PCnet™-ISA II Jumperless, Full Duplex Single-Chip
Ethernet Controller for ISA
DISTINCTIVE CHARACTERISTICS
■
Single-chip Ethernet controller for the Industry
Standard Architecture (ISA) and Extended
Industry Standard Architecture (EISA) buses
■
Supports IEEE 802.3/ANSI 8802-3 and Ethernet
standards
■
Supports full duplex operation on the
10BASE-T, AUI, and GPSI ports
■
Direct interface to the ISA or EISA bus
■
Pin compatible to Am79C961 PCnet-ISA+
Jumperless Single-Chip Ethernet Controller
■
Software compatible with AMD’s Am7990
LANCE register and descriptor architecture
■
Low power, CMOS design with sleep mode
allows reduced power consumption for critical
battery powered applications
■
Individual 136-byte transmit and 128-byte
receive FIFOs provide packet buffering for
increased system latency, and support the
following features:
— Automatic retransmission with no FIFO
reload
— Automatic receive stripping and transmit
padding (individually programmable)
— Automatic runt packet rejection
— Automatic deletion of received collision
frames
■
Dynamic transmit FCS generation
programmable on a frame-by-frame basis
■
Single +5 V power supply
■
Internal/external loopback capabilities
■
Supports 8K, 16K, 32K, and 64K Boot PROMs or
Flash for diskless node applications
■
Supports Microsoft’s Plug and Play System
configuration for jumperless designs
■
Supports staggered AT bus drive for reduced
noise and ground bounce
■
Supports 8 interrupts on chip
■
Look Ahead Packet Processing (LAPP)
allows protocol analysis to begin before
end of receive frame
■
Supports 4 DMA channels on chip
■
Supports 16 I/O locations
■
Supports 16 boot PROM locations
■
Provides integrated Attachment Unit Interface
(AUI) and 10B ASE-T transceiver with 2 modes of
port selection:
— Automatic selection of AUI or 10BASE-T
— Software selection of AUI or 10BASE-T
■
Automatic Twisted Pair receive polarity
detection and automatic correction of the
receive polarity
■
Supports bus-master, programmed I/O, and
shared-memory architectures to fit in any PC
application
■
Supports edge and level-sensitive interrupts
■
DMA Buffer Management Unit for reduced CPU
intervention which allows higher throughput by
by-passing the platform DMA
■
JTAG Boundary Scan (IEEE 1149.1) test access
port interface for board level production test
■
Integrated Manchester Encoder/Decoder
■
Supports the following types of network
interfaces:
— AUI to external 10BASE2, 10BASE5,
10BASE-T or 10BASE-F MAU
— Internal 10BASE-T transceiver with Smart
Squelch to Twisted Pair medium
■
Supports LANCE General Purpose Serial
Interface (GPSI)
■
132-pin PQFP package
This document contains information on a product under development at Advanced Micro Devices. The information
is intended to help you evaluate this product. AMD reserves the right to change or discontinue work on this proposed
product without notice.
Publication# 19364 Rev: A Amendment/+3
Issue Date: September 1996
PRELIMINARY
GENERAL DESCRIPTION
The PCnet-ISA II controller, a single-chip Ethernet controller, is a highly integrated system solution for the
PC-AT Industry Standard Architecture (ISA) architecture. It is designed to provide flexibility and compatibility with any existing PC application. This highly
integrated 132-pin VLSI device is specifically designed
to reduce parts count and cost, and addresses applications where higher system throughput is desired. The
PCnet-ISA II controller is fabricated with AMD’s
advanced low-power CMOS process to provide low
standby current for power sensitive applications.
The PCnet-ISA II controller can be configured into one
of three different architecture modes to suit a particular
PC application. In the Bus Master mode, all transfers
are performed using the integrated DMA controller.
This configuration enhances system performance by
allowing the PCnet-ISA II controller to bypass the platform DMA controller and directly address the full 24-bit
memory space. The implementation of Bus Master
mode allows minimum parts count for the majority of
PC applications. The PCnet-ISA II can also be configured as a Bus Slave with either a Shared Memory or
Programmed I/O architecture for compatibility with
low-end machines, such as PC/XTs that do not support
Bus Masters, and high-end machines that require local
packet buffering for increased system latency.
The PCnet-ISA II controller is designed to directly interface with the ISA or EISA system bus. It contains an
ISA Plug and Play bus interf ace unit, DMA Buffer Management Unit, 802.3 Media Access Control function,
individual 136-byte transmit and 128-byte receive
FIFOs, IEEE 802.3 defined Attachment Unit Interface
(AUI), and a Twisted Pair Transceiver Media Attachment Unit. Full duplex network operation can be
enabled on any of the device’s network ports. The
PCnet-ISA II controller is also register compatible with
the LANCE (Am7990) Ethernet controller and
PCnet-ISA. The DMA Buffer Management Unit supports the LANCE descriptor software model. External
remote boot and Ethernet physical address PROMs
and Electrically Erasable Proms are also supported.
This advanced Ethernet controller has the built-in
capability of automatically selecting either the AUI port
or the Twisted Pair transceiver. Only one interface is
active at any one time. The individual 136-byte transmit
and 128-byte receive FIFOs optimize system overhead, providing sufficient latency during packet transmission and reception, and minimizing intervention
during normal network error recovery. The integrated
Manchester encoder/decoder eliminates the need for
an external Serial Interface Adapter (SIA) in the node
system. If support for an external encoding/decoding
scheme is desired, the embedded General Purpose
Serial Interface (GPSI) allows direct access to/from the
MAC. In addition, the device provides programmable
on-chip LED drivers for transmit, receive, collision,
receive polarity, link integrity and activity, or jabber
status. The PCnet-ISA II controller also provides an
External Address Detection InterfaceTM (EADITM) to
allow external hardware address filtering in internetworking applications.
RELATED PRODUCTS
Part No.Description
Am79C98Twisted Pair Ethernet Transceiver (TPEX)
Am79C100Twisted Pair Ethernet Transceiver Plus (TPEX+)
Am7996IEEE 802.3/Ethernet/Cheapernet Transceiver
Am79C981Integrated Multiport Repeater Plus (IMR+)
Am79C987Hardware Implemented Management Information Base (HIMIB)
Am79C940Media Access Controller for Ethernet (MACE)
Am79C90CMOS Local Area Network Controller for Ethernet (C-LANCE)
Am79C960PCnet-ISA Single-Chip Ethernet Controller (for ISA bus)
Am79C961PCnet-ISA Jumperless Single-Chip Ethernet Controller (for ISA bus)
Am79C965PCnet-32 Single-Chip 32-Bit Ethernet Controller (for 386, 486, VL local buses)
Am79C970PCnet-PCI Single-Chip Ethernet Controller (for PCI bus)
Am79C974PCnet-SCSI Combination Single-Chip Ethernet and SCSI Controller (for PCI bus)
2Am79C961A
PRELIMINARY
ORDERING INFORMATION
Standard Products
AMD standard products are available in se ver al packages and operating r anges. The order number (Valid Combination) is f ormed
by a combination of:
AM79C961AKC\W
ALTERNATE PACKAGING OPTION
\W=Trimmed and Formed (PQB132)
OPTIONAL PROCESSING
Blank=Standard Processing
TEMPERATURE RANGE
C=Commercial (0
P ACKA GE TYPE (per Prod. Nomenclature/16-038)
K=Molded Carrier Ring Plastic Quad Flat Pack
(PQB132)
SPEED
Not Applicable
°C to +70°C)
DEVICE NUMBER/DESCRIPTION
Am79C961A
PCnet-ISA II Jumperless Single-Chip Ethernet Controller for ISA
Valid Combinations
AM79C961AKC, KC\W
Valid Combinations list configurations planned to be supported in volume for this device. Consult the local AMD sales
office to confirm availability of specific valid combinations and
to check on newly released combinations.
Address Enable
Bus Address Latch Enable
DMA Acknowledge
DMA Request
I/O Channel Ready
I/O Chip Select 16
I/O Read Select
I/O Write Select
Interrupt Request
Unlatched Address Bus
Master Transfer in Progress
Memory Read Select
Memory Write Select
Memory Refresh Active
System Reset
System Address Bus
System Byte High Enable
System Data Bus
IRQ15 or Address PROM Chip Select
Boot PROM Chip Select
Disable Transceiver
LED0/LNKST
LED1/SFBD/RCV A CT
LED2/SRD/RXDATPOL
LED3/SRDCLK/XMTACT
PROM Data Bus
Sleep Mode
Crystal Input
Crystal Output
Read access from EEPROM in process
Serial Shift Clock
Serial Shift Data In
Serial Shift Data Out
EEPROM Chip Select
I/O
I/O
O
O
I/O
O
O
O
I/O
I/O
I/O
O
O
I/O
O
O
O
O
I/O
O
I/O
I/O
I/O
O
I
I
I
TS3
OD3
OD3
I
I
TS3/OD3
TS3
OD3
TS3
TS3
I
I
TS3
TS3
TS3
TS1
TS1
TS1
TS2
TS2
TS2
TS2
TS1
I
I
14Am79C961A
PRELIMINARY
PIN DESIGNATIONS: BUS MASTER MODE (continued)
Listed by Group
These pins are part of the bus master mode. In order to
understand the pin descriptions, definition of some
terms from a draft of IEEE P996 are included.
IEEE P996 Terminology
Alternate Master: Any device that can take control of
the bus through assertion of the MASTER signal. It has
the ability to generate addresses and bus control signals in order to perform bus operations. All Alter nate
Masters must be 16 bit devices and drive SBHE.
Bus Ownership: The Current Master possesses bus
ownership and can assert any bus control, address and
data lines.
Current Master: The Permanent Master, Temporary
Master or Alternate Master which currently has ownership of the bus.
Permanent Master: Each P996 bus will hav e a de vice
known as the Permanent Master that provides certain
signals and bus control functions as described in Section 3.5 (of the IEEE P996 spec.), “P ermanent Master”.
The Permanent Master function can reside on a Bus
Adapter or on the backplane itself.
Temporary Master: A de vice that is capable of generating a DMA request to obtain control of the bus and
directly asserting only the memory and I/O strobes
during bus transfer. Addresses are generated by the
DMA device on the Permanent Master.
ISA Interface
AEN
Address Enable
This signal must be driven LOW when the bus perf orms
an I/O access to the device.
Input
BALE
Used to latch the LA20–23 address lines.
DACK 3, 5-7
DMA Acknowledge
Asserted LOW when the Permanent Master acknowledges a DMA request. When DACK is asserted the
PCnet-ISA II controller becomes the Current Master by
asserting the MASTER signal.
Input
DRQ 3, 5-7
DMA Request
When the PCnet-ISA II controller needs to perform a
DMA transfer, it asserts DRQ. The Permanent Master
acknowledges DRQ with the assertion of DACK. When
the PCnet-ISA II does not need the bus it desserts
DRQ. The PCnet-ISA II provides for fair bus bandwidth
sharing between two bus mastering devices on the ISA
bus through an adaptive delay which is inserted
Input/Output
between back-to-back DMA requests. See the
Back-to-Back DMA Requests section for details.
Because of the operation of the Plug and Play registers, the DMA Channels on the PCnet-ISA II must be
attached to the specific DRQ and DACK signals on the
PC/AT bus as indicated by the pin names.
IOCHRDY
I/O Channel Ready
When the PCnet-ISA II controller is being accessed,
IOCHRDY HIGH indicates that valid data exists on the
data bus for reads and that data has been latched for
writes. When the PCnet-ISA II controller is the Current
Master on the ISA bus, it extends the b us cycle as long
as IOCHRDY is LOW.
Input/Output
IOCS16
I/O Chip Select 16
When an I/O read or write operation is performed, the
PCnet-ISA II controller will drive the IOCS16 pin LOW
to indicate that the chip supports a 16-bit operation at
this address. (If the motherboard does not receive this
signal, then the motherboard will convert a 16-bit
access to two 8-bit accesses).
The PCnet-ISA II controller follows the IEEE P996 specification that recommends this function be implemented
as a pure decode of SA0-9 and AEN, with no dependency on IOR, or IOW ; howe ver, some PC/A T clone systems are not compatible with this approach. For this
reason, the PCnet-ISA II controller is recommended to
be configured to run 8-bit I/O on all machines. Since
data is moved by memory cycles there is virtually no performance loss incurred by running 8-bit I/O and compatibility problems are virtually eliminated. The PCnet-ISA II
controller can be configured to run 8-bit-only I/O by
clearing Bit 0 in Plug and Play register F0.
Output
IOR
I/O Read
IOR is driven LOW by the host to indicate that an Input/
Output Read operation is taking place. IOR is only v alid
if the AEN signal is LOW and the external address
matches the PCnet-ISA II controller’s predefined I/O
address location. If valid, IOR indicates that a slave
read operation is to be performed.
Input
IOW
I/O Write
IOW is driven LOW b y the host to indicate that an Input/
Output Write operation is taking place. IO W is only valid
if AEN signal is LOW and the external address matches
the PCnet-ISA II controller’s predefined I/O address
location. If valid, IOW indicates that a slave write operation is to be performed.
Input
16Am79C961A
PRELIMINARY
IRQ 3, 4, 5, 9, 10, 11, 12, 15
Interrupt Request
An attention signal which indicates that one or more of
the following status flags is set: BABL, MISS, MERR,
RINT, IDON, RCVCCO, JAB, MPCO, or TXDATSTRT.
All status flags have a mask bit which allows for suppression of IRQ assertion. These flags have the
following meaning:
Because of the operation of the Plug and Play registers, the interrupts on the PCnet-ISA II must be
attached to specific IRQ signals on the PC/AT bus.
Output
LA17-23
Unlatched Address Bus
The unlatched address bus is driven by the PCnet-ISA
II controller during bus master cycle.
The functions of these unlatched address pins will
change when GPSI mode is invoked. The following
table shows the pin configuration in GPSI mode. Please
refer to the section on General Purpose Serial Interface
for detailed information on accessing this mode.
This signal indicates that the PCnet-ISA II controller
has become the Current Master of the ISA bus. After
the PCnet-ISA II controller has received a DMA
Acknowledge (DACK) in response to a DMA Request
Input/Output
(DRQ), the Ethernet controller asserts the MASTER
signal to indicate to the Permanent Master that the
PCnet-ISA II controller is becoming the Current Master.
MEMR
Memory Read
MEMR goes LOW to perform a memory read operation.
Input/Output
MEMW
Memory Write
MEMW goes LOW to perform a memory write
operation.
Input/Output
REF
Memory Refresh
When REF is asserted, a memory refresh is active. The
PCnet-ISA II controller uses this signal to mask inadvertent DMA Acknowledge assertion during memory
refresh periods. If DACK is asserted when REF is
active, D ACK assertion is ignored. REF is monitored to
eliminate a bus arbitration problem observed on some
ISA platforms.
Input
RESET
Reset
When RESET is asserted HIGH the PCnet-ISA II controller performs an internal system reset. RESET must
be held for a minimum of 10 XTAL1 periods before
being deasserted. While in a reset state , the PCnet-ISA
II controller will tristate or deassert all outputs to predefined reset levels. The PCnet-ISA II controller resets
itself upon power-up.
Input
SA0-19
System Address Bus
This bus contains address information, which is stable
during a bus operation, regardless of the source.
SA17-19 contain the same values as the unlatched
address LA17-19. When the PCnet-ISA II controller is
the Current Master, SA0-19 will be driven actively.
When the PCnet-ISA II controller is not the Current
Master, the SA0-19 lines are continuously monitored to
determine if an address match exists for I/O slave
transfers or Boot PROM accesses.
Input/Output
SBHE
System Byte High Enable
This signal indicates the high byte of the system data
bus is to be used. SBHE is driven by the PCnet-ISA II
controller when performing bus mastering operations.
Input/Output
SD0-15
System Data Bus
These pins are used to transfer data to and from the
PCnet-ISA II controller to system resources via the ISA
data bus. SD0-15 is driven by the PCnet-ISA II control-
Input/Output
Am79C961A17
PRELIMINARY
ler when performing bus master writes and slave read
operations. Likewise, the data on SD0-15 is latched by
the PCnet-ISA II controller when performing bus
master reads and slave write operations.
Board Interface
IRQ12/FlashWE
Flash Write Enable
Optional interface to the Flash memory boot PROM
Write Enable.
Output
IRQ15/APCS
Address PROM Chip Select
When programmed as APCS in Plug and Play Register
F0, this signal is asserted when the external Address
PROM is read. When an I/O read operation is
performed on the first 16 bytes in the PCnet-ISA II controller’s I/O space, APCS is asserted. The outputs of
the external Address PROM drive the PROM Data Bus.
The PCnet-ISA II controller buffers the contents of the
PROM data bus and drives them on the lower eight bits
of the System Data Bus.
When programmed to IRQ15 (default), this pin has the
same function as IRQ 3, 4, 5, 9, 10, 11, or 12.
Output
BPCS
Boot PROM Chip Select
This signal is asserted when the Boot PROM is read. If
SA0-19 lines match a predefined address block and
MEMR is active and REF inactive , the BPCS signal will
be asserted. The outputs of the external Boot PROM
drive the PROM Data Bus. The PCnet-ISA II controller
buffers the contents of the PROM data bus and drives
them on the lower eight bits of the System Data Bus.
Output
DXCVR/EAR
Disable T ransceiver/
External Address Reject
This pin can be used to disable external transceiver
circuitry attached to the AUI interface when the internal
10BASE-T port is active. The polarity of this pin is set
by the DXCVRP bit (PnP register 0xF0, bit 5). When
DXCVRP is cleared (default), the DXCVR pin is driven
HIGH when the Twisted Pair port is active or SLEEP
mode has been entered and driven LOW when the A UI
port is active. When DXCVRP is set, the DXCVR pin is
driven LOW when the Twisted Pair por t is active or
SLEEP mode has been entered and driven HIGH when
the AUI port is active.
Input/Output
If EADI mode is selected, this pin becomes the EAR
input.
The incoming frame will be checked against the internally active address detection mechanisms and the
result of this check will be OR’d with the value on the
EAR pin. The EAR pin is defined as REJECT. (See the
EADI section for details regarding the function and
timing of this signal).
LEDO-3
LED Drivers
These pins sink 12 mA each for driving LEDs. Their
meaning is software configurable (see section
Bus Configuration Registers
When EADI mode is selected, the pins named LED1,
LED2, and LED3 change in function while LED0
continues to indicate 10BASE-T Link Status.
LEDEADI Function
1SF/BD
2SRD
3SRDCLK
Output
The ISA
) and they are active LO W.
PRDB3-7
Private Data Bus
This is the data bus for the Boot PROM and the
Address PROM.
Input/Output
PRDB2/EEDO
Private data bus bit 2/Data Out
A multifunction pin which serves as PRDB2 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become DATA OUT from the EEPROM.
Input/Output
PRDB1/EEDI
Private data bus bit 1/Data In
A multifunction pin which serves as PRDB1 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become DATA In to the EEPROM.
Input/Output
PRDB0/EESK
Private data bus bit 0/
Serial Clock
A multifunction pin which serves as PRDB0 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become Serial Clock to the EEPROM.
Input/Output
18Am79C961A
PRELIMINARY
SHFBUSY
Shift Busy
This pin indicates that a read from the exter nal
EEPROM is in progress. It is active only when data is
being shifted out of the EEPROM due to a hardware
RESET or assertion of the EE_LOAD bit (ISACSR3, bit
14). If this pin is left unconnected or pulled low with a
pull-down resistor, an EEPROM checksum error is
forced. Normally, this pin should be connected to V
through a 10K Ω pull-up resistor.
Input/Output
CC
EECS
EEPROM CHIP SELECT
This signal is asserted when read or write accesses
are being performed to the EEPROM. It is controlled by
ISACSR3. It is driven at Reset during EEPROM Read.
Output
SLEEP
Sleep
When SLEEP pin is asserted (active LOW), the
PCnet-ISA II controller performs an internal system
reset and proceeds into a power savings mode. All
Input
outputs will be placed in their normal reset condition.
All PCnet-ISA II controller inputs will be ignored except
for the SLEEP
in the device waking up. The system must delay the
starting of the network controller by 0.5 seconds to
allow internal analog circuits to stabilize.
pin itself. Deassertion of SLEEP results
XTAL1
Crystal Connection
The internal clock generator uses a 20 MHz crystal that
is attached to pins XTAL1 and XTAL2. Alternatively, an
external 20 MHz CMOS-compatible clock signal can be
used to drive this pin. Refer to the section on Exter nal
Crystal Characteristics for more details.
Input
XTAL2
Crystal Connection
The internal clock generator uses a 20 MHz crystal that
is attached to pins XTAL1 and XTAL2. If an external
clock is used, this pin should be left unconnected.
Output
Am79C961A19
PRELIMINARY
Power up
RESET_DRV
Set CSN = 0
StateActive Commands
StateActive Commands
Reset
Isolation
Wait for Key
Set RD_DATA Port
Serial Isolation
Wake[CSN]
Wait for Key
StateActive Commands
Sleep
Lose serial location OR
(WAKE <> CSN)
no active commands
Initiation Key
Reset
Wait for Key
Wake[CSN]
Set CSN
WAKE <> CSN
Config
StateActive Commands
Reset
Wait for Key
Wake[CSN]
Resource Data
Status
Logical Device
I/O Range Check
Activate
Configuration Registers
Notes:
1. CSN = Card Select Number.
2. RESET_DRV causes a state transition from the current state to Wait for Key and sets all CSNs to
zero. All logical devices are set to their power-up configuration values.
3. The Wait for Key command causes a state transition from the current state to Wait for Key.
BP
DXCVR/EAR
LED0
LED1
LED2
LED3
PRAB[0–15]PRivate Address BusI/OTS3
PRDB[3–7]PRivate Data BusI/OTS1
SLEEP
SMA
SMAM
OEStatic RAM Output EnableOTS3
SR
WEStatic RAM Write EnableOTS1
SR
XTAL1Crystal Oscillator InputI
XTAL2Crystal Oscillator OUTPUTO
SHFBUSYRead access from EEPROM in processO
PRDB(0)/EESKSerial Shift ClockI/O
PRDB(1)/EEDISerial Shift Data InI/O
PRDB(2)/EEDOSerial Shift Data OutI/O
EECSEEPROM Chip Select O
This signal must be driven LOW when the bus perf orms
an I/O access to the device.
Input
IOCHRDY
I/O Channel Ready
When the PCnet-ISA II controller is being accessed, a
HIGH on IOCHRDY indicates that valid data exists on
the data bus for reads and that data has been latched
for writes.
Output
IOCS16
I/O Chip Select 16
When an I/O read or write operation is performed, the
PCnet-ISA II controller will drive this pin LOW to indicate that the chip supports a 16-bit operation at this
address. (If the motherboard does not receive this
signal, then the motherboard will convert a 16-bit
access to two 8-bit accesses).
The PCnet-ISA II controller follows the IEEE P996 specification that recommends this function be implemented
as a pure decode of SA0-9 and AEN, with no dependency on IOR, or IOW; however, some PC/AT clone
systems are not compatible with this approach. For this
reason, the PCnet-ISA II controller is recommended to
be configured to run 8-bit I/O on all machines. Since
data is moved by memory cycles there is vir tually no
performance loss incurred by running 8-bit I/O and
compatibility problems are virtually eliminated. The
PCnet-ISA II controller can be configured to run
8-bit-only I/O by clearing Bit 0 in Plug and Play Register
F0.
Input/Output
IOR
I/O Read
To perform an Input/Output Read operation on the
device IOR must be asserted. IOR is only valid if the
AEN signal is LOW and the external address matches
the PCnet-ISA II controller’s predefined I/O address
location. If v alid, IOR indicates that a sla v e read oper ation is to be performed.
Input
IOW
I/O Write
To perform an Input/Output write operation on the
device IOW m ust be asserted. IOW is only v alid if AEN
signal is LOW and the external address matches the
PCnet-ISA II controller’s predefined I/O address location. If valid, IOW indicates that a slave write operation
is to be performed.
Input
IRQ3, 4, 5, 9, 10, 11, 12, 15
Interrupt Request
An attention signal which indicates that one or more of
the following status flags is set: BABL, MISS, MERR,
RINT , IDON or TXSTR T. All status flags hav e a mask bit
which allows for suppression of IRQ assertion. These
flags have the following meaning:
MEMW goes LOW to perform a memory write operation.
Input
REF
Memory Refresh
When REF is asserted, a memory refresh cycle is in
progress. During a refresh cycle, MEMR asser tion
is ignored.
Input
RESET
Reset
When RESET is asserted HIGH, the PCnet-ISA II
controller performs an internal system reset. RESET
must be held for a minimum of 10 XTAL1 periods before
being deasserted. While in a reset state , the PCnet-ISA
II controller will tristate or deassert all outputs to
predefined reset levels. The PCnet-ISA II controller
resets itself upon power-up.
