Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS
Please read and carefully follow all of the instruction found in this manual. Please pay special
attention to the safety instructions provided in this manual. The instructions included here will assure
that you have many years of dependable and enjoyable service from your Amantii product.
IMPORTANT INSTRUCTIONS....................................................................................................................................3
UNPACKING AND TESTING APPLIANCE...............................................................................................................5
LOCATING THE FIREPLACE.....................................................................................................................................5
FOR BATHROOM USE..............................................................................................................................................
MEDIA OPTIONS.......................................................................................................................................................20
SERVICE HISTORY....................................................................................................................................................27
1. Read all instructions before installing or using this heater.
2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at
least 3 feet from the front of the heater; keep them away from sides and rear as well.
3. Always unplug heater when it’s not in use.
4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the
unit has been dropped or damaged in any way.
5. Never place the heater where it may fall into a bathtub or other water containers.
6. Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or anything
else. Arrange the cord away from traffic areas where it could not be tripped over.
7. To disconnect the heater, turn the controls to "OFF" before removing the plug from the outlet.
8. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may
cause an electric shock, fire or damage to the heater.
9. To prevent a possible fire, do not block air intakes in any manner.
10. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint
or flammable liquids are used or stored.
11. Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock or injury to persons.
12. Avoid the use of an extension cord because the extension cord may overheat and cause a fire.
13. Always use properly grounded fused and polarized outlets.
14. Always use ground fault protection where it is required by electrical codes.
15. Always disconnect the power before performing any cleaning, maintenance or relocation of the
heater.
16. To prevent a possible fire, do not burn wood or other materials in this heater.
17. To prevent electric shock or fire, always use a certified electrician, should new circuits or
outlets be required.
18. When transporting or storing the heater, keep it in a dry place, free from excessive vibration.
19. This appliance should not be modified under any circumstances.
20.
Packaging material should be kept away from children and be disposed of in a safe manner.
Plastic bags are not toys and should be kept away from children and infants.
Do not use this heater in small rooms when they are occupied by persons not capable of leaving
21.
the room on their own, unless constant supervision is provided.
If the glass is damaged, do not use the heater in order to avoid a hazard.
22.
Children of less than 3 years should be kept away from unless continuously supervised.
23.
CAUTION Some parts of this product can become very hot and cause burns. Particular attention
24.
has to be given where children and vulnerable people are present.
3
Cautions
·Always install the heater in accordance with this guide. If in
·Always make sure the electrical socket is accessible and located
Do’s
Don’ts
·Always disconnect the heater from the electrical supply before
·Always make sure the heater is firmly secured to prevent it from
·Always use a fireguard when young children and infirm persons
·Never leave children unsupervised in a room where the heater is
·Never obstruct or cover the fan outlet or force items into heater
·Never use aerosols or steam cleaners on or around the heater.
·Never route the mains supply cable under carpet etc.
·Never install the heater close to curtains or combustible
·Never use the heater to dry clothes etc.
·Never sit or stand on the heater.
·Never use with a timer or any other device that switches the fire
doubt obtain expert advice.
adjacent to, but not above the heater.
moving it, or carrying out cleaning, maintenance.
being tipped over.
can come into contact with the heater.
ON and unguarded.
openings.
materials.
on automatically.
4
UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box.
Prior to installing the appliance, test to make sure the appliance operates properly by
plugging the power supply cord into a conveniently located 120 Volt grounded outlet.
Test all aspects of its operation (manual switches, remote and heater) to make sure all
components operate correctly.
As with most electronic devices, your new electric fireplace has been designed to operate at
temperatures between 5 ℃ (41℉) and 35 ℃ (95℉). During the cold winter months, allow the
fireplace to reach room temperature before turning it on.
NOTE: There may be trace of odor during the first few minutes of initial use. This is
harmless, normal and will never occur again.
GROUNDING APPLIANCE
This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as
shown in (C) is available for connecting three-blade grounding type plugs to two-slot
receptacles. The green grounding lug extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove plug from outlet.
LOCATING THE FIREPLACE
Plan where to locate and frame the fireplace. This will save time and money later when you
install the fireplace. Before installation consider the following:
1. Where the fireplace is located must allow for wall and ceiling clearances
2. Consider a location where the fireplace screen will not be exposed to direct sunlight from
windows or doors.
3.
A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the
location. Preferably a dedicated branch circuit should be provided to avoid circuit
breakers to trip of fuses to blow.
5
BI-40-SLIM
Description Built-in Appliance
Voltage 120V AC 60Hz
Watts 1500W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 38 5/8” or 98.1 cm
Appliance Height 23 5/8” or 60 cm
Appliance Depth 6 3/4” or 17.2 cm
Gross Weight 88 lbs or 40kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 40”× 25“ or
101.6 cm× 63.5 cm
BTU 4800
This appliance has been tested in
accordance with the UL Standard 2021
for fixed and location dedicated
electric room appliances in the United
States and Canada. If you need
assistance during installation, please
contact your local dealer.
NOTE: This appliance must be
electrically wired and grounded in
accordance with local codes. In the
absence of local codes, use the
current CSA C22.1 Canadian Electrical
Code in Canada or the ANSI/NFPA 70
National Electrical Code in the United
States.
6
BI-50-SLIM
Model Number BI-50-SLIM
Voltage 120V AC 60Hz
Watts 1500W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 48 5/8” or 123.5 cm
Appliance Height 23 5/8” or 60 cm
Appliance Depth 6 3/4” or 17.2 cm
Gross Weight 105.6 lbs or 48kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 50”× 25“ or
127 cm ×63.5 cm
BTU 4800
This appliance has been tested in accordance
with the UL Standard 2021 for fixed and
location dedicated electric room appliances
in the United States and Canada. If you need
assistance during installation, please contact
your local dealer.
NOTE: This appliance must be electrically
wired and grounded in accordance with
local codes. In the absence of local codes,
use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA
70 National Electrical Code in the United
States.
7
BI-60-SLIM
Description Built-in Appliance
Voltage 120V AC 60Hz
Watts 1500W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 58 5/8” or 148.5 cm
Appliance Height 23 5/8” or 60 cm
Appliance Depth 6 3/4” or 17.2 cm
Gross Weight 123.2 lbs or 56kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 60”× 25“ or
152.4 cm× 63.5 cm
BTU 4800
This appliance has been tested in accordance
with the UL Standard 2021 for fixed and
location dedicated electric room appliances
in the United States and Canada. If you need
assistance during installation, please contact
your local dealer.
NOTE: This appliance must be electrically
wired and grounded in accordance with
local codes. In the absence of local codes,
use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA
70 National Electrical Code in the United
States.
8
BI-72-SLIM
Description Built-in Appliance
Voltage 120V AC 60Hz
Watts 1500W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 72 1/8” or 183.2 cm
Appliance Height 23 5/8” or 60 cm
Appliance Depth 6 3/4” or 17.2 cm
Gross Weight 149.6lbs or 68kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 73 1/2”× 25“ or
186.7 cm× 63.5 cm
BTU 4800
This appliance has been tested in accordance
with the UL Standard 2021 for fixed and
location dedicated electric room appliances
in the United States and Canada. If you need
assistance during installation, please contact
your local dealer.
NOTE: This appliance must be electrically
wired and grounded in accordance with
local codes. In the absence of local codes,
use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA
70 National Electrical Code in the United
States.
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.