Amana NEC3120F Dimension Guide

Electric Dryer
AB
(25 mm)
PRODUCT MODEL NUMBERS
NEC3120F
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Front View
3
/4"
*20
(527 mm)
32"
(787 mm)
3
1
/4"
/4"
(44 mm)
237/8"
(606 mm)
Side View
36"
(914 mm)
(527 mm)
20
3
Minimum spacing for recessed area and closet installation
The following dimensions shown are for the minimum spacing allowed when the dryer is to be operated with, or without, the Stack Stand Kit. To purchase a Stack Stand Kit, see “Assistance or Service.”
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
For closet installation with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
14"* (356 mm)
18"* (457 mm)
1"
51/2"*
(140 mm)
(25 mm)
1"
13/4"
(44 mm)
Back View
1
3
/2"
(89 mm)
1
/4"
29
(743 mm)
7
/8"
13/4"
(44 mm)
11
(303 mm)
31/4"
(83 mm)
A. Side view - closet or confined area B. Recessed area
*Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbows. See “Venting Requirements.”
Recessed or closet installation - Stacked
12"*
(305 mm)
12"*
(305 mm)
1"
(25 mm)
51/2"
(76 mm)
DRYER
WASHER
1"
(25 mm)
1"* (25 mm)
(309.7 cm )
(154.8 cm )
A B
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
48 in. *
24 in. *
3"*
(76 mm)
2
2
2
2
3"*
(76 mm)
C
Mobile Home - Additional Location Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 245, HUD Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase
from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
W10773366A
03/2016
INSTALLATION REQUIREMENTS
ELECTRICAL REQUIREMENTS
■ 120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required.
■ A time-delay fuse or circuit breaker is recommended.
Check that the fuse or circuit breaker matches the rating of your line.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
VENTING REQUIREMENTS
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
Recommended Style:
Louvered hood Box hood
Acceptable Style:
Angled hood
Determine vent path
Select the route that will provide the straightest and most
direct path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the “Vent System Chart” below to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The “Vent System Chart” provides venting requirements that will help to achieve the best drying performance.
Vent System Chart
Number of 90º turns or elbows
0
1
2
Type of vent Box or
louvered hoods
Rigid metal 36 ft (11 m) 26 ft (7.9 m)
Rigid metal 26 ft (7.9 m) 16 ft (4.9 m)
Rigid metal 16 ft (4.9 m) 6 ft (1.8 m)
Angled hoods
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.