Input
SA0-15
System Address Bus
This bus carries the address inputs from the system
address bus. Address data is stable during command
active cycle.
Input
Am79C961A27
PRELIMINARY
SBHE
System Bus High Enable
This signal indicates the HIGH byte of the system data
bus is to be used. There is a weak pull-up resistor on
this pin. If the PCnet-ISA II controller is installed in an
8-bit only system like the PC/XT, SBHE will always be
HIGH and the PCnet-ISA II controller will perform only
8-bit operations. There must be at least one LO W going
edge on this signal before the PCnet-ISA II controller
will perform 16-bit operations.
Input
SD0-15
System Data Bus
This bus is used to transfer data to and from the
PCnet-ISA II controller to system resources via the ISA
data bus. SD0-15 is driven by the PCnet-ISA II
controller when performing slave read operations.
Likewise, the data on SD0-15 is latched by the
PCnet-ISA II controller when performing slave write
operations.
Input/Output
Board Interface
APCS/IRQ15
Address PROM Chip Select
This signal is asserted when the external Address
PROM is read. When an I/O read operation is performed on the first 16 bytes in the PCnet-ISA II
controller’s I/O space, APCS is asserted. The outputs
of the external Address PROM drive the PROM Data
Bus. The PCnet-ISA II controller b uff ers the contents of
the PROM data bus and drives them on the lower eight
bits of the System Data Bus. IOCS16 is not asserted
during this cycle.
Output
BPAM
Boot PROM Address Match
This pin indicates a Boot PROM access cycle. If no
Boot PROM is installed, this pin has a default value of
HIGH and thus may be left connected to VDD.
Input
BPCS
Boot PROM Chip Select
This signal is asserted when the Boot PROM is read. If
BPAM is active and MEMR is active, the BPCS signal
will be asserted. The outputs of the external Boot
PROM drive the PROM Data Bus. The PCnet-ISA II
controller buffers the contents of the PROM data bus
and drives them on the System Data Bus. IOCS16 is
not asserted during this cycle. If 16-bit cycles are
performed, it is the responsibility of external logic to
assert MEMCS16 signal.
Output
DXCVR/EAR
Disable Transceiver/
External Address Reject
This pin disables the transceiver. The DXCVR output is
configured in the initialization sequence. A high level
indicates the Twisted Pair Interface is active and the
AUI is inactive, or SLEEP mode has been entered. A
low level indicates the A UI is activ e and the T wisted P air
interface is inactive.
If EADI mode is selected, this pin becomes the EAR
input.
The incoming frame will be checked against the internally active address detection mechanisms and the
result of this check will be OR’d with the value on the
pin. The EAR pin is defined as REJECT. (See the
EAR
EADI section for details regarding the function and timing of this signal).
Input/Output
LED0-3
LED Drivers
These pins sink 12 mA each for driving LEDs. Their
meaning is software configurable (see section
Bus Configuration Registers
When EADI mode is selected, the pins named LED1,
LED2, and LED3 change in function while LED0
continues to indicate 10BASE-T Link Status. The
DXCVR input becomes the EAR input.
LEDEADI Function
1SF/BD
2SRD
3SRDCLK
Output
The ISA
) and they are active LO W.
PRAB0-15
Private Address Bus
The Private Address Bus is the address bus used to
drive the Address PROM, Remote Boot PROM, and
SRAM. PRAB10-15 are required to be buffered by a
Bus Buffer with ABOE as its control and SA10-15 as its
inputs.
Input/Output
PRDB3-7
Private Data Bus
This is the data bus for the static RAM, the Boot PROM,
and the Address PROM.
Input/Output
PRDB2/EEDO
Private Data Bus Bit 2/Data Out
A multifunction pin which serves as PRDB2 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become DATA OUT from the EEPROM.
Input/Output
28Am79C961A
PRELIMINARY
PRDB1/EEDI
Private Data Bus Bit 1/Data In
A multifunction pin which serves as PRDB1 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become DATA In to the EEPROM.
Input/Output
PRDB0/EESK
Private Data Bus Bit 0/
Serial Clock
A multifunction pin which serves as PRDB0 of the
private data bus and, when ISACSR3 bit 4 is set,
changes to become Serial Clock to the EEPROM.
Input/Output
SHFBUSY
Shift Busy
This pin indicates that a read from the exter nal
EEPROM is in progress. It is active only when data is
being shifted out of the EEPROM due to a hardware
RESET or assertion of the EE_LOAD bit (ISACSR3, bit
14). If this pin is left unconnected or pulled low with a
pull-down resistor, an EEPROM checksum error is
forced. Normally, this pin should be connected to V
through a 10K Ω pull-up resistor.
Input/Output
CC
EECS
EEPROM CHIP SELECT
This signal is asserted when read or write accesses
are being performed to the EEPROM. It is controlled by
ISACSR3. It is driven at Reset during EEPROM Read.
Output
SLEEP
Sleep
When SLEEP input is asserted (active LOW), the
PCnet-ISA II controller performs an internal system
reset and proceeds into a power savings mode. All outputs will be placed in their normal reset condition. All
PCnet-ISA II controller inputs will be ignored except for
the SLEEP pin itself. Deassertion of SLEEP results in
the device waking up. The system must delay the
starting of the network controller by 0.5 seconds to
allow internal analog circuits to stabilize.
Input
SMA
Slave Mode Architecture
This pin must be permanently pulled LOW for operation
in the Bus Slave mode. It is sampled after the hardware
RESET sequence. In the Bus Slave mode, the
PCnet-ISA II can be programmed for Shared Memory
Input
access or Programmed I/O access through the
PIOSEL bit (ISACSR2, bit 13).
SMAM
Shared Memory
Address Match
When the Shared Memory architecture is selected
(ISACSR2, bit 13), this pin is an input that indicates an
access to shared memory when asserted. The type of
access is decided by MEMR or MEMW.
When the Programmed I/O architecture is selected,
this pin should be permanently tied HIGH.
Input
SROE
Static RAM Output Enable
This pin directly controls the external SRAM’s OE pin.
Output
SRCS/IRQ12
Static RAM Chip Select
This pin directly controls the external SRAM’s chip
select (CS) pin when the Flash boot ROM option is
selected.
When Flash boot ROM option is not selected, this pin
becomes IRQ12.
Output
SRWE/WE
Static RAM Write Enable/
Write Enable
This pin (SRWE) directly controls the external SRAM’s
WE pin when a Flash memory device is not
implemented.
When a Flash memory device is implemented, this pin
becomes a global write enable (WE) pin.
Output
XTAL1
Crystal Connection
The internal clock generator uses a 20 MHz crystal that
is attached to pins XTAL1 and XTAL2. Alternatively, an
external 20 MHz CMOS-compatible clock signal can be
used to drive this pin. Refer to the section on Exter nal
Crystal Characteristics for more details.
Input
XTAL2
Crystal Connection
The internal clock generator uses a 20 MHz crystal that
is attached to pins XTAL1 and XTAL2. If an external
clock is used, this pin should be left unconnected.
Output
Am79C961A29
PRELIMINARY
PIN DESCRIPTION:
NETWORK INTERFACES
AUI
CI+, CI–
Control Input
This is a differential input pair used to detect Collision
(Signal Quality Error Signal).
Input
DI+, DI–
Data In
This is a differential receive data input pair to the
PCnet-ISA II controller.
Input
DO+, DO–
Data Out
This is a differential transmit data output pair from the
PCnet-ISA II controller.
Output
Twisted Pair Interface
RXD+, RXD–
Receive Data
This is the 10BASE-T port differential receive input
pair.
Input
TXD+, TXD–
Transmit Data
These are the 10BASE-T port differential transmit
drivers.
Output
TXP+, TXP–
Transmit Predistortion Control
These are 10BASE-T transmit waveform pre-distortion
control differential outputs.
Output
PIN DESCRIPTION:
IEEE 1149.1 (JTAG) TEST ACCESS PORT
TCK
Test Clock
This is the clock input for the boundary scan test mode
operation. TCK can operate up to 10 MHz. TCK does
not have an internal pull-up resistor and must be connected to a valid TTL le v el of high or lo w. TCK m ust not
be left unconnected.
Input
TDI
Test Data Input
This is the test data input path to the PCnet-ISA II controller. If left unconnected, this pin has a default value
of HIGH.
Input
TDO
Test Data Output
This is the test data output path from the PCnet-ISA II
controller. TDO is tri-stated when JTAG port is inactive.
Output
TMS
Test Mode Select
This is a serial input bit stream used to define the specific boundary scan test to be executed. If left unconnected, this pin has a default value of HIGH.
Input
PIN DESCRIPTION:
POWER SUPPLIES
All power pins with a “D” prefix are digital pins connected to the digital circuitry and digital I/O buffers. All
power pins with an “A” prefix are analog power pins
connected to the analog circuitry. Not all analog pins
are quiet and special precaution must be taken when
doing board layout. Some analog pins are more noisy
than others and must be separated from the other
analog pins.
AVDD1–4
Analog Power (4 Pins)
Supplies power to analog portions of the PCnet-ISA II
controller. Special attention should be paid to the
printed circuit board layout to av oid excessive noise on
these lines.
Power
AVSS1–2
Analog Ground (2 Pins)
Supplies ground reference to analog portions of
PCnet-ISA II controller. Special attention should be
paid to the printed circuit board layout to avoid excessive noise on these lines.
Power
DVDD1–7
Digital Power (7 Pins)
Supplies power to digital portions of PCnet-ISA II controller. F our pins are used by Input/Output b uffer drivers
and two are used by the internal digital circuitry.
Power
DVSS1–13
Digital Ground (13 Pins)
Supplies ground reference to digital portions of
PCnet-ISA II controller. Ten pins are used by Input/Output buffer drivers and two are used by the internal
digital circuitry.
The PCnet-ISA II controller is a highly integrated system
solution for the PC-AT ISA architecture. It provides a Full
Duplex Ethernet controller, AUI port, and 10BASE-T
transceiver . The PCnet-ISA II controller can be directly interfaced to an ISA system bus. The PCnet-ISA II controller contains an ISA bus interface unit, DMA Buffer
Management Unit, 802.3 Media Access Control function,
separate 136-byte transmit and 128-byte receive FIFOs,
IEEE defined Attachment Unit Interface (AUI), and
Twisted-Pair Transceiver Media Attachment Unit. In addition, a Sleep function has been incorporated which provides low standby current for po wer sensitive applications.
The PCnet-ISA II controller is register compatible with
the LANCE (Am7990) Ethernet controller and
PCnet-ISA (Am79C960). The DMA Buffer Management
Unit supports the LANCE descriptor software model
and the PCnet-ISA II controller is software compatible
with the Novell NE2100 and NE1500T add-in cards.
External remote boot PROMs and Ethernet physical
address PROMs are supported. The location of the I/O
registers, Ethernet address PROM, and the boot PROM
are determined by the programming of the registers internal to PCnet-ISA II. These registers are loaded at
RESET from the EEPROM, if an EEPROM is utilized.
Normally , the Ethernet physical address will be stored in
the EEPROM with the other configuration data. This
reduces the parts count, board space requirements,
and power consumption. The option to use a standard
parallel 8 bit PROM is provided to manufactures who
are concerned about the non-volatile nature of
EEPROMs.
The PCnet-ISA II controller’s bus master architecture
brings to system manufacturers (adapter card and
motherboard makers alike) something they have not
been able to enjoy with other architectures—a low-cost
system solution that provides the lowest parts count
and highest performance. As a bus-mastering device,
costly and power-hungry external SRAMs are not
needed for packet buffering. This results in lower system cost due to fewer components , less real-estate and
less power. The PCnet-ISA II controller’s advanced bus
mastering architecture also provides high data throughput and low CPU utilization for e ven better perf ormance.
T o off er greater fle xibility , the PCnet-ISA II controller has
a Bus Slave mode to meet varying application needs.
The bus slave mode utilizes a local SRAM memory to
store the descriptors and buffers that are located in system memory when in Bus Master mode. The SRAM can
be slave accessed on the ISA bus through memory
cycles in Shared Memory mode or I/O cycles in Programmed I/O mode. The Shared Memory and Programmed I/O architectures offer maximum compatibility
with low-end machines, such as PC/XTs that do not
support bus mastering, and very high end machines
which require local packet buffering for increased
system latency.
The network interface provides an Attachment Unit
Interface and Twisted-Pair Transceiver functions. Only
one interface is active at any particular time. The AUI
allows for connection via isolation transformer to
10BASE5 and 10BASE2, thick and thin based coaxial
cables. The Twisted-Pair Transceiver interface allows
for connection of unshielded twisted-pair cables as
specified by the Section 14 supplement to IEEE 802.3
Standard (Type 10BASE-T).
Important Note About The EEPROM
Byte Map
The user is cautioned that while the Am79C961A
(PCnet-ISA II) and its associated EEPROM are pin compatible to their predecessors the Am79C961 (PCnet-ISA+)
and its associated EEPROM, the byte map structure in
each of the EEPROMs are different from each other.
The EEPROM byte map structure used for the
Am79C961A PCnet-ISA II has the addition of “MISC Config 2, ISACSR9" at word location 10Hex. The EEPROM
byte map structure used for the Am79C961 PCnet-ISA+
does not have this.
Therefore, should the user intend to replace the
PCnet-ISA+ with the PCnet-ISA II, care MUST be tak en to
reprogram the EEPROM to reflect the new byte map
structure needed and used by the PCnet-ISA II. For additional information, refer to the section in this data sheet
under
EEPROM
sheet (PID #18183) under the sections entitled
and
Serial EEPROM Byte Map
and the Am79C961 PCnet-ISA+ data
EEPROM
.
Bus Master Mode
System Interface
The PCnet-ISA II controller has two fundamental operating modes, Bus Master and Bus Slave . Within the Bus
Slave mode, the PCnet-ISA II can be prog rammed f or a
Shared Memory or Programmed I/O architecture. The
selection of either the Bus Master mode or the Bus
Slave mode must be done through hard wiring; it is not
software configurable. When in the Bus Sla ve mode, the
selection of the Shared Memory or Programmed I/O
architecture is done through software with the PIOSEL
bit (ISACSR2, bit 13).
The optional Boot PROM is in memory address space
and is expected to be 8–64K. On-chip address comparators control device selection is based on the value in
the EEPROM.
The address PROM, board configuration registers, and
the Ethernet controller occupy 24 bytes of I/O space
and can be located on 16 different starting addresses.
36Am79C961A
PRELIMINARY
ISA
Bus
ISA
Bus
16-Bit
System Data
24-Bit System
Address
16-Bit
System
Data
24-Bit
System
Address
BPCS
SD[0-15]
PCnet-ISA II
Controller
PRDB[2]/EEDO
PRDB[1]/EEDI
PRDB[0]/EESK
SA[0-19]
LA[17-23]
SHFBUSY
Bus Master Block Diagram Plug and Play Compatible
SD[0-15]
PCnet-ISA II
Controller
SA[0-19]
LA[17-23]
IRQ15/APCS IRQ12/FlashWE
PRDB[0]/EESK
PRDB[1]/EEDI
PRDB[2]/EEDO
PRDB[0-7]
EECS
V
CC
BPCS
PRDB[0-7]
EECS
SHFBUSY
CEOE
D[0-7]
Boot
PROM
(Optional)
A[0-15]
DO
DI
EEPROM
SK
(Optional,
CS
V
CC
Common)
ORG
19364A-5
A[0-4]
D[0-7]
IEEE
Address
PROM
(Optional)
A[0-15]
G
WE
D[0-7]
Flash
(Optional)
V
CC
OE
CS
Bus Master Block Diagram Plug and Play Compatible
with Flash and parallel Address PROM Support
Am79C961A37
SK
DI
DO
CS
EEPROM
(Optional,
Common)
ORG
V
CC
19364A-6
PRELIMINARY
Bus Slave Mode
System Interface
The Bus Slave mode is the other fundamental operating mode available on the PCnet-ISA II controller.
Within the Bus Slave mode, the PCnet-ISA II can be
programmed for a Shared Memory or Programmed I/O
architecture. In the Bus Slave mode the PCnet-ISA II
controller uses the same descriptor and buffer architecture as in the Bus Master mode, but these data structures are stored in a static RAM controlled by the
PCnet-ISA II controller. When operating with the
Shared Memory architecture, the local SRAM is visible
as a memory resource on the PC which can be
accessed through memory cycles on the ISA bus interface. When operating with the Programmed I/O architecture, the local SRAM is accessible through I/O
cycles on the ISA bus. Specifically, the SRAM is accessible using the RAP and IDP I/O ports to access the
ISACSR0 and ISACSR1 registers, which serve as the
SRAM Data port and SRAM Address Pointer port,
respectively.
In the Bus Slave mode, the PCnet-ISA II registers and
optional Ethernet physical address PROM look the
same and are accessed in the same way as in the Bus
Master mode.
The Boot PROM is selected by an exter nal device
which drives the Boot PROM Address Match (BP
input to the PCnet-ISA II controller. The PCnet-ISA II
controller can perform two 8-bit accesses from the 8-bit
Boot PROM and present 16-bits of data to accommodate 16 bit read accesses on the ISA bus.
When using the Shared Memory architecture mode,
access to the local SRAM works the same way as
access to the Boot PROM, with an external device generating the Shared Memory Address Match (SMAM)
signal and the PCnet-ISA II controller performing the
SRAM read or write and the 8/16 bit data conversion.
External logic must also drive MEMCS16 appropriately
for the 128Kbyte segment decoded from the LA[23:17]
signals.
AM)
The Programmed I/O architecture mode uses the RAP
and IDP ports to allow access to the local SRAM
hence, external address decoding is not necessary and
the SMAM
ture mode (SMAM should be tied HIGH in the Programmed I/O architecture mode). Similar to the Shared
Memory architecture mode, in the Programmed I/O architecture mode, 8/16 bit conversion occurs when 16
bit reads and writes are performed on the SRAM Data
Port (ISACSR1).
Converting the local SRAM accesses from 8-bit cycles
to 16-bit cycles allows use of the much faster 16-bit
cycle timing while cutting the number of bus cycles in
half. This raises performance to more than 400% of
what could be achieved with 8-bit cycles. When the
Shared Memory architecture mode is used, converting
boot PROM accesses to 16-bit cycles allows the two
memory resources to be in the same 128 Kbyte block
of memory without a clash between two devices with
different data widths.
The PCnet-ISA II prefetches data from the SRAM to
allow fast, minimum wait-state read accesses of consecutive SRAM addresses. In both the Shared Memory
architecture and the Programmed I/O architecture,
prefetch data is read from a speculated address that
assumes that successive reads in time will be from
adjacent ascending addresses in the SRAM. At the
beginning of each SRAM read cycle, the PCnet-ISA II
determines whether the prefetched data can be
assumed to be valid. If the prefetched data can be
assumed to be valid, it is driven onto the ISA bus
without inserting any wait states. If the prefetched data
cannot be assumed to be valid, the PCnet-ISA II will insert wait states into the ISA bus read cycle until the
correct word is read from the SRAM.
pin is not used in Programmed I/O architec-
38Am79C961A
PRELIMINARY
ISA
Bus
16-Bit
System Data
24-Bit System
Address
PRAB[0-15]
SD[0]
PCnet-ISA II
Controller
SA[0]
SHFBUSYBPAM
V
CC
SMAM
PRDB[0]
BPCS
OE
SR
PRDB[2]/EEDO
PRDB[1]/EEDI
PRDB[0]/EESK
EECS
SRWE
IRQ12/SRCS
A[0–15]
(Optional)
WE
CS
DO
DI
SK
CS
A[0-15]
WE
CS
EEPROM
SIN
CLK
BP
AM
SMAM
SHFBUSY
SA[16] LA[17-23]
Flash
SRAM
MEMCS16
External
Glue
Logic
D[0–7]
OE
ORG
OE
D[0-7]
V
CC
19364A-7
Note:
SMAM
shown only for Shared Memory architecture designs. SMAM should be tied HIGH on the PCnet-ISA II for Programmed
I/O architecture designs.
Bus Slave Block Diagram
Plug and Play Compatible with Flash Memory Support
Am79C961A39
PRELIMINARY
PLUG AND PLAY
Plug and Play is a standardized method of configuring
jumperless adapter cards in a system. Plug and Pla y is
a Microsoft standard and is based on a central software
configuration program, either in the operating system
or elsewhere, which is responsible for configur ing all
Plug and Play cards in a system. Plug and Play is fully
supported by the PCnet-ISA II ethernet controller.
For a copy of the Microsoft Plug and Play specification
contact Microsoft Inc. This specification should be
referenced in addition to PCnet-ISA II Technical
Reference Manual and this data sheet.
Operation
If the PCnet-ISA II ethernet controller is used to boot off
the network, the device will come up active at RESET,
otherwise it will come up inactive. Information stored in
the serial EEPROM is used to identify the card and to
describe the system resources required by the card,
such as I/O space, Memory space, IRQs and DMA
channels. This information is stored in a standardized
Read Only format. Operation of the Plug and Play
system is shown as follows:
■ Isolate the Plug and Play card
■ Read the cards resource data
■ Identify the card
■ Configure its resources
The Plug and Play mode of operation allows the following benefits to the end user.
■ Eliminates all jumpers or dip switches from the
adapter card
■ Ease of use is greatly enhanced
■ Allows the ability to uniquely address identical cards
in a system, without conflict
■ Allows the software configuration program or OS to
read out the system resource requirements
required by the card
■ Defines a mechanism to set or modify the current
configuration of each card
■ Maintain backward compatibility with other ISA bus
adapters
Auto-Configuration Ports
Three 8 bit I/O ports are used by the Plug and Play configuration software on each Plug and Play device to
communicate with the Plug and Play registers. The
ports are listed in the table below. The software configuration space is defined as a set of 8 bit registers.
These registers are used by the Plug and Play software
configuration to issue commands, access the resource
information, check status, and configure the PCnet-ISA
II controller hardware.
Port NameLocation
ADDRESS0X279 (Printer Status Port)
WRITE-DATA
READ-DATA
0xA79 (Printer status port +
0x0800)
Relocatable in range
0x0203-0x03FF
Type
Write-only
Write-only
Read-only
The address and Write_DATA por ts are located at
fixed, predefined I/O addresses. The Write_Data port is
located at an alias of the Address port. All three
auto-configuration ports use a 12-bit ISA address
decode.
The READ_DATA por t is relocatable within the range
0x203–0x3FF by a command written to the
WRITE_DATA port.
ADDRESS PORT
The internal Plug and Play registers are accessed by
writing the address to the ADDRESS PORT and then
either reading the READ_DATA PORT or writing to the
WRITE_DATA PORT. Once the ADDRESS PORT has
been written, any number of reads or writes can occur
without having to rewrite the ADDRESS PORT.
The ADDRESS PORT is also the address to which the
initiation key is written to, which is described later.
WRITE_DATA PORT
The WRITE_DATA PORT is the address to which all
writes to the internal Plug and Play registers occur. The
destination of the data written to the WRITE_DATA
PORT is determined by the last value written to the
ADDRESS PORT.
READ_DATA PORT
The READ_DATA PORT is used to read information
from the internal Plug and Play registers. The register
to be read is determined by the last value of the
ADDRESS PORT.
The I/O address of the READ_DATA PORT is set by
writing the chosen I/O location to Plug and Play Register 0. The isolation protocol can deter mine that the
address chosen is free from conflict with other devices
I/O ports.
Initiation Key
The PCnet-ISA II controller is disabled at reset when
operating in Plug and Play mode. It will not respond to
any memory or I/O accesses, nor will the PCnet-ISA II
controller drive any interrupts or DMA channels.
The initiation key places the PCnet-ISA II device into
the configuration mode. This is done by writing a predefined pattern to the ADDRESS PORT. If the proper
sequence of I/O writes are detected by the PCnet-ISA
II device, the Plug and Play auto-configuration ports
are enabled. This pattern must be sequential, i.e., any
40Am79C961A
PRELIMINARY
other I/O access to this I/O port will reset the state
machine which is checking the pattern. Interr upts
should be disabled during this time to eliminate any
extraneous I/O cycles.
The exact sequence for the initiation k ey is listed belo w
in hexadecimal.
A simple algorithm is used to isolate each Plug and
Play card. This algorithm uses the signals on the ISA
bus and requires lock-step operation between the Plug
and Play hardware and the isolation software.
