Amantii SYM-34, SYM-42, SYM-60, SYM-74, SYM-88 Installation Manual

...
ELECTRIC FIREPLACE
www.amantii.com
INSTALLATION AND OPERATION INSTRUCTIONS FOR
SYM-34 BESPOKE
BS1900034-1
SYM-42 BESPOKE
BS1900042-1
SYM-50 BESPOKE
BS1900050-1
SYM-60 BESPOKE
BS1900060-1
SYM-74 BESPOKE
BS1900074-1
SYM-88 BESPOKE
BS1900088-1
SYM-100 BESPOKE
BS1900100-1
SAFETY INFORMATION
WARNING
if the information in these instructions
are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
WARNING: This product can expose you to chemicals including lead in the wiring, which is [are] known to the State of California to cause birth defects of other reproductive harm. For more information visit: www.p65warnings.ca.gov
1
TABLE OF CONTENTS
Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product.
IMPORTANT INSTRUCTIONS CAUTIONS UNP ACKING AND TESTING APPLIANCE GROUNDING APPLIANCE LOCATING THE FIREPLACE PRODUCT SPECIFICATION OUTDOOR INSTALLATIONS INSTALLATION-WALL MOUNT INSTALLATION- BUILT-IN HARD- WIRE INSTALLATION DECORATIVE MEDIA INSTALLATION MANUAL OPERATION REMOTE CONTROL OPERATION TROUBLE SHOOTING
3 4 5 5 5 6 8 9
10
13 14
15
16
18 REPLACEMENT PARTS EXPLODED VIEW
19
21
2
1. Read all instructions before installing or using this heater.
2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front, sides and rear of the heater.
3. Always unplug heater when not in use.
4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way.
5. Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or anything else. Arrange the cord away from traffic areas where it could not be tripped over.
6. To disconnect the heater, turn the controls to "OFF" before removing the plug from the outlet.
7. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock, fire or damage to the heater.
8. To prevent a possible fire, do not block air intakes in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
10. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury.
11. Avoid the use of an extension cord, the extension cord will overheat and cause a fire. This heater is not to be used with an extension cord.
12. Always use properly grounded fused and polarized outlets.
13. Always use ground fault protection where it is required by electrical codes.
14. Always disconnect the power before performing any cleaning, maintenance or relocation of the heater.
15. To prevent a possible fire, do not burn wood or other materials in this heater.
16. To prevent electric shock or fire, always use a certified electrician, should new circuits or outlets be required.
17. When transporting or storing the heater, keep it in a dry place, free from excessive vibration.
18. This appliance should not be modified under any circumstances.
19. Packaging material should be kept away from children and be disposed of in a safe manner. Plastic bags are not toys and should be kept away from children and infants.
20. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
21. If the glass is damaged, do not use the heater in order to avoid a hazard.
22. Do not leave children unsupervised where heater is turned on.
23. CAUTION Some parts of this product can become very hot and cause burns. Particular atten­tion has to be given where children and vulnerable people are present.
SAVE THESE INSTRUCTIONS
3
CAUTIONS
Always install the heater in accordance with this guide. If in doubt obtain expert advice.
Always make sure the electrical socket is accessible and located adjacent to, but not above the heater.
Always disconnect the heater from the electrical supply before moving it, or
Do’s
Don’ts
carrying out cleaning, maintenance. Always make sure the heater is firmly secured to prevent it from being
tipped over. Always use a fireguard when young children and infirm persons can come
into contact with the heater.
Never leave children unsupervised in a room where the heater is ON and unguarded.
Never obstruct or cover the fan outlet or force items into heater openings.
Never use aerosols or steam cleaners on or around the heater.
Never route the main supply cable under carpet etc.
Never install the heater close to curtains or combustible materials.
Never use the heater to dry clothes etc.
Never sit or stand on the heater.
4
UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the
power supply cord into a 120 Volt grounded outlet. Test all aspects of its operation (manual switches, remote and heater) to make sure all
components are operating correctly. As with most electronic devices, your new electric fireplace has been designed to operate at
temperatures between 5 (41℉) and 35 (95). During the cold winter months, allow the fireplace to reach room temperature before turning it on.
NOTE: There may be trace of odor during the first few minutes of initial use. This is harmless, normal and will never occur again.
GROUNDING APPLIANCE
This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C) is available for connecting three-blade grounding type plugs to two-slot. The green
grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove plug from outlet.
