INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT
AND BUILT-IN UNITS
WM-FM-50-BG
SAFETY INFORMATION
WARNING
If the information in these instructions are
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS
Please read and carefully follow all of the instruction found in this manual. Please pay special
attention to the safety instructions provided in this manual. The instructions included here will assure
that you have many years of dependable and enjoyable service from your Amantii product.
IMPORTANT INSTRUCTIONS.......................................................................................................................3
UNPACKING AND TESTING APPLIANCE....................................................................................................4
REMOVING FRONT GLASS..................................................................................................................................... 6
MEDIA OPTIONS.........................................................................................................................................10
DECORATIVE MEDIA INSTALLATION........................................................................................................10
Read all instructions before installing or using this heater.
2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at
least 3 feet from the front of the heater; keep them away from sides and rear as well.
3. Always unplug heater when it’s not in use.
4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the
unit has been dropped or damaged in any way.
5. Do not use the heater outdoors.
6. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations.
Never place the heater where it may fall into a bathtub or other water containers.
7. Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or anything
else. Arrange the cord away from traffic areas where it could not be tripped over.
8. To disconnect the heater, turn the controls to "OFF" before removing the plug from the outlet.
9. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may
cause an electric shock, fire or damage to the heater.
10. To prevent a possible fire, do not block air intakes in any manner.
11. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint
or flammable liquids are used or stored.
12. Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock or injury to persons.
13. Avoid the use of an extension cord because the extension cord may overheat and cause a fire.
14. Always use properly grounded fused and polarized outlets.
15. Always use ground fault protection where it is required by electrical codes.
16. Always disconnect the power before performing any cleaning, maintenance or relocation of the
heater.
17. To prevent a possible fire, do not burn wood or other materials in this heater.
18. To prevent electric shock or fire, always use a certified electrician, should new circuits or outlets
be required.
19.
When transporting or storing the heater, keep it in a dry place, free from excessive vibration.
3
UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the
appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt
grounded outlet.
GROUNDING APPLIANCE
This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C)
is available for connecting three-blade grounding type plugs to two-slot receptacles. The green
grounding lug extending from the adapter must be connected to a permanent ground such as a
properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is
available.
To disconnect appliance, turn controls to off, then remove plug from outlet.
LOCATING THE FIREPLACE
Plan where to locate and frame the fireplace. This will save time and money later when you install
the fireplace. Before installation consider the following:
1. Where the fireplace is located must allow for wall and ceiling clearances (see
INSTALLATION-WALL MOUNT)
2. Consider a location where the fireplace screen will not be exposed to direct sunlight from
windows or doors.
3. A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location.
Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses
to blow.
4
WM-FM-50-BG
Description Built-in or Wall Mount Appliance
Voltage 120V AC 60Hz
Watts 1500W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 47 1/2” or 120.6 cm
Appliance Height 21 1/8” or 53.6 cm
Appliance Depth 6 1/8” or 15.5 cm
Gross Weight 127.6lbs or 58kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall
Opening Size
BTU 4800
48 1/2”× 22“ or
123.2 cm× 55.9 cm
This appliance has been tested in
accordance with the UL Standard 2021 for
fixed and location dedicated electric room
appliances in the United States and Canada.
If you need assistance during installation,
please contact your local dealer.
NOTE: This appliance must be electrically
wired and grounded in accordance with
local codes. In the absence of local codes,
use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA
70 National Electrical Code in the United
States.
5
REMOVING FRONT GLASS
The fireplace have 2 screws that secure the front glass in place.
Two people are required for the installation process.
1. The screws are located on the sides of the unit. Once located, unscrew the two or four screws.
You can then lift the front glass from the 4 shoulder posts on the sides of the unit and remove
the glass.
Screw locations on uintLift glass from shoulder posts
2. To replace the glass, lift onto the 4 shoulder posts. For a Wall Mount installation,replace the
two screws to secure the glass. For Flush Mount installs it is not possible to replace the screws.
6
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.