State
Isolation
Read from serial
isolation register
Yes
Drive “55H”
on SD[7:0]
Wait for next read from serial isolation register
Drive “AAH”
on SD[7:0]
Read all 72 bits
No
from serial
identifier
One
Card
Isolated
ID bit = “1H”
After I/O read
completes, fetch
next ID bit from
serial identifier
Yes
Plug and Play ISA Card
Isolation Algorithm
Get one bit from
serial identifier
No
Leave SD in
high-impedance
No
Leave SD in
high-impedance
No
SD[1:0] = “01"
Yes
SD[1:0] = “10"
Yes
ID = 0;
other card
ID = 1
State
Sleep
19364A-8
The key element of this mechanism is that each card
contains a unique number, referred to as the serial
identifier for the rest of the discussion. The serial identifier is a 72-bit unique, non-zero, n umber composed of
two, 32-bit fields and an 8-bit checksum. The first 32-bit
field is a vendor identifier . The other 32 bits can be any
value, for example, a serial number, part of a LAN
address, or a static number , as long as there will never
be two cards in a single system with the same 64 bit
number. The serial identifier is accessed bit-serially by
the isolation logic and is used to differentiate the cards.
The shift order for all Plug and Play serial isolation and
resource data is defined as bit[0], bit[1], and so on
through bit[7].
Hardware Protocol
The isolation protocol can be invoked by the Plug and
Play software at any time. The initiation key, described
earlier, puts all cards into configuration mode. The
hardware on each card expects 72 pairs of I/O read
accesses to the READ_DATA port. The card’s
response to these reads depends on the value of each
bit of the serial identifier which is being examined one
bit at a time in the sequence shown above.
If the current bit of the serial identifier is a “1", then the
card will drive the data bus to 0x55 to complete the first
I/O read cycle. If the bit is “0", then the card puts its data
bus driver into high impedance. All cards in high impedance will check the data bus during the I/O read cycle
to sense if another card is driving D[1:0] to “01". During
the second I/O read, the card(s) that drove the 0x55,
will now drive a 0xAA. All high impedance cards will
check the data bus to sense if another card is driving
D[1:0] to “10". Between pairs of Reads, the software
should wait at least 30 µs.
If a high impedance card sensed another card driving
the data bus with the appropriate data during both
cycles, then that card ceases to participate in the current iteration of card isolation. Such cards, which lose
out, will participate in future iterations of the isolation
protocol.
Note: During each read cycle, the Plug and Play hard-
ware drives the entire 8-bit databus, but only checks
the lower 2 bits.
Am79C961A41
PRELIMINARY
If a card was driving the bus or if the card was in high
impedance and did not sense another card driving the
bus, then it should prepare for the next pair of I/O
reads. The card shifts the serial identifier by one bit and
uses the shifted bit to decide its response. The above
sequence is repeated for the entire 72-bit serial
identifier.
At the end of this process, one card remains. This card
is assigned a handle referred to as the
Number
Cards which have been assigned a CSN will not participate in subsequent iterations of the isolation protocol.
Cards must be assigned a CSN before they will
respond to the other commands defined in the
specification.
It should be noted that the protocol permits the 8-bit
checksum to be stored in non-volatile memory on the
card or generated by the on-card logic in real-time. The
same LFSR algorithm described in the initiation key
section of the Plug and Play specification is used in the
checksum generation.
(CSN) that will be used later to select the card.
Card Select
Software Protocol
The Plug and Play software sends the initiation key to
all Plug and Play cards to place them into configuration
mode. The software is then ready to perform the isolation protocol.
The Plug and Play software generates 72 pairs of l/O
read cycles from the READ_DATA port. The software
checks the data returned from each pair of I/O reads for
the 0x55 and 0xAA driven by the hardware. If both
0x55 and 0xAA are read back, then the software
assumes that the hardware had a “1" bit in that position. All other results are assumed to be a “0.”
During the first 64 bits, software generates a checksum
using the received data. The checksum is compared
with the checksum read back in the last 8 bits of the
sequence.
There are two other special considerations for the software protocol. During an iteration, it is possible that the
0x55 and 0xAA combination is never detected. It is also
possible that the checksum does not match If either of
these cases occur on the first iteration, it must be
assumed that the READ_DATA port is in conflict. If a
conflict is detected, then the READ_DATA port is
relocated. The above process is repeated until a nonconflicting location for the READ_DATA port is found.
The entire range between 0x203 and 0x3FF is available, however in practice it is expected that only a few
locations will be tried before software determines that
no Plug and Play cards are present.
During subsequent iterations, the occurrence of either
of these two special cases should be interpreted as the
absence of any further Plug and Play cards (i.e. the last
card was found in the previous iteration). This
terminates the isolation protocol.
Note:
The software must delay 1 ms prior to starting
the first pair of isolation reads, and must wait 250 µsec
between each subsequent pair of isolation reads. This
delay gives the ISA card time to access information
from possibly very slow storage devices.
Plug and Play Card Control Registers
The state transitions and card control commands for
the PCnet-ISA II controller are shown in the following
figure.
42Am79C961A
PRELIMINARY
Power up
RESET or
Reset Command
Set CSN = 0
(WAKE = 0) AND (CSN = 0)
Lose serial
isolation OR
(WAKE <> CSN)
State
Isolation
Active
Commands
Reset
Wait for Key
Set RD_Data
Port
Serial Isolation
Wake[CSN]
State
Wait for Key
State
SLEEP
Set CSN
Active
Commands
No active
commands
Initiation Key
Active
Commands
Reset
Wait for Key
Wake[CSN]
(WAKE ≠ 0) AND (Wake = CSN)
(WAKE <> CSN)
State
Config
Active
Commands
Reset
Wait for Key
Wake[CSN]
Resource Data
Status
Logical Device
I/O Range Check
Activate
Configuration
Registers
Notes
1. CSN = Card Select Number
2. RESET or the Reset command causes a state transition from the current state to Wait for Key and sets all CSNs to zero.
3. The Wait for Key command causes a state transition from the current state to Wait for Key.
19364A-10
Plug and Play ISA Card State Transitions
Plug and Play Registers
The PCnet-ISA II controller supports all of the defined
Plug and Play card control registers. Refer to the tables
on the following pages for detailed information.
Am79C961A43
PRELIMINARY
Plug and Play Standard Registers
Address
Name
Set RD_DATA P ort0x00Writing to this location modifies the address of the port used for reading from the
Serial Isolation0x01A read to this register causes a Plug and Play card in the
Config Control0x02Bit[0] - Reset all logical devices and restore configuration registers to their
Wake[CSN]0x03A write to this port will cause all cards that have a CSN that matches the write
Resource Data0x04A read from this address reads the next byte of resource information. The Status
Status0x05Bit[0] when set indicates it is okay to read the next data byte from the Resource
Card Select Number0x06A write to this port sets a card’s CSN. The CSN is a value uniquely assigned to
Logical Device Number0x07Selects the current logical device. This register is read only. The PCnet-ISA II
Port ValueDefinition
Plug and Play ISA cards. Bits[7:0] become I/O read port address bits [9:2].
Reads from this register are ignored. I/O Address bits 11:10 should = 00, and 1:0
= 11.
compare one bit of the board’s ID. This process is fully described above. This
register is read only.
power-up values.
Bit[1] - Return to the
Bit[2] - Reset CSN to 0
A write to bit[0] of this register performs a reset function on all logical devices. This
resets the contents of configuration registers to their default state. All card’s
logical devices enter their default state and the CSN is preserved.
A write to bit[1] of this register causes all cards to enter the
all CSNs are preserved and logical devices are not affected.
A write to bit[2] of this register causes all cards to reset their CSN to zero.
This register is write-only. The values are not sticky, that is, hardware will
automatically clear them and there is no need for software to clear the bits.
data[7:0] to go from the
for this command is zero or the
register is write-only. Writing to this register resets the EEPROM pointer to the
beginning of the Plug and Play Data Structure.
register must be polled until bit[0] is set before this register may be read. This
register is read-only.
Data register. This register is read-only.
each ISA card after the serial identification process so that each card may be
individually selected during a Wake [CSN] command. This register is read/write.
controller has only 1 logical device, and this register contains a value of 0x00
Wait for Key
Sleep
state to either the
Config
state
state if the write data is not zero. This
Isolation
Isolation
Wait for Ke y
state if the write data
state to
state but
44Am79C961A
PRELIMINARY
Plug and Play Logical Device
Configuration Registers
The PCnet-ISA II controller supports a subset of the
defined Plug and Play logical device control registers.
The reason for only supporting a subset of the registers
is that the PCnet-ISA II controller does not require as
many system resources as Plug and Play allows. For
Plug and Play Logical Device Control Registers
Address
Name
Activate0x30For each logical device there is one activate register that controls whether or
I/O Range Check0x31This register is used to perform a conflict check on the I/O port range
Port ValueDefinition
not the logical device is active on the ISA bus . Bit[0], if set, activates the logical
device. Bits[7:1] are reserved and must be zero. This is a read/write register.
Before a logical device is activated, I/O range check must be disabled.
programmed for use by a logical device.
Bit[7:2] Reserved
Bit 1[1] Enable I/O Range check, if set then I/O Range Check is enabled. I/O
range check is only valid when the logical device is inactive.
Bit[0], if set, forces the logical device to respond to I/O reads of the logical
device’s assigned I/O range with a 0x55 when I/O range check is in operation.
If clear, the logical device drives 0xAA. This register is read/write.
instance, Memory Descriptor 2 is not used, as the
PCnet-ISA II controller only requires two memory
descriptors, one for the Boot PROM/Flash, and one f or
the SRAM in Shared Memory Mode.
Memory Space Configuration
Register
Name
Memory base address
bits[23:16] descriptor 0
Memory base address
bits [23:16] descriptor 0
Memory control0x42Bit[1] specifies 8/16-bit control. The encoding relates to memory control
Memory upper limit
address;
bits [23:16] or range
length;
bits [15:08] for
descriptor 0
Memory upper limit
bits [15:08] or range
length;
bits [15:08] for
descriptor 0
Memory descriptor 10x48-0x4CMemory descriptor 1. This is the SRAM Space for Shared Memory.
IndexDefinition
0x40Read/write value indicating the selected memory base address bits[23:16] for
memory descriptor 0. This is the Boot Prom Space.
0x41Read/write value indicating the selected memory base address bits[15:08] for
memory descriptor 0.
(bits[4:3]) of the information field in the memory descriptor.
Bit[0], =0, indicates the next field is used as a range length for decode
(implies range length and base alignment of memory descriptor are equal).
Bit[0] is read-only.
0x43Read/write value indicating the selected memory high address bits[23:16] for
memory descriptor 0.
If bit[0] of memory control is 0, this is the range length.
If bit[0] of memory control is 1, this is considered invalid.
0x44Read/write value indicating the selected memory high address bits[15:08] for
memory descriptor 0, either a memory address or a range length as described
above.
Name
I/O port base address
bits[15:08] descriptor 0
I/O Space ConfigurationI/O Interrupt Configuration
Register
IndexDefinition
0x60Read/write value indicating the selected I/O lower limit address bits[15:08] for
I/O descriptor 0. If a logical device indicates it only uses 10 bit encoding, then
bits[15:10] do not need to be supported.
Am79C961A45
PRELIMINARY
Register
Name
I/O port base address
bits[07:00] descriptor 0
Name
Interrupt request level
select 0
Interrupt request type
select 0
IndexDefinition
0x61Read/write value indicating the selected I/O lower limit address bits[07:00] for
I/O descriptor 0.
Register
IndexDefinition
Read/write value indicating selected interrupt level. Bits[3:0] select which interrupt
0x70
0x71
level used for Interrupt 0. One selects IRQL 1, fifteen selects IRQL fifteen. IRQL 0 is
not a valid interrupt selection and represents no interrupt selection.
Read/write value indicating which type of interrupt is used for the Request Level
selected above.
Bit[1] : Level, 1 = high,0=low
Bit[0] : Type, 1 = level, 0 = edge
The PCnet-ISA II controller only supports Edge High and Level Low Interrupts.
DMA Channel Configuration
Register
Name
DMA channel select 00x74
DMA channel select 10x75Read only with a value of 0x04.
IndexDefinition
Read/write value indicating selected DMA channels. Bits[2:0] select which DMA
channel is in use for DMA 0. Zero selects DMA channel 0, seven selects DMA channel
7. DMA channel 4, the cascade channel is used to indicate no DMA channel is activ e.
DETAILED FUNCTIONS
EEPROM
Interface
The EEPROM supported by the PCnet-ISA II controller
is an industry standard 93C56 2-Kbit EEPROM device
which uses a 4-wire interface. This device directly interfaces to the PCnet-ISA II controller through a 4-wire
interface which uses 3 of the private data bus pins for
Data In, Data Out, and Serial Clock. The Chip Select
pin is a dedicated pin from the PCnet-ISA II controller.
Note: All data stored in the EEPROM is stored in
bit-reversal format. Each word (16 bits) must be written
into the EEPROM with bit 15 swapped with bit 0, bit 14
swapped with bit 1, etc.
This is a 2-Kbit device organized as 128 x 16 bit words.
A map of the device as used in the PCnet-ISA II controller is below. The information stored in the EEPROM
is as follows:
IEEE address 6 bytes
Reserved10 bytes
EISA ID4 bytes
ISACSRs14 bytes
Plug and Play Defaults19 bytes
8-Bit Checksum1 byte
External Shift Chain2 bytes
Plug and Play Config Info192 bytes
Important Note About The EEPROM
Byte Map
The user is cautioned that while the Am79C961A
(PCnet-ISA II) and its associated EEPROM are pin
compatible to their predecessors the Am79C961
(PCnet-ISA+) and its associated EEPROM, the byte
map structure in each of the EEPROMs are different
from each other.
The EEPROM byte map structure used for the
Am79C961A PCnet-ISA II has the addition of “MISC
Config 2, ISACSR9" at word location 10Hex. The
EEPROM byte map structure used for the Am79C961
PCnet-ISA+ does not have this.
Therefore, should the user intend to replace the
PCnet-ISA
to reprogram the EEPROM to reflect the new b yte map
structure needed and used by the PCnet-ISA II. For
additional information, refer to the Am79C961
PCnet-ISA+ data sheet (PID #18183) under the sections entitled
+
with the PCnet-ISA II, care MUST be taken
EEPROM
and
Serial EEPROM Byte Map
.
46Am79C961A
PRELIMINARY
Basic EEPROM Byte Map
The following is a byte map of the XXC56 series of
EEPROMs used by the PCnet-ISA II Ethernet
STATUS
0x06CSN
0x07LOGICAL DEVICE NUMBER
0x300000000 ACTIVATE
0x31000000IORNGIORNG
READ_DATAAddress of Plug and Play READ_DATA Port.
SERIAL_ISOLATIONUsed in the Serial Isolation process.
RST_CSNResets CSN register to zero.
WAIT_KEYResets Wait for Key State.
RST_ALLResets all logical devices.
WAKE [CSN]Will wake up if write data matches CSN Register.
READ_STATUSRead Status of RESOURCE DATA.
RESOURCE_DATANext pending byte read from EEPROM.
CSNPlug and Play CSN Value.
ACTIVATEIndicates that the PCnet-ISA II device should be activated.
IORNGBits used to enable the I/O Range Check Command.
Am79C961A49
PRELIMINARY
The following chart and its bit descriptions show the
internal command registers associated with the Plug
and Play operation. These registers control the
PCnet-ISA II controller Plug and Play operation.
PCnet–ISA II’s Legacy Bit Feature
Description
The current PCnet-ISA II chip is designed such that it
always responds to Plug and Play configuration software. There are situations where this response to the
Plug and Play software is undesirable. An example of
this is when a fixed configuration is required, or when
the only possible resource available for the PCnet-ISA
II conflicts with a present but not used resource such as
IRQ, or when the chip is used in a system with a buggy
PnP BIOS.
To function in the situations above, a new feature has
been added to the PCnet-ISA II chip. This new feature
makes the chip ignore the PnP software’s special initiation key sequence (6A). This will effectively turn the
chip into the “Legacy” mode operation, where it will be
visible in the I/O space, and only special setup programs will be able to reconfigure it. In case the
EEPROM is missing, empty, or corrupted, the chip will
still recognize AMD’s special initiation key sequence
(6B).
To enable this feature, a one has to be written into the
LGCY_EN bit, which is bit 6 of the Plug and Play register 0xF0. A preferred method would be set this bit in
the Vendor Byte (PnP 0xF0) field of the EEPROM
located in word offset 0x1A.
50Am79C961A
PRELIMINARY
Plug & Play Register Locations Detailed
Description (Refer to the Plug & Play
Register Map above).
IOAM[3:0]I/O Address Match to bits [8:5] of SA
bus (PnP 0x60–0x61). Controls the
base address of PCnet-ISA II. The
IOAM will be written with a value
from the EEPROM.
0x70). Controls which interrupt will
be asserted. ISA Edge sensitive or
EISA level mode is controlled by
IRQ_TYPE bit in PnP 0x71. Default
is ISA Edge Sensitive. The IRQ signals will not be driven unless PnP
activate register bit is set.
register bit that indicates the type of
setting, active high or low. Always
complement of IRQ_TYPE.
DMA[2:0]DMA Channel Select (PnP 0x74).
Controls the DRQ and DMA selection of PCnet-ISA II. The DMA[2:0]
register will be written with a value
from the EEPROM. {For Bus Master
Mode Only} The DRQ signals will
not be driven unless Plug and Play
activate register bit is set.
[16:13] of SA bus (PnP 0x40–0x41).
Selects the location where the Boot
PROM Address match decode is
started. The BPAM will be written
with a value from the EEPROM.
0x42). Is asser ted if Boot PROM
cycles should respond as an 16-bit
device. In Bus Master mode, all boot
PROM cycles will only be 8 bits in
width.
BPSZ[3:0]Boot PROM Size (PnP 0x43–0x44).
Selects the size of the boot PROM
selected.
BPSZ[3:0]Boot PROM Size
0xxxNo Boot PROM Selected
11118 K
111016 K
110032 K
100064 K
SRAM[4:0]Static RAM Address Match to bits
[17:13] of SA bus (PnP 0x48-0x49).
Selects the starting location of the
Shared Memory when using the
Am79C961A51
PRELIMINARY
Shared Memory architecture mode.
The SRAM[2:0] bits are used for performing address decoding on the
SA[15:13] address bits as shown in
the table below. SRAM[4] and
SRAM[3] must reflect the external
address match logic for SA[17] and
SA[16], respectively. The SRAM[4:0]
bits are ignored when in the Bus
Master mode or in the Programmed
I/O Architecture mode.
0x4A). If asserted, the PCnet-ISA II
will respond to SRAM cycles as a
16-bit device. This bit should be set
if external logic is designed to assert
the MEMCS16
signal when
accesses to the shared memory are
decoded. This bit is ignored when in
the Bus Master mode or in the Programmed I/O Architecture mode.
SRSZ[3:0]Static RAM size (PnP 0x4B-0x4C).
Selects the size of the static RAM.
The SRSZ[3:0] bits are ignored
when in the Bus Master mode or in
the Programmed I/O Architecture
mode.
SRSZ[3:0]Shared Memory Size
0xxxNo Static RAM Selected
11118 K
111016 K
110032 K
100064 K
Vendor Defined Byte (PnP 0xF0)
LGCY_ENLegacy mode enable. When written
with a one, the PCnet-ISA II will not
respond to the Plug and Play initiation key sequence (6A) but will
respond to the AMD key sequence
(6B). Therefore, it cannot be reconfigured by the Plug and Play software. When set to zero (default), the
PCnet-ISA II will respond to the 6A
key sequence if the EEPROM read
was successful, otherwise it will respond to the 6B key sequence.
DXCVRPDXCVR Polarity. The DXCVRP bit
sets the polarity of the DXCVR pin.
When DXCVRP is cleared (default),
the DXCVR pin is driven HIGH when
the Twisted Pair por t is active or
SLEEP mode has been entered and
driven LOW when the AUI port is
active. When DXCVRP is set, the
DXCVR pin is driven LOW when the
Twisted Pair port is active or SLEEP
mode has been entered and driven
HIGH when the AUI port is active.
The DXCVRP should generally be
left cleared when the PCnet-ISA II is
being used with an external DC-DC
conver ter that has an active low
enable pin. The DXCVRP should
generally be set when the
PCnet-ISA II is being used with an
external DC-DC converter that has
an active high enable pin.
IO_MODEI/O Mode. When set to one, the
internal selection will respond as a
16-bit port, (i.e. drive IOCS16 pin).
When IO_MODE is set to zero,
(Default), the internal I/O selection
will respond as an 8-bit port.
AEN_CSExter nal Decode Logic for I/O Reg-
isters. When written with a one, the
PCnet-ISA II will use the AEN pin as
I/O chip select bar, to allow f or e xternal decode logic for the upper address bit of SA [9:5]. The purpose of
this pin is to allow I/O locations, not
supported with the IOAM[3:0],
selection, to be defined outside the
range 0x200–0x3F7. When set to a
zero, (Def ault), I/O Selection will use
IOAM[3:0].
APROM_ENExternal Parallel IEEE Address
PROM. When set, the IRQ15 pin is
reconfigured to be an Address Chip
Select low , similar to APCS pin in the
existing PCnet-ISA (Am79C960)
device. The purpose of this bit is to
allow for both a serial EEPROM and
parallel PROM to coexist. When
APROM_EN is set, the IEEE
address located in the serial EEPROM will be ignored and parallel
access will occur over the PRDB
bus. When APROM_EN is cleared,
52Am79C961A
PRELIMINARY
default state, the IEEE address will
be read in from the serial device and
written to an internal RAM. When
the I/O space of the IEEE PROM is
selected, PCnet-ISA II, will access
the contents of this RAM for I/O read
cycles. I/O write cycles will be
ignored.
BP_CSBoot PROM Chip Select. When
BP_CS is set to one, BALE will act
as an external chip select (active
low) above bit 15 of the address b us.
BALE = 0, will select the boot PROM
when MEMR
BP_CS bit is set and BPAM[2:0]
match SA[15:13] and BPSZ[3:0]
matches the selected size. When
BP_CS is set to zero. BALE will act
as the normal address latch strobe
to capture the upper address bits for
memory access to the boot PROM.
BP_CS is by default low. The primary purpose of this bit is to allow
non-ISA bus applications to support
larger Boot PROMS or non-standard
Boot PROM/Flash locations.
FL_SELFlash Memory Device Selected.
When set, the Boot PROM is
replaced with an external Flash
memory device. In Bus Master
Mode, BPCS is replaced with
Flash_OE. IRQ12 becomes
Flash_WE. The Flash’s CS pin is
grounded. In shared memory mode,
BPCS is replaced with Flash_CS.
IRQ12 becomes Static_RAM_CS
pin. The SROE and SRWE signals
are connected to both the SRAM
and Flash memory devices. FL_SEL
is cleared by a reset, which is the
default.
is asserted low if the
Checksum Failure
After RESET, the PCnet-ISA II controller begins
reading the EEPROM and storing the information in
registers inside PCnet-ISA II controller. PCnet-ISA II
controller does a checksum on word locations 0-1Bh
inclusive and if the byte checksum = FFh, then the
data read from the EEPROM is considered good. If
the checksum is not equal to FFh, then the
PCnet-ISA II controller enters what is called software
relocatable mode.
In software relocatable mode, the device functions the
same as in Plug and Play mode, e xcept that it does not
respond to the same initiation key as Plug and Play
supports. Instead, a different key is used to bring
PCnet-ISA II controller out of the Wait For Key state.
This key is as follows:
In some designs, especially PC motherboard applications, it may be desirable to eliminate the
EEPROM altogether. This would save money, space,
and power consumption.
The operation of this mode is similar to when the
PCnet-ISA II controller encounters a checksum error,
except that to enter this mode the SHFBUSY pin is left
unconnected. The device will enter software relocatable mode, and the BIOS on the motherboard can
wake up the device , configure it, load the IEEE address
(possibly stored in Flash ROM) into the PCnet-ISA II
controller, and activate the device.
External Scan Chain
The External Scan Chain is a set of bits stored in the
EEPROM which are not used in the PCnet-ISA II controller but which can be used with external hardware to
allow jumperless configuration of external devices.
After RESET, the PCnet-ISA II controller
begins reading the EEPROM and storing the information in registers inside the PCnet-ISA II
controller. SHFBUSY is held high during the read of the
EEPROM. If external circuitry is added, such as a shift
register, which is clock ed from SCLK and is attached to
DO from the EEPROM, data read out of the EEPROM
will be shifted into the shift register. After reading the
EEPROM to the end of the External Shift Chain, and if
there is a correct checksum, SHFBUSY will go low.
This will be used to latch the infor mation from
the EEPROM into the shift register. If the checksum is
invalid, SHFBUSY will not go low, indicating that the
EEPROM may be bad.
Flash PROM
Use
Instead of using a PROM or EPROM for the Boot
PROM, it may be desirab le to use a Flash or EEPR OM
type of device for storing the Boot code. This would
allow for in-system updates and changes to the information in the Boot ROM without opening up the PC. It
may also be desirable to store statistics or drivers in the
Flash device.
Interface
To use a Flash-type device with the PCnet-ISA
II controller, Flash Select is set in register 0F0h of the
Am79C961A53
PRELIMINARY
Plug and Play registers. Flash Select is cleared
by RESET (default).
