PRODUCT MODEL NUMBERS
NEC3240F
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
81/4"
235/8"
1"
Front View
Side View
(914 mm)
1"
(25 mm)
Back View
237/8"
(606 mm)
3
20
/4"
(527 mm)
117/8"
3
/4"
*20
(527 mm)
31"
1"
(25 mm)
31/4"
Minimum spacing for recessed area and closet installation
The following dimensions shown are for the minimum spacing allowed when the dryer is to be operated with, or without, the Stack Stand Kit. To purchase a Stack Stand Kit, see “Assistance or Service.”
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
For closet installation with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
14"* (356 mm)
18"* (457 mm)
1"
51/2"*
(140 mm)
(25 mm)
A. Side view - closet or confined area B. Recessed area
*Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbows. See “Venting Requirements.”
Recessed or closet installation - Stacked
1"*
(25 mm)
51/2"
(76 mm)
12"*
12"*
1"
(25 mm)
DRYER
WASHER
1"
(25 mm)
A B
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
Mobile Home - Additional Location Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 245, HUD Part 280) or Standard CAN/CSA­Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
1"
2
48 in. *
(309.7 cm )
2
24 in. *
(154.8 cm )
C
3"*
(76 mm)
2
2
3"*
(76 mm)
W10773360A
05/2016
INSTALLATION REQUIREMENTS
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
VENTING REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
Recommended Style:
Louvered hood Box hood
Acceptable Style:
Determine vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the “Vent System Chart” below to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The “Vent System Chart” provides venting requirements that will help to achieve the best drying performance.
Vent System Chart
Number of 90° turns or elbows
0
1
2
Type of vent Box or
louvered hoods
Rigid metal 36 ft (11 m) 26 ft (7.9 m)
Rigid metal 26 ft (7.9 m) 16 ft (4.9 m)
Rigid metal 16 ft (4.9 m) 6 ft (1.8 m)
Angled hoods
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.