AMD Advanced Micro Devices AM29LV001BT-90FI, AM29LV001BT-90FEB, AM29LV001BT-90FE, AM29LV001BT-90FCB, AM29LV001BT-90FC Datasheet

...
PRELIMINARY
Am29LV001B
1 Megabit (128 K x 8-Bit) CMOS 3.0 Volt-only Boot Sec tor Flash Memory

DISTINCTIVE CHARACTERISTICS

— Full voltage range: 2.7 to 3. 6 volt read and write
operations for battery-powered applications
— Regulated voltage r ange: 3.0 to 3.6 v olt read and
write operations and for compatibility with high performance 3.3 volt microprocessors
Manufactured on 0.35 µm process technology
High performance
— Full voltage range: ac cess times as f ast as 55 ns — Regulated voltage range: access times as fast
as 45 ns
Ultra low power consumption (typical values at
5 MHz)
— 200 nA Automatic Sleep mode current — 200 nA standby mode current — 7 mA read current — 15 mA program/erase current
Flexible sector architecture
— One 8 Kbyte, two 4 Kbyte, and seven 16 Kbyte — Supports full chip erase — Sector Protection features:
Hardware method of loc king a sector to prevent any program or erase operat ions within that sector
Sectors can be locked in-system or via programming equipment
T emporary Sector Unprotect feat ure allows code changes in previously locked sectors
Unlock Bypass Mode Program Co mmand
— Reduces overall programming time when
issuing multiple program command sequences
Top or bottom boot block configurations
available
Embedded Al gorithms
— Embedded Erase algorithm automatically
preprograms and erases the entire chip or any combination of designated sectors
— Embedded Program algorithm automatically
writes and verifies data at specified addresses
Minimum 1,000,000 write cycle guarantee per
sector
Package option
— 32-pin TSOP — 32-pin PLCC
Compatibility with JEDEC standards
— Pinout and software compatible with single-
power supply Flash
— Superior inadvertent write protection
Data# Polling and toggle bits
— Provides a software method of detecting
program or erase operation completion
Erase Suspend/Erase Resume
— Supports reading data from or programming
data to a sector that is not being erased
Hardware reset pin (RESET#)
— Hardware method for resetting the device to
reading array data
Publication# 21557 Rev: C Amendment/0 Issue Date: April 1998
PRELIMINARY

GENERAL DESCRIPTION

The Am29LV001B is a 1 Mbit, 3.0 Volt-only Flash memory devic e organized as 131,072 bytes. T he Am29LV001B has a boot sector architecture.
The device is offered in 32-pin PLCC and 32-pin TSOP
packages. The byte-wide (x8) data appears on DQ7– DQ0. All read, erase, and program operations are accomplished using only a single power supply. The device can also be programmed in s tandard EPROM programmers.
The standard Am29LV001B offers access times of 45, 55, 70, and 90 ns, allowing high speed m icroproces­sors to operate without wait states. To eliminate bus contention, the device has separate chip enab le (CE#), write enable (WE#) and output enable (OE#) controls.
The device requires only a single power supply (2.7 V–3.6V) for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations.
The Am29LV001B is entirely command set compatible with the JEDEC single-power-supply Flash standard. Commands are written to t he command reg­ister using standard microprocessor write timings. Reg­ister contents ser ve as input to an internal state­machine that controls the erase and programming cir­cuitry. Write cycles also internally latch addresses and data needed for the programming and erase op era­tions. Reading data out of the device is similar to reading from other Flash or EPROM devices.
Device programming occurs by executing the program command sequence. This initiates the Embedded Program algorithm—an internal algorithm that auto­matically times the program pulse widths and verifies proper cell margin. The Unlock Bypass mode facili­tates faster programming times by requir ing only two write cycles to program data instead of four.
Device erasure occurs by executing the erase com­mand sequence. This initiates the Embedded Erase algorithm—an in ternal algorithm that autom atically preprograms the array (if it is not already prog rammed) before e xecuting the erase operation. During erase, the
device automatically tim es the erase pulse widths and verifies proper cell margin.
The host system can detect whether a program or erase operation is complete by reading the DQ7 (Data# Polling) and DQ6 (toggle) status bits. After a program or erase cycle has been completed, the de vice is ready to read array data or accept another command.
The sector erase ar chitecture allo ws memo ry secto rs to be erased and reprogrammed without affecting the data contents of other sectors. The device is fully erased when shipped from the factory.
Hardware data protection measur es include a low
detector that automatically in hibits write opera-
V
CC
tions during power transitions. The hardware sector protection feature disables both program and erase
operations in any combination of the sectors of mem­ory. This can be achieved in-system or via program­ming equipment.
The Erase Suspend feature enables the user to put erase on hold for any period of time to read data from, or program data to, any sector that is not selected for erasure. True background erase can thus be achie ved.
The hardware RESET# pi n terminates any operation in progress and resets the internal state machine to reading array dat a. The RESET# pin ma y be tied to the system reset circuitry. A system reset would thus also reset the device, enabling the system microprocessor to read the boot-up firmware from the Flash memory.
The device off ers two power-sa ving f eatures. When ad­dresses have been stable for a specified amount of time, the device enters the automatic sleep m ode. The system can also place the de vice into the standby mode. Power consumption is greatly reduced in both these modes.
AMD’s Flash technology combines years of Flash memory manufacturing experience to produce the highest levels of quality, reliability and cost effective­ness. The device electrically erases all bi t s w i th i n a sector simultaneously via Fowler-Nordheim tun­neling. The data is programmed using hot electron injection.
Am29LV001B 2
PRELIMINARY