In bus master mode, BPCS becomes Flash_OE and
IRQ12 becomes Flash_WE. The Flash ROM devices
CS pin is connected to ground.
In shared memory mode, BPCS becomes Flash_CS
and IRQ12 becomes the static RAM Chip Select, and
the SROE and SRWE signals are connected to both
the SRAM and Flash devices.
Optional IEEE Address PROM
Normally, the Ethernet physical address will be stored
in the EEPROM with the other configuration data. This
reduces the parts count, board space requirements,
and power consumption. The option to use a standard
parallel 8 bit PROM is provided to manufacturers who
are concerned about the non-volatile nature
of EEPROMs.
To use a 8 bit parallel PROM to store the IEEE address
data instead of storing it in the EEPROM, the
APROM_EN bit is set in the Plug and Play registers by
the EEPROM upon RESET. IRQ15 is redefined by the
setting of this bit to be APCS
CHIP SELECT. This pin is connected to an exter nal 8
bit PROM, such as a 27LS19. The address pins of the
PROM are connected to the lower address pins of the
ISA bus, and the data lines are connected to the private
data bus.
In this mode, any accesses to the IEEE address will be
passed to the external PROM and the data will be
passed through the PCnet-ISA II controller to
the system data bus.
, or ADDRESS PROM
EISA Configuration Registers
The PCnet-ISA II controller has support for the 4-byte
EISA Configuration Registers. These are used in EISA
systems to identify the card and load the appropriate
configuration file for that card. This feature is enabled
using bit 10 of ISACSR2. When set to 1, the EISA Configuration registers will be enabled and will be read at
I/O location 0xC80–0xC83. The contents of these 4
registers are stored in the EEPROM and are automatically read in at RESET.
Bus Interface Unit (BIU)
The bus interface unit is a mixture of a 20 MHz state
machine and asynchronous logic. It handles two types
of accesses; accesses where the PCnet-ISA II controller is a slave and accesses where the PCnet-ISA II controller is the Current Master.
In slave mode, signals like IOCS16 are asserted and
deasserted as soon as the appropriate inputs
are received. IOCHRDY is asynchronously driven LOW
if the PCnet-ISA II controller needs a wait state. It is
released synchronously when the PCnet-ISA II controller is ready.
When the PCnet-ISA II controller is the Current Master,
all the signals it generates are synchronous to the
on-chip 20 MHz clock.
DMA T ransfers
The BIU will initiate DMA transfers according to the
type of operation being performed. There are three primary types of DMA transfers:
1. Initialization Block DMA Transfers
During initialization, the PCnet-ISA II transfers 12
words from the initialization block in memory to internal
registers. These 12 words are transferred through different bus mastership period sequences, depending on
whether the TIMER bit (CSR4, bit 13) is set and, if
TIMER is set, on the value in the Bus Activity Timer
register (CSR82).
If the TIMER bit is reset (default), the 12 words are
always transferred during three separate bus mastership periods. During each bus mastership period, four
words (8 bytes) will be read from contiguous memory
addresses.
If the TIMER bit is set, the 12 words ma y be transf erred
using anywhere from 1 to 3 bus mastership periods,
depending on the value of the Bus Activity Timer register (CSR82). During each bus mastership period, a
minimum of four words (8 bytes) will be read from contiguous memory addresses. If the TIMER bit is set and
the value in the Bus Activity Timer register allows it, 8
or all 12 words of the initialization block are read during
a single bus mastership period.
2. Descriptor DMA Transfers
Descriptor DMA transfers are performed to read or
write to transmit or receive descriptors. All transmit and
receive descriptor READ accesses require 3 word
reads (TMD1, TMD0, then TMD2 for transmit descriptors and RMD1, RMD0, then RMD2 for receive descriptors). Tr ansmit and receive descriptor WRITE accesses
to unchained descriptors or the last descriptor in a
chain (ENP set) require 2 word writes (TMD1 then
TMD3 for transmit and RMD1 then RMD3 for receive).
Transmit and receive descriptor WRITE accesses to
chained descriptors that do not have ENP set require 1
word write (TMD1 for transmit and RMD1 for receive).
During descriptor write accesses, only the bytes which
need to be written are written, as controlled by the SA0
and SBHE
If the TIMER bit is reset (default), all accesses during a
single bus mastership period will be either all read or all
write and will be to only one descriptor. Hence, when
the TIMER bit is reset, the bus mastership periods for
descriptor accesses are always either 3, 2, or 1 cycles
pins.
54Am79C961A
PRELIMINARY
long, depending on which descriptor operation is being
performed.
If the TIMER bit is set, the 3, 2, or 1 cycles required in
a descriptor access may be performed as a part of a
bus mastership period in which any combination of
descriptor reads and writes and buffer reads and writes
are performed. When the TIMER bit is set, the Bus
Activity Timer (CSR82) and the bus access requirements of the PCnet-ISA II govern the operations performed during a single bus mastership period.
3. FIFO DMA Transfers
FIFO DMA transfers occur when the PCnet-ISA II
microcode determines that transfers to and/or from the
FIFOs are required. Once the PCnet-ISA II BIU has
been granted bus mastership , it will perf orm a series of
consecutive transfer cycles before relinquishing the
bus.
When the Bus Activity Timer is disabled b y clearing the
TIMER (CSR4, bit 13) bit, all FIFO DMA transfers
within a bus mastership period will be either read or
write cycles, and all transfers will be to adjacent,
ascending addresses. When the Bus Activity Timer is
enabled by setting the TIMER bit, DMA tr ansf ers within
a bus mastership period may consist of any mixture of
read and write cycles, without restriction on the
address ordering. This mode of operation allows the
PCnet-ISA II to accomplish more during each bus
ownership period.
The number of data transfer cycles contained within a
single bus mastership period is in general dependent
on the programming of the DMAPLUS (CSR4, bit 14)
and the TIMER (CSR4, bit 13) options. Several other
factors will also affect the length of the bus mastership
period. The possibilities are as follows:
If DMAPLUS = 0 and TIMER = 0, a maximum of 16
transfers to or from the FIFO will be perfor med by
default. This default v alue ma y be changed by writing to
the DMA Burst Register (CSR80, bits 7:0). Since
TIMER = 0, all FIFO DMA transfers within a bus mastership period will be either read or write cycles, and all
transfers will be to adjacent, ascending addresses.
Note that DMAPLUS = 0 merely sets a maximum value
for the number of FIFO transf ers that may occur during
one bus mastership period. The minimum number of
transfers in the bus mastership period will be determined by the settings of the FIFO watermarks and the
conditions of the FIFOs, and the value of the Bus Activity Timer (CSR82) if the TIMER bit is set.
If DMAPLUS = 1 and TIMER = 0, the bus mastership
period will continue until the transmit FIFO is filled to its
high threshold (read transfers) or the receive FIFO is
emptied to its low threshold (write transfers). Other
variables may also affect the end point of the bus mastership period in this mode, including the particular
conditions existing within the FIFOs, and receive and
transmit status conditions. Since TIMER = 0, all FIFO
DMA transfers within a bus mastership period will be
either read or write cycles, and all transfers will be to
adjacent, ascending addresses.
If TIMER = 1, the bus mastership period will continue
until all “pending bus operations” are completed or until
the Bus Activity Timer value (CSR82) has expired.
These bus operations may consist of any mixture of
descriptor and buffer read and write accesses. If DMAPLUS = 1, “pending bus operations” includes any descriptor accesses and buffer accesses that need to be
performed. If DMAPLUS = 0, “pending bus operations”
include any descriptor accesses that need to be performed and any buffer accesses that need to be performed up to the limit specified by the DMA Burst
Register (CSR80, bits 7:0).
Note that when TIMER=1, following a last bus transaction during a bus mastership period, the PCnet-ISA II
may keep ownership of the b us for up to approximately
1µs. The PCnet-ISA II deter mines whether there are
further pending bus operations by waiting approximately 1µs after the completion of every bus operation
(e.g. a descriptor or FIFO access). If, during the 1 µs
period, no further bus operations are requested by the
internal Buffer Management Unit, the PCnet-ISA II
determines that there are no further pending operations and gives up bus ownership. This 1 µs of unused
bus ownership time is more than made up for by the
efficiency gained by being able to perform any mixture
of descriptor and buffer read and write accesses during
a single bus ownership period.
The FIFO thresholds are programmable (see description of CSR80), as are the DMA Burst Register and Bus
Activity Timer values. The exact number of transfer
cycles in the case of DMAPLUS = 1 will be dependent
on the latency of the system bus to the PCnet-ISA II
controller’s DMA request and the speed of bus operation, but will be limited by the value in the Bus Activity
Timer register (if the TIMER bit is set), the FIFO condition, and receive and transmit status. Barring a time-out
by either of these registers, or exceptional receive and
transmit events, or an end of packet signal from the
FIFO, the FIFO watermark settings and the extent of
Bus Grant latency will be the major factors determining
the number of accesses performed during any given
arbitration cycle when DMAPLUS = 1.
The IOCHRD Y response of the memory device will also
affect the number of transfers when DMAPLUS = 1,
since the speed of the accesses will affect the state of
the FIFO. Dur ing accesses, the FIFO may be filling or
emptying on the network end. A slower memory
response will allow additional data to accumulate
inside of the FIFO (during write transfers from the
receive FIFO). If the accesses are slow enough, a complete word may become av ailab le bef ore the end of the
arbitration cycle and thereby increase the number of
Am79C961A55
PRELIMINARY
transfers in that cycle. The general rule is that the
longer the Bus Grant latency or the slower the bus
transfer operations (or clock speed) or the higher the
transmit watermark or the lower the receive watermark
or any combination thereof, the longer will be the average bus mastership period.
Buffer Management Unit (BMU)
The buffer management unit is a microcoded 20 MHz
state machine which implements the initialization block
and the descriptor architecture.
Initialization
PCnet-ISA II controller initialization includes the reading of the initialization block in memory to obtain the
operating parameters. The initialization block is read
when the INIT bit in CSR0 is set. The INIT bit should be
set before or concurrent with the STRT bit to insure correct operation. See previous section “1. Initialization
Block DMA Transfer.” Once the initialization block has
been read in and processed, the BMU knows where
the receive and transmit descriptor rings are. On completion of the read operation and after internal registers
have been updated, IDON will be set in CSR0, and an
interrupt generated if IENA is set.
The Initialization Block is vectored by the contents of
CSR1 (least significant 16 bits of address) and CSR2
(most significant 8 bits of address). The block contains
the user defined conditions for PCnet-ISA II controller
operation, together with the address and length information to allow linkage of the transmit and receive
descriptor rings.
There is an alternative method to initialize the
PCnet-ISA II controller. Instead of initialization via the
initialization block in memory, data can be written
directly into the appropriate registers. Either method
may be used at the discretion of the programmer. If the
registers are written to directly , the INIT bit m ust not be
set, or the initialization block will be read in, thus overwriting the previously written information. Please refer
to Appendix D for details on this alternative method.
Reinitialization
The transmitter and receiver section of the PCnet-ISA
II controller can be turned on via the initialization block
(MODE Register DTX, DRX bits; CSR15[1:0]). The
state of the transmitter and receiver are monitored
through CSR0 (RXON, TXON bits). The PCnet-ISA II
controller should be reinitialized if the transmitter and/
or the receiver were not turned on during the original
initialization and it was subsequently required to activate them, or if either section shut off due to the detection of an error condition (MERR, UFLO, TX BUFF
error).
Reinitialization may be done via the initialization block
or by setting the STOP bit in CSR0, followed by writing
to CSR15, and then setting the START bit in CSR0.
Note that this form of restart will not perform the same
in the PCnet-ISA II controller as in the LANCE. In particular, the PCnet-ISA II controller reloads the transmit
and receive descriptor pointers (working registers) with
their respective base addresses. This means that the
software must clear the descriptor’s o wn bits and reset
its descriptor ring pointers before the restart of the
PCnet-ISA controller. The reload of descriptor base
addresses is performed in the LANCE only after initialization, so a restart of the LANCE without initialization
leaves the LANCE pointing at the same descriptor
locations as before the restart.
Suspend
The PCnet-ISA II controller offers a suspend mode that
allows easy updating of the CSR registers without
going through a full reinitialization of the device. The
suspend mode also allows stopping the device with
orderly termination of all network activity.
The host requests the PCnet-ISA II controller to enter
the suspend mode by setting SPND (CSR5, bit 0) to
ONE. The host must poll SPND until it reads back ONE
to determine that the PCnet-ISA II controller has entered the suspend mode. When the host sets SPND to
ONE, the PCnet-ISA II controller first finishes all
on-going transmit activity and updates the corresponding transmit descriptor entries. It then finishes all
on-going receive activity and updates the corresponding receive descriptor entries. It then sets the
read-version of SPND to ONE and enters the suspend
mode. In suspend mode, all of the CSR registers are
accessible. As long as the PCnet-ISA II controller is not
reset while in suspend mode (by asserting the RESET
pin, reading the RESET register, or by setting the
STOP bit), no reinitialization of the device is required
after the device comes out of suspend mode. When
SPND is set to ZERO, the PCnet-ISA II controller will
leave the suspend mode and will continue at the transmit and receive descriptor ring locations where it had
left when it entered the suspend mode.
Buffer Management
Buffer management is accomplished through message
descriptor entries organized as ring structures in memory. There are two rings, a receive ring and a transmit
ring. The size of a message descriptor entry is 4 words
(8 bytes).
Descriptor Rings
Each descriptor ring must be organized in a contiguous
area of memory. At initialization time (setting the INIT
bit in CSR0), the PCnet-ISA II controller reads the
user-defined base address for the transmit and receive
descriptor rings, which must be on an 8-byte boundary ,
as well as the number of entries contained in the
descriptor rings. By default, a maximum of 128 ring
entries is permitted when utilizing the initialization
block, which uses values of TLEN and RLEN to specify
56Am79C961A
PRELIMINARY
the transmit and receive descriptor ring lengths. However, the ring lengths can be manually defined (up to
65535) by writing the transmit and receive ring length
registers (CSR76,78) directly.
Each ring entry contains the following information:
■ The address of the actual message data buffer in
user or host memory
■ The length of the message buffer
■ Status information indicating the condition of the
buffer
Receive descriptor entries are similar (but not identical)
to transmit descriptor entries. Both are composed of
four registers, each 16 bits wide for a total of 8 bytes.
To permit the queuing and de-queuing of message
buffers, ownership of each buffer is allocated to either
the PCnet-ISA II controller or the host. The OWN bit
within the descriptor status information, either TMD or
RMD (see section on TMD or RMD), is used for this
purpose. “Deadly Embrace” conditions are avoided by
the ownership mechanism. Only the owner is permitted
to relinquish ownership or to write to any field in the
descriptor entry. A device that is not the current owner
of a descriptor entry cannot assume ownership or
change any field in the entry.
Descriptor Ring Access Mechanism
At initialization, the PCnet-ISA II controller reads the
base address of both the transmit and receive descriptor rings into CSRs for use by the PCnet-ISA II controller during subsequent operation.
When transmit and receive functions begin, the base
address of each ring is loaded into the current descriptor address registers and the address of the next
descriptor entry in the transmit and receive rings is
computed and loaded into the next descriptor address
registers.
When there is no channel activity and there is no preor post-receive or transmit activity being performed by
the PCnet-ISA II controller then the PCnet-ISA II controller will periodically poll the current receive and
transmit descriptor entries in order to ascertain their
ownership. If the DPOLL bit in CSR4 is set, then the
transmit polling function is disabled.
A typical polling operation consists of the following: The
PCnet-ISA II controller will use the current receive
descriptor address stored internally to vector to the
appropriate Receive Descriptor Table Entry (RDTE). It
will then use the current transmit descriptor address
(stored internally) to vector to the appropriate Transmit
Descriptor Table Entry (TDTE). These accesses will be
made to RMD1 and RMD0 of the current RDTE and
TMD1 and TMD0 of the current TDTE at per iodic poll-
58Am79C961A
TMD0
Data
Buffer 1
TMD1
TMD2
Data
Buffer 2
TMD3
TMD0
•••
Data
Buffer
M
19364A-11
PRELIMINARY
ing intervals. All information collected during polling
activity will be stored internally in the appropriate
CSRs. (i.e. CSR18–19, CSR40, CSR20–21, CSR42,
CSR50, CSR52). Unowned descriptor status will be
internally ignored.
A typical receive poll occurs under the following
conditions:
1. PCnet-ISA II controller does not possess ownership
of the current RDTE and
the poll time has elapsed and
RXON = 1,
or
2. PCnet-ISA II controller does not possess ownership
of the next RDTE and
the poll time has elapsed and
RXON = 1,
If RXON = 0, the PCnet-ISA II controller will never poll
RDTE locations.
If RXON = 1, the system should always have at least
one RDTE available for the possibility of a receive
event. When there is only one RDTE, there is no polling
for next RDTE.
A typical transmit poll occurs under the following
conditions:
1. PCnet-ISA II controller does not possess ownership
of the current TDTE and
DPOLL = 0 and
TXON = 1 and
the poll time has elapsed,
or
2. PCnet-ISA II controller does not possess ownership
of the current TDTE and
DPOLL = 0 and
TXON = 1 and
a packet has just been received,
or
3. PCnet-ISA II controller does not possess ownership
of the current TDTE and
DPOLL = 0 and
TXON = 1 and
a packet has just been transmitted.
The poll time interval is nominally defined as 32,768
crystal clock periods, or 1.6 ms. However, the poll time
register is controlled internally by microcode, so any
other microcode controlled operation will interrupt the
incrementing of the poll count register. For example,
when a receive packet is accepted by the PCnet-ISA II
controller, the device suspends execution of the
poll-time-incrementing microcode so that a receive
microcode routine may instead be executed.
Poll-time-incrementing code is resumed when the
receive operation has completely finished. Note, how-
ever, that following the completion of any receive or
transmit operation, a poll operation will always be performed. The poll time count register is ne ver reset. Note
that if a non-default is desired, then a strict sequence
of setting the INIT bit in CSR0, waiting for the IDON bit
in CSR0, then writing to CSR47, and then setting STRT
in CSR0 must be observed, otherwise the default value
will not be overwritten. See the CSR47 section for
details.
Setting the TDMD bit of CSR0 will cause the microcode
controller to exit the poll counting code and immediately perform a polling operation. If RDTE ownership
has not been previously established, then an RDTE
poll will be performed ahead of the TDTE poll.
Transmit Descriptor Table Entry (TDTE)
If, after a TDTE access, the PCnet-ISA II controller
finds that the OWN bit of that TDTE is not set, then the
PCnet-ISA II controller resumes the poll time count and
re-examines the same TDTE at the next expiration of
the poll time count.
If the OWN bit of the TDTE is set, but STP = 0, the
PCnet-ISA II controller will immediately request the bus
in order to reset the OWN bit of this descriptor; this condition would normally be found following a LCOL or
RETRY error that occurred in the middle of a transmit
packet chain of buffers. After resetting the OWN bit of
this descriptor, the PCnet-ISA II controller will again
immediately request the bus in order to access the next
TDTE location in the ring.
If the OWN bit is set and the buff er length is 0, the OWN
bit will be reset. In the LANCE the buffer length of 0 is
interpreted as a 4096-byte buffer. It is acceptable to
have a 0 length buffer on transmit with STP=1 or
and
STP=1
length buffer with STP = 0
If the OWN bit is set and the start of packet (STP) bit is
set, then microcode control proceeds to a routine that
will enable transmit data transfers to the FIFO.
If the transmit buffers are data chained (ENP = 0 in the
first buffer), then the PCnet-ISA II controller will look
ahead to the next transmit descriptor after it has performed at least one transmit data transfer from the first
buffer. More than one transmit data transfer ma y possibly take place, depending upon the state of the transmitter. The transmit descriptor look ahead reads TMD0
first and TMD1 second. The contents of TMD0 and
TMD1 will be stored in Next TX Descr iptor Address
(CSR32), Next TX Byte Count (CSR66) and Next TX
Status (CSR67) regardless of the state of the OWN bit.
This transmit descriptor lookahead operation is
performed only once.
If the PCnet-ISA II controller does not own the next
TDTE (i.e. the second TDTE for this packet), then it will
complete transmission of the current buffer and then
ENP = 1. It is not acceptable to have 0
and
ENP = 1.
Am79C961A59
PRELIMINARY
update the status of the current (first) TDTE with the
BUFF and UFLO bits being set. If DXSUFLO is 0 (bit 6
CSR3), then this will cause the transmitter to be disabled (CSR0, TXON = 0). The PCnet-ISA II controller
will have to be restarted to restore the transmit function.
The situation that matches this description implies that
the system has not been able to stay ahead of the
PCnet-ISA II controller in the transmit descriptor ring
and therefore, the condition is treated as a fatal error.
To avoid this situation, the system should always set
the transmit chain descriptor own bits in reverse order.
If the PCnet-ISA II controller does own the second
TDTE in a chain, it will gradually empty the contents of
the first buffer (as the bytes are needed b y the tr ansmit
operation), perform a single-cycle DMA transfer to
update the status (reset the OWN bit in TMD1) of the
first descriptor, and then it may perform one data DMA
access on the second buffer in the chain bef ore ex ecuting another lookahead operation. (i.e. a lookahead to
the third descriptor).
The PCnet-ISA II controller can queue up to two packets in the transmit FIFO. Call them packet “X” and
packet “Y”, where “Y” is after “X”. Assume that packet
“X” is currently being transmitted. Because the
PCnet-ISA II controller can perform lookahead data
transfer over an ENP, it is possible for the PCnet-ISA II
controller to update a TDTE in a buffer belonging to
packet “Y” while packet “X” is being transmitted if
packet “Y” uses data chaining. This operation will result
in non-sequential TDTE accesses as packet “X” completes transmission and the PCnet-ISA II controller
writes out its status, since packet “X”’s TDTE is before
the TDTE accessed as part of the lookahead data
transfer from packet “Y”.
This should not cause any problem for properly written
software which processes buffers in sequence, waiting
for ownership before proceeding.
If an error occurs in the transmission before all of the
bytes of the current buffer have been transferred, then
TMD2 and TMD1 of the current buffer will be written; in
that case, data transfers from the next buffer will not
commence. Instead, following the TMD2/TMD1 update ,
the PCnet-ISA II controller will go to the next transmit
packet, if any, skipping over the rest of the packet which
experienced an error, including chained buffers.
This is done by returning to the polling microcode
where it will immediately access the next descriptor
and find the condition OWN = 1 and STP = 0 as
described earlier. In that case, the PCnet-ISA II controller will reset the own bit for this descriptor and continue
in like manner until a descriptor with OWN = 0 (no more
transmit packets in the ring) or OWN = 1 and STP = 1
(the first buffer of a new packet) is reached.
At the end of any transmit operation, whether successful or with errors, and the completion of the descriptor
updates, the PCnet-ISA II controller will always perf orm
another poll operation. As described earlier, this poll
operation will begin with a check of the current RDTE,
unless the PCnet-ISA II controller already owns that
descriptor. Then the PCnet-ISA II controller will
proceed to polling the next TDTE. If the transmit
descriptor OWN bit has a zero value, then the
PCnet-ISA II controller will resume poll time count
incrementation. If the transmit descriptor OWN bit has
a value of ONE, then the PCnet-ISA II controller will
begin filling the FIFO with transmit data and initiate a
transmission. This end-of-operation poll avoids inserting poll time counts between successive transmit
packets.
Whenever the PCnet-ISA II controller completes a
transmit packet (either with or without error) and writes
the status information to the current descriptor, then the
TINT bit of CSR0 is set to indicate the completion of a
transmission. This causes an interrupt signal if the
IENA bit of CSR0 has been set and the TINTM bit of
CSR3 is reset.
Receive Descriptor Table Entry (RDTE)
If the PCnet-ISA II controller does not own both the current and the next Receive Descriptor Table Entry, then
the PCnet-ISA II controller will continue to poll according to the polling sequence described above. If the
receive descriptor ring length is 1, there is no next
descriptor, and no look ahead poll will take place.
If a poll operation has revealed that the current and the
next RDTE belongs to the PCnet-ISA II controller , then
additional poll accesses are not necessary. Future poll
operations will not include RDTE accesses as long as
the PCnet-ISA II controller retains ownership to the current and the next RDTE.
When receive activity is present on the channel, the
PCnet-ISA II controller waits for the complete address
of the message to arrive. It then decides whether to
accept or reject the packet based on all active addressing schemes. If the packet is accepted the PCnet-ISA
II controller checks the current receive buffer status
register CRST (CSR40) to determine the ownership of
the current buffer.
If ownership is lacking, then the PCnet-ISA II controller
will immediately perform a (last ditch) poll of the current
RDTE. If ownership is still denied, then the PCnet-ISA
II controller has no buffer in which to store the incoming
message. The MISS bit will be set in CSR0 and an
interrupt will be generated if IENA = 1 (CSR0) and
MISSM = 0 (CSR3). Another poll of the current RDTE
will not occur until the packet has finished.
