Amana NTW4600V, NTW5100T, NTW4500V, NTW4800V User Manual

39"
(99 c m )
28"
(71 c m )
Washer
PRODUCT MODEL NUMBERS
DRAIN SYSTEM OPTIONS
NTW5100T NTW5400T NTW4500V
Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. electrical supply. A time-delay fuse or circuit breaker and separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10200331B
09-04-08
RECESSED AREA OR CLOSET INSTALLATION
If a closet door is installed, the minimum ventilation openings in the top and bottom of the door are required (view 3). Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
Laundry tub drain system (view 3)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 39 in. (99 cm) above the floor and no higher than 96 in. (244 cm) from the bottom of the washer.
Floor drain system (view 4)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28 in. (71 cm) from the bottom of the washer. Additional hoses might be needed.
"
"
"
"
"
"
"
"
"
"
"
"
12 3
39"
(99 c m )
Front view Side view Closet door with vents
®
12
34
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2 in. (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 39 in. (99 cm) high and no higher than 96 in. (244 cm) from the bottom of the washer. IMPORTANT: To avoid siphoning, no more than 8" (20.3 cm) of drain hose should be inside the standpipe.
Loading...