PRODUCT SELECTOR GUIDE

Family Part Number Am29LV001B
Speed Options
Max access time, ns (t Max CE# access time, ns (tCE) 45 55 70 90 Max OE# access time, ns (tOE) 25 30 30 35
Regulated Voltage Range: VCC =3.0–3.6 V -45R
Full Voltage Range: VCC = 2.7–3.6 V -55 -70 -90
) 45 55 70 90
ACC
Note: See “AC Characteristics” for full specifications.

BLOCK DIAGRAM

DQ0
DQ7
V
RESET#
WE#
CC
V
SS
CE#
OE#
State
Control
Command
Register
PGM Voltage
Generator
Sector Switches
Erase Voltage
Generator
Chip Enable
Output Enable
Logic
STB
Input/Output
Buffers
Data
Latch
A0–A16
VCC Detector
Timer
STB
Address Latch
Y-Decoder
X-Decoder
Y-Gating
Cell Matrix
21557C-1
3 Am29LV001B

CONNECTION DIAGRAMS

PRELIMINARY
A11
A9
A8 A13 A14
NC
WE#
V
CC
RESET#
A16 A15 A12
A7
A6
A5
A4
OE#
A10
CE#
DQ7 DQ6 DQ5 DQ4
DQ3
V
DQ2 DQ1 DQ0
SS
A0 A1 A2 A3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
32-Pin Standard TSOP
32-Pin Reverse TSOP
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
OE# A10 CE#
DQ7 DQ6 DQ5 DQ4 DQ3 V
SS
DQ2 DQ1 DQ0 A0 A1 A2 A3
A11 A9 A8 A13 A14 NC WE# V
CC
RESET# A16 A15 A12 A7 A6 A5 A4
A7 A6 A5
A4 A3 A2 A1 A0
DQ0
CC
WE#
RESET#
5 6
7
8 9 10
11 12 13
14
A12
A15
Am29LV001
15
DQ1
DQ2
A16
13130234
PLCC
17
SS
V
DQ3
32
18
V
19 2016
DQ4
DQ5
NC
29 28 27
26 25 24 23 22 21
DQ6
A14 A13
A8
A9 A11 OE#
A10 CE# DQ7
Am29LV001B 4
21557C-2
PRELIMINARY

PIN CONFIGURATION

A0–A16 = 17 addresses DQ0–DQ7 = 8 data inputs/outputs CE# = Chip enable OE# = Output enable WE# = Write enable RESET# = Hardware reset pin, active low
= 3.0 volt-only single power supply
V
CC
V
SS
NC = Pin not connected internally
(see Product Selector Guide for speed options and voltage supply toleranc es)
= Device ground