If the PCnet-ISA II controller sees that the last poll
(either a normal poll or the last-ditch effort described in
the above paragraph) of the current RDTE sho ws valid
ownership, then it proceeds to a poll of the ne xt RDTE.
60Am79C961A
PRELIMINARY
Following this poll, and regardless of the outcome of
this poll, transfers of receive data from the FIFO may
begin.
Regardless of ownership of the second receive
descriptor, the PCnet-ISA II controller will continue to
perform receive data DMA transfers to the first buffer,
using burst-cycle DMA transfers. If the packet length
exceeds the length of the first buffer, and the
PCnet-ISA II controller does not own the second buffer,
ownership of the current descriptor will be passed back
to the system by writing a zero to the OWN bit of RMD1
and status will be written indicating buffer (BUFF = 1)
and possibly overflow (OFLO = 1) errors.
If the packet length exceeds the length of the first (current) buffer, and the PCnet-ISA II controller does own
the second (next) buff er, o wnership will be passed back
to the system by writing a zero to the OWN bit of RMD1
when the first buffer is full. Receiv e data transfers to the
second buffer may occur before the PCnet-ISA II controller proceeds to look ahead to the ownership of the
third buffer. Such action will depend upon the state of
the FIFO when the status has been updated on the first
descriptor. In any case, lookahead will be performed to
the third buffer and the infor mation gathered will be
stored in the chip, regardless of the state of the ownership bit. As in the transmit flow, lookahead operations
are performed only once.
This activity continues until the PCnet-ISA II controller
recognizes the completion of the packet (the last b yte of
this receive message has been removed from the FIFO).
The PCnet-ISA II controller will subsequently update the
current RDTE status with the end of packet (ENP) indication set, write the message byte count (MCNT) of the
complete packet into RMD2 and overwrite the “current”
entries in the CSRs with the “next” entries.
Media Access Control
The Media Access Control engine incorporates the
essential protocol requirements for operation of a compliant Ethernet/802.3 node, and provides the interface
between the FIFO sub-system and the Manchester
Encoder/Decoder (MENDEC).
This section describes operation of the MAC engine
when operating in Half Duplex mode. When in Half
Duplex mode, the MAC engine is fully compliant to Section 4 of ISO/IEC 8802-3 (ANSI/IEEE Standard 1990
Second Edition) and ANSI/IEEE 802.3 (1985). When
operating in Full Duplex mode, the MA C engine behavior
changes as described in the Full Duplex Operation section.
The MAC engine provides programmable enhanced
features designed to minimize host supervision and pre
or post-message processing. These features include
the ability to disable retries after a collision, dynamic
FCS generation on a packet-by-pac ket basis, and auto-
matic pad field insertion and deletion to enforce
minimum frame size attributes.
The two primary attributes of the MAC engine are:
■ Transmit and receive message data encapsulation
— Framing (frame boundary delimitation, frame
synchronization)
— Addressing (source and destination address
handling)
— Error detection (physical medium transmission
errors)
■ Media access management
— Medium allocation (collision avoidance)
— Contention resolution (collision handling)
T ransmit and Receive Message Data Encapsulation
The MAC engine provides minimum frame size
enforcement for transmit and receive packets. When
APAD_XMT = 1 (bit 11 in CSR4), transmit messages
will be padded with sufficient bytes (containing 00h) to
ensure that the receiving station will observe an information field (destination address, source address,
length/type, data and FCS) of 64-bytes. When
ASTRP_RCV = 1 (bit 10 in CSR4), the receiver will
automatically strip pad bytes from the received message by observing the value in the length field, and
stripping excess bytes if this value is below the minimum data size (46 bytes). Both features can be independently over-ridden to allow illegally short (less than
64 bytes of packet data) messages to be transmitted
and/or received. The use of these features reduce bus
bandwidth usage because the pad bytes are not transferred to or from host memory.
The MAC engine will autonomously handle the construction of the transmit frame. Once the Transmit FIFO
has been filled to the predetermined threshold (set by
XMTSP in CSR80), and providing access to the channel is currently permitted, the MAC engine will commence the 7-byte preamble sequence (10101010b,
where first bit transmitted is a 1). The MAC engine will
subsequently append the Start Frame Delimiter (SFD)
byte (10101011b) followed by the serialized data from
the Transmit FIFO. Once the data has been completed,
the MAC engine will append the FCS (most significant
bit first) which was computed on the entire data portion
of the message.
Note that the user is responsible for the correct ordering and content in each of the fields in the frame,
including the destination address, source address,
length/type and packet data.
The receive section of the MAC engine will detect an
incoming preamble sequence and lock to the encoded
Am79C961A61
PRELIMINARY
clock. The internal MENDEC will decode the serial bit
stream and present this to the MAC engine. The MAC
will discard the first 8 bits of information before searching for the SFD sequence. Once the SFD is detected,
all subsequent bits are treated as part of the frame. The
MAC engine will inspect the length field to ensure minimum frame size, strip unnecessary pad characters (if
enabled), and pass the remaining bytes through the
Receive FIFO to the host. If pad stripping is performed,
the MAC engine will also strip the received FCS bytes,
although the normal FCS computation and checking
will occur. Note that apart from pad stripping, the frame
will be passed unmodified to the host. If the length field
has a value of 46 or greater, the MAC engine will not
attempt to validate the length against the number of
bytes contained in the message.
If the frame terminates or suffers a collision before
64 bytes of information (after SFD) have been
received, the MAC engine will automatically delete the
frame from the Receive FIFO, without host
intervention.
Addressing (source and destination address
handling)
The first 6 bytes of information after SFD will be interpreted as the destination address field. The MAC
engine provides facilities for physical, logical, and
broadcast address reception. In addition, multiple
physical addresses can be constr ucted (perfect
address filtering) using external logic in conjunction
with the EADI interface.
Error detection (physical medium transmission
errors)
The MAC engine provides several facilities which
report and recover from errors on the medium. In addition, the network is protected from gross errors due to
inability of the host to keep pace with the MAC engine
activity.
On completion of transmission, the following transmit
status is available in the appropriate TMD and CSR
areas:
■ The exact number of transmission retry attempts
(ONE, MORE, or RTRY).
■ Whether the MAC engine had to Def er (DEF) due to
channel activity.
■ Loss of Carrier, indicating that there was an interruption in the ability of the MAC engine to monitor its
own transmission. Repeated LCAR errors indicate
a potentially faulty transceiver or network
connection.
■ Late Collision (LCOL) indicates that the transmission suffered a collision after the slot time. This is
indicative of a badly configured network. Late colli-
sions should not occur in a normal operating network.
■ Collision Error (CERR) indicates that the transceiver did not respond with an SQE Test message
within the predetermined time after a transmission
completed. This may be due to a failed transceiver,
disconnected or faulty transceiver drop cab le, or the
fact the transceiver does not support this feature (or
the feature is disabled).
In addition to the reporting of network errors, the MAC
engine will also attempt to prevent the creation of any
network error due to the inability of the host to service
the MAC engine. Dur ing transmission, if the host fails
to keep the Transmit FIFO filled sufficiently, causing an
underflow , the MAC engine will guarantee the message
is either sent as a runt packet (which will be deleted by
the receiving station) or has an invalid FCS (which will
also cause the receiver to reject the message).
The status of each receive message is available in the
appropriate RMD and CSR areas. FCS and Framing
errors (FRAM) are reported, although the received
frame is still passed to the host. The FRAM error will
only be reported if an FCS error is detected and there
are a non-integral number of bits in the message. The
MAC engine will ignore up to seven additional bits at
the end of a message (dribbling bits), which can occur
under normal network operating conditions. The reception of eight additional bits will cause the MAC engine
to de-serialize the entire byte, and will result in the
received message and FCS being modified.
The PCnet-ISA II controller can handle up to 7 dribbling
bits when a received packet terminates. During the
reception, the CRC is generated on every serial bit
(including the dribbling bits) coming from the cable,
although the internally saved CRC value is only
updated on the eighth bit (on each byte boundary). The
framing error is reported to the user as follows:
1. If the number of the dribbling bits are 1 to 7 and
there is no CRC error, then there is no F raming error
(FRAM = 0).
2. If the number of the dribbling bits are less than 8
and there is a CRC error, then there is also a
Framing error (FRAM = 1).
3. If the number of dribbling bits = 0, then there is no
Framing error. There may or may not be a CRC
(FCS) error.
Counters are provided to report the Receive Collision
Count and Runt Packet Count used for network statistics and utilization calculations.
Note that if the MAC engine detects a received packet
which has a 00b pattern in the preamble (after the first
8 bits, which are ignored), the entire packet will be
ignored. The MAC engine will wait for the network to go
inactive before attempting to receive the next packet.
62Am79C961A
PRELIMINARY
Media Access Management
The basic requirement for all stations on the network is
to provide fairness of channel allocation. The 802.3/
Ethernet protocol defines a media access mechanism
which permits all stations to access the channel with
equality. Any node can attempt to contend for the channel by waiting for a predetermined time (Inter Packet
Gap interval) after the last activity, before transmitting
on the medium. The channel is a multidrop
communications medium (with various topological configurations permitted) which allows a single station to
transmit and all other stations to receive. If two nodes
simultaneously contend for the channel, their signals
will interact, causing loss of data (defined as a collision).
It is the responsibility of the MAC to attempt to av oid and
recover from a collision, to guarantee data integrity for
the end-to-end transmission to the receiving station.
Medium Allocation (collision avoidance)
The IEEE 802.3 Standard (ISO/IEC 8802-3 1990)
requires that the CSMA/CD MAC monitor the medium
traffic by looking for carrier activity. When carrier is
detected the medium is considered busy, and the MAC
should defer to the existing message.
The IEEE 802.3 Standard also allows optional two part
deferral after a receive message.
See ANSI/IEEE Std 802.3-1990 Edition, 4.2.3.2.1:
“Note: It is possible for the PLS carrier sense
indication to fail to be asserted during a collision on the media. If the deference process
simply times the interpacket gap based on this
indication it is possible for a short interFrame
gap to be generated, leading to a potential reception failure of a subsequent frame. To enhance system robustness the following optional measures, as specified in 4.2.8, are recommended when InterFrameSpacingPart1 is
other than zero:
(1) Upon completing a transmission, start timing
the interpacket gap, as soon as transmitting
and carrier Sense are both false.
(2) When timing an interpacket gap following re-
ception, reset the interpacket gap timing if carrier Sense becomes true during the first 2/3 of
the interpacket gap timing interval. During the
final 1/3 of the interval the timer shall not be reset to ensure fair access to the medium. An initial period shorter than 2/3 of the interval is
permissible including zero.”
The MAC engine implements the optional receive two
part deferral algorithm, with a first part
inter-frame-spacing time of 6.0 µs. The second part of
the inter-frame-spacing interval is therefore 3.6 µs.
The PCnet-ISA II controller will perform the two-part
deferral algorithm as specified in Section 4.2.8 (Process Deference). The Inter Packet Gap (IPG) timer will
start timing the 9.6 µs InterFrameSpacing after the
receive carrier is de-asserted. During the first part
deferral (InterFrameSpacingPart1 – IFS1) the
PCnet-ISA II controller will defer any pending transmit
frame and respond to the receive message. The IPG
counter will be reset to zero continuously until the carrier de-asserts, at which point the IPG counter will
resume the 9.6 µs count once again. Once the IFS1
period of 6.0 µs has elapsed, the PCnet-ISA II controller will begin timing the second part deferral
(InterFrameSpacingPart2 – IFS2) of 3.6 µs. Once IFS1
has completed, and IFS2 has commenced, the
PCnet-ISA II controller will not defer to a receive pac ket
if a transmit packet is pending. This means that the
PCnet-ISA II controller will not attempt to receive the
receive packet, since it will start to transmit, and generate a collision at 9.6 µs. The PCnet-ISA II controller will
guarantee to complete the preamble (64-bit) and jam
(32-bit) sequence before ceasing transmission and
invoking the random backoff algorithm.
In addition, transmit two part deferral is implemented
as an option which can be disabled using the
DXMT2PD bit (CSR3). Two-part deferral after transmission is useful for ensuring that severe IPG shrinkage
cannot occur in specific circumstances, causing a
transmit message to follow a receive message so
closely as to make them indistinguishable.
During the time period immediately after a transmission has been completed, the external transceiver (in
the case of a standard AUI connected device), should
generate the SQE Test message (a nominal 10 MHz
burst of 5-15 bit times duration) on the CI± pair (within
0.6 µs – 1.6 µs after the transmission ceases). During
the time period in which the SQE Test message is
expected the PCnet-ISA II controller will not respond to
receive carrier sense.
See ANSI/IEEE Std 802.3-1990 Edition, 7.2.4.6 (1):
“At the conclusion of the output function, the
DTE opens a time window during which it expects to see the
signal_quality_erro
r signal asserted on the Control In circuit. The time window begins when the CARRIER_STATUS becomes CARRIER_OFF. If execution of the output function does not cause CARRIER_ON to
occur, no SQE test occurs in the DTE. The duration of the window shall be at least 4.0 µs but
no more than 8.0 µs. During the time window
the Carrier Sense Function is inhibited.”
The PCnet-ISA II controller implements a carrier sense
“blinding” period within 0 – 4.0 µs from de-assertion of
carrier sense after transmission. This eff ectiv ely means
that when transmit two part deferral is enabled
(DXMT2PD is cleared) the IFS1 time is from 4 µs to 6
µs after a transmission. However, since IPG shrinkage
below 4 µs will rarely be encountered on a correctly
configured network, and since the fragment size will be
Am79C961A63
PRELIMINARY
larger than the 4 µs blinding window, then the IPG
counter will be reset by a worst case IPG shrinkage/
fragment scenario and the PCnet-ISA II controller will
defer its transmission. In addition, the PCnet-ISA II
controller will not restart the “blinding” period if carrier
is detected within the 4.0 µs – 6.0 µs IFS1 period, but
will commence timing of the entire IFS1 period.
Contention resolution (collision handling)
Collision detection is performed and reported to the
MAC engine by the integrated Manchester Encoder/
Decoder (MENDEC).
If a collision is detected before the complete preamble/
SFD sequence has been transmitted, the MAC Engine
will complete the preamble/SFD before appending the
jam sequence. If a collision is detected after the preamble/SFD has been completed, but prior to 512 bits
being transmitted, the MAC Engine will abort the transmission, and append the jam sequence immediately.
The jam sequence is a 32-bit all zeroes pattern.
The MAC Engine will attempt to transmit a frame a total
of 16 times (initial attempt plus 15 retries) due to normal collisions (those within the slot time). Detection of
collision will cause the transmission to be
re-scheduled, dependent on the backoff time that the
MAC Engine computes. If a single retr y was required,
the ONE bit will be set in the Transmit Frame Status
(TMD1 in the Transmit Descr iptor Ring). If more than
one retry was required, the MORE bit will be set. If all
16 attempts experienced collisions, the RTRY bit (in
TMD2) will be set (ONE and MORE will be clear), and
the transmit message will be flushed from the FIFO. If
retries have been disabled by setting the DRTY bit in
the MODE register (CSR15), the MAC Engine will
abandon transmission of the frame on detection of the
first collision. In this case, only the RTRY bit will be set
and the transmit message will be flushed from the
FIFO.
If a collision is detected after 512 bit times have been
transmitted, the collision is termed a late collision. The
MAC Engine will abort the transmission, append the
jam sequence, and set the LCOL bit. No retry attempt
will be scheduled on detection of a late collision, and
the FIFO will be flushed.
The IEEE 802.3 Standard requires use of a “truncated
binary exponential backoff” algorithm which provides a
controlled pseudo-random mechanism to enforce the
collision backoff interval, before re-transmission is
attempted.
See ANSI/IEEE Std 802.3-1990 Edition, 4.2.3.2.5:
“At the end of enforcing a collision (jamming),
the CSMA/CD sublayer delays before attempting to re-transmit the frame. The delay is an integer multiple of slot Time. The number of slot
times to delay before the nth re-transmission
attempt is chosen as a uniformly distributed
random integer r in the range:
0 ≤ r < 2k, where k = min (n,10).”
The PCnet-ISA II controller provides an alternative
algorithm, which suspends the counting of the slot
time/IPG during the time that receive carrier sense is
detected. This algorithm aids in networ ks where large
numbers of nodes are present, and numerous nodes
can be in collision. The algorithm effectively accelerates the increase in the backoff time in busy networks,
and allows nodes not involv ed in the collision to access
the channel while the colliding nodes await a reduction
in channel activity. Once channel activity is reduced,
the nodes resolving the collision time out their slot time
counters as normal.
Manchester Encoder/Decoder (MENDEC)
The integrated Manchester Encoder/Decoder provides
the PLS (Physical Layer Signaling) functions required
for a fully compliant IEEE 802.3 station. The MENDEC
provides the encoding function for data to be transmitted on the network using the high accuracy on-board
oscillator, driven b y either the crystal oscillator or an external CMOS-level compatible clock. The MENDEC
also provides the decoding function from data received
from the network. The MENDEC contains a Power On
Reset (POR) circuit, which ensures that all analog portions of the PCnet-ISA II controller are forced into their
correct state during power-up, and pre vents erroneous
data transmission and/or reception during this time.
External Crystal Characteristics
When using a crystal to drive the oscillator, the crystal
specification shown in the specification table may be
used to ensure less than ±0.5 ns jitter at DO±.
External Crystal Characteristics
ParameterMin Nom Max Unit
1. Parallel Resonant Frequency20MHz
2. Resonant Frequency Error
(CL = 20 pF)
3.Change in Resonant
Frequency With Respect
T o Temperature
(0° – 70° C; CL = 20 pF)*
4. Crystal Capacitance20pF
5. Motional Crystal Capacitance
(C1)
6. Series Resistance25Ω
7. Shunt Capacitance7pF
8. Drive LevelTBD mW
Requires trimming crystal spec; no trim is 50 ppm total
–50+50 PPM
–40+40 PPM
0.022pF
64Am79C961A
PRELIMINARY
External Clock Drive Characteristics
When driving the oscillator from an external clock
source, XTAL2 must be left floating (unconnected). An
external clock having the f ollowing characteristics must
be used to ensure less than ±0.5 ns jitter at DO±.
Clock Frequency: 20 MHz ±0.01%
Rise/Fall Time (tR/tF): < 6 ns from 0.5 V to VDD–0.5
XTAL1 HIGH/LOW Time
(tHIGH/tLOW):
XTAL1 Falling Edge to
Falling Edge Jitter:
40 – 60% duty cycle
< ±0.2 ns at 2.5 V input (VDD/2)
MENDEC T ransmit Path
The transmit section encodes separate clock and NRZ
data input signals into a standard Manchester encoded
serial bit stream. The transmit outputs (DO±) are
designed to operate into terminated transmission lines.
When operating into a 78 Ω terminated transmission
line, the transmit signaling meets the required output
levels and skew for Cheapernet, Ethernet, and
IEEE-802.3.
Transmitter Timing and Operation
A 20 MHz fundamental-mode crystal oscillator provides the basic timing reference for the MENDEC portion of the PCnet-ISA II controller. The crystal input is
divided by two to create the internal transmit clock reference. Both clocks are fed into the Manchester
Encoder to generate the transitions in the encoded
data stream. The inter nal transmit clock is used by the
MENDEC to internally synchronize the Internal Transmit Data (ITXDAT) from the controller and Inter nal
Transmit Enable (ITXEN). The internal transmit clock is
also used as a stable bit-rate clock by the receive section of the MENDEC and controller.
The oscillator requires an external 0.005% crystal, or
an external 0.01% CMOS-level input as a reference.
The accuracy requirements, if an external crystal is
used, are tighter because allowance for the on-chip
oscillator must be made to deliver a final accuracy of
0.01%.
Transmission is enabled by the controller. As long as
the ITXEN request remains active, the serial output of
the controller will be Manchester encoded and appear
at DO±. When the internal request is dropped by the
controller, the differential transmit outputs go to one of
two idle states, dependent on TSEL in the Mode
Register (CSR15, bit 9):
The idle state of DO± yields “zero”
TSEL LOW:
TSEL HIGH:
differential to operate transformer-coupled
loads
In this idle state, DO+ is positive with respect
to DO– (logical HIGH).
Receive Path
The principal functions of the receiver are to signal the
PCnet-ISA II controller that there is information on the
receive pair , and to separ ate the incoming Manchester
encoded data stream into clock and NRZ data.
The receiver section (see Receiver Block Diagram)
consists of two parallel paths. The receive data path is
a zero threshold, wide bandwidth line receiver. The
carrier path is an offset threshold bandpass detecting
line receiver. Both receivers share common bias
networks to allow operation over a wide input common
mode range.
Input Signal Conditioning
Transient noise pulses at the input data stream are
rejected by the Noise Rejection Filter. Pulse width
rejection is proportional to transmit data rate which is
fixed at 10 MHz for Ethernet systems but which could
be different for proprietary networks. DC inputs more
negative than minus 100 mV are also suppressed.
The Carrier Detection circuitry detects the presence of
an incoming data packet by discerning and rejecting
noise from expected Manchester data, and controls the
stop and start of the phase-lock loop during clock
acquisition. Clock acquisition requires a valid
Manchester bit pattern of 1010b to lock onto the incoming message.
When input amplitude and pulse width conditions are
met at DI±, a clock acquisition cycle is initiated.
Clock Acquisition
When there is no activity at DI± (receiver is idle), the
receive oscillator is phase-locked to STDCLK. The first
negative clock transition (bit cell center of first valid
Manchester “0") after clock acquisition begins interrupts the receive oscillator. The oscillator is then
restarted at the second Manchester “0" (bit time 4) and
is phase-locked to it. As a result, the MENDEC
acquires the clock from the incoming Manchester bit
pattern in 4 bit times with a “1010" Manchester bit pattern.
The internal receiver clock, IRXCLK, and the internal
received data, IRXDAT, are enabled 1/4 bit time after
clock acquisition in bit cell 5. IRXD AT is at a HIGH state
when the receiver is idle (no IRXCLK). IRXDAT however, is undefined when clock is acquired and may
remain HIGH or change to LOW state whenever IRXCLK is enabled. At 1/4 bit time through bit cell 5, the
controller portion of the PCnet-ISA II controller sees
the first IRXCLK transition. This also strobes in the
incoming fifth bit to the MENDEC as Manchester “1".
IRXDAT may make a transition after the IRXCLK rising
edge in bit cell 5, but its state is still undefined. The
Manchester “1" at bit 5 is clocked to IRXDAT output at
1/4 bit time in bit cell 6.
Am79C961A65
PRELIMINARY
PLL T racking
After clock acquisition, the phase-locked clock is compared to the incoming transition at the bit cell center
(BCC) and the resulting phase error is applied to a correction circuit. This circuit ensures that the
DI±
*Internal signal
Data
Receiver
Noise
Reject
Filter
Receiver Block Diagram
Carrier Tracking and End of Message
The carrier detection circuit monitors the DI± inputs
after IRXCRS is asserted for an end of message.
IRXCRS de-asserts 1 to 2 bit times after the last positive transition on the incoming message. This initiates
the end of reception cycle. The time delay from the last
rising edge of the message to IRXCRS deassert allows
the last bit to be strobed by IRXCLK and transferred to
the controller section, but prevents any extra bit(s) at
the end of message. When IRXCRS de-asserts an
IRXCRS hold off timer inhibits IRXCRS assertion for at
least 2 bit times.
Data Decoding
The data receiver is a comparator with clocked output
to minimize noise sensitivity to the DI± inputs. Input
error is less than ±35 mV to minimize sensitivity to input
rise and fall time. IRXCLK strobes the data receiver
output at 1/4 bit time to determine the value of the
Manchester bit, and clocks the data out on IRXDAT on
the following IRXCLK. The data receiver also
generates the signal used for phase detector comparison to the internal MENDEC voltage controlled
oscillator (VCO).
Differential Input Terminations
The differential input for the Manchester data (DI±)
should be externally terminated by two 40.2 Ω±1%
resistors and one optional common-mode bypass
capacitor, as shown in the Diff erential Input Termination
diagram below. The differential input impedance, Z
IDF,
and the common-mode input impedance, ZICM, are
phase-locked clock remains locked on the received
signal. Individual bit cell phase corrections of the
Voltage Controlled Oscillator (VCO) are limited to 10%
of the phase difference between BCC and phaselocked clock.
Manchester
Decoder
Carrier
Detect
Circuit
IRXDAT*
IRXCLK*
IRXCRS*
19364A-12
specified so that the Ethernet specification for cable
termination impedance is met using standard 1%
resistor terminators. If SIP devices are used, 39 Ω is
the nearest usable equivalent value. The CI± differential inputs are terminated in exactly the same way as
the DI± pair.
