Evaporator Coil Freeze Pro tec tion
•
Compressor Restart Delay
•
Low Ambient Lock-out
•
Manual Outside Air Damper
•
Wall-mount Thermostat
•
Electrical Disconnect
•
Random Unit Restart
•
Front Desk Control
•
Fan On/Off Delay
•
High-effi ciency Operation
•
Quiet Operation
•
Reliability and Durability
•
¾ Ton through 2 Tons
SS-VTACwww.goodmanmfg.com5/08
COOLING: 8,350 - 23,800 BTU/H
H
EAT PUMP: 8,120 - 22,800 BTU/H
ELECTRIC HEAT: 5,100 - 34,100 BTU/H
UPTO 3.5 COP
Supersedes 12/07
P
RODUCT SPECIFICATIONS
FEATURES
Front Desk Control
•
Enable or disable each unit from the front desk to save energy
used to con di tion unoccupied rooms.
Fan Delay
•
Allows the evaporator blower to con tin ue running for up to 45 sec .
after the ther mo stat is satisfi ed, maximizing cooling performance.
Random Restart
•
Protects against damage to electrical circuits by preventing all
units from starting at one time after power disruption. Random
restart occurs in 3 to 4 min.
Evaporator Coil Freeze Protection
•
Prevents ice build-up on coils and compressor damage during
the cooling mode. Attached to the coil, a temperature sensor
will de-energize the compressor when freezing conditions are
detected and re-energize the compressor when the coil warms
up again.
Ductable Return Air
•
Permits the con nec tion of return air ductwork using the provid-
ed tabs (usually not required) on the inlet of the evap o ra tor coil.
(Figure 5, pg. 9)
Note: Duct systems and registered sizes must be properly designed for
the CFM and external static pressure rating of the unit.
Adjustable Outside Air (manual)
•
Meets code re quire ments for outside air introduction. The air
vent (Figure 6, pg. 9) allows up to 50 CFM of outside air to be
introduced into the equipment closet. The air mixes with return
air entering the closet through the return air grille.
Note: Negative pressure can be introduced through an external source to
raise the 50 CFM level. Consult with the factory.
Compressor Restart Delay – (3 min.)
•
Ensures that system pressure equalizes before the system re-
starts, so compressor life is extended.
Low Ambient Lockout
•
Locks out compressor at 40ºF and below, thus extending com-
pressor life.
Electrical Dis con nect (Factory-installed)
•
Makes service and maintenance easier.
Filter Brackets (Field-installed)
•
Installed over evaporator coil and shipped with throw-away fi l-
ter (20” x 24” x 1”; see Figure 5, pg. 9).
Unique “Sleeve Drain” Condensate System
•
(Factory-installed) – Connects evaporator drain pan to a vertical
pipe connection in the unit’s base pan via a drain line. Evaporator condensate is delivered from the unit to a catch tray in the
wall sleeve and exits the sleeve through the ¾” male NPT fi tting
to allow complete piping of the drain to a condensate riser during the rough-in stage. This eliminates condensate connection
problems when connecting the HVAC drain to the riser after the
HVAC unit is installed in the closet. Unit can be removed for
service without disconnecting the condensate piping. Additional
closet space is not needed to connect the drain.
Secondary Overfl ow
•
Should the primary condensate riser become clogged, water will
fi ll the catch tray and be diverted through the sleeve to the exterior of the building, ensuring no leakage into the interior area.
Rain water entering the sleeve is automatically diverted to the
building exterior.
NOMENCLATURE
VT09
4,5
3
Product CategoryEngineering
VVertical Package Revisions
Terminal Unit
Model TypeA Standard Model
CAir ConditionerH Hot Water Model
HHeat Pump