Amana Heat Pump 10730418 User Manual

P
ACKAGE
H
EAT
P
UMP
INSTALLATION INSTRUCTIONS
Installer: Affix literature adjacent to the unit.
Part No. 10730418 Printed in USA
is a trademark of Maytag Corporation and is used under
license to Goodman Company, L.P. All rights reserved.
*NOTE: Please contact your distributor or our website for
the applicable product data book referred to in this
Goodman Company, L.P.
1810 Wilson Parkway • Fayetteville, Tennessee 37334
www.amana-hac.com
2000-2004 Goodman Company, L.P.
Effective: May 2004
SAFETSAFET
SAFET
SAFETSAFET
Y INSTRY INSTR
Y INSTR
Y INSTRY INSTR
UCUC
UC
UCUC
TITI
TI
TITI
OO
O
OO
NSNS
NS
NSNS
RECOGNIZE SAFETY SYMBOLS, WORDS, AND LABELS
The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of personal injury, property damage, and/or product damage.
WARNING
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
CAUTION
CAUTION - Hazards or unsafe practices which COULD result in minor or moderate personal injury, product damage, property dam-
age.
WARNING
O PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO
T
CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE UNIT AND TO REPLACE ANY PART OF THE CONTROL SYSTEM WHICH HAS BEEN UNDER WATER.
USE THIS UNIT IF ANY PART OF THE UNIT HAS BEEN UNDER WATER. IMMEDIATELY
NOT
WARNING
O PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO IMPROPER INSTALLATION, ADJUSTMENTS, ALTERATIONS, SERVICE OR MAINTENANCE,
T
CONSULT THIS MANUAL, THE SERVICE MANUAL, A QUALIFIED INSTALLER OR A SERVICE AGENCY.
WARNING
HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL(S) WHICH MAY CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN BY THE STATE OF
T
ALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
C
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This includes all
safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety
warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than
when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a
customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good
safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there
is a direct conflict between existing practices and the content of this manual, the precautions listed here take
precedence.
2
GENERAL INFOGENERAL INFO
GENERAL INFO
GENERAL INFOGENERAL INFO
RMRM
RM
RMRM
AA
A
AA
TITI
TI
TITI
OO
O
OO
NN
N
NN
TO THE INSTALLER
Before installing this unit please read this manual and the Product Data Book applicable to your model* to familiarize yourself on the specific items which must be adhered to such as maximum external static pressure to unit, air temperature rise, minimum or maximum CFM and motor speed connections.
TO THE OWNER
It is important to complete the owner registration card and mail it immediately. This will assist us in contacting you if any service or warranty information should change in the future. When completing the registration card, be sure to include the Model, Manufacturing and Serial Numbers, plus the installation date. The warranty certificate is also supplied with the unit. Read the war­ranty carefully and note what is covered. Keep the warranty certifi­cate in a safe place so you can find it if necessary. If additional operating instructions are required, call the dealer where the purchase was made. Keep this literature in a safe place for fu­ture reference.
UNIT PLACEMENT
WARNING
O PREVENT PROP ERTY DA MAGE, EQUIPMENT D AMAGE, PERSONAL INJURY
T
OR DEATH,
INSTALLING THE UNIT.
ALL INSTALLATIONS:
GROUND LEVEL INSTALLATIONS ONLY:
When the unit is installed on the ground adjacent to the
The base should also be located where no runoff of water
ROOFTOP INSTALLATIONS ONLY:
To avoid possible personal injury or property damage, the
If horizontal air delivery is used, the unit may be installed
To avoid possible personal injury, a safe, flat surface for
If vertical air discharge is used and the unit is installed on
This unit is approved only for an outdoor installation. To assure that your unit operates safely and efficiently, it must be installed, operated, and maintained in accordance with these installation and operating instructions, all local building codes and ordinances. The heating and cooling capacities of the unit should be greater than
THE FOLLOWING POINTS
building, a level concrete (or equal) base is recommended. Prepare a base the same physical size as the unit or slightly larger and 3 inches thick.
from higher ground can collect in the unit.
roof must have sufficient structural strength to carry the weight of the unit(s) and snow or water loads as required by local codes.
directly on wood floors or on Class A, Class B, or Class C roof covering material.
service personnel must be provided.
combustible flooring or class A, B, or C roofing material, then the Amana® brand roof curb (PRC06A1 or PRC08A1) is required.
BE OBSERVED WHEN
MUST
or equal to the design heating and cooling loads of the area to be conditioned. The loads should be calculated by an approved method or in accordance with A.S.H.R.A.E. Guide or Manual J - Load Cal­culations published by the Air Conditioning Contractors of America. Obtain from:
American National Standards Institute
1430 Broadway
New York, NY 10018
TRANSPORTATION DAMAGE
All units are securely packed in shipping containers tested accord­ing to International Safe Transit Association specifications. The car­ton should be checked upon arrival for external damage. If damage is found, a request for inspection by carrier agent should be made in writing immediately. The unit should be carefully inspected upon arrival for damage and bolts or screws which may have loosened in transit. In the event of damage, the consignee should:
1. Make notation on delivery receipt of any visible damage to shipment or container.
2. Notify carrier promptly and request an inspection.
3. In case of concealed damage, carrier should be notified as soon as possible-preferably within 5 days.
4. File the claim with the following supporting documents within the 9 month statute of limitations.
a. Original Bill of Lading, certified copy, or indemnity bond. b. Original paid freight bill or indemnity in lieu thereof. c. Original invoice or certified copy thereof, showing trade and
other discounts or reductions.
d. Copy of the inspection report issued by carrier
representative at the time damage is reported to the carrier. The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each claim. The distributor or manufacturer will not accept claims from dealers for transportation damage.
NOTE: When inspecting the unit for transportation damage, remove all packaging materials. Recycle or dispose of the packaging mate­rial according to local codes.
RIRI
RI
RIRI
GGINGGIN
GGIN
GGINGGIN
G AND HANDG AND HAND
G AND HAND
G AND HANDG AND HAND
LINLIN
LIN
LINLIN
GG
G
GG
CAUTION
O PREVENT PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT
T
POSITION DURING ALL RIGGING AND MOVING OPERATIONS.
LIFTING AND MOVING WHEN A CRANE IS USED, PLACE THE UNIT IN AN
ADEQUATE CABLE SLING.
IMPORTANT: If using bottom discharge with roof curb, ductwork
should be attached to the curb prior to installing the unit. Ductwork dimensions are shown in Amana® brand roof curb installation instruc­tions. Refer to the Roof Curb Installation Instructions for proper curb in­stallation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. NOTE: Lower unit carefully onto roof mounting curb. While rigging unit, center of gravity may cause condenser end to be lower than supply air end.
O FACILITATE
T
*NOTE: Please contact your distributor or our website for the applicable product data book referred to in this manual.
3
Loading...