AUI Isolation
0.01 µF
to 0.1 µF
Transformer
19364A-13
DI+
PCnet-ISA II
DI
40.2 Ω40.2 Ω
Differential Input Termination
Collision Detection
A MAU detects the collision condition on the network
and generates a differential signal at the CI± inputs.
This collision signal passes through an input stage
which detects signal levels and pulse duration. When
the signal is detected by the MENDEC it sets the internal collision signal, ICLSN, HIGH. The condition continues for approximately 1.5 bit times after the last
LOW-to-HIGH transition on CI±.
66Am79C961A
PRELIMINARY
Jitter T olerance Definition
The MENDEC utilizes a clock capture circuit to align its
internal data strobe with an incoming bit stream. The
clock acquisition circuitry requires four valid bits with
the values 1010b. Clock is phase-locked to the negative transition at the bit cell center of the second “0" in
the pattern.
Since data is strobed at 1/4 bit time, Manchester transitions which shift from their nominal placement
through 1/4 bit time will result in improperly decoded
data. With this as the criteria for an error, a definition of
“Jitter Handling” is:
The peak deviation approaching or crossing
1/4 bit cell position from nominal input transition, for which the MENDEC section will
properly decode data.
Attachment Unit Interface (AUI)
The AUI is the PLS (Physical Layer Signaling) to PMA
(Physical Medium Attachment) interface which connects the DTE to a MAU. The differential interface provided by the PCnet-ISA II controller is fully compliant
with Section 7 of ISO 8802-3 (ANSI/IEEE 802.3).
After the PCnet-ISA II controller initiates a transmission, it will expect to see data “looped-bac k” on the DI±
pair (when the AUI port is selected). This will internally
generate a “carrier sense”, indicating that the integrity
of the data path to and from the MAU is intact, and that
the MAU is operating correctly. This “carrier sense” signal must be asserted within sometime before end of
transmission. If “carrier sense” does not become active
in response to the data transmission, or becomes inactive before the end of transmission, the loss of carrier
(LCAR) error bit will be set in the Transmit Descriptor
Ring (TMD3, bit 11) after the packet has been
transmitted.
Twisted Pair Transceiver (T-MAU)
This section describes operation of the T-MAU when
operating in the Half Duplex mode. When in Half
Duplex mode, the T-MAU implements the Medium
Attachment Unit (MAU) functions for the Twisted Pair
Medium as specified by the supplement to IEEE 802.3
standard (Type 10BASE-T). When operating in Full
Duplex mode, the MAC engine behavior changes as
described in the Full Duplex Operation section. The
T-MAU provides twisted pair driver and receiver circuits, including on-board transmit digital predistortion
and receiver squelch, and a number of additional features including Link Status indication, Automatic
Twisted Pair Receive Polarity Detection/Correction and
Indication, Receive Carrier Sense, Transmit Active and
Collision Present indication.
Twisted Pair Transmit Function
The differential driver circuitry in the TXD± and TXP±
pins provides the necessary electrical driving capability
and the pre-distortion control for transmitting signals
over maximum length Twisted Pair cable, as specified
by the 10BASE-T supplement to the IEEE 802.3 Standard. The transmit function for data output meets the
propagation delays and jitter specified by the standard.
Twisted Pair Receive Function
The receiver complies with the receiver specifications
of the IEEE 802.3 10BASE-T Standard, including noise
immunity and received signal rejection criteria (‘Smart
Squelch’). Signals meeting these criteria appearing at
the RXD± differential input pair are routed to the
MENDEC. The receiver function meets the propagation
delays and jitter requirements specified by the standard. The receiv er squelch lev el drops to half its threshold value after unsquelch to allow reception of
minimum amplitude signals and to offset carrier fade in
the event of worst case signal attenuation conditions.
Note that the 10BASE-T Standard defines the receive
input amplitude at the external Media Dependent Interface (MDI). Filter and transformer loss are not specified. The T-MAU receiver squelch levels are designed
to account for a 1 dB insertion loss at 10 MHz for the
type of receive filters and transformers usually used.
Normal 10BASE-T compatible receive thresholds are
invoked when the LR T bit (CSR15, bit 9) is LO W. When
the LRT bit is set, the Low Receive Threshold option is
invoked, and the sensitivity of the T-MAU receiver is
increased. Increasing T-MAU sensitivity allows the use
of lines longer than the 100 m target distance of standard 10BASE-T (assuming typical 24 AWG cable).
Increased receiver sensitivity compensates for the
increased signal attenuation caused by the additional
cable distance.
However, making the receiver more sensitive means
that it is also more susceptible to extraneous noise , primarily caused by coupling from co-resident services
(crosstalk). For this reason, end users may wish to
invoke the Low Receive Threshold option on 4-pair
cable only. Multi-pair cables within the same outer
sheath have lower crosstalk atten uation, and may allow
noise emitted from adjacent pairs to couple into the
receive pair, and be of sufficient amplitude to falsely
unsquelch the T-MAU.
Link Test Function
The link test function is implemented as specified by
10BASE-T standard. During periods of transmit pair
inactivity ,’Link beat pulses’ will be periodically sent over
the twisted pair medium to constantly monitor medium
integrity.
Am79C961A67
PRELIMINARY
When the link test function is enabled (DLNKTST bit in
CSR15 is cleared), the absence of link beat pulses and
receive data on the RXD± pair will cause the TMAU to
go into the Link Fail state. In the Link Fail state, data
transmission, data reception, data loopback and the
collision detection functions are disabled and remain
disabled until valid data or greater than 5 consecutive
link pulses appear on the RXD± pair. During Link Fail,
the Link Status (LNKST indicated by LED0) signal is
inactive. When the link is identified as functional, the
LNKST signal is asserted, and LED0
output will be
activated. Upon power up or assertion of the RESET
pin, the T-MAU will be forced into the Link Fail state.
Reading the RESET register of the PCnet-ISA+ (software RESET) has no effect on the T-MAU
In order to inter-operate with systems which do not
implement Link Test, this function can be disabled by
setting the DLNKTST bit. With Link Test disabled, the
Data Driver, Receiver and Loopback functions as well
as Collision Detection remain enabled irrespective of
the presence or absence of data or link pulses on the
RXD± pair. Link Test pulses continue to be sent regardless of the state of the DLNKTST bit.
Polarity Detection and Reversal
The T-MAU receive function includes the ability to
invert the polarity of the signals appearing at the RXD±
pair if the polarity of the received signal is reversed
(such as in the case of a wiring error). This feature
allows data packets received from a reverse wired
RXD± input pair to be corrected in the T-MAU prior to
transfer to the MENDEC. The polarity detection function is activated following reset or Link Fail, and will
reverse the receive polarity based on both the polarity
of any previous link beat pulses and the polarity of subsequent packets with a valid End Transmit Delimiter
(ETD).
When in the Link Fail state, the T-MAU will recognize
link beat pulses of either positive or negative polarity.
Exit from the Link Fail state occurs at the reception of
5 – 6 consecutive link beat pulses of identical polarity.
On entry to the Link Pass state, the polarity of the last
5 link beat pulses is used to determine the initial
receive polarity configuration and the receiver is
reconfigured to subsequently recognize only link beat
pulses of the previously recognized polarity.
Positiv e link beat pulses are defined as transmitted signal with a positive amplitude greater than 585 mV with
a pulse width of 60 ns – 200 ns. This positive excursion
may be follo wed by a negative e xcursion. This definition
is consistent with the expected received signal at a correctly wired receiver, when a link beat pulse, which fits
the template of Figure 14-12 of the 10BASE-T Standard, is generated at a transmitter and passed through
100 m of twisted pair cable.
Negative link beat pulses are defined as transmitted
signals with a negative amplitude greater than 585 mV
with a pulse width of 60 ns – 200 ns. This negative
excursion may be f ollowed b y a positiv e excursion. This
definition is consistent with the expected received signal at a reverse wired receiver, when a link beat pulse
which fits the template of Figure 14-12 in the
10BASE-T Standard is generated at a transmitter and
passed through 100 m of twisted pair cable.
The polarity detection/correction algorithm will remain
“armed” until two consecutive packets with valid ETD of
identical polarity are detected. When “armed,” the
receiver is capable of changing the initial or previous
polarity configuration according to the detected ETD
polarity.
On receipt of the first packet with valid ETD following
reset or link fail, the T-MAU will use the inferred polarity
information to configure its RXD± input, regardless of
its previous state. On receipt of a second packet with a
valid ETD with correct polarity, the detection/correction
algorithm will “lock-in” the received polarity. If the second (or subsequent) packet is not detected as confirming the previous polarity decision, the most recently
detected ETD polarity will be used as the default. Note
that packets with invalid ETD have no effect on updating the previous polarity decision. Once two consecutive packets with valid ETD have been received, the
T-MAU will lock the correction algorithm until either a
Link Fail condition occurs or RESET is asserted.
During polarity reversal, an internal POL signal will be
active. Dur ing normal polarity conditions, this internal
POL signal is inactive. The state of this signal can be
read by software and/or displayed by LED when
enabled by the LED control bits in the ISA Bus Configuration Registers (ISACSR5, 6, 7).
Twisted Pair Interface Status
Three internal signals (XMT, RCV and COL) indicate
whether the T-MAU is transmitting, receiving, or in a
collision state. These signals are internal signals and
the behavior of the LED outputs depends on how the
LED output circuitry is programmed.
The T-MAU will power up in the Link Fail state and the
normal algorithm will apply to allow it to enter the Link
Pass state. In the Link Pass state, transmit or receive
activity will be indicated by assertion of RCV signal
going active. If T-MAU is selected using the PORTSEL
bits in CSR15, when moving from AUI to T-MAU selection, the T-MAU will be forced into the Link Fail state.
In the Link Fail state, XMT, RCV and COL are inactive.
Collision Detect Function
Activity on both twisted pair signals RXD± and TXD±
constitutes a collision, thereby causing the COL signal
to be asserted. (COL is used by the LED control circuits) COL will remain asserted until one of the two col-
68Am79C961A
PRELIMINARY
liding signals changes from active to idle. COL stays
active for 2 bit times at the end of a collision.
Signal Quality Error (SQE) Test
(Heartbeat) Function
The SQE function is disabled when the 10BASE-T port
is selected and in Link Fail state.
Jabber Function
The Jabber function inhibits the twisted pair transmit
function of the T-MAU if the TXD± circuit is activ e f or an
excessive period (20 ms–150 ms). This prevents any
one node from disrupting the network due to a
‘stuck-on’ or f aulty transmitter. If this maximum transmit
time is exceeded, the T-MAU transmitter circuitry is disabled, the JAB bit is set (CSR4, bit 1), and the COL signal asserted. Once the transmit data stream to the
T-MAU is removed, an “unjab” time of 250 ms – 750 ms
will elapse before the T-MAU deasserts COL and
re-enables the transmit circuitry.
Power Down
The T-MAU circuitry can be made to go into low power
mode. This feature is useful in battery powered or low
duty cycle systems. The T-MAU will go into power down
mode when RESET is active, coma mode is active, or
the T-MAU is not selected. Refer to the Power Down
Mode section for a description of the various power
down modes.
Any of the three conditions listed above resets the
internal logic of the T-MAU and places the device into
power down mode. In this mode, the Twisted Pair driver
pins (TXD±,TXP±) are asserted LOW, and the internal
T-MAU status signals (LNKST, RCVPOL, XMT, RCV
and COLLISION) are inactive.
Once the SLEEP
forced into the Link Fail state. The T-MAU will move to
the Link Pass state only after 5–6 link beat pulses and/
or a single received message is detected on the RXD±
pair.
In Snooze mode, the T-MAU receive circuitry will
remain enabled even while the SLEEP pin is driven
LOW.
The T-MAU circuitry will always go into power down
mode if RESET is asserted, coma is enabled, or the
T-MAU is not selected.
pin is deasserted, the T-MAU will be
Full Duplex Operation
The PCnet-ISA II supports Full Duplex operation on the
10BASE-T, AUI, and GPSI ports. Full Duplex oper ation
allows simultaneous transmit and receive activity on
the TXD± and RXD± pairs of the 10BASE-T port, the
DO± and DI± pairs of the AUI port, and the TXDAT and
RXDAT pins of the GPSI port. It is enabled by the FDEN
and AUIFD bits located in ISA CSR9. When operating in
the Full Duplex mode, the following changes to device
operation are made:
Bus Interface/Buffer Management Unit changes:
1. The first 64 bytes of every transmit frame are not
preserved in the transmit FIFO during transmission
of the first 512 bits transmitted on the network, as
described in the Transmit Exception Conditions section. Instead, when Full Duplex mode is active and
a frame is being transmitted, the XMTFW bits
(CSR80, bits 9, 8) always gover n when transmit
DMA is requested.
2. Successful reception of the first 64 bytes of every
receive frame is not a requirement for Receiv e DMA
to begin as described in the Receive Exception
Conditions section. Instead, receive DMA will be
requested as soon as either the RCVFW threshold
(CSR80 bits 12, 13) is reached or a complete valid
receive frame is in the Receive FIFO, regardless of
length. This receive FIFO operation is identical to
when the RPA bit (CSR124, bit 3) is set during Half
Duplex mode operation.
MAC Engine changes:
1. Changes to the Transmit Deferral mechanism:
A. Transmission is not deferred while receive is
active.
B. The Inter Packet Gap (IPG) counter which gov-
erns transmit deferral during the IPG between
back-to-back transmits is started when transmit
activity for the first packet ends instead of when
transmit and carrier activity ends.
2. When the AUI or GPSI port is active, Loss of Carrier
(LCAR) reporting is disabled (LCAR is still reported
when the 10BASE-T port is active if a packet is
transmitted while in the Link Fail state).
3. The 4.0 µs carrier sense blinding period after a
transmission during which the SQE test normally
occurs is disabled.
4. When the AUI or GPSI port is active, the SQE Test
error (Collision Error, CERR) reporting is disabled
(CERR is still reported when the 10BASE-T por t is
active if a packet is tr ansmitted while in the Link F ail
state).
5. The collision indication input to the MAC Engine is
ignored.
T-MAU changes:
1. The transmit to receive loopback path in the
T-MAU is disabled.
2. The collision detect circuit is disabled.
3. The “heartbeat” generation (SQE Test function)
is disabled.
Am79C961A69
PRELIMINARY
EADI (External Address Detection
Interface)
This interface is provided to allow external address filtering. It is selected by setting the EADISEL bit in
ISACSR2. This feature is typically utilized for terminal
servers, bridges and/or router type products. The use
of external logic is required to capture the serial bit
stream from the PCnet-ISA II controller, compare it with
a table of stored addresses or identifiers, and perform
the desired function.
The EADI interface operates directly from the NRZ
decoded data and clock recovered by the Manchester
decoder or input to the GPSI, allowing the external
address detection to be performed in parallel with
frame reception and address comparison in the MAC
Station Address Detection (SAD) block.
SRDCLK is provided to allow clocking of the receiv e bit
stream into the external address detection logic.
SRDCLK runs only during frame reception activity.
Once a received frame commences and data and clock
are available , the EADI logic will monitor the alternating
(“1,0") preamble pattern until the two ones of the Start
Frame Delimiter (“1,0,1,0,1,0,1,1") are detected, at
which point the SF/BD output will be driven HIGH.
After SF/BD is asserted the serial data from SRD
should be de-serialized and sent to a content addressable memory (CAM) or other address detection device.
To allow simple serial to parallel conversion, SF/BD is
provided as a strobe and/or marker to indicate the
delineation of bytes, subsequent to the SFD. This provides a mechanism to allow not only capture and/or decoding of the physical or logical (group) address, it also
facilitates the capture of header information to
determine protocol and or inter-networking information.
The EAR
comparison logic to reject the frame.
pin is driven LOW by the external address
If an internal address match is detected by comparison
with either the Physical or Logical Address field, the
frame will be accepted regardless of the condition of
EAR
. Incoming frames which do not pass the internal
address comparison will continue to be received. This
allows approximately 58 byte times after the last destination address bit is available to generate the EAR
signal, assuming the device is not configured to accept
runt packets. EAR will be ignored after 64 byte times
after the SFD, and the frame will be accepted if EAR
has not been asserted before this time. If Runt Packet
Accept is configured, the EAR signal must be
generated prior to the receive message completion,
which could be as short as 12 byte times (assuming 6
bytes for source address, 2 bytes for length, no data, 4
bytes for FCS) after the last bit of the destination
address is available . EAR must have a pulse width of at
least 200 ns.
Note that setting the PROM bit (CSR15, bit 15) will
cause all receive frames to be received, regardless of
the state of the EAR input.
If the DRCUPA bit (CSR15.B) is set and the logical
address (LADRF) is set to zero, only frames which are
not rejected by EAR will be received.
The EADI interface will operate as long as the STRT bit
in CSR0 is set, even if the receiver and/or transmitter
are disabled by software (DTX and DRX bits in CSR15
set). This situation is useful as a power down mode in
that the PCnet-ISA II controller will not perform any
DMA operations; this saves power by not utilizing the
ISA bus driver circuits. However, external circuitry
could still respond to specific frames on the network to
facilitate remote node control.
The table below summarizes the operation of the EADI
features.
1XNo timing requirementsAll Received Frames
01No timing requirementsAll Received Frames
00Low for 200 ns within 512 bits after SFDPhysical/Logical Matches
General Purpose Serial Interface (GPSI)
The PCnet-ISA II controller contains a General
Purpose Serial Interface (GPSI) designed for testing
the digital portions of the chip. The MENDEC, AUI, and
twisted pair interface are by-passed once the device is
set up in the special “test mode” f or accessing the GPSI
functions. Although this access is intended only for
testing the device, some users may find the
non-encoded data functions useful in some special
70Am79C961A
applications. Note, however, that the GPSI functions
can be accessed only when the PCnet-ISA II devices
operate as a bus master.
The PCnet-ISA II GPSI signals are consistent with the
LANCE digital serial interface. Since the GPSI functions can be accessed only through a special test
mode, expect some loss of functionality to the device
when the GPSI is invoked. The AUI and 10BASE-T
analog interfaces are disabled along with the internal
PRELIMINARY
MENDEC logic. The LA (unlatched address) pins are
removed and become the GPSI signals, theref ore, only
20 bits of address space is available. The table below
shows the GPSI pin configuration:
T o in voke the GPSI signals, f ollow the procedure below:
1. After reset or I/O read of Reset Address, write 10b
to PORTSEL bits in CSR15.
2. Set the ENTST bit in CSR4
3. Set the GPSIEN bit in CSR124 (see note below)
(The pins LA17–LA23 will change function after the
completion of the above three steps.)
4. Clear the ENTST bit in CSR4
5. Clear Media Select bits in ISACSR2
6. Define the PORTSEL bits in the MODE register
(CSR15) to be 10b to define GPSI port. The MODE
register image is in the initialization block.
Note: LA pins will be tristated before writing to GPSIEN bit.
After writing to GPSIEN, LA[17–21] will be inputs, LA[22–23]
will be outputs.
The GPSI Function is available only in the Bus Master Mode of operation.
I/O Type
LANCE
GPSI Pin
PCnet-ISA II
GPSI Pin
PCnet-ISA II
Pin Number
PCnet-ISA II Normal
Pin Function
Am79C961A71
PRELIMINARY
IEEE 1149.1 Test Access Port Interface
An IEEE 1149.1 compatible boundary scan Test Access
Port is provided for board-level continuity test and diagnostics. All digital input, output, and input/output pins are
tested. Analog pins, including the AUI differential driver
(DO±) and receivers (DI±, CI±), and the crystal input
(XTAL1/XTAL2) pins, are tested. The T-MAU drivers
TXD±, TXP±, and receiver RXD± are also tested.
The following is a brief summary of the IEEE 1149.1
compatible test functions implemented in the
PCnet-ISA II controller.
Boundary Scan Circuit
The boundary scan test circuit requires four extra pins
(TCK, TMS, TDI and TDO), defined as the Test Access
Port (TAP). It includes a finite state machine (FSM), an
instruction register, a data register array, and a
power-on reset circuit. Inter nal pull-up resistors are
provided for the TDI, TCK, and TMS pins. The TCK pin
must not be left unconnected. The boundar y scan circuit remains active during sleep.
TAP FSM
The TAP engine is a 16-state FSM, driven by the Test
Clock (TCK) and the Test Mode Select (TMS) pins. This
FSM is in its reset state at power-up or RESET. An
independent power-on reset circuit is provided to
ensure the FSM is in the TEST_LOGIC_RESET state
at power-up.
Supported Instructions
In addition to the minimum IEEE 1149.1 requirements
(BYPASS, EXTEST and SAMPLE instructions), three
additional instructions (IDCODE, TRIBYP and SETBYP)
are provided to further ease board-level testing. All
unused instruction codes are reserved. See the table
below for a summary of supported instructions.
Instruction Register and Decoding Logic
After hardware or software RESET, the IDCODE
instruction is always invoked. The decoding logic gives
signals to control the data flow in the DATA registers
according to the current instruction.
Boundary Scan Register (BSR)
Each BSR cell has two stages. A flip-flop and a latch
are used in the SERIAL SHIFT ST A GE and the PARALLEL OUTPUT STAGE, respectively.
There are four possible operational modes in the BSR cell:
1Capture
2Shift
3Update
4System Function
Other Data Registers
(1) BYPASS REG (1 BIT)
(2) DEV ID REG (32 bits
Bits 31–28:Version
Bits 27–12:Part number (2261h)
Bits 11–1:Manufacturer ID. The 11 bit
manufacturer ID code for AMD is
00000000001 according to JEDEC
Publication 106-A.
TRIBYPF orce TristateBypassNormal0011
SETBYPControl Boundary to 1/0BypassTest0100
BYPASSBypass ScanBypassNormal1111
Power Saving Modes
The PCnet-ISA II controller supports two hardware
power-savings modes. Both are entered by asserting
the SLEEP pin LOW.
In coma mode, the PCnet-ISA II controller will go into
deep sleep with no support to automatically wake itself
up. Sleep mode is enabled when the AWAKE bit in
Selected
Data RegMode
ISACSR2 is reset. This mode is the default powerdown
mode.
In Snooze mode, enabled by setting the AWAKE bit in
ISACSR2 and driving the SLEEP pin LOW, the T-MAU
receive circuitry will remain enabled even while the
SLEEP pin is driven LOW. The LED0 output will also
continue to function, indicating a good 10BASE-T link if
72Am79C961A
Instruction
Code
PRELIMINARY
there are link beat pulses or valid frames present. This
LED0 pin can be used to drive a LED and/or external
hardware that directly controls the SLEEP pin of the
PCnet-ISA II controller. This configuration effectively
wakes the system when there is any activity on the
10BASE-T link.
Access Operations (Software)
We begin by describing how byte and word data are
addressed on the ISA bus, including conv ersion cycles
where 16-bit accesses are turned into 8-bit accesses
because the resource accessed did not support 16-bit
operations. Then we describe how registers and other
resources are accessed. This section is for the device
programmer, while the next section (bus cycles) is for
the hardware designer.
I/O Resources
The PCnet-ISA II controller has both I/O and memory
resources. In the I/O space the resources are organized as indicated in the following table:
The PCnet-ISA II controller does not respond to any
addresses outside of the offset range 0-17h. I/O offsets
18h and up are not used by the PCnet-ISA II controller .
Offset #BytesRegister
0h16IEEE Address
10h2RDP
12h2RAP(shared by RDP and IDP)
14h2Reset
16h2IDP
I/O Register Access
The register address port (RAP) is shared by the register data port (RDP) and the ISACSR data port (IDP) to
save registers. To access the Ethernet controller’s RDP
or IDP, the RAP should be wr itten first, followed by the
read or write access to the RDP or IDP. I/O register
accesses should be coded as 16-bit accesses, even if
the PCnet-ISA II controller is hardware configured for
8-bit I/O bus cycles. It is acceptable (and transparent)
for the motherboard to turn a 16-bit software access
into two separate 8-bit hardware bus cycles. The motherboard accesses the low byte before the high b yte and
the PCnet-ISA II controller has circuitry to specifically
support this type of access.
The reset register causes a reset when read. An y value
will be accepted and the cycle may be 8 or 16 bits wide.
Writes are ignored.
All PCnet-ISA II controller register accesses should be
coded as 16-bit operations.
“Note that the RAP is cleared on Reset.”
IEEE Address Access
The address PROM may be an external memor y
device that contains the node’s unique physical Ethernet address and any other data stored by the board
manufacturer. The software accesses must be 16-bit.
This information may be stored in the EEPROM.
Boot PROM Access
The boot PROM is an exter nal memory resource
located by the address selected by the EEPROM or the
BPAM input in slave mode. It may be software
accessed as an 8-bit or 16-bit resource but the latter is
recommended for best performance.
Static RAM Access
The static RAM is only present in the Bus Slave mode.
