Amantii W004204706 Installation & Assembly

Page 1
OUTDOOR INSTALLATIONS
OUTDOOR INSTALLATIONS
For All TRU VIEW, SYMMETRY, PANORAMA, TRADITIONAL models
Our TRU VIEW,PANORAMA, SYMMETRY and TRADITIONAL electric fireplaces are suitable for outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements.
A
Side of
Fireplace
The overhang (A) must extend at least 1/2 the roof-line height (B). Height is measured from the base of the replace. For example: if the roof-line (B) is 8’ above the base of the replace, the overhang (A) must be at least 4’.
B
AM-OUTDOOR-INSTALL Feb 2020
Loading...