WASHER INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L’INSTALLATION DE LA LAVEUSE
Table of Contents Table des matières
WASHER SAFETY ..............................................................1
INSTALLATION REQUIREMENTS .....................................2
Tools and Parts ..................................................................... 2
Location Requirements .......................................................2
Drain System ........................................................................ 3
Electrical Requirements ......................................................4
INSTALLATION INSTRUCTIONS .......................................4
Connect Drain Hose ............................................................. 5
Connect Inlet Hoses ............................................................. 6
Level Washer ........................................................................7
Complete Installation Checklist .......................................... 8
Para obtener acceso al instrucciones de instalación en español, o para obtener información adicional acerca
de su producto, visite: www.whirlpool.com
INSTALLATION NOTES
Date of purchase: _________________________________ Date of installation: _______________________________ Installer: ________________________________________ Model number: ___________________________________ Serial number: ___________________________________
EXIGENCES D’INSTALLATION .........................................9
Outillage et pièces ................................................................. 9
Exigences d’emplacement ................................................. 10
Système de vidange ............................................................. 11
Spécications électriques ................................................... 11
INSTRUCTIONS D’INSTALLATION .................................12
Raccordement du tuyau de vidange...................................13
Raccordement des tuyaux d’arrivée d’eau ........................ 14
Établissement de l’aplomb de la laveuse ........................... 15
Liste de vérication pour l’achèvement de l’installation .. 16
NOTES SUR L’INSTALLATION
Date d’achat : ____________________________________ Date d’installation : _______________________________ Installateur : _____________________________________ Numéro de modèle : _______________________________ Numéro de série : _________________________________
WASHER SAFETY
W10240509E W10240510E-SP
INSTALLATION REQUIREMENTS
Tools and Parts
Gather required tools and parts before starting installation.
Tools needed:
Adjustable or open end wrench
9
/16" (14 mm)
Level
4" min
(102 mm)
Wood block
Pliers that open to
3
⁄4" (44.5 mm)
1
Optional tools:
Flashlight Bucket
Parts supplied:
NOTE: All parts supplied for installation are in
cardboard insert in the top of the washer.
Ruler or measuring tape
Parts needed: (Not supplied with washer)
Inlet hoses with flat washers
To order, please refer to toll-free phone numbers on back page of your Use and Care Guide.
n
8212656RP 10 ft. (3.0 m) Inlet hose, Black EPDM (2 pack)
n
8212641RP 5 ft. (1.5 m) Inlet hose, Black EPDM (2 pack)
n
8212646RP 4 ft. (1.2 m) Inlet hose, Black EPDM (2 pack)
n
8212545RP 5 ft. (1.5 m) Inlet hose, Red and Blue EPDM
(2 pack)
n
8212487RP 5 ft. (1.5 m) Nylon braided inlet hose (2 pack)
n
8212638RP 6 ft. (1.8 m) Nylon braided inlet hose, space
saving 90° elbow, hypro-blue steel couplings
(2 pack)
n
8212637RP 6 ft. (1.8 m) Inlet hose, Black EPDM, space
saving 90° elbow, hypro-blue steel couplings (2 pack)
Alternate parts: (Not supplied with washer)
Your installation may require additional parts. To order, please refer to toll-free numbers on back page of your Use and Care Guide.
If you have: You will need:
Overhead sewer Standard 20 gal. (76 L) 39" (990 mm) tall drain tub or utility sink, sump pump and connectors (available from local plumbing suppliers)
1" (25 mm) standpipe 2" (51 mm) diameter to 1" (25 mm) diameter Standpipe Adapter Part Number 3363920 Connector Kit Part Number 285835
Drain hose too short Extension Drain Hose Part Number 285863 Connector Kit Part Number 285835
Lint clogged drain Drain Protector Part Number 367031 Connector Kit Part Number 285835
Drain hose with clamp, U-form, and cable tie
2
LOCATION REQUIREMENTS
Select proper location for your washer to improve performance and minimize noise and possible “washer walk”. Install your washer in a basement, laundry room, closet, or recessed area.
1
/2"
43"
42"
(1092 mm)
(1067 mm)
27
(699 mm)
27"
(686 mm)
You will need:
3"
(25 mm)
4.5"
(114 mm)
n
A water heater set to 120° F (49° C).
n
A grounded electrical outlet located within 4 ft (1.2 m) of
power cord on back of washer.
n
Hot and cold water faucets located within 3 ft (0.9 m) of hot
and cold water ll valves on washer, and water pressure of 20-100 psi (138-690 kPa).
n
A level oor with maximum slope of 1" (25 mm) under entire
washer. Installing on carpet is not recommended.
n
Floor must support washer’s total weight (with water and load)
of 315 lbs (143 kgs).
