Amana UC18E2, UHDC5112, UC11E2, DEC11E2, UHDC5142 Technical Information

...
International Commercial MicrowaveTechnical Information
230 V, 50 Hz Models UHDC5112 P1331234M HDC5142 P1331237M UHDC5142 P1331238M HDC5182 P1331241M UHDC5182 P1331242M DEC11E2 P1331235M UC11E2 P1331236M DEC14E2 P1331239M DEC18E2 P1331243M UC14E2 P1331240M UC18E2 P1331244M
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
Refer to Service Manual RS5320013 for detailed installation, operating, testing, troubleshooting, and disassembly instructions.
CAUTION
!
All safety information must be followed as provided in Service Manual RS5320013.
!
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor before servicing, unless testing requires power.
Models UHDC5112
UC11E2
Power Source
Voltage AC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC 230 VAC Amperage (single unit) 13 A 13 A 13 A 13 A 13 A 13 A Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Single phase, 3 wire earthed X X X X X X Plug BS 1363A CEE 7/7
Power Output Nominal microwave energy (IEC705) Minimum temperature rise (T) 11ºF/5.5ºC 11ºF/5.5ºC 14ºF/7.5ºC 14ºF/7.5ºC 18ºF/10ºC 18ºF/10ºC Operating frequency 2450 MHz 2450 MHz 2450 MHz 2450 MHz 2450 MHz 2450 MHz Power Consumption Cook condition microwave 1800 Watts 1800 Watts 2300 Watts 2300 Watts 3000 Watts 3000 Watts
Dimensions
Cabinet
Width 423 mm 423 mm 423 mm 423 mm 423 mm 423 mm Height 335 mm 335 mm 335 mm 335 mm 335 mm 335 mm Depth 548 mm 548 mm 578 mm 578 mm 578 mm 578 mm
Oven Interior
Width 331 mm 331 mm 331 mm 331 mm 331 mm 331 mm Height 175 mm 175 mm 175 mm 175 mm 175 mm 175 mm Depth 305 mm 305 mm 305 mm 305 mm 305 mm 305 mm
Weight
Crated 29 kg 29 kg 31 kg 31 kg 31 kg 31 kg
1100 Watts 1100 Watts 1400 Watts 1400 Watts 1800 Watts 1800 Watts
WARNI NG
DEC11E2 UHDC5142
UC14E2
BS 1363A CEE 7/7
Schuko
HDC5142 DEC14E2
Schuko
UHDC5182
UC18E2
BS 1363A CEE 7/7
HDC5182 DEC18E2
Schuko
November 2006 16027612
©2006 Maytag Services
1
Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration Component Testing Results
Open at 104° C (219° F). Open at 138° C (280° F) and
closed at 82° C (180° F).
Infinite resistance should be measured in one direction and 50K or more in the opposite direction.
NOTE: Analog meter must contain a battery of 6 volts minimum.
Caution - Do not operate oven when wire to terminal MT2 is removed.
Infinite. Approximately 40 or more. Infinite. Infinite.
Between Terminals: Meter should momentarily deflect towards zero then return to over 5 MΩ. If no deflection occurs, or if continuous deflection occurs, replace capacitor.
Terminal to Case: Infinite resistance.
Infinite. Between Terminals: Less than 1 Ω.
Each terminal to ground measures Infinite resistance. NOTE: This test is not conclusive. If oven does not heat and all other components test good, replace the magnetron and retest.
Approximately 30 Ω.
1100 Watt units
1400 and 1800 Watt units
MT2
MT1 GA TE
Thermal Cutout Disconnect all wires from TCO.
Diode Assembly
Triac Disconnect wires to triac.
Capacitor
Snubber Assembly Disconnect wires to snubber.
Magnetron
Blower Motor Remove all wires from motor.
Measure resistance across terminals.
Cavity Thermal Fuse..................................
Magnetron TCO .........................................
Discharge Capacitors
Remove diode lead from capacitor and connect ohmmeter.
Reverse leads for second test.
Measure resistance from:
MT1 to MT2 ...................................................
MT1 to Gate...................................................
MT2 to Gate...................................................
All terminals to ground ...................................
Discharge Capacitors
Remove wires from capacitor terminals and connect ohmmeter, set on highest resistance scale to terminals.
Also check between each terminal and capacitor case.
Measure resistance across terminals.............
Discharge Capacitors
Remove wires from magnetron and connect ohmmeter to terminals. Also check between each terminal and ground.
Measure resistance across coil......................
Line
Wire Harness Test continuity of wires .................................. Continuity.
Load
Earth
Line filter Line to Line....................................................
16027612 November 2006
Load to Load..................................................
Line to Load ...................................................
Any terminal to Earth .....................................
2
.8 M
.
.8 M
.
Continuity. Infinite.
©2006 Maytag Services
Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration Component Testing Results
This transformer is equipped with a 155° C thermal cutout.
1.3
.
1.3
.
<1
.
70
.
Infinite resistance. If not, replace transformer.
1
.
<1
.
<1
.
45
.
Infinite resistance. If not, replace transformer.
Approximately 12 K
.
COM
220
6
COM
230
230
Transformer
1100 Watt
6
5
4
(COM)
3
Discharge Capacitor
Remove all wires from terminals, and measure resistance from:
5
220 to Common...............................................
230 to Common...............................................
6
Terminal 5 to 6 ................................................
Terminal 4 to Earth screw on transformer .......
Terminal 4 to any other terminal......................
(230V)
1
Transformer
5
1800 and 1400 Watt
8
4
7
#
# 1
# 2
#
# 6 # 7
#
4
5
8
Stirrer motor 230 VAC
4
3
1
Gray Pink
Discharge Capacitor
Remove all wires from terminals, and measure resistance from:
230 to Common...............................................
Terminal 5 to 6 ................................................
Terminal 7 to 8 ................................................
Terminal 4 to Earth screw on transformer .......
Terminal 4 to any other terminal......................
Remove all wires from motor.
Measure resistance across terminals..............
Interlock switch assembly
Monito r
Primary / Logic
Secondar y
Touch Panel Assembly
Disconnect wires to switch.
With door open measure resistance from:
Terminal C to NO Primary ..........................
Terminal C to NO Secondary .....................
Terminal C to NC Monitor...........................
With door closed measure resistance from:
Terminal C to NO Primary ..........................
Terminal C to NO Secondary .....................
Terminal C to NC Monitor...........................
Door Closed
Primary / Logic
Monitor
Secondary
C
C
C
NO
NC
NO
Continuity is indicated as 100 and below.
Pin 1: Ground.
10 9
8
7
6
5
4
3
2
1
Split
Infinite. Infinite. Continuity.
Continuity. Continuity. Infinite.
Pad 1 2 3 4 5 6 7 8 9 0 Start Stop/Reset Power Level X 2 Time Entry
Trace
8 & 10 7 & 10 6 & 10 5 & 10 4 & 10 3 & 10 8 & 9 7 & 9 6 & 9 5 & 9 4 & 9 4 & 8 5 & 8 6 & 8 7 & 8
Measurement
Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity
November 2006 16027612