LOGIC SYMBOL

17
A0–A16
CE# OE#
WE# RESET#
8
DQ0–DQ7
21557C-3
5 Am29LV001B
PRELIMINARY
ORDERING INFORMATION Standard Pr od ucts
AMD standard products are available in several packages and operating ranges. The order number (Valid Combi­nation) is formed by a combination of the elements below.
CE-45RAm29LV001B T
OPTIONAL PROCESSING
Blank = Standard Processing B = Burn-in (Contact an AMD representative for more information)
TEMPERATURE RANGE
C=Commercial (0°C to +70°C) I = Industrial (–40°C to +85°C) E = Extended (–55°C to +125°C)
PACKAGE TYPE
E = 32-Pin Thin Small Outline Package (TSOP)
Standard Pinout (TS 032)
F = 32-Pin Thin Small Outline Package (TSOP)
Reverse Pinout (TSR032)
J = 32-Pin Rectangular Plastic Leaded Chip
Carrier (PL 032)
Am29LV001BT-45R, Am29LV001BB-45R,
Am29LV 00 1B T-55, Am29LV 00 1B B-5 5,
Am29LV 00 1B T-70, Am29LV 00 1B B-7 0,
Am29LV 00 1B T-90, Am29LV 00 1B B-9 0,
Valid Combinations
DEVICE NUMBER/DESCRIPTION
Am29LV001B 1 Megabit (128 K x 8-Bit) CMOS Flash Memory
3.0 Volt-only Read, Program, and Erase
EC, FC, JC
EC, EI, EE, FC, FI, FE,
JC, JI, JE
SPEED OPTION
See Product Selector Guide and Valid Combinations
BOOT CODE SECTOR ARCHITECTURE
T = Top Sector B = Bottom Sector
Valid Combinations
Valid Combinations list configurations planned to be sup­ported in volume for this device. Consult the local AMD sales office to confirm availability of specific valid combinations and to check on newly released combinations.
Am29LV001B 6
PRELIMINARY

DEVICE BUS OPERATIONS

This section describes the requirements and use of the device bus operations, which are initiated through the internal c ommand register. The command register it­self does not occupy any addressable memory loca­tion. The register is composed of l atches that store the commands, along with the address and data informa­tion needed to execute the command. The contents of
Table 1. Am29LV001B Device Bus Operations
Operation CE# OE# WE# RESET# Addresses (Note 1) DQ0–DQ7
Read L L H H A Write L H L H A Standby VCC ± 0.3 V X X VCC ± 0.3 V X High-Z Output Disable L H H H X High-Z Reset X X X L X High-Z
Sector Protect (Note 2) L H L V
Sector Unprotect (Note 2) L H L V Temporary Sector Unprotect X X X V
Legend:
L = Logic Low = V
Notes:
1. Addresses are A16–A0.
2. The in-system method of sector protection/unprotection is available. Sector protection/unprotection can be implemented by using programming equipment. See the “Sector Protection/Unprotection” section.
, H = Logic High = VIH, VID = 12.0 ± 0.5 V, X = Don’t Care, AIN = Address In, DIN = Data In, D
IL
the register serve as inputs to the internal state ma­chine. The state machine outputs dictate the function of the device. Table 1 lists the device bus operations, the inputs and control lev els t he y requ ire , and t he resulting output. The following subsections describe each of these operations in further detail.
IN IN
ID
ID
ID
Sector Address, A6 = L,
A1 = H, A0 = L
Sector Address, A6 = H,
A1 = H, A0 = L
A
IN
D
D
IN
D
IN
= Data Out
OUT
OUT
D
, D
, D D
IN
OUT
OUT
IN

Requirements for Reading Array Data

To read array data from the outputs, the system must drive the CE# and OE# pins to V control and selects the device. OE# is the output con­trol and gates arra y data to the output pins . WE# should remain at V
.
IH
The internal state machine is set for reading array data upon device power-up, or after a hardware reset. This ensures that no spurious alteration of the memory con­tent occurs dur ing the power transi tion. No com mand is necessary in this mode to o btai n array data. Stand­ard microprocessor read cycles that assert valid ad­dresses on the device address inputs produce valid data on the device data outputs. The device remains enabled for read access until the command register contents are altered.
See “Reading Array Data” for more information. Refer to the AC Read Operations table for timing specifica­tions and to Figure 13 for the timing diagram. I
the DC Characteristics table represents the active c ur­rent specification for reading array data.
. CE# is the power
IL
CC1
in

Writing Commands/Command Sequences

To write a command or command sequence (which in­cludes programming data to the device and erasing sectors of memory), the system must drive WE# and CE# to V
The device f eatures an Unlock Bypass mode to facili- tate faster programming. Once the device enters the Unlock Bypass mode, only two write cycles are re­quired to program a byte, instead of four. The “Byte Program Command Sequence” section has details on programming data to the device using both standard and Unlock Bypass command sequences.
An erase operation can erase one sect or, multiple sec­tors, or the entire device. Table 2 indicate the address space that each sector occupies. A “sector address” consists of the address bits required to uniquely select a sector. The “Command Definitions” section has de­tails on erasing a sector or the entire chip, or suspend­ing/resuming the erase operation.
After the system writes the autoselect command se­quence, the device enters the autoselect mode. The system can then read autoselect codes from the inter-
, and OE# to VIH.
IL
7 Am29LV001B
PRELIMINARY
nal register (which is separate from the memory array)
on DQ7–DQ0. Standard read cycle timings apply in this mode. Refer to the Autoselect Mode and Autoselect Command Sequence sections for more information.
in the DC Characteristics table represents the ac-
I
CC2
tive current specification for the w rite mode. The “AC Characteristics” section contains timing specification tables and timing diagrams for w r ite operations.

