•Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
•All safety information must be followed as provided in the Service Manual.
•Refer to the appropriate Parts Catalog for part number information.
•Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
C: Condenser R-22
X: Condenser R-410A
H: Heat Pu mp R- 22
Z : Heat Pu m p R-41 0A
MAJOR REVISI ON:
A: Initial Release
NOM INAL
CAPACITY
018 : 1.5 T ons
024 : 2 Tons
030 : 2.5 t ons
036 : 3 Tons
042 : 3.5 T ons
048 : 4 Tons
060 : 5 tons
WARNING
WARNING
WARNING
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
2
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
WARNING
HIGH VOLTAGE!
WARNING
WARNING
viduals meeting (at a minimum) the requirements of an
"entry level technician", at a minimum, as specified by the
Air-Conditioning, Heating, and Refrigeration Institute (AHRI).
Attempting to install or repair this unit without such background may result in product damage, personal injury or
death.
Installation and repair of this unit
should be performed
ONLY by indi-
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
* Indicates minor revision & is not used for order entry or inventory management
WARNING
WARNING
WARNING
WARNING
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
WARNING
WARNING
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
To prevent the risk of property
damage, personal injury, or death,
3
PRODUCT DESIGN
ASX14 models are available in 1 1/2 through 5 ton sizes and
use R-410A refrigerant. They are designed for 208/230 volt
single phase applications.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet.
These units are designed for free air discharge, so no additional resistance like duct work shall be attached.
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. ASX units
are charged for the matching evaporator coil and a 15 foot
refrigerant line set.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space.
ASX models use the Copeland Scroll "Ultratech" Series compressors which are specifically designed for R-410A refrigerant. There are a number of design characteristics which are
different from the traditional reciprocating and/or scroll compressors.
"Ultratech" Series scroll compressors will not have a discharge thermostat, some of the early model scroll compressors required discharge thermostats.
Due to their design Scroll compressors are inherently more
tolerant of small quantities of liquid refrigerant.
NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued
floodback or flooded start conditions may wash oil from the
bearing surfaces causing premature bearing failure.
"Ultratech" Series scroll compressors use "POE" or
polyolester oil which is NOT compatible with mineral oil based
lubricants like 3GS. "POE" oil must be used if additional oil
is required.
Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section.
completely unobstructed; however, if vertical conditions require placement beneath an obstruction there should be a
minimum of 60 inches between the top of the unit and
the obstruction(s). The specified dimensions meet require-
ments for air circulation only. Consult all appropriate regulatory codes prior to determining final clearances.
Another important consideration in selecting a location for
the unit(s) is the angle to obstructions. Either side adjacent
the valves can be placed toward the structure provided the
side away from the structure maintains minimum service clearance. Corner installations are strongly discouraged.
DO NOT locate the unit:
–Directly under a vent termination for a gas appliance.
–Within 3 feet of a clothes dryer vent.
–Where the refreezing of defrost water would create a
hazard.
–Where water may rise into the unit.
NOT
RECOMMENDED
BBB
AAAAA
C
AA
A
Model TypeABCAA
Residential
Light Commercial12"12"18"24"
AA
Minimum Airflow Clearance
C
AA
AA
CC
10"10"18"20"
B
AA
OK!
OK!
OK!
OK!
OK!
OK!
WARNING
To avoid possible injury, explosion or death, practice
safe handling of refrigerants.
