Amana W10150612B, W10150613B User Manual

29" (73.7 CM) ELECTRIC DRYER
INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE
ÉLECTRIQUE DE 29" (73,7 CM)
Table of Contents / Table des matières
SÉCURI
DRYER SAFETY............................................... 1
INSTALLATION INSTRUCTIONS.................... 2
Tools and Par
Location Requirements ................................2
Electrical Requirements - U.S.A. .................. 3
Electrical Requirements - Canada................ 5
Electrical Connection - U.S.A. Only.............. 6
Venting Requirements................................. 11
Plan Vent System........................................ 12
Install Vent System...................................... 13
Install Leveling Legs.................................... 13
Level Dryer .................................................. 13
Connect Vent............................................... 13
Reverse Door Swing (Optional)................... 14
Complete Installation .................................. 15
ts ............................................. 2
TÉ DE LA SÉCHEUSE ......................16
INSTRUCTIONS D’INSTALLATION...............17
Outillage et pièces .......................................17
Exigences d’emplacement ..........................17
Spécifications électriques- Canada.............18
Exigences concernant l'évacuation.............19
Planification du système d’évacuation........20
Installation du système d’évacuation ..........21
Installation des pieds de nivellement...........21
Mise à niveau de la sécheuse......................22
Raccordement du conduit d’évacuation .....22
Inversion du sens d'ouverture de la
porte (facultatif)............................................22
Achever l’insta
llation....................................23
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite: www.whirlpool.com.
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
W10150612B
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Flat-blade screwdriver #2 Phillips screwdriver Adjustable wrench that
opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)
Wire stripper (for U.S. only, direct wire installations)
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
4 leveling legs
Parts needed:
Check local codes, check existing electrical supply and venting and see “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom your dryer. For further information, please reference the “Assistance or Service” section of the Dryer User Instructions.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
2
Tin snips (new vent installations)
Level Vent clamps Caulking gun and
compound (for installing new exhaust vent)
Tape measure
you purchased
Location Requirements
You will need
A location that allows for proper exhaust installation. See “Venting Requirements.”
A separate 30-amp circuit. If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire dryer. (If slope is greater than 1" [25 mm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
or stored in an area where it will be
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
Companion appliance spacing should also be considered.
14" max.* (356 mm)
18"* (457 mm)
48 in. (310 cm )
2
*
2
3"* (76 mm)
3
43 "
8
(1102 mm)
*26"
(660 mm)
3
43 "
8
(1102 mm)
*27¾"
(705 mm)
29"
(737 mm)
A
29"
(737 mm)
C
15¼"
(387 mm)
22¾"
(578 mm)
3
8
43 "
(1102 mm)
*27¾" (705 mm)
3
43 "
(1102 mm)
*27¾"
(705 mm)
29"
(737 mm)
B
8
29"
(737 mm)
22¾"
(578 mm)
13¾"
(349 mm)
D
A. Small opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should
nsidered for the following reasons:
be co
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
2
*
1" (25 mm)
29"
(737 mm)
A
1" (25 mm)
1"* (25 mm)
27¾" (705 mm)
B
5"* (127 mm)
24 in. (155 cm )
2
C
3"* (76 mm)
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
*Required spacing
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
Electrical Requirements - U.S.A.
It is your responsibility
To contact a qualified electrical installer. To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
3
Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secure the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
d under
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge solid copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum). At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
For a permanently connected dryer:
This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
WARNING:
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Improper connection of the equipment-
SAVE THESE INSTRUCTIONS
4
Electrical Requirements - Canada
WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility
To contact a qualified electrical installer. To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.
4-wire receptacle 14-30R
Do not use an extension cord.
If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 3394208. For further information, please reference the service numbers located in the Dryer User Instructions
.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
5
Electrical Connection - U.S.A. Only
A
Power Supply Cord Direct Wire
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
A B C D
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
3. Install strain relief. Style 1: Power supply cord strain relief
Remove the screws from a " (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.
3
4
B
C D
A. Terminal block cover B. External ground conductor screw C. Center, silver-colored terminal block screw D. Hold-down screw location E. Neutral ground wire
F. Hole below terminal block opening
E
F
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
6
Put power supply cord through the strain relief. Be sure
A
that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
Electrical Connection Options
If your home has: And you will be
connecting to:
4-wire receptacle (NEMA Type 14-30R)
A UL listed, 120/240-volt minimum, 30-amp, dryer power supply cord*
Go to Section
4-wire connection: Power supply cord
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any screws from a " (19 mm) UL listed strain relief (UL
3
4 marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.
A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads
4-wire direct A fused
disconnect or circuit breaker
5"
(127 mm)
3-wire receptacle (NEMA type 10-30R)
box*
A UL listed, 120/240-volt minimum,
4-wire connection: Direct Wire
3-wire connection: Power supply cord
30-amp, dryer power supply cord*
3-wire direct A fused
disconnect or circuit breaker
1
3 "
2
(89 mm)
box*
3-wire connection Direct Wire
:
*If local codes do not permit the connection of a cabinet-ground
B
conductor to the neutral wire, go to “Optional 3-wire connection” section.
4-wire connection: Power Supply Cord
C
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
B
F
A
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
4. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
D
C
A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong D. Neutral prong E. Spade terminals with upturned ends
F. ¾" (19 mm) UL listed strain relief
G. Ring terminals
E
G
7
1. Remove center silver-colored terminal block screw.
"
C
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver­colored terminal block screw. Tighten screw.
A
B
C
E
D
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw. B. Center silver-colored terminal block screw C. Neutral wire (white or center wire) D. ¾" (19 mm) UL listed strain relief E. Neutral ground wire
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 1 3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.
When connecting to the terminal block, place the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1
2" (38 mm) from
1
(25 mm)
5"
(127 mm)
the hooked end of
A
B
C
EF
D
A. External ground conductor screw B. Center silver-colored terminal block screw C. Neutral wire (white or center wire) D. ¾" (19 mm) UL listed strain relief E. Ground wire (green or bare) of power supply cord
F. Neutral ground wire
4. Connect the other wires to outer terminal block screws.
Tighten screws.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
A
B
E
D
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.
B. Center silver-colored terminal block screw C. Neutral wire (white or center wire) D. ¾" (19 mm) UL listed strain relief
E. Neutral ground wire
ghten strain relief screws.
5. Ti
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connections. Now go to
“Venting Requirements.”
8
Loading...
+ 16 hidden pages