Program and Erase Operation Status

During an erase or program operation, the system ma y check the status of the operation by reading the status bits on DQ7–DQ0. Standard read cycle timings and I
CC
read specifications apply. Refer to “Write Operation Status” for more information, and to “AC Characteris­tics” for timing diagrams.

Standby Mode

When the system is not reading or writing to the de­vice, it can place the device in the standby mode. In this mode, current consumption is greatly reduced, and the outputs ar e placed in the high impedance state, independent of the OE# input.
The device enters the CMOS standby mode when the CE# and RESET# pin s are both held at V (Note that this is a more restricted voltage range than
.) If CE# and RESET# ar e held a t VIH, but not within
V
IH
± 0.3 V, the device will be in the standb y mode, but
V
CC
the standby current will be greater. The device requires standard access time (t
) for read access when the
CE
device is in either of these standby modes, before it is ready to read data.
The device also enters the standb y mode when the RE­SET# pin is driven low. Refer to the next section, RE­SET#: Hardware Reset Pin.
If the device is deselected during erasure or program­ming, the device draws active current until the operation is completed.
CC
± 0.3 V.

Automatic Sleep Mode

The automatic sleep mode minimizes Flash device energy consumption. The de vice automatically enables this mode when addresses remain stable f or t
ACC
+ 30 ns. The automatic sleep mode is independent of the CE#, WE#, and OE# control signals. Standard addres s access timings provide new data when addresses are changed. While in sleep mode, output data is latched and always available to the system. I
CC5
in the DC Characteristics table represents the automatic sleep mode current specification.

RESET#: Hardware Reset Pin

The RESET# pin provides a hardw are method of reset­ting the device to reading array data. When the RE­SET# pin is driven low for at least a period of t device immediately terminates any operation in progress, tristates all output pins, and ignores all read/write commands for the duration of the RESET# pulse. The device also resets the inter nal state ma­chine to reading array data. The operation that was in­terrupted should be reinitiated once the device is ready to accept another command sequence, to ensure data integrity.
Current is reduced for the duration of the RESET# pulse. When RESET# is held at V draws CMOS standby c urrent (I
but not within VSS±0.3 V, the standby current will
at V
IL
±0.3 V, the device
SS
). If RESET# is held
CC4
be greater. The RESET# pin may be tied to the system reset cir-
cuitry. A system reset would thus also reset the Flash memory, enabling the system to read the boot-up firmware from the Flash memory.The system may use the RESET# pin to force the device into the standby mode. Refer to the “ Standby Mode” section for more in­formation.
Refer to the AC Characteristics tables for RESET# pa­rameters and to Figure 14 for the timing diagram.
RP
, the
in the DC Characteristics table represents the
I
CC3
standby current specification.

Output Disable Mode

When the OE# input is at VIH, output from the device is disabled. The output pins are placed in t he high imped­ance state.
Am29LV001B 8
PRELIMINARY
Table 2. Am29LV001B Top Boot Sector Architecture
Sector Size
Sector A16 A15 A14 A13 A12
SA0 0 0 0 X X 16 Kbytes 00000h–03FFFh SA1 0 0 1 X X 16 Kbytes 04000h–07FFFh SA2 0 1 0 X X 16 Kbytes 08000h–0BFFFh SA3 0 1 1 X X 16 Kbytes 0C000h–0FFFFh SA4 1 0 0 X X 16 Kbytes 10000h–13FFFh SA5 1 0 1 X X 16 Kbytes 14000h–17FFFh SA6 1 1 0 X X 16 Kbytes 18000h–1BFFFh SA7 1 1 1 0 0 4 Kbytes 1C000h–1CFFFh SA8 1 1 1 0 1 4 Kbytes 1D000h–1DFFFh SA9 1 1 1 1 X 8 Kbytes 1E000h–1FFFFh
(Kbytes)
Address Range
(in hexadecimal)
Table 3. Am29LV001B Bottom Boot Sector Architecture
Sector Size
Sector A16 A15 A14 A13 A12
SA0 0 0 0 0 X 8 Kbytes 00000h–01FFFh SA1 0 0 0 1 0 4 Kbytes 02000h–02FFFh SA2 0 0 0 1 1 4 Kbytes 03000h–03FFFh SA3 0 0 1 X X 16 Kbytes 04000h–07FFFh SA4 0 1 0 X X 16 Kbytes 08000h–0BFFFh SA5 0 1 1 X X 16 Kbytes 0C000h–0FFFFh SA6 1 0 0 X X 16 Kbytes 10000h–13FFFh SA7 1 0 1 X X 16 Kbytes 14000h–17FFFh SA8 1 1 0 X X 16 Kbytes 18000h–1BFFFh SA9 1 1 1 X X 16 Kbytes 1C000h–1FFFFh
(Kbytes)
Address Range (in
hexadecimal)
9 Am29LV001B
PRELIMINARY