In the Bus Slave mode, two SRAM access schemes
are available. When the Shared Memor y architecture
mode is selected, the SRAM is accessed using ISA
memory cycles to the address range selected by the
input. It may be accessed as an 8 or 16-bit
SMAM
resource but the latter is recommended for best perf ormance. When the Programmed I/O architecture mode
is selected, the SRAM is accessed through ISACSR0
and ISACSR1 using the RAP and IDP.
Bus Cycles (Hardware)
The PCnet-ISA II controller supports both 8-bit and
16-bit hardware bus cycles. The following sections outline where any limitations apply based upon the architecture mode and/or the resource that is being
accessed (PCnet-ISA II controller registers, address
PROM, boot PROM, or shared memory SRAM). For
completeness, the following sections are arranged by
architecture (Bus Master Mode or Bus Slave Mode).
SRAM resources apply only to Bus Slave Mode.
All resources (registers, PROMs, SRAM) are presented to the ISA bus by the PCnet-ISA II controller.
With few exceptions, these resources can be configured for either 8-bit or 16-bit bus cycles. The I/O
resources (registers, address PROM) are width configured using the EEPROM. The memory resources (boot
PROM, SRAM) are width configured by external hardware.
For 16-bit memory accesses, hardware external to the
PCnet-ISA II controller asserts MEMCS16 when either
of the two memory resources is selected. The ISA bus
requires that all memory resources within a block of
128 Kbytes be the same width, either 8- or 16-bits. The
reason for this is that the MEMCS16 signal is generally
a decode of the LA17-23 address lines. 16-bit memory
capability is desirable since two 8-bit accesses take the
same amount of time as four 16-bit accesses.
All accesses to 8-bit resources (which do not return
MEMCS16 or IOCS16) use SD0-7. If an odd byte is
accessed, the Current Master swap buffer turns on.
Am79C961A73
PRELIMINARY
During an odd byte read the swap buffer copies the
data from SD0-7 to the high byte. Dur ing an odd byte
write the Current Master swap buffer copies the data
from the high byte to SD0-7. The PCnet-ISA II controller can be configured to be an 8-bit I/O resource even
in a 16-bit system; this is set by the EEPROM. It is recommended that the PCnet-ISA II controller be configured for 8-bit only I/O bus cycles for maximum
compatibility with PC/AT clone motherboards.
When the PCnet-ISA II controller is in an 8-bit system
such as a PC/XT, SBHE
and IOCS16 must be left
unconnected (these signals do not exist in the PC/XT).
This will force ALL resources (I/O and memory) to support only 8-bit bus cycles. The PCnet-ISA II controller
will function in an 8-bit system only if configured for Bus
Slave Mode.
Accesses to 16-bit resources (which do return
MEMCS16 or IOCS16) use either or both SD0–7 and
SD8–15. A word access is indicated by A0=0 and
SBHE=0 and data is transferred on all 16 data lines. An
even byte access is indicated by A0=0 and SBHE=1
and data is transferred on SD0–7. An odd-byte access
is indicated by A0=1 and SBHE=0 and data is transferred on SD8-15. It is illegal to have A0=1 and
SBHE=1 in any bus cycle. The PCnet-ISA II controller
returns only IOCS16; MEMCS16 must be generated b y
external hardware if desired. The use of MEMCS16
applies only to Shared Memory Mode.
The following table describes all possible types of ISA
bus accesses, including Permanent Master as Current
Master and PCnet-ISA II controller as Current Master.
The PCnet-ISA II controller will not work with 8-bit
ISA Bus Accesses
memory while it is Current Master. Any descriptions of
8-bit memory accesses are for when the Permanent
Master is Current Master.
The two byte columns (D0–7 and D8–15) indicate
whether the bus master or slave is driving the byte.
CS16
is a shorthand for MEMCS16 and IOCS16.
Bus Master Mode
The PCnet-ISA II controller can be configured as a Bus
Master only in systems that support bus mastering. In
addition, the system is assumed to support 16-bit
memory (DMA) cycles (the PCnet-ISA II controller
does not use the MEMCS16
signal on the ISA bus).
This does not preclude the PCnet-ISA II controller from
doing 8-bit I/O transfers. The PCnet-ISA II controller will
not function as a bus master in 8-bit platforms such as
the PC/XT.
Refresh Cycles
Although the PCnet-ISA II controller is neither an originator or a receiver of refresh cycles, it does need to
avoid unintentional activity during a refresh cycle in bus
master mode. A refresh cycle is performed as follows:
First, the REF signal goes active. Then a valid refresh
address is placed on the address bus. MEMR goes active, the refresh is performed, and MEMR goes inactive. The refresh address is held for a short time and
them goes invalid. Finally, REF goes inactive. During
a refresh cycle, as indicated by REF being active, the
PCnet-ISA II controller ignores DACK if it goes active
until it goes inactive. It is necessar y to ignore DACK
during a refresh because some motherboards generate a false DACK at that time.
R/WA0SBHECS16D0–7D8–15Comments
RD01xSlaveFloatLow byte RD
RD101SlaveFloatHigh byte RD with swap
RD001SlaveFloat16-Bit RD converted to low byte RD
RD100FloatSlaveHigh byte RD
RD000SlaveSlave16-Bit RD
WR01xMasterFloatLow byte WR
WR101MasterFloatHigh byte WR with swap
WR001MasterMaster16-Bit WR converted to
The Address PROM is a small (16 bytes) 8-bit PROM
connected to the PCnet-ISA II controller Private Data
Bus. The PCnet-ISA II controller will support only 8-bit
ISA I/O bus cycles for the address PROM; this limitation is transparent to software and does not preclude
16-bit software I/O accesses. An access cycle begins
74Am79C961A
PRELIMINARY
with the Permanent Master driving AEN LOW, driving
the addressess valid, and driving IOR active. The
PCnet-ISA II controller detects this combination of signals and arbitrates for the Private Data Bus (PRDB) if
necessary. IOCHRDY is driven LOW dur ing accesses
to the address PROM.
When the Private Data Bus becomes available, the
PCnet-ISA II controller drives APCS active, releases
IOCHRDY, turns on the data path from PRD0-7, and
enables the SD0-7 drivers (but not SD8-15). During
this bus cycle, IOCS16
tion is maintained until IOR goes inactive, at which time
the bus cycle ends. Data is remov ed from SD0-7 within
30 ns.
is not driven active. This condi-
Address PROM Cycles Using EEPROM Data
Default mode. In this mode , the IEEE address information is stored not in an external parallel PROM but in the
EEPROM along with other configuration information.
PCnet-ISA II will respond to I/O reads from the IEEE
address (the first 16 bytes of the I/O map) by supplying
data from an internal RAM inside PCnet-ISA II. This internal RAM is loaded with the IEEE address at RESET
and is write protected.
Ethernet Controller Register Cycles
Ethernet controller registers (RAP, RDP, IDP) are naturally 16-bit resources but can be configured to operate
with 8-bit bus cycles provided the proper protocol is followed. This means on a read, the PCnet-ISA II controller will only drive the low byte of the system data bus; if
an odd byte is accessed, it will be swapped do wn. The
high byte of the system data bus is never driven by the
PCnet-ISA II controller under these conditions. On a
write cycle, the even b yte is placed in a holding register.
An odd byte write is internally swapped up and augmented with the even b yte in the holding register to provide an internal 16-bit write. This allo ws the use of 8-bit
I/O bus cycles which are more likely to be compatible
with all ISA-compatible clones, but requires that both
bytes be written in immediate succession. This is
accomplished simply by treating the PCnet-ISA II controller registers as 16-bit software resources. The
motherboard will convert the 16-bit accesses done by
software into two sequential 8-bit accesses, an even
byte access followed immediately by an odd byte
access.
An access cycle begins with the Permanent Master
driving AEN LOW , driving the address valid, and driving
IOR or IOW active. The PCnet-ISA II controller detects
this combination of signals and drives IOCHRDY LOW.
IOCS16 will also be driven LOW if 16-bit I/O bus cycles
are enabled. When the register data is ready,
IOCHRDY will be released HIGH. This condition is
maintained until IOR or IOW goes inactive, at which
time the bus cycle ends.
RESET Cycles
A read to the reset address causes an PCnet-ISA II
controller reset. This has the same effect as asserting
the RESET pin on the PCnet-ISA+ controller (which
happens on system power up or on a hard boot) except
that the T-MAU is NOT reset. The T-MAU will retain its
link pass/fail state, disregarding the software RESET
command. The subsequent write cycle needed in the
NE2100 LANCE based family of Ethernet cards is not
required but does not have any harmful effects.
IOCS16
is not asserted in this cycle.
ISA Configuration Register Cycles
The ISA configuration registers are accessed by placing the address of the desired register into the RAP and
reading the IDP. The ISACSR bus cycles are identical
to all other PCnet-ISA II controller register bus cycles.
Boot PROM Cycles
The Boot PROM is an 8-bit PROM connected to the
PCnet-ISA II controller Private Data Bus (PRDB) and
can occupy up to 64K of address space. Since the
PCnet-ISA II controller does not generate MEMCS16,
only 8-bit ISA memory bus cycles to the boot PROM
are supported in Bus Master Mode; this limitation is
transparent to software and does not preclude 16-bit
software memory accesses. A boot PROM access
cycle begins with the Permanent Master driving the
addresses valid, REF inactive, and MEMR active. (AEN
is not involved in memory cycles). The PCnet-ISA II
controller detects this combination of signals, drives
IOCHRDY LOW, and reads a byte out of the Boot
PROM. The data byte read is driv en onto the lower system data bus lines and IOCHRDY is released. This
condition is maintained until MEMR goes inactive, at
which time the access cycle ends.
The BPCS signal generated by the PCnet-ISA II controller is three 20 MHz clock cycles wide (300 ns).
Including delays, the Boot PROM has 275 ns to
respond to the BPCS signal from the PCnet-ISA II controller. This signal is intended to be connected to the
CS pin on the boot PROM, with the PROM OE pin tied
to ground.
Current Master Operation
Current Master operation only occurs in the Bus Master
mode. It does not occur in the Bus Slave mode.
There are three phases to the use of the bus by the
PCnet-ISA II controller as Current Master, the Obtain
Phase, the Access Phase, and the Release Phase.
Obtain Phase
A Master Mode Transfer Cycle begins by asserting
DRQ. When the Permanent Master asser ts DACK, the
PCnet-ISA II controller asserts MASTER, signifying it
has taken control of the ISA bus. The Permanent Master tristates the address, command, and data lines
Am79C961A75
PRELIMINARY
within 60 ns of DACK going active. The Permanent
Master drives AEN inactive within 71 ns of MASTER
going active.
Access Phase
The ISA bus requires a wait of at least 125 ns after
MASTER is asserted before the new master is allowed
to drive the address, command, and data lines. The
PCnet-ISA II controller will actually wait 3 clock cycles
or 150 ns.
The following signals are not driven by the Permanent
Master and are simply pulled HIGH: BALE, IOCHRDY,
IOCS16
II controller assumes the memory which it is accessing
is 16 bits wide and can complete an access in the time
programmed for the PCnet-ISA II controller MEMR and
MEMW signals. Refer to the ISA Bus Configuration
Register description section.
, MEMCS16, SRDY. Therefore, the PCnet-ISA
Release Phase
When the PCnet-ISA II controller is finished with the
bus, it drives the command lines inactive. 50 ns later,
the controller tri-states the command, address, and
data lines and drives DRQ inactive. 50 ns later , the controller drives MASTER inactive.
The Permanent Master drives AEN active within 71 ns
of MASTER going inactive. The Permanent Master is
allowed to drive the command lines no sooner than 60
ns after DACK goes inactive.
Master Mode Memory Read Cycle
After the PCnet-ISA II controller has acquired the ISA
bus, it can perform a memory read cycle. All timing is
generated relative to the 20 MHz clock (network clock).
Since there is no way to tell if memory is 8-bit or 16-bit
or when it is ready, the PCnet-ISA II controller by
default assumes 16-bit, 1 wait state memory. The wait
state assumption is based on the default value in the
MSRDA register in ISACSR0.
The cycle begins with SA0-19, SBHE, and LA17-23
being presented. The ISA bus requires them to be valid
for at least 28 ns before a read command and the
PCnet-ISA II controller provides one clock or 50 ns of
setup time before asserting MEMR.
The ISA bus requires MEMR to be active for at least
219 ns, and the PCnet-ISA II controller provides a
default of 5 clocks, or 250 ns, but this can be tuned for
faster systems with the Master Mode Read Active
(MSRDA) register (see section 2.5.2). Also, if
IOCHRDY is dr iven LOW, the PCnet-ISA II controller
will wait. The wait state counter must expire and
IOCHRD Y must be HIGH f or the PCnet-ISA II controller
to continue.
The PCnet-ISA II controller then accepts the memory
read data. The ISA bus requires all command lines to
remain inactive for at least 97 ns before starting
another bus cycle and the PCnet-ISA II controller provides at least two clocks or 100 ns of inactive time.
The ISA bus requires read data to be valid no more
than 173 ns after receiving MEMR
PCnet-ISA II controller requires 10 ns of data setup
time. The ISA b us requires read data to provide at least
0 ns of hold time and to be removed from the bus within
30 ns after MEMR goes inactive. The PCnet-ISA II controller requires 0 ns of data hold time.
active and the
Master Mode Memory Write Cycle
After the PCnet-ISA II controller has acquired the ISA
bus, it can perform a memory write cycle. All timing is
generated relative to a 20 MHz clock which happens to
be the same as the network clock. Since there is no
way to tell if memory is 8- or 16-bit or when it is ready,
the PCnet-ISA II controller by default assumes 16-bit, 1
wait state memory. The wait state assumption is based
on the default value in the MSWRA register in
ISACSR1.
The cycle begins with SA0-19, SBHE, and LA17-23
being presented. The ISA bus requires them to be valid
at least 28 ns before MEMW goes active and data to be
valid at least 22 ns before MEMW goes active. The
PCnet-ISA II controller provides one clock or 50 ns of
setup time for all these signals.
The ISA bus requires MEMW to be active for at least
219 ns, and the PCnet-ISA II controller provides a
default of 5 clocks, or 250 ns, but this can be tuned for
faster systems with the Master Mode Write Active
(MSWRA) register (ISACSR1). Also, if IOCHRDY is
driven LOW, the PCnet-ISA II controller will wait.
IOCHRD Y must be HIGH f or the PCnet-ISA II controller
to continue.
The ISA bus requires data to be valid f or at least 25 ns
after MEMW goes inactive, and the PCnet-ISA II controller provides one clock or 50 ns.
The ISA bus requires all command lines to remain
inactive for at least 97 ns before starting another bus
cycle. The PCnet-ISA II controller provides at least two
clocks or 100 ns of inactive time when bit 4 in ISA CSR2
is set. The EISA bus requires all command lines to
remain inactive for at least 170 ns before star ting
another bus cycle. When bit 4 in ISACSR4 is cleared,
the PCnet-ISA II controller provides 200 ns of inactive
time.
Back-to-Back DMA Requests
The PCnet-ISA II provides for fair bus bandwidth sharing between two bus mastering devices on the ISA bus
through an adaptive delay which is inserted between
back-to-back DMA requests.
When the PCnet-ISA II requires bus access immediately following a bus ownership period, it first checks
the status of the three currently unused DRQ pins. If a
76Am79C961A
PRELIMINARY
lower priority DRQ pin than the one currently being
used by the PCnet-ISA II is asserted, the PCnet-ISA II
will wait 2.6 µs after the deassertion of DACK before
re-asserting its DRQ pin. If no lower priority DRQ pin is
asserted, the PCnet-ISA II may re-assert its DRQ pin
after as short as 1.1 µs following DACK deassertion.
The priorities assumed by the PCnet-ISA II are ordered
DRQ3, DRQ5, DRQ6, DRQ7, with DRQ3 having highest priority and DRQ7 having the lowest priority. This
priority ordering matches that used by typical ISA bus
DMA controllers.
This adaptive delay scheme allows for fair bus bandwidth sharing when two bus mastering devices, e.g.
two PCnet-ISA II devices, are on an ISA bus. The controller using the higher priority DMA channel cannot
lock out the controller using the lower priority DMA
channel because of the 2.6 µs delay that is inserted
before DRQ reassertion when a lower priority DRQ pin
is asserted. When there is no lower priority DMA
request asserted, the PCnet-ISA II re-requests the bus
immediately, providing optimal performance when
there is no competition for bus access.
Bus Slave Mode
The PCnet-ISA II can be configured to be a bus slave
for systems that do not support bus mastering or
require a local memory to tolerate high bus latencies.
In the Bus Slave mode, the I/O map of the PCnet-ISA II
is identical to the I/O map when in the Bus Master
mode (see I/O Resources section). Hence , the address
PROM, controller registers, and Reset port are
accessed through I/O cycles on the ISA bus. However,
the initialization block, descriptor rings, and buffers,
which are located in system memory when in the Bus
Master mode, are located in a local SRAM when in the
Bus Slave mode. The local SRAM can be accessed by
memory cycles on the ISA bus (Shared Memory architecture) or by I/O cycles on the ISA bus (Programmed
I/O mode).
Address PROM Cycles External PROM
The Address PROM is a small (16 bytes) 8-bit PROM
connected to the PCnet-ISA II controller Private Data
Bus (PRDB). The PCnet-ISA II controller will suppor t
only 8-bit ISA I/O bus cycles for the address PROM;
this limitation is transparent to software and does not
preclude 16-bit software I/O accesses. An access cycle
begins with the Permanent Master driving AEN LOW,
driving the addresses valid, and driving IOR active. The
PCnet-ISA II controller detects this combination of signals and arbitrates for the Private Data Bus if necessary. IOCHRDY is always dr iven LOW during address
PROM accesses.
When the Private Data Bus becomes available, the
PCnet-ISA II controller drives APCS active, releases
IOCHRDY, turns on the data path from PRD0-7, and
enables the SD0-7 drivers (but not SD8-15). During this
bus cycle, IOCS16
maintained until IOR goes inactive, at which time the
access cycle ends. Data is removed from SD0-7 within
30 ns.
The PCnet-ISA II controller will perform 8-bit ISA bus
cycle operation for all resources (registers, PROMs,
SRAM) if SBHE has been left unconnected, such as in
the case of an 8-bit system like the PC/XT.
is not driven active. This condition is
Ethernet Controller Register Cycles
Ethernet controller registers (RAP, RDP, ISACSR) are
naturally 16-bit resources but can be configured to
operate with 8-bit bus cycles provided the proper protocol is followed. This is programmable by the
EEPROM. This means on a read, the PCnet-ISA II controller will only drive the low byte of the system data
bus; if an odd byte is accessed, it will be swapped
down. The high byte of the system data bus is never
driven by the PCnet-ISA II controller under these conditions. On a write, the even byte is placed in a holding
register. An odd-b yte write is internally swapped up and
augmented with the even b yte in the holding register to
provide an internal 16-bit write. This allows the use of
8-bit I/O bus cycles which are more likely to be compatible with all clones, but requires that both b ytes be written in immediate succession. This is accomplished
simply by treating the PCnet-ISA II controller controller
registers as 16-bit software resources. The motherboard will convert the 16-bit accesses done by software
into two sequential 8-bit accesses, an even-byte
access followed immediately by an odd-byte access.
An access cycle begins with the Permanent Master
driving AEN LOW , driving the address valid, and driving
or IOW active. The PCnet-ISA II controller detects
IOR
this combination of signals and drives IOCHRDY LOW.
IOCS16 will also be driven LOW if 16-bit I/O bus cycles
are enabled. When the register data is ready,
IOCHRDY will be released HIGH. This condition is
maintained until IOR or IOW goes inactive, at which
time the bus cycle ends.
The PCnet-ISA II controller will perform 8-bit ISA bus
cycle operation for all resources (registers, PROMs,
SRAM) if SBHE has been left unconnected, such as in
the case of an 8-bit system like the PC/XT.
RESET Cycles
A read to the reset address causes an PCnet-ISA II
controller reset. This has the same effect as asserting
the RESET pin on the PCnet-ISA+ controller (which
happens on system power up or on a hard boot) except
that the T-MAU is NOT reset. The T-MAU will retain its
link pass/fail state, disregarding the software RESET
command. The subsequent write cycle needed in the
NE2100 LANCE- based family of Ethernet cards is not
required but does not have any harmful effects.
IOCS16 is not asserted in this cycle.
Am79C961A77
PRELIMINARY
ISA Configuration Register Cycles
The ISA configuration register is accessed by placing
the address of the desired register into the RAP and
reading the IDP. The ISACSR bus cycles are identical
to all other PCnet-ISA II controller register bus cycles.
Boot PROM Cycles
The Boot PROM is an 8-bit PROM connected to the
PCnet-ISA II controller Private Data Bus (PRDB), and
can occupy up to 64 Kbytes of address space. In
Shared Memory Mode, an external address comparator is responsible for asserting BP
II controller. BPAM is intended to be a perfect decode
of the boot PROM address space, i.e. LA17-23, SA16.
The LA bus must be latched with BALE in order to provide stable signal for BPAM. REF inactive must be used
by the exter nal logic to gate boot PROM address
decoding. This same logic must asser t MEMCS16 to
the ISA bus if 16-bit Boot PROM bus cycles are
desired.
In the Bus Slave mode, boot PR OM cycles can be programmed to be 8 or 16-bit ISA memory cycles with the
BP_16B bit (PnP 0x42). If the BP_16B bit is set, the
PCnet-ISA II assumes 16-bit ISA memory cycles for
the boot PROM. In this case, the external hardware
responsible for generating BPAM must also generate
MEMCS16. A 16-bit boot PROM bus cycle begins with
the Permanent Master driving the addresses valid and
MEMR active. (AEN is not involved in memory cycles).
External hardware would assert BP AM and MEMCS16.
The PCnet-ISA II controller detects this combination of
signals, drives IOCHRDY LOW, and reads two bytes
out of the boot PROM. The data bytes read from the
PROM are driven by the PCnet-ISA II controller onto
SD0-15 and IOCHRDY is released. This condition is
maintained until MEMR goes inactive, at which time the
access cycle ends.
The PCnet-ISA II controller will perform 8-bit ISA bus
cycle operation for all resource (registers, PROMs,
SRAM) if SBHE has been left unconnected, such as in
the case of an 8-bit system like the PC/XT.
The BPCS signal generated by the PCnet-ISA II controller is three 20 MHz clock cycles wide (350 ns).
Including delays, the Boot PROM has 275 ns to
respond to the BPCS signal from the PCnet-ISA II controller. This signal is intended to be connected to the
CS pin on the boot PROM, with the PROM OE pin tied
to ground.
AM to the PCnet-ISA
Static RAM Cycles – Shared Memory Architecture
In the Shared Memory Architecture mode, the SRAM is
an 8-bit device connected to the PCnet-ISA II controller
Private Bus, and can occupy up to 64 Kbytes of
address space. The SRAM is memory mapped into the
ISA memory space at an address range determined by
external decode logic. The external address compara-
tor is responsible for asserting SMAM
II controller. SMAM is intended to be a perfect decode
of the SRAM address space, i.e. LA17-23, SA16 for 64
Kbytes of SRAM. The LA signals must be latched by
BALE in order to provide a stable decode for SMAM.
The PCnet-ISA II controller assumes 16-bit ISA memory bus cycles for the SRAM, so this same logic must
assert MEMCS16 to the ISA bus if 16-bit bus cycles are
to be supported.
A 16-bit SRAM bus cycle begins with the Permanent
Master driving the addresses valid, REF
either MEMR or MEMW active. (AEN is not involved in
memory cycles). External hardware would assert
SMAM and MEMCS16. The PCnet-ISA II controller
detects this combination of signals and initiates the
SRAM access.
In a write cycle, the PCnet-ISA II controller stores the
data into an internal holding register, allowing the ISA
bus cycle to finish normally . The data in the holding register will then be written to the SRAM without the need
for ISA bus control. In the event the holding register is
already filled with unwritten SRAM data, the PCnet-ISA
II controller will extend the ISA write cycle by driving
IOCHRD Y LOW until the unwritten data is stored in the
SRAM. The current ISA bus cycle will then complete
normally.
In a read cycle, the PCnet-ISA II controller arbitrates for
the Private Bus. If it is unavailable, the PCnet-ISA II
controller drives IOCHRDY LOW. The PCnet-ISA II
controller compares the 16 bits of address on the System Address Bus with that of a data word held in an
internal pre-fetch register.
If the address does not match that of the prefetched
SRAM data, then the PCnet-ISA II controller drives
IOCHRDY LOW and reads two bytes from the SRAM.
The PCnet-ISA II controller then proceeds as though
the addressed data location had been prefetched.
If the internal prefetch buffer contains the correct data,
then the pre-fetch buffer data is driven on the System
Data bus. If IOCHRDY was previously driv en LOW due
to either Private Data Bus arbitration or SRAM access,
then it is released HIGH. The PCnet-ISA II controller
remains in this state until MEMR is de-asserted, at
which time the PCnet-ISA II controller performs a new
prefetch of the SRAM. In this way memory read wait
states can be minimized.
