Date of purchase: _________________________________
Date of installation: _______________________________
Installer: ________________________________________
Model number: ___________________________________
Serial number: ___________________________________
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ....................................... 17
Date d’achat : _____________________________________
Date d’installation : ________________________________
Installateur : ______________________________________
Numéro de modèle : ________________________________
Numéro de série : __________________________________
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su
producto, visite:
www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad
superior de la puerta.
W10443045B
W10443046B-SP
1
DRYER SAFETY
2
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
3
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
Flat-blade screwdriver#2 Phillips screwdriver
Wire stripper (direct wire
installations)
1/4" nut driver
(recommended)
Tin snips (new vent
installations)
Vent clamps
8" or 10" pipe wrench
Pipe-joint compound
resistant to LP gas
8" or 10" adjustable wrench
(for gas connections)
Parts supplied (all models):
Leveling legs (4)
Parts supplied (steam models):
Tape measure
Level
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
4
Pliers
Caulking gun and compound
(for installing new exhaust vent)
Utility knife
“Y” connectorShort inlet hose
Long inlet hoseRubber washer
Parts package is located in dryer drum. Check that all parts
are included.
NOTE: If installing dryer on pedestal, do not use leveling legs.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about
accessories available for your dryer.
Parts needed: (Not supplied with dryer)
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
LOCATION REQUIREMENTS
27"
29"
You will need:
■A location allowing for proper exhaust installation.
See “Venting Requirements.”
■If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
■Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
■Cold water faucets located within 4 ft. (1.2 m) of the water ll
valves, and water pressure of 20–100 psi (137.9–689.6 kPa).
You may use the water supply for your washer using the “Y”
connector and short hose (if needed) which are provided.
■20–100 psi (138–690 kPa) for best performance.
■Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
■For garage installation, place dryer at least 18" (460 mm)
above oor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
For each arrangement, consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and oor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or louvered door is installed, top and bottom air openings
in door are required.
DRYER DIMENSIONS
Front view:
3
/8"
35
(899 mm)
1"
(25 mm)
Side view:
Door open view:
(686 mm)
(736 mm)
Left or
right side
exhaust
7
6
/8"
(174 mm)
471/8"
(1197 mm)
1
/8"
48
(1238 mm)
1
/2"
3
(89 mm)
5
1
/8"
(41 mm)
5
Back view:
1
6
/4"
(159 mm)
Closet installation (dryer only):
Electric
1
28
/8"
(715 mm)
1
/2"
3
(89 mm)
14"
(358 mm)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See “Venting
Requirements.”
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
45° F (7° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
34" recommended
(864 mm)
18" min.
(457 mm)
4"
(102 mm)
(25 mm)
1"
(25 mm)
Cabinet installation (dryer only):
7"
(178 mm)
1"
3"
(76 mm)
3"
(76 mm)
2
48 in.
(310 cm2)
2
24 in.
(155 cm2)
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
■Additional spacing should be considered for ease of
installation and servicing.
■Additional clearances might be required for wall, door, and
oor moldings.
■Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
■For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
■Companion appliance spacing should also be considered.
■No other fuel-burning appliance may be installed in the same
closet as the dryer.
4"
(102 mm)
1"
(25 mm)
18"
(460 mm)
1"
(25 mm)
6
Closet Installation (stacked washer and dryer):
6"
(152 mm)
3"
(76 mm)
71"
(1803 mm)
48 in.
(310 cm2)
ELECTRIC DRYER
POWER HOOKUP – CANADA ONLY
ELECTRICAL REQUIREMENTS
2
1
5
/
2"
(140 mm)
1"
(25 mm)
1"
(25 mm)
3"
(76 mm)
2
24 in.
(155 cm2)
Custom under counter installation (dryer only):
39" min.
(990 mm)
1"
(25 mm)
1"
(25 mm)
NOTE: Some models not recommended for undercounter
installation.
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
■Metal exhaust system hardware, available for purchase
from your dealer. For further information, see “Assistance
or Service” section in your Use and Care Guide.
■Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as
dryer exhaust opening.
For gas dryers mobile home installations:
■Mobile Home Installation Hold-down Kit Part Number
346764 is available to order. For further information, see
“Assistance or Service” section in your Use and Care Guide.
It is your responsibility:
■To contact a qualied electrical installer.
■To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
■To supply the required 4-wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
■This dryer is equipped with a CSA
International Certied Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer’s nal location.
4-wire receptacle
(14-30R)
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located
in “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
7
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
GAS SUPPLY REQUIREMENTS
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
re, or electrical shock.
■120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualied person make sure
gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualied person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or re.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is
design-certied by CSA International for LP (propane or
butane) gases with appropriate conversion.
■Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, contact your dealer
or call the phone numbers referenced in the “Assistance or
Service” section of your Use and Care Guide.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician.
No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a different
gas without consulting your gas company.
8
GAS SUPPLY LINE
■Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer.
®†
E
D
tape.
C
A
B
A. 3/8" exible gas connector
B. 3/8" pipe to are adapter tting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
■1/2" IPS pipe is recommended.
■3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
■If you are using natural gas, do not use copper tubing.
■Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter tting.
■If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
■Must include shut-off valve
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) ft. (1.8 m) of
the dryer. The location should be easy to reach for opening
and closing.
GAS SUPPLY CONNECTION REQUIREMENTS
■Use an elbow and a 3/8" are x 3/8" NPT adapter tting
between the exible gas connector and the dryer gas pipe,
as needed to avoid kinking.
■Use only pipe-joint compound. Do not use TEFLON
■This dryer must be connected to the gas supply line with a
®†
tape.
listed exible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 10,000 ft. (3,048 m):
■When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner Btu rating shown on the model/serial number
plate is required for each 1,000 ft. (305 m) increase in
elevation.
Gas supply pressure testing
■The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
DRYER GAS PIPE
■The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
1
1
/2"
(38 mm)
A
*61/4"
*5 3/4"
(159 mm)
A. 3/8" NPT dryer pipe
* NOTE: If the dryer is mounted on a pedestal, the gas pipe
height must be an additional 10" (254 mm) or 15.5" (394 mm)
from the oor, depending on the pedestal model. For a garage
installation, the gas pipe height must be an additional 18"
(460 mm) from the oor.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
9
VENTING
VENTING REQUIREMENTS
Exhaust hoods:
■ Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as owers, rocks, bushes, or
snow).
Recommended Styles:
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
■ Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■ Do not use plastic or metal foil vent.
Rigid metal vent:
■ Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
■ Must be fully extended and supported in nal dryer location.
■ Remove excess to avoid sagging and kinking that may
result in reduced airow and poor performance.
■ Do not install in enclosed walls, ceilings, or oors.
■ The total length should not exceed 7
3
/4 ft. (2.4 m).
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Elbows:
■ 45° elbows provide better airow than 90° elbows.
Recommended Styles:
Good
Better
Clamps:
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
NOTE: If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood
is not plugged with lint. Replace plastic or metal foil vents
with rigid metal or exible metal vents. Review “Vent System
Charts” and, if necessary, modify existing vent system to
achieve best drying performance.
10
Vent products can be purchased from your dealer. For more
information, see “Assistance or Service” section in your Use and
Care Guide.