Autoselect Mode

The autoselect mode provides manufacturer and de­vice identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This mode is primarily intended for progr amming equipment to automatically match a device to be progr ammed with its correspondi ng programming al gorithm. However, the autoselect codes can also be accessed in-system through the command register.
When using programming equipment, the autoselect mode requires V A9. Address pins A6, A1, and A0 must be as shown in
(11.5 V to 12.5 V) on address pin
ID
Table 4. In addition, when verifying sector protection, the sector addres s must appear on the appropriate highest order address bits (see Table 2). Table 4 s hows the remaining address bits that are don’t c are. When all necessary bits have been set as required, the program­ming equipment may then read the corresponding identifier code on DQ7-DQ0.
To access the autoselect codes in-system, the host system can issue the autoselect command via the command register, as shown in Table 5. This method does not require V details on using the autoselect mode.
Table 4. Am29LV001B Autoselect Codes
A16
A11
to
to
Description CE# OE# WE#
Manufacturer ID: AMD L L H X X V Device ID: Am29LV001B T
(Top Boot Block) Device ID: Am29LV001B B
(Bottom Boot Block)
LLHXXV
LLHXXVIDXLXLH 6Dh
A12
A10 A9
. See “Command Definitions” for
ID
A8
to
A7 A6
XLXLL 01h
ID
XLXLH EDh
ID
A5
to
A2 A1 A0
DQ7
to
DQ0
Sector Protection Verification L L H SA X V
L = Logic Low = VIL, H = Logic High = VIH, SA = Sector Address, X = Don’t care.

Sector Protection/Unprotection

The hardware sector protection feature disables both program and erase operations in any sect or. The hard­ware sector unprotection feature re-enables both pro­gram and erase operations in previously protected sectors. Sector protection/unprotecti on can be imple­mented via two methods.
The primary method requires V only, and can be implemented either in-system or via programming equipment. Figure 1 shows the algo­rithms and Figure 21 shows the timing diagram. This method uses standard m icroprocessor bus cycle tim­ing. For sector unprotect, all unprotec ted sectors must first be protected prior to the first sector unpro tect write cycle.
The alternate method intended on ly for programming equipment requires V
on address pin A9, OE#, and
ID
RESET#. This method is compatible with programmer
on the RESET# pin
ID
The device is shipped with all s ectors unprotected. AMD offers the option of programming and protecting sectors at its factory prior to shipping the device
through AMD’s ExpressFlash™ Servic e. Contact an AMD representative for details.
It is possible to determine whether a sector is protected or unprotected. See “Autoselect Mode” for details.