The PCnet-ISA II controller performs prefetches of the
SRAM between ISA bus cycles. The SRAM is
prefetched in an incrementing word address fashion.
Prefetched data are inv alidated by an y other activity on
the Private Bus, including Shared Memory Writes by
either the ISA bus or the network interface, and also
address and boot PROM reads.
to the PCnet-ISA
inactive, and
78Am79C961A
PRELIMINARY
The only way to configure the PCnet-ISA II controller
for 8-bit ISA bus cycles for SRAM accesses is to configure the entire PCnet-ISA II controller to support only
8-bit ISA bus cycles. This is accomplished by leaving
the SBHE pin disconnected. The PCnet-ISA II controller will perform 8-bit ISA bus cycle operation for all
resources (registers, PROMs, SRAM) if SBHE has
never been driven activ e since the last RESET, such as
in the case of an 8-bit system like the PC/XT. In this
case, the external address decode logic must not
assert MEMCS16
to the ISA bus, which will be the case
if MEMCS16 is left unconnected. It is possible to manufacture a dual 8/16 bit PCnet-ISA II controller adapter
card, as the MEMCS16 and SBHE signals do not exist
in the PC/XT environment.
At the memory device level, each SRAM Private Bus
read cycle takes two 50 ns clock periods for a maximum read access time of 75 ns. The timing looks like
this:
XTAL1
(20 MHz)
Address
SR
OE
19364A-14
Static RAM Read Cycle
The address and SROE go active within 20 ns of the
clock going HIGH. Data is required to be valid 5 ns
before the end of the second clock cycle. Address and
SROE have a 0 ns hold time after the end of the second
clock cycle. Note that the PCnet-ISA II controller does
not normally provide a separate SRAM CS signal;
SRAM CS must always be asserted.
SRAM Private Bus write cycles require three 50 ns
clock periods to guarantee non-negative address setup
and hold times with regard to SRWE. The timing is
illustrated as follows:
XTAL1
(20 MHz)
Address/
Data
SRWE
Static RAM Write Cycle
19364A-15
Address and data are valid 20 ns after the rising edge
of the first clock period. SR
WE goes active 20 ns after
the falling edge of the first clock period. SRWE goes
inactive 20 ns after the falling edge of the third clock
period. Address and data remain valid until the end of
the third clock period. Rise and fall times are nominally
5 ns. Non-negative setup and hold times for address
and data with respect to SRWE are guaranteed. SR WE
has a pulse width of typically 100 ns, minimum 75 ns.
Static RAM Cycles – Programmed I/O Architecture
In the Programmed I/O Architecture mode, the SRAM
is an 8-bit device connected to the PCnet-ISA II controller Private Bus, and can occupy up to 64 Kbytes of
address space. The SRAM is accessed through the
ISACSR0 and ISACSR1 registers which serve as the
SRAM Data port and SRAM Address pointer, respectively. Since the ISACSRs are used to access the
SRAM, simple I/O accesses (to RAP and IDP) which
are decoded by the PCnet-ISA II are used to access
the SRAM without any external decoding logic.
The RAP and IDP ports are naturally 16-bit resources
and can be accessed with 16-bit ISA I/O cycles if the
IO_MODE bit (PnP 0xF0) is set. As discussed in the
Ethernet Controller Register Cycles section, 8-bit I/O
cycles are also allowed, provided the proper protocol is
followed. This protocol requires that byte accesses
must be performed in pairs, with the even byte access
always being followed by associated odd byte access.
In the Programmed I/O architecture mode, when
accessing the SRAM Data Port in particular
(ISACSR0), the restrictions on byte accesses are
slightly different. Even byte accesses (accesses where
A0 = 0, SBHE = 1) may be performed to ISACSR0 without any restriction. A corresponding odd byte access
need not be performed following the even byte access
as is required when accessing all other controller registers. In fact, odd byte accesses (accesses where A0
= 1, SBHE = 1) may not be performed to ISACSR0, e xcept when they are the result of a software 16-bit
access that are automatically converted to two byte accesses by motherboard logic.
Since the internal PCnet-ISA II registers are used to
access the SRAM in the Programmed I/O architecture
mode, the access cycle on the ISA bus is identical to
that described in the Ethernet Controller Register
Cycles section.
To minimize the number of I/O cycles required to
access the SRAM, the PCnet-ISA II auto-increments
the SRAM Address Pointer (ISACSR1) by one or two
following every read or write to the SRAM Data Port
(ISACSR0). If a single byte read or write to the SRAM
Data Port occurs, the SRAM Address Pointer is automatically incremented by 1. If a word read or write to
the SRAM Data Por t occurs, the SRAM Address
Pointer is automatically incremented by 2. This allows
Am79C961A79
PRELIMINARY
reads and writes to adjacent ascending addresses in
the SRAM to be performed without intervening writes to
the SRAM Address Pointer. Since buffer accesses
comprise a high percentage of all accesses to the
SRAM, and buffer accesses are typically performed in
adjacent ascending order, the auto-increment of the
SRAM Address Pointer reduces the required ISA bus
cycles significantly.
In addition to the auto-incrementing of the SRAM
Address pointer, the PCnet-ISA II performs write posting on writes to the SRAM and read prefetching on
reads from the SRAM to maximize performance in the
Programmed I/O architecture mode.
Write Posting: When a write cycle to the SRAM Data
Port occurs, the PCnet-ISA II controller stores the data
into an internal holding register, allowing the ISA bus
cycle to finish normally . The data in the holding register
will then be written to the SRAM without the need for
ISA bus control. In the event that the holding register is
already filled with unwritten SRAM data, the PCnet-ISA
II controller will extend the ISA write cycle by driving
OCHRDY LOW until the unwritten data is stored in the
SRAM. Once the data is written into the SRAM, the
new write data is stored into the internal holding register and IOCHRDY is released allowing the ISA bus
cycle to complete.
Read Prefetching: To gain performance on read
accesses to the SRAM, the PCnet-ISA II performs
prefetches of the SRAM after ever y read from the
SRAM Data Port. The prefetch is performed using the
speculated address that results from the
auto-increment that occurs on the SRAM Address
Pointer following every access to the SRAM Data Port.
Following every read access, the 16-bit word following
the just-read SRAM byte or word is prefetched and
placed in a holding register. If a word read from the
SRAM Data Port occurs before a “prefetch invalidation
event” occurs, the prefetched word is driven onto the
SD[15:0] pins without a wait state (no IOCHRDY LOW
assertion). A “prefetch invalidation event” is defined as
any activity on the Private Bus other than SRAM reads.
This includes SRAM writes by either the ISA bus or the
network interface, address or boot PROM reads, or an y
write to the SRAM Address Pointer.
The PCnet-ISA II interface to the SRAM in the Programmed I/O architecture mode is identical to that in
the Shared Memory Architecture mode. Hence, the
SRAM Read and Write cycle descriptions and diagrams shown in the “Static RAM Cycles – Shared
Memory Architecture” section apply.
Transmit Operation
The transmit operation and features of the PCnet-ISA
II controller are controlled by programmable options.
Transmit Function Programming
Automatic transmit features, such as retry on collision,
FCS generation/transmission, and pad field insertion,
can all be programmed to provide flexibility in the
(re-)transmission of messages.
Disable retry on collision (DRTY) is controlled by the
DRTY bit of the Mode register (CSR15) in the initialization block.
Automatic pad field insertion is controlled by the
APAD_XMT bit in CSR4. If APAD_XMT is set, automatic pad field insertion is enabled, the DXMTFCS feature is over-ridden, and the 4-byte FCS will be added to
the transmitted frame unconditionally. If APAD_XMT is
cleared, no pad field insertion will take place and runt
packet transmission is possible.
The disable FCS generation/transmission feature can
be programmed dynamically on a frame by frame
basis. See the ADD_FCS description of TMD1.
T r ansmit FIFO W atermark (XMTFW in CSR80) sets the
point at which the BMU (Buffer Management Unit)
requests more data from the transmit buffers for the
FIFO. This point is based upon how many 16-bit bus
transfers (2 bytes) could be performed to the existing
empty space in the transmit FIFO.
Transmit Star t Point (XMTSP in CSR80) sets the point
when the transmitter actually tries to go out on the
media. This point is based upon the number of bytes
written to the transmit FIFO for the current frame.
When the entire frame is in the FIFO, attempts at transmission of preamble will commence regardless of the
value in XMTSP. The default value of XMTSP is 10b,
meaning 64 bytes full.
Automatic Pad Generation
T ransmit fr ames can be automatically padded to extend
them to 64 data bytes (excluding preamble). This
allows the minimum frame size of 64 bytes (512 bits) f or
802.3/Ethernet to be guaranteed with no software intervention from the host/controlling process. Setting the
APAD_XMT bit in CSR4 enables the automatic padding feature. The pad is placed between the LLC data
field and FCS field in the 802.3 frame. FCS is always
added if the frame is padded, regardless of the state of
DXMTFCS. The tr ansmit frame will be padded by b ytes
with the value of 00h. The default value of APAD_XMT
is 0, and this will disable auto pad generation after
RESET.
It is the responsibility of upper layer software to correctly define the actual length field contained in the
message to correspond to the total number of LLC
Data bytes encapsulated in the packet (length field as
defined in the IEEE 802.3 standard). The length value
contained in the message is not used by the PCnet-ISA
II controller to compute the actual number of pad bytes
80Am79C961A
PRELIMINARY
to be inserted. The PCnet-ISA II controller will append
pad bytes dependent on the actual number of bits
transmitted onto the network. Once the last data byte
of the frame has completed prior to appending the
FCS, the PCnet-ISA II controller will check to ensure
that 544 bits have been transmitted. If not, pad bytes
are added to extend the frame size to this value, and
the FCS is then added.
The 544 bit count is derived from the following:
Minimum frame size (excluding preamble,
including FCS)64 bytes512 bits
Preamble/SFD size8 bytes64 bits
FCS size4 bytes32 bits
To be classed as a minimum-size frame at the receiver,
the transmitted frame must contain:
Preamble + (Min Frame Size + FCS) bits
At the point that FCS is to be appended, the transmitted
frame should contain:
Preamble + (Min Frame Size - FCS) bits
64+(512- 32) bits
A minimum-length transmit frame from the PCnet-ISA
II controller will, therefore, be 576 bits after the FCS is
appended.
Transmit FCS Generation
Automatic generation and transmission of FCS for a
transmit frame depends on the value of DXMTFCS bit
in CSR15. When DXMTFCS = 0 the transmitter will
generate and append the FCS to the transmitted frame.
If the automatic padding feature is invoked
(APAD_XMT is SET in CSR4), the FCS will be
appended by the PCnet-ISA II controller regardless of
the state of DXMTFCS. Note that the calculated FCS is
transmitted most-significant bit first. The default value
of DXMTFCS is 0 after RESET.
Transmit Exception Conditions
Exception conditions for frame transmission fall into
two distinct categories; those which are the result of
normal network operation, and those which occur due
to abnormal network and/or host related events.
Normal events which may occur and which are handled
autonomously by the PCnet-ISA II controller are basically collisions within the slot time with automatic retry.
The PCnet-ISA II controller will ensure that collisions
which occur within 512 bit times from the start of transmission (including preamble) will be automatically
retried with no host intervention. The tr ansmit FIFO ensures this by guaranteeing that data contained within
the FIFO will not be overwritten until at least 64 bytes
(512 bits) of data have been successfully transmitted
onto the network.
If 16 total attempts (initial attempt plus 15 retries) fail,
the PCnet-ISA II controller sets the RTR Y bit in the current transmit TDTE in host memory (TMD2), gives up
ownership (sets the OWN bit to zero) for this packet,
and processes the next packet in the transmit ring for
transmission.
Preamble
1010....1010
56
Bits
SYNC
10101011
8
Bits
Dest.
ADDR
6
Bytes
ISO 8802-3 (IEEE/ANSI 802.3) Data Frame
SRCE.
ADDR.
6
Bytes
Length
2
Bytes
Data
Am79C961A81
LLC
PadFCS
4
Bytes
46-1500
Bytes
19364A-16
PRELIMINARY
Abnormal network conditions include:
■ Loss of carrier
■ Late collision
■ SQE Test Error (Does not apply to 10BASE-T port.)
These should not occur on a correctly configured 802.3
network, and will be reported if they do.
When an error occurs in the middle of a multi-buffer
frame transmission, the error status will be written in
the current descriptor. The OWN bit(s) in the subsequent descriptor(s) will be reset until the STP (the next
frame) is found.
Loss of Carrier
A loss of carrier condition will be reported if the
PCnet-ISA II controller cannot observe receive activity
while it is transmitting on the AUI por t. After the
PCnet-ISA II controller initiates a transmission, it will
expect to see data “looped back” on the DI± pair. This
will internally generate a “carrier sense,” indicating that
the integrity of the data path to and from the MAU is
intact, and that the MAU is operating correctly. This
“carrier sense” signal must be asserted before the end
of the transmission. If “carrier sense” does not become
active in response to the data transmission, or
becomes inactive before the end of transmission, the
loss of carrier (LCAR) error bit will be set in TMD2 after
the frame has been transmitted. The frame will not be
re-tried on the basis of an LCAR error. In 10BASE-T
mode LCAR will indicate that Jabber or Link Fail state
has occurred.
Late Collision
A late collision will be reported if a collision condition
occurs after one slot time (512 bit times) after the transmit process was initiated (first bit of preamble commenced). The PCnet-ISA II controller will abandon the
transmit process for the particular frame, set Late Collision (LCOL) in the associated TMD3, and process the
next transmit frame in the ring. Frames experiencing a
late collision will not be re-tried. Recovery from this
condition must be performed by upper-layer software.
SQE Test Error
During the inter packet gap time following the completion of a transmitted message, the AUI CI± pair is
asserted by some transceivers as a self-test. The integral Manchester Encoder/Decoder will expect the SQE
Test Message (nominal 10 MHz sequence) to be
returned via the CI± pair within a 40 network bit time
period after DI± pair goes inactive. If the CI± inputs are
not asserted within the 40 network bit time period following the completion of transmission, then the
PCnet-ISA II controller will set the CERR bit in CSR0.
CERR will be asserted in 10BASE-T mode after transmit if T-MAU is in Link Fail state. CERR will never cause
INTR to be activated. It will, how e ver, set the ERR bit in
CSR0.
Host related transmit exception conditions include
BUFF and UFLO as described in the Transmit Descriptor section.
Receive Operation
The receive operation and features of the PCnet-ISA II
controller are controlled by programmable options.
Receive Function Programming
Automatic pad field stripping is enabled by setting the
ASTRP_RCV bit in CSR4; this can provide flexibility in
the reception of messages using the 802.3 frame format.
All receive frames can be accepted by setting the
PROM bit in CSR15. When PROM is set, the
PCnet-ISA II controller will attempt to receive all messages, subject to minimum frame enforcement. Promiscuous mode overrides the effect of the Disable
Receive Broadcast bit on receiving broadcast frames.
The point at which the BMU will start to transfer data
from the receive FIFO to buff er memory is controlled by
the RCVFW bits in CSR80. The default established
during reset is 10b, which sets the threshold flag at 64
bytes empty.
Automatic Pad Stripping
During reception of an 802.3 frame the pad field can be
stripped automatically . ASTRP_RCV (bit 10 in CSR4) =
1 enables the automatic pad stripping feature. The pad
field will be stripped before the frame is passed to the
FIFO, thus preser ving FIFO space for additional
frames. The FCS field will also be stripped, since it is
computed at the transmitting station based on the data
and pad field characters, and will be invalid for a
receive frame that has had the pad characters stripped.
The number of bytes to be stripped is calculated from
the embedded length field (as defined in the IEEE
802.3 definition) contained in the frame. The length
indicates the actual number of LLC data bytes contained in the message. Any received frame which contains a length field less than 46 bytes will have the pad
field stripped (if ASTRP_RCV is set). Receive frames
which have a length field of 46 bytes or greater will be
passed to the host unmodified.
Since any valid Ethernet Type field value will always be
greater than a normal 802.3 Length field (≥46), the
PCnet-ISA II controller will not attempt to strip valid
Ethernet frames.
Note that for some network protocols the value passed
in the Ethernet Type and/or 802.3 Length field is not
compliant with either standard and may cause problems.
The diagram below shows the byte/bit ordering of the
received length field for an 802.3 compatible frame
format.
82Am79C961A
56
Bits
8
Bits
PRELIMINARY
6
Bytes
6
Bytes
Bytes
46–1500
2
Bytes
4
Bytes
Preamble
1010....1010
Start of Packet
at Time= 0
Increasing Time
SYNCH
10101011
Dest.
ADDR.
IEEE/ANSI 802.3 Frame and Length Field Transmission Order
Receive FCS Checking
Reception and checking of the received FCS is performed automatically by the PCnet-ISA II controller.
Note that if the Automatic Pad Str ipping feature is
enabled, the received FCS will be verified against the
value computed for the incoming bit stream including
pad characters, but it will not be passed to the host. If
a FCS error is detected, this will be reported by the
CRC bit in RMD1.
Receive Exception Conditions
Exception conditions for frame reception fall into two
distinct categories; those which are the result of normal
network operation, and those which occur due to
abnormal network and/or host related events.
Normal events which may occur and which are handled
autonomously by the PCnet-ISA II controller are basically collisions within the slot time and automatic runt
packet rejection. The PCnet-ISA II controller will ensure
that collisions which occur within 512 bit times from the
Srce.
ADDR.
Bit
0
Most
Significant
Byte
LengthLLC
DATA
1–1500
Bytes
Bit 7Bit
0
Least
Significant
Byte
PadFCS
45–0
Bytes
Bit
7
start of reception (excluding preamble) will be automatically deleted from the receive FIFO with no host intervention. The receive FIFO will delete any frame which
is composed of fewer than 64 bytes provided that the
Runt Packet Accept (RPA bit in CSR124) feature has
not been enabled. This criteria will be met regardless of
whether the receive frame was the first (or only) frame
in the FIFO or if the receive frame was queued behind
a previously received message.
Abnormal network conditions include:
■ FCS errors
■ Late collision
These should not occur on a correctly configured 802.3
network and will be reported if they do.
Host related receive exception conditions include
MISS, BUFF, and OFLO. These are descr ibed in the
Receive Descriptor section.
19364A-17
Am79C961A83
PRELIMINARY
MAGIC PACKET™ OPERATION
In the Magic Pack et mode, PCnet-ISA II completes any
transmit and receive operations in progress, suspends
normal activity, and enters into a state where only a
Magic Pack et could be detected. A Magic P ac k et frame
is a frame that contains a data sequence which repeats
the Physical Address (PADR[47:00]) at least sixteen
times frame sequentially, with bit[00] received first. In
Magic Pack et suspend mode, the PCnet-ISA II remains
powered up. Slave accesses to the PCnet-ISA II are
still possible, the same as any other mode. All of the
received packets are flushed from the receiv e FIFO . An
LED and/or interrupt pin could be activated, indicating
the receive of a Magic Packet frame. This indication
could be used for a variety of management tasks.
Magic Packet Mode Activation
This mode can be enabled by either software or external hardware means, but in either case, the MP_MODE
bit (CSR5, bit 1) must be set first.
Hardware Activation. This is done by driving the
SLEEP
the PCnet-ISA II to normal operation.
Software Activation. This is done by setting the
MP_ENBL bit (CSR5, bit 2). Resetting this bit will return
the PCnet-ISA II to normal operation.
Magic Packet Receive Indicators
The reception of a Magic Pack et can be indicated either
through one of the LEDs 1, 2 or 3, and/or the activation
of the interrupt pin. MP_INT bit (CSR5, bit 4) will also
be set upon the receive of the Magic Packet.
LED Indication. Either one of the LEDs 1, 2, or 3 could
be activated by the receive of the Magic Packet. The
“Magic Packet enable” bit (bit 9) in the ISACSR 5, 6 or
7 should be set to enable this feature. Note that the
polarity of the LED2 could be controlled by the
LEDXOR bit (ISACSR6, bit 14). The LED could be
deactivated by setting the STOP bit or resetting the
MP_ENBL bit (CSR5, bit 2).
Interrupt Indication. Interrupt pin could be activated
by the receive of the Magic P ack et. The MP_I_ENBL bit
(CSR5, bit 3) and IENA bit (CSR0, bit 6) should be set
to enable this feature.
pin low. Deasserting the SLEEP pin will return
Loopback Operation
Loopback is a mode of operation intended for system
diagnostics. In this mode, the transmitter and receiver
are both operating at the same time so that the
controller receives its own transmissions. The controller provides two types of internal loopback and three
types of external loopback. In internal loopback mode,
the transmitted data can be looped back to the receiver
at one of two places inside the controller without actually transmitting any data to the external network. The
receiver will move the receiv ed data to the next receive
buffer, where it can be examined by software. Alternatively, external loopback causes transmissions to go
off-chip. For the AUI port, frame transmission occurs
normally and assumes that an external MAU will loop
the frame back to the chip. For the 10BASE-T port, two
external loopback options are available, both of which
require a valid link pass state and both of which transmit data frames at the RJ45 interface. Selection of
these modes is defined by the TMAU_LOOPE bit in
ISACSR2. One option loops the data frame bac k inside
the chip, and is compatible with a ‘live’ network. The
other option requires an external device (such as a
‘loopback plug’) to loop the data back to the chip, a
function normally not available on a 10BASE-T
network.
The PCnet-ISA II chip has two dedicated FCS generators, eliminating the traditional LANCE limitations on
loopback FCS operation. The receive FCS generation
logic is always enabled. The transmit FCS generation
logic can be disabled (to emulate LANCE type loopback operation) by setting the DXMTFCS bit in the
Mode register (CSR15). In this configuration, software
must generate the FCS and append the four FCS bytes
to the transmit frame data.
The loopback facilities of the MAC Engine allow full
operation to be verified without disturbance to the network. Loopback operation is also affected by the state
of the Loopback Control bits (LOOP, MENDECL, and
INTL) in CSR15. This affects whether the internal
MENDEC is considered part of the internal or external
loop- backpath.
The receive FCS generation logic in the PCnet-ISA II
chip is used for multicast address detection. Since this
FCS logic is always enabled, there are no restrictions
to the use of multicast addressing while in loopback
mode.
When performing an internal loopback, no frame will be
transmitted to the network. However, when the
PCnet-ISA II controller is configured for internal loopback the receiver will not be able to detect network
traffic. External loopback tests will tr ansmit frames onto
the network if the AUI port is selected, and the
PCnet-ISA II controller will receive network traffic while
configured for external loopback when the AUI por t is
selected. Runt Packet Accept is automatically enabled
when any loopback mode is invoked.
Loopback mode can be performed with any frame size .
Runt Packet Accept is internally enabled (RPA bit in
CSR124 is not affected) when any loopback mode is
invoked. This is to be backwards compatible to the
LANCE (Am7990) software.
LEDs
The PCnet-ISA II controller’s LED control logic allows
programming of the status signals, which are display ed
84Am79C961A
PRELIMINARY
on 3 LED outputs. One LED (LED0) is dedicated to displaying 10BASE-T Link Status. The status signals
available are Collision, J abber , Receive, Receiv e Polarity, Transmit, Receive Address Match, and Full Duplex
Link Status. If more than one status signal is enabled,
they are ORed together. An optional pulse stretcher is
available for each programmable output. This allows
emulation of the TPEX (Am79C98) and TPEX
(Am79C100) LED outputs.
SignalBehavior
COLActive during collision activity on the network
FDLS
JAB
LNKST
RCVActive while receiving data
RVPOL
RCVADDM Active during Receive with Address Match
XMTActive while transmitting data
Active when Full Duplex operation is enabled
and functioning on the selected network port
Active when the PCnet-ISA II is jabbering on
the network
Active during Link OK Not active during Link
Down
Active during receive polarity is OK Not active
during reverse receive polarity
Each status signal is ANDed with its corresponding
enable signal. The enabled status signals run to a common OR gate:
+
FDLS
FDLSE
RCVM
RCVM E
XMT
XMT E
RVPOL
RVPOL E
RCV
RCV E
JAB
JAB E
COL
COL E
RCVADDM
RCVADDE
AND
AND
AND
AND
AND
AND
AND
AND
LED Control Logic
OR
To
Pulse
Stretcher
19364A-18
The output from the OR gate is run through a pulse
stretcher, which consists of a 3-bit shift register clock ed
at 38 Hz. The data input of the shift register is at logic
0. The OR gate output asynchronously sets all three
bits of the shift register when its output goes active. The
output of the shift register controls the associated LEDx
pin. Thus, the pulse stretcher provides an LED output
of 52 ms to 78 ms.
Refer to the section “ISA Bus Configuration Registers”
for information on LED control via the ISACSRs.
Am79C961A85