601-1, CAN/CSA C22.2 601-1
IEC 60601-1, IEC 60601-1-2 (EMC), IEC 60601-1-4, ISO 9919, AAMI SP10:2002, ASTM E 1112, EN 12470-3
Meets EN-1060-1, Specification for non-invasive sphygmomanometers – Part 1: General requirements and EN 1060-3, Non-invasive Sphygmomanometers – Part 3. Supplementary Requirements for Electro-Mechanical BP Measuring Systems”
Classification: Protection against electric shock: Class II (for non-battery version), Internally Powered
Equipment (for battery version); Applied parts: Type BF; Mode of operation: Continuous
IP index: IPX0
Compliance
American Diagnostic Corporation Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK Tel: +44. 1865.884.234 Fax: +44. 1865.884.235
Safety Requirements
Clinical grade BP measurement accuracy defined by fully meeting the requirements of:
AAMI SP-10 2002
EN 1060-4
EMC Statement
Page 60
50
This equipment has been tested and found to comply with the limits for medical devices to IEC60601-1-2:
2001. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. This equipment should not be used adjacent to or stacked with other equipment. If this is necessary, the equipment should be observed to verify normal operation in the configuration in which it will be used. However, even if used properly, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving device
Increase the separation between the equipment
Connect the equipment into an outlet on a circuit different from that to which the other device(s)
are connected
Consult the manufacturer or field service technician for help
Use only ADC-approved cables and accessories with this device. Use of unauthorized cables or accessories may result in increased emissions or decreased immunity. Portable and mobile RF communications equipment can affect Medical Electrical Equipment.
Symbols
The following symbols are associated with the ADview:
SYMBOL
DESCRIPTION
Manufactured by
ETL certified
Power supply contains materials which are hazardous. Must be disposed of properly.
No SpO2 alarm
Attention, consult accompanying documents.
Class II isolation equipment
Page 61
51
SYMBOL
DESCRIPTION
or
CE approval
Recognized component certified by UL to both Canada and US requirements
TUV Canada and US approval
TUV International approval
Earth ground
Output connection configuration – positive voltage; negative shield
Page 62
52
Guidance and manufacturer’s declaration – electromagnetic emissions
The ADview is intended for use in the electromagnetic environment specified below. The customer or the user of the ADview should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment – guidance
RF emissions CISPR 11
Group 1
The ADview uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11
Class B
The ADview is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissions IEC 61000-3-2
Class A
Voltage fluctuations/ flicker emissions IEC 61000-3-3
Complies
Page 63
53
Guidance and manufacturer’s declaration – electromagnetic immunity
The ADview is intended for use in the electromagnetic environment specified below. The customer or the user of the ADview should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment – guidance
Electrostatic discharge (ESD) IEC 61000-4-2
±6 kV contact ±8 kV air
±6 kV contact ±8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Electrical fast transient/burst IEC 61000-4-4
±2 kV for power supply ±1 kV for input/output lines
±2 kV for power supply ±1 kV for input/output lines
Mains power quality should be that of a typical commercial or hospital environment.
Surge IEC 61000-4-5
±1 kV differential mode ±2 kV common mode
±1 kV differential mode ±2 kV common mode
Mains power quality should be that of a typical commercial or hospital environment.
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11
<5% UT (>95% dip in UT for 0, 5 cycle
40% UT (60% dip in
UT) for 5 cycles
70% UT (30% dip in UT) for 25 cycles
<5% UT (>95% dip in UT) for 5 sec
<5% UT (>95% dip in
UT for 0, 5 cycle
40% UT (60% dip in UT) for 5 cycles
70% UT (30% dip in UT) for 25 cycles
<5% UT (>95% dip in UT) for 5 sec
Mains power quality should be that of a typical commercial or hospital environment. If the user of the ADview requires continued operation during power mains interruptions, it is recommended that the ADview be powered from an uninterruptible power supply or a battery.
Power frequency (50/60 Hz) magnetic field IEC 61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields should be at levels characteristic of a typical commercial or hospital environment. NOTE UT is the AC mains voltage prior to application of the test level
In the event of a power loss to the device, all user settings are saved. The device will power-up with the same settings as prior to the power loss. The device does not store patient data.
Page 64
54
Guidance and manufacturer’s declaration – electromagnetic immunity
The ADview device is intended for use in the electromagnetic environment specified below. The customer or the user of the ADview device should assure that it is used in such an environment.