Temporary Sector Unprotect

This feature allows temporary unprotection of previ­ously protected sectors to change data in-system. The Sector Unprotect mode is activated by setting the RE­SET# pin to V sectors can be programmed or erased b y selecting the sector addresses. Once V SET# pin, all the previously protected sectors are protected again. Figure 2 shows the algorithm, and Figure 20 shows the tim ing diagrams, for this feature.
XLXHL
ID
routines written for earlier 3.0 volt-only AMD flash de­vices. Publication number 2 2134 contains fur ther de­tails; contact an AMD representati ve to r equest a cop y.
01h
(protected)
00h
(unprotected)
. During this mode, formerly protected
ID
is removed from the RE-
ID
Am29LV001B 10
PRELIMINARY
Temporary Sector
Unprotect Mode
Increment
PLSCNT
No
PLSCNT
= 25?
Yes
Device failed
Sector Protect
Algorithm
START
PLSCNT = 1
RESET# = V
Wait 1 µs
No
First Write
Cycle = 60h?
Set up sector
address
Sector Protect:
Write 60h to sector
address with
A6 = 0, A1 = 1,
A0 = 0
Wait 150 µs
Verify Sector
Protect: Write 40h
to sector address
with A6 = 0,
A1 = 1, A0 = 0
Read from
sector address
with A6 = 0,
A1 = 1, A0 = 0
No
Data = 01h?
Protect another
sector?
Remove V
from RESET#
Write reset
command
Sector Protect
complete
Yes
Yes
No
START
Protect all sectors:
The indicated portion
of the sector protect
ID
Reset
PLSCNT = 1
Yes
ID
algorithm must be
performed for all
unprotected sectors
prior to issuing the
first sector
unprotect address
Increment
PLSCNT
No
PLSCNT
= 1000?
Yes
Device failed
Sector Unprotect
PLSCNT = 1
RESET# = V
Wait 1 µs
First Write
Cycle = 60h?
No
All sectors protected?
Set up first sector
address
Sector Unprotect:
Write 60h to sector
address with
A6 = 1, A1 = 1,
A0 = 0
Wait 15 ms
Verify Sector
Unprotect: Write
40h to sector address with
A6 = 1, A1 = 1,
A0 = 0
Read from
sector address
with A6 = 1,
A1 = 1, A0 = 0
No
Data = 00h?
Last sector
verified?
Remove V
from RESET#
Yes
Yes
Yes
Yes
ID
No
Temporary Sector
Unprotect Mode
Set up
next sector
address
No
ID
Algorithm
Write reset
command
Figure 1. In-System Sector Protect/Unprotect Algorithms
11 Am29LV001B
Sector Unprotect
complete
21557C-4
PRELIMINARY
START
RESET# = V
(Note 1)
Perform Erase or
Program Operations
RESET# = V
Temporary Sector
Unprotect Completed
(Note 2)
Notes:
1. All protected sectors unprotected.
2. All previously protected sectors are protected once again.
ID
IH
21557C-5
Figure 2. Temporary Sector Unprotect Operation

Hardware Data Protection

The command sequence requirement of unlock cycles for programming or erasing provides data protection
against inadverten t writes (refer to Table 5 for com­mand definitions). In addition, the following hardwar e data protection mea sures prevent accidental erasure or programming, which might otherwise be caused by spurious system level signals during V
power-up and
CC
power-down transitions, or from system noise.
Low V
When V cept any write cycles. This protects data during V
Write Inhibit
CC
is less than V
CC
, the device does not ac-
LKO
CC
power-up and power-down. The command register and all internal program/erase circuits are disabled, and the device resets. Subsequent writes are ignored until V is greater than V
. The system must provide the
LKO
CC
proper signals to the control pins to prevent uninten­tional writes when V
is greater than V
CC
LKO
.

Write Pulse “Glitch” Protection

Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.

Logical Inhibit

Write cycles are inhibited by holding any one of OE# =
, CE# = VIH or WE# = VIH. To initiate a write cycle,
V
IL
CE# and WE# must be a logical zero while OE# is a logical one.
Power-Up W rite Inhibit
If WE# = CE# = V
and OE# = VIH during power up , the
IL
device does not accept commands on the rising edge of WE#. The internal state mac hine is automatically reset to reading array data on power-up.

COMMAND DEFINITIONS

Writing specific addre ss and data commands or se­quences into the command register initiates device op­erations. Table 5 de fines the valid register co mmand sequences. Writing incorrect address and data val- ues or writing them in the improper sequence resets the device to reading array data.
All addresses are latched on the falling edge of WE# or CE#, whichever happens later. All data is latched on the rising edge of WE# or CE#, whichever happens first. Refer to the appropriate timing diagrams in the
“AC Characteristics” section.

Reading Array Data

The device is automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is also ready to read array data after comp leting an Embe dded Program or Em­bedded Erase algorithm.
After the device accepts an Erase Suspend com­mand, the device enters the Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an address within erase-su spended sectors, the device outputs status data. After completing a programming o pera­tion in the Erase Suspend mode, the system may once again read array data with the same exception. See “Erase Suspend/Erase Resume Commands” for more information on this mode.
must
The system
issue the reset command to re-ena­ble the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the “Reset Com­mand” section, next.
See also “Requirements f o r Reading A rr ay Data” in the “Device Bus Operations” section for more infor mation. The Read Operations table provides the read parame­ters, and Figure 13 shows the timing diagram.
Am29LV001B 12