Thank you for choosing an ADC®ADSCOPETMStethoscope. Your new ADC®ADSCOPE stethoscope is designed to provide unsurpassed acoustic sensitivity, unrivalled durability, and unparralleled comfort. Every component has been carefully designed to maximize performance.
Device Description and Intended Use
This device is intended for medical diagnostic purposes only. It can be used for listening to heart, lung and other body sounds as well as for normal auscultation. The device is not designed, sold or intended for use except as indicated.
General Warnings
A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately, could lead to patient injury, illness, or death.
CAUTION: NOTE:
Never use stethoscope without eartips firmly locked in place.
When first unpacked, your Sprague tubing may experience some kinks from packaging.
This is normal. To uncurl, hang scope for 24 hours at room temperature.
WARNING:
This product may contain a chemical known to the state of California to cause cancer, birth defects,
or other reproductive harm.
Chestpiece Options
®
The ADC
and 2 diaphragms) to detect a broad frequency range in both pediatric and adult patients. The chestpiece drum accommodates 2 different chestpiece attachments of your choice at one time. Select the type that best suits the intended patient application.
Sprague design utilizes five different interchangeable chestpiece attachments (3 bells
Adult diaphragm assembly ­for filtering out lower frequencies and accent the higher ranges in adults.
Pediatric diaphragm assembly ­for detecting high pitched murmurs in infants and children.
1 1/4” bell - for detecting low and medium pitched sounds and murmurs in adults.
1” bell - for detecting low and medium pitched sounds and murmurs in children.
3/4” bell - for detecting low and medium pitched sounds and murmurs in infants.
TM
Chestpiece attachments can be affixed by threading clockwise until tight. To remove, twist in a counterclockwise direction. (Fig. 1)
Selection of the Chestpiece
On ADC®ADSCOPE
rotates 180° permitting the selection of one side. (Only one side is operable at a time). ADC valve mechanism eliminates virtually all acoustic leakage
Spragues, the entire chestpiece
®
’s patented
(Fig.1)
Adult Diaphragm
Activated
Page 3
from the inoperable side.
To select the side in operation, hold the chestpiece stem in one hand and rotate the chestpiece with the other hand until a click is felt and heard. A light tap on the diaphragm or bell will help determine which side is in operation as well.
Pediatric Diaphragm
Activated
Chestpiece Key
ADC®’s proprietary chestpiece design and slotted key allows you to tighten the pediatric or adult assembly as securely as you like (to reduce risk of loss) without fear of being unable to disassemble the rim in order to replace a worn or broken diaphragm (a problem that often plagues less costly Sprague scopes).
Replacing the Diaphragm
To replace a diaphragm, remove the desired assembly by gripping the assembly firmly and turning counterclockwise.
To loosen the diaphragm rim, insert the key into the two slots located within the threaded portion, located on the underside of the assembly. While holding the rim steady, turn the key counterclockwise to loosen the rim. Remove worn diaphragm and replace with new. Reassemble rim, and tighten by turning key clockwise until tight.
Then reassemble diaphragm rim back onto chestpiece drum by turning clockwise until tight.
Adjusting the Binaurals
To obtain the most comfortable acoustically sealed aural fit, rotate each binaural tube approximately 15° forward, towards the bridge of your nose. Simply twist each tube where it en­ters the tubing.
Correct
Incorrect
Adjusting the Spring Tension in the Binaurals
To reduce the tension, grip the binaurals firmly using both hands with fingers at the center of the “Y” in the tubing, thumbs at each side where the tubing branches out. Flex binaurals gradually until desired tension is obtained. To increase the tension, grip the bin­aurals in the hand and squeeze the binaural tubes together gradu­ally. Caution: Excessive adjustment of the spring tension could weaken the spring.
Thumbs
Here
Page 4
Care and Maintenance
• Avoid extreme heat, cold, solvents, or oils.
• Do NOT leave exposed to direct sunlight for prolonged periods of time.
• Binaurals and tubing can be wiped down with alcohol or mild soapy water.
• Eartips may be unscrewed from binaurals for a thorough cleaning.
• Periodically check that eartips are tightly secured to binaurals.
• Do NOT immerse stethoscope in any liquid or subject to steam sterilization.
• If sterilization is necessary, gas sterilize only.
Replacement Parts List
2
3
8
4
1
6
5
7
9
10
11
18
Ref. Part
No. Item# Name Qty.
1 640-01D Chestpiece Drum Assmbly 1
2 640-02S Retaining Ring, Ped. 1
3 640-03S Diaphragm, Ped. 1
4 640-15 Zinc Disk, Ped. 1
5 640-14 Zinc Disk, Adult 1
6 640-03 Diaphragm, Adult 1
7 640-02 Retaining Ring, Adult 1
8 641-05T Tubing, 22” (spec. color) 2
9 640-16 Tubing Clip 2
10 640-05 Binaurals with 640-09 Eartips 1
11 640-09 Eartips, Black 2
12
13 14
15 16
Ref. Part
No. Item# Name Qty.
12 600-06BK Eartips, Black, Mushroom 2
13 640-10 Eartips, Clear, Soft 2
14 640-11 Bell, 1 1/4” 1
15 640-12 Bell, 1” 1
16 640-13 Bell, 3/4” 1
17 640-18 Accessory Pouch 1
18 640-19 Chestpiece Key 1
3 640-03S Diaphragm, Ped. (spare) 1
6 640-03 Diaphragm, Adult (spare) 1
17
Page 5
LIMITED WARRANTY
American Diagnostic Corporation (ADC®) warrants its products against defects in materials and workmanship under normal use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date of delivery.
2. Your ADSCOPE™ Sprague stethoscope is warranted for five years from date of purchase (all parts).
What is Covered: Replacement of parts, and labor. What is Not Covered: Transportation charges to and from ADC
®
. Damages caused by abuse, misuse, accident, or negligence. Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, or consequential damages, so this limitation may not apply to you. To Obtain Warranty Service: Send item(s) postage paid to ADC
®
, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem. Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the original selling price (except where prohibited by law). This warranty gives you specific legal rights and you may have other rights which vary from state to state.
To Register Your Product, visit us at
www.adctoday.com
and follow the links
FOR QUESTIONS, COMMENTS, OR SUGGESTIONS