OUTDOOR INSTALLATIONS
For All TRU VIEW, SYMMETRY, PANORAMA, TRADITIONAL models
Our TRU VIEW,PANORAMA, SYMMETRY and TRADITIONAL electric fireplaces are suitable for
outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and
combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to
each side of the installed appliance. See illustration below. All wiring connections to line power shall be in
accordance with local building code requirements.
A
Side of
Fireplace
The overhang (A) must extend at least 1/2 the roof-line height (B).
Height is measured from the base of the replace.
For example: if the roof-line (B) is 8’ above the base of the replace,
the overhang (A) must be at least 4’.
B
AM-OUTDOOR-INSTALL Feb 2020