Immunity test
IEC 60601
test level
Compliance
level
Electromagnetic environment - guidance
Conducted RF IEC 61000-4-6
Radiated RF IEC 61000-4-3
3 Vrms 150 kHz to 80 MHz
3V/m 80 MHz to 2.5 GHz
3V
3 V/m
Portable and mobile RF communications equipment should be used no closer to any part of the ADview, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance
d = [3.5/V1] √P
d = [3.5/E1] √P 80MHz to 800MHz d = [7/E1] √P 800MHz to 2.5GHz
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey a, should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1—At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2—These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ADview device is used exceeds the applicable RF compliance level above, the ADview device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re­orienting or relocating the ADview device.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Page 65
55
Recommended separation distances between portable and mobile RF communications equipment
and the ADview device
The ADview device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ADview device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the ADview device as recommended below, according to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d = [3.5/V1] √P
80 MHz to 800 MHz
d = [3.5/V1] √P
800MHz to 2.5GHz
d = [7/E1] P
0.01
0.12
0.12
0.23
0.10
0.38
0.38
0.73 1 1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1—At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2—These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
For units that are Bluetooth enabled, the following EU and FCC regulatory information applies:
EU Regulatory Information
The transmitter module manufactured by Mitsumi and incorporated into the AdView BP module marked by has been approved in accordance with the R&TTE directive.
FCC Regulatory Information
Page 66
56
FCC RF Interference Statement: This equipment has been tested and found to comply with the limits pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and radiates radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains FCC-ID P00WML-C40.
FCC RF Exposure Statement: This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operation instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This mobile modular transmitter must have a separation distance of at least 20 cm between the antenna and the body of the user or nearby persons. With a separation distance of 20 cm or more, the MPE limits are well above the potential this module is capable of producing.
Note: Unauthorized modifications will void the authority to use this equipment.
Page 67
57
Limited Warranty
ADview Device
American Diagnostic Corporation
provides the original purchaser the following limited warranty from date of invoice.
BP, Temp and SPO2 Modules: 2 years parts and labor
Cuffs: 2 years
Wall Mount, Table Caddy and Mobile Stand: 2 years
Battery: 1 year (added)
Cables and all other accessories: 90 days
American Diagnostic Corporation warrants each instrument to be free from defects in material and workmanship. Liability under this warranty covers servicing of the instrument when returned from the customer’s facility within the United States prepaid to the factory. ADC will repair any component(s) or part(s) that it finds to be defective during the period of this limited warranty. Should a defect become apparent, the original purchaser should first notify ADC of the suspected defect. The instrument should be carefully packaged and shipped prepaid to:
For customers in the Americas: American Diagnostic Corporation Service Department 55 Commerce Drive Hauppauge, NY 11788 USA Tel: 631.273.9600 Fax: 631.273.9659
OR
For customers in Europe, Middle East, Africa, Asia, and the Pacific: American Diagnostic Corporation .Service Department Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK Tel: +44. 1865.884.234 Fax: +44. 1865.884.235 The instrument will be repaired in the shortest possible time and returned prepaid by the same shipping method as received by the factory. This limited warranty is void if the instrument has been damaged by accident, misuse, negligence, act of God or serviced by any person not authorized by ADC.
This limited warranty contains the entire obligation of ADC and no other warranties expressed, implied or statutory are given. No representative or employee of ADC is authorized to assume any further liability or grant any further warranties except as herein.
Page 68
58
Purchasing Parts and Accessories
We recommend that you purchase parts and accessories for your ADview from your authorized ADview distributor. A consolidated list of parts and accessories appears below.
ADview Systems
Item #
Item Name
Item Description
9000BPSTO
9000M
ADview Battery Mobile System, BP, Temperature & SpO2
BP Device with SpO2, Temp, Rechargeable Battery and mobile stand & basket
9000BP
9000M
ADview Battery Mobile System, BP
BP Device with Rechargeable Battery and mobile stand & basket
9000BPTO
9000M
ADview Battery Mobile System, BP & Temperature