A B
Metal Screw
Grounding Pin
Cover of Grounded Outlet Box
Cover of Grounded Outlet Box
CD
Adapter
Grounding Pin
Cover of Grounded Outlet Box
Grounding Lug
LOCATING THE FIREPLACE
Plan where to locate and frame the fireplace. This will save time and money later when you install the fireplace. Before installation consider the following:
1. Where the fireplace is located must allow for wall and ceiling clearances.
2. Consider a location where the fireplace screen will not be exposed to direct sunlight from windows or doors.
3. A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location. Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses to blow.
5
PRODUCT SPECIFICATION
This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer.
NOTE: This appliance must be electrically wired and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.
product model
Voltage
Watts
BTU
Appliance size
(W x H x D)
Glass Viewing
(W1 x H1 )
Frame size
(W2 x H2 )
Wall Opening Size
(W3 x H3 x D3 )
BS1900034-1
(SYM-34 BESPOKE)
120V AC 60Hz
1500W Max 1500W Max 1500W Max 1500W Max
4095 4095 4095 4095
32 3/8”x 15 5/8” x 5 1/2”
82.3 x 39.6 x 14 cm
30 5/8” x 13 1/8”
77.7 x 33.2 cm
34 1/2” x 16 7/8”
87.5 x 43 cm
32 7/8” x 16” x 6”
83.5 x 40.6 x 152 cm
BS1900042-1
(SYM-42 BESPOKE)
120V AC 60Hz 120V AC 60Hz 120V AC 60Hz
42 1/4”x 15 5/8” x 5 1/2”
112.5 x 39.6 x 14 cm
40 3/8” x 13 1/8”
102.7 x 33.2 cm
44 1/4” x 16 7/8”
112.5 x 43 cm
42 3/4” x 16” x 6”
108.6 x 40.6 x152 cm
BS1900050-1
(SYM-50 BESPOKE)
50 1/4”x 15 5/8” x 5 1/2”
127.6 x 39.6 x 14 cm
48 1/2” x 13 1/8”
123.1 x 33.2 cm
52 1/4” x 16 7/8”
132.7 x 43 cm
50 3/4” x 16” x 6”
128.9 x 40.6 x152 cm
(SYM-60 BESPOKE)
60 1/4”x 15 5/8” x 5 1/2”
153 x 39.6 x 14 cm
154.3 x 40.6 x152 cm
BS1900060-1
58 3/8” x 13 1/8”
148.4 x 33.2 cm
58 3/8” x 16 7/8”
112.5 x 43 cm
60 3/4” x 16” x 6”
Cord Length
H2 H1
70.9” < L < 95.5”
180 cm < L < 240 cm
W2 W1
W
70.9” < L < 95.5”
180 cm < L < 240 cm
D
H
70.9” < L < 95.5”
180 cm < L < 240 cm
H
W
70.9” < L < 95.5”
180 cm < L < 240 cm
D
6
product model
BS1900074-1
(SYM-74 BESPOKE)
BS1900088-1
(SYM-88 BESPOKE)
BS1900100-1
(SYM-100 BESPOKE)
Voltage
Watts
BTU
Appliance size
(W x H x D)
Glass Viewing
(W1 x H1 )
Frame size
(W2 x H2 )
Wall Opening Size
(W3 x H3 x D3)
Cord Length
120V AC 60Hz
1500W Max 1500W Max 1500W Max
4095 4095 4095
74 1/4” x 15 5/8” x 5 1/2”
188.5 x 39.6 x 14 cm
72 3/8” x 13 1/8”
184 x 33.2 cm
76 1/4” x 16 7/8”
193.7 x 43 cm
74 3/4” x 16” x 6”
189.9 x 40.6 x 152 cm
70.9” < L < 95.5”
180 cm < L < 240 cm
120V AC 60Hz 120V AC 60Hz
88 1/4” x 15 5/8” x 5 1/2”
224.1 x 39.6 x 14 cm
86 3/8” x 13 1/8”
219.5 x 33.2 cm
90 1/4” x 16 7/8”
229.3 x 43 cm
90 1/4” x 16” x 6”
229.3 x 40.6 x 152 cm
70.9” < L < 95.5”
180 cm < L < 240 cm
100 1/4” x 15 5/8” x 5 1/2”
254.6 x 39.6 x 14 cm
98 3/8” x 13 1/8”
250 x 33.2 cm
102 1/4” x 16 7/8”
254.6 x 43 cm
100 3/4” x 16” x 6”
254.6 x 40.6 x 152 cm
70.9” < L < 95.5”
180 cm < L < 240 cm
H2 H1
W2 W1
W
D
H
H
D
W
7
Loading...