IMPORTANT: Do not install, store, or operate washer where it will be exposed to weather or in temperatures below 32° F (0° C). Water remaining in washer after use may cause damage in low temperatures. See “Washer Care” in your Use and Care Guide for winterizing information.
Proper installation is your responsibility.
Recessed area or closet installation
(76 mm)
DRAIN SYSTEM
Drain system can be installed using a oor drain, wall standpipe, oor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
39"
4.5"
(114 mm)
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe must be at least 39" (990 mm) high; install no higher than 96" (2.44 m) from bottom of washer. If you must install higher than 96" (2.44 m), you will need a sump pump system.
It is the responsibility of the installer to install and secure the drain hose into the provided plumbing/drain in a manner that will avoid the drain hose coming out of or leaking from the plumbing/drain.
Wall standpipe drain system
(990 mm)
14" max.
(356 mm)
5"
(126 mm)
1"
17"
(432 mm)
1"
(25 mm)
3"
(76 mm)
2
48 in.
(310 cm2)
2
24 in.
(155 cm2)
Dimensions show recommended spacing allowed, except for closet door ventilation openings which are minimum required. This washer has been tested for installation with spacing of 0" (0 mm) clearance on the sides. Consider allowing more space for ease of installation and servicing, and spacing for companion appliances and clearances for walls, doors, and oor moldings. Add spacing of 1" (25 mm) on all sides of washer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.
4.5"
(114 mm)
See requirements for oor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an Extension Drain Hose (Part Number 285863) that may be purchased separately. To order, please see toll-free phone numbers in your Use and Care Guide. Minimum siphon break: 28" (710 mm) from bottom of washer. (Additional hoses may be needed.)
Laundry tub drain system
39"
(990 mm)
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 39" (990 mm) above oor; install no higher than 96" (2.44 m) from bottom of washer.
IMPORTANT: To avoid siphoning, no more than 4.5" (114 mm) of drain hose should be inside standpipe or below the top of wash tub. Secure drain hose with cable tie.
3
ELECTRICAL REQUIREMENTS
n
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit breaker serving only this appliance be provided.
n
This washer is equipped with a power supply cord having
a 3 prong grounding plug.
n
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualied electrician.
n
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the ground path is adequate.
n
Do not ground to a gas pipe.
n
Check with a qualied electrician if you are not sure the
washer is properly grounded.
n
Do not have a fuse in the neutral or ground circuit.
INSTALLATION INSTRUCTIONS
Before you start: remove shipping materials It is necessary to remove all shipping materials for proper
operation and to avoid excessive noise from washer.
1. Move washer
48"
(1.2 m)
Move washer to within 4 ft (1.2 m) of its nal location; it must be in a fully upright position.
NOTE: To avoid oor damage, set washer onto cardboard before moving it and make sure lid is taped shut.
2. Remove shipping base
To avoid damaging oor, place cardboard supports from shipping carton on oor behind washer. Tip washer back and place on cardboard supports. Remove shipping base. Set washer upright.
IMPORTANT: Removing shipping base is necessary for proper operation. If your washer includes a sound shield, please refer to the instructions included with the sound shield to install it at this time.
4
3. Remove packing tray from tub
Remove tape from washer lid, open lid and remove cardboard packing tray from tub. Be sure to remove all parts from tray.
NOTE: Keep tray in case you need to move washer later.
4. Free power cord
CONNECT DRAIN HOSE
5. Attach drain hose to drain port
Remove the red plastic plug from the black drain port on the back of the washer.
If clamp is not already in place on elbow end of drain hose, slide it over end as shown. Squeeze clamp with pliers and slide black elbow end of drain hose onto black drain port and secure with clamp.
For a laundry tub or standpipe drain, go to step 6. For a oor drain, remove the preinstalled drain hose form as
shown in Step 7. You may need additional parts with separate directions. See “Tools and Parts”.
Firmly grasp power cord plug and pull to free from rear panel. Gently place power cord over console to allow free access to back of washer.
6. Place drain hose in standpipe
Drain hose form
4.5"
(114 mm)
Place hose into standpipe (shown in picture) or over side of laundry tub.
IMPORTANT: 4.5" (114 mm) of drain hose should be inside standpipe; do not force excess hose into standpipe or lay on bottom of laundry tub. Drain hose form must be used.
5
Loading...
+ 11 hidden pages