BP Device with Temp, Rechargeable Battery and mobile stand & basket
9000BPS
9000M
ADview Battery Mobile System, BP & SpO2
BP Device with SpO2, Rechargeable Battery, and mobile stand & basket
9000BPSTO
9000W
ADview Wall System, BP, Temperature & SpO2
BP Device with SpO2, Temp, Rechargeable Battery, and wall mount kit & basket
9000BP
9000W
ADview Wall System, BP
BP Device with Rechargeable Battery and wall mount kit & basket
9000BPTO
9000W
ADview Wall System, BP & Temperature
BP Device with Temp, Rechargeable Battery, and wall mount kit & basket
9000BPS
9000W
ADview Wall System, BP & SpO2
BP Device with SpO
2,
Rechargeable
Battery, and wall mount kit & basket
9000BPSTO
9000D
ADview Battery Tabletop System, BP, Temperature & SpO2
BP Device with SpO2, Temp, Rechargeable Battery, and tabletop stand
9000BP
9000D
ADview Battery Tabletop System, BP
BP Device with Rechargeable Battery and tabletop stand
Page 69
59
9000BPTO
9000D
ADView Battery Tabletop System, BP & Temperature
BP Device with Temp, Rechargeable Battery, and tabletop stand
9000BPS
9000D
ADview Battery Tabletop System, BP & SpO2
BP Device with SpO2, Rechargeable Battery, and tabletop stand
ADview Accessories
Item #
Item Name
Item Description
9000TO
ADview Temperature Module, Oral
Thermometry Module for ADview BP with blue probe
9000TR
ADview Temperature Module, Rectal
Thermometry Module for ADview BP with red probe
9000S
ADview SpO2 Module
SpO2 Module for ADview BP
9000BPCAP
Top/bottom cover for ADview
BP
Covers the top or bottom of a ADview BP device
All Purpose ­General Clinical Use Cuffs
Item #
Item Name
Item Description
9000CK
All Purpose Cuff package, All sizes
Includes Child, Small Adult, Adult, Large Adult, and Thigh cuffs with threaded screw type connectors 9000ACK
All Purpose Cuff package, Adult
Includes Adult, Large Adult, and Thigh cuffs with threaded screw type connectors
9000PCK
All Purpose Cuff package, Pediatric
Includes Child, Small Adult, and Adult cuffs with threaded screw type connectors
850-9000-9CGR
All Purpose Cuff, Child
Blood Pressure Cuff with threaded screw type connector, Range: 12-19 cm, Color: Green
850-9000-10SARB
All Purpose Cuff, Small Adult
Blood Pressure Cuff with threaded screw type connector, Range: 17-25 cm, Color: Royal Blue
Page 70
60
850-9000-11AN
All Purpose Cuff, Adult
Blood Pressure Cuff with threaded screw type connector, Range: 23-33 cm, Color: Navy Blue
850-9000-12XBD
All Purpose Cuff, Large Adult
Blood Pressure Cuff with threaded screw type connector, Range: 31-40 cm, Color: Burgundy
850-9000-13TBR
All Purpose Cuff, Thigh
Blood Pressure Cuff with threaded screw type connector, Range: 38-50 cm, Color: Brown
Pulse Oximetry
Accessories
Item #
Item Name
Item Description
9000SP
Adult digit reusable oximetry sensor (2010)
Reusable finger sensor with 36" (.91 m) cable and DB-9M connector for adults and pediatrics >88 lbs (>40 kg); Nellcor compatible sensor DS-100A
9000SPC
6-foot Extension Cable (2411)
Reusable cables with DB-9 M & F connectors
Thermometry
Accessories
Item #
Item Name
Item Description
9000TR-01
Red Rectal Temperature Kit
Includes rectal probe, well, and box of probe covers
9000TOP
Blue Oral/Axillary Probe
Oral/axillary probe with 9 ft (2.7 m) extended cord
9000TWB
Blue Oral/Axillary Well
Rear piece of the temperature module that holds the oral/axillary probe and box of probe covers
9000TRP
Red Rectal Probe
Rectal probe with 9 ft (2.7 m) extended cord
9000TWR
Red Rectal Well
Rear piece of the temperature module that holds the rectal probe and box of probe covers
9000TP
Disposable Probe Covers
25 boxes (500 probe covers)/case
Page 71
61
Miscellaneous Accessories
Item #
Item Name
Item Description
9000M
Mobile stand kit
Includes base, pole, power supply holder, storage basket, handle, and assembly instructions
9000D
Tabletop stand kit
Includes power supply holder
9000W
Wall mount kit
Includes wall mountable basket
952-025
Basket
Wall mountable
9000AC9V
Power supply for the ADview Battery
Input: 100-240 V, 50-60 Hz; Output: +9 V; medical grade
9000PCEU
EU power cord
Power or mains lead with Type E and F hybrid, CEE 7/7, two pin plug, 8.2 ft (2.5 m) length
9000PCUK
UK power cord
Power or mains lead with Type G, BS1363, three pin plug, 8.2 ft (2.5 m) length
9000PC
US power cord
Power or mains lead with Type B, NEMA 5-15. three pin plug, 8.2 ft (2.5m) length
9000BPC
BP hose
BP hose with mate for threaded screw type connector, 8 ft (2.4 m) length
9000BAT
Rechargeable battery
6V, sealed lead acid battery
93-9000SM-00
Service Manual
Page 72
62
American Diagnostic Corporation
www.adctoday.com/adview
American Diagnostic Corporation 55 Commerce Drive Hauppauge, NY 11788 USA Tel: 631.273.9600
1.800.232.2670 Fax: 631.273.9659
SunTech Medical, Ltd. Level 19, Two, International Finance Centre 8, Finance Street, Central Hong Kong Tel: +852.2251.1949 Fax: +852.2251.1950
SunTech Medical, Ltd. Service Department Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK Tel: +44. 1865.884.234 Fax: +44. 1865.884.235
IB p/n: 93-9000UM-00
Loading...