Special consideration must be given to location of the condensing unit(s) in regard to structures, obstructions, other
units, and any/all other factors that may interfere with air
circulation. Where possible, the top of the unit should be
4
PRODUCT DESIGN
A
DIMENSIONS
H
D
W
ModelDimensions - W x D x HModelDimensions - W x D x H
ASX140181A*26" x 26" x 32¼"ASX140361A*29" x 29" x 34¼"
ASX140181B*
ASX140181C*
ASX140181D*
ASX140241A*26" x 26" x 32½"ASX140421B*29" x 29" x 38¼"
ASX140241B*
ASX140241C*
ASX140301A*29" x 29" x 32¼"
ASX140301B*
R.L. Amps9 .0013 .412.814.1
L.R. Amps4 8.058 .364. 077.0
Low Pr es s ure Switch
Open
Close
High Pressure Switch
Open
Close
Co ndenser Fan Mot or
Horsepower1/121/121/61/4
F.L . A mps0.60.61.51.6
Liquid Li ne, Inc hes O.D.*3/8"3/8"3/ 8"3/8 "
Sucti on Li ne, In ches O .D.*3/4"3/4"3/4"7 / 8"
Refrigerant Charge121.0126.0131.0146.0
Po we r S upply208/230-60-1208/230-60-1208/230-60-1208/230- 60-1
Minimum Circuit Ampacity
Maximum Overcurrent De vice
(1)
(2)
Electrical Conduit Size
Po we r S upply (Inches )1/2 or 3/41 /2 or 3/41/2 or 3/ 41 /2 o r 3/4
Approximate Shipping Weight178178195199
Low Pressure Switch
Open
Close
High Pressure Switch
Open
Close
Condenser Fan Mot or
Horsepower1/41/41/41/4
F.L . Amps1.61.61.61 .6
Liquid Line, Inches O.D.*3/8"3/8"3/8"3/8"
Suction Line, Inches O.D.*7/8"7/8"7/8"7/8"
Refrigerant Charge
Po wer S upply208/23 0- 60-1208/230 -6 0-1208/ 230-60 - 1208/2 30- 60-1
Minimum Ci rcuit A m
Maximum Overcurrent De vice
Electrical Conduit Size
Po wer S upply (Inches)1/2 or 3/ 41/2 or 3/ 41/ 2 or 3/41/2 or 3/4
Appr o x im ate S hip ping W ei ght2 072422 4 2280
acit
(1)
(2)
17.919.819.826.4
112.0109.0109.0134.0
22 PSIG
50 PSIG
610 PSIG
420 PSIG
180.0186.0189.0271.0
24.026.426.434.6
40404060
ASX140481
AA/AB/AC
22 PSIG
50 PSIG
610 P SIG
420 P SIG
ASX140481
AD/B
22 PSIG
50 PSIG
610 PSIG
420 PSIG
ASX140601A*
ASX140601B*
22 PSIG
50 PSIG
610 P SIG
420 P SIG
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
Low Pressure Switch
Open
Clos e
High Pressure Switch
Open
Clos e
Co ndenser Fan M otor
Horsepower1/61/61/4
F.L. Amps1.00.91.5
Li quid Line, Inches O.D.*3/8"3/8"3/ 8"
Sucti on Line, Inches O.D.*7/8"7/8"7/8 "
Refrigerant Charge
Power Supply208/230-60-1208/230-60-1208/230-60-1
(1)
Minimum Circuit Am
Maximum Ove rcurr ent Device
acit
(2)
Electr ical Conduit Size
Power Supply (Inches)1/ 2 or 3/41 /2 or 3/ 41/2 or 3/ 4
App r ox i m ate S hip ping W e i ght
17.916.719.9
112.079.0109.0
22 PSIG
50 PSIG
610 PSIG
420 PSIG
22 PSIG
50 PSIG
6 10 P S IG
4 20 P S IG
22 PSIG
50 PSIG
610 PSIG
420 PSIG
167.0140.0147.0
23.421.826.4
403545
207
184
230
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in
accordance with National Electrical
Codes; extensive wire runs will
require larger wire sizes.
(2)
Maximum Overcurrent Protection
Device: MUST use Time Delay
Fuses or HACR type Circuit Breaker
of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
7
CONDENSING UNIT SPECIFICATIONS
ASX140181D*/ ASX140421D*
ASX140181D*ASX140421D*
Cooling Capacity, BTUH18,00040,000
Compressor
R.L. Amps9.00
L.R. Amps4 8.0
Lo w P r ess ure S wit c h
Open
Close
N/A
N/A
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
Co ndenser Fan Motor
Horsepower1/81/6
F.L . Am ps0.70 .9
Liqu id Line, In c hes O.D.*3/ 8"3/ 8"
Suction Line, Inc h es O.D .*3/ 4"7/8"
R efriger a n t Ch ar ge73.0
Power Supply2 08/230- 60-1208/230 -60- 1
Minimum Circuit Ampacity
(1)
Maximum Overcurr ent De vice
(2)
12
20
Electrical Conduit Size
Power Supply (Inches)1/2 or 3/41 /2 or 3/4
Approximate Shipping Weight146184
16.7
79.0
22 PSIG
50 PSIG
610 PSIG
420 PSIG
140.0
21.8
35
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.