Amana AGR4422VD User Manual

30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
CABINET OPENING DIMENSIONS
AGR4422VD
Gas supply: Use 3/4" (1.9 cm) rigid pipe gas supply line to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal appliance connector, design-certified by CSA, 4-5 feet (122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., be used for connecting the range to the rigid gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. Pipe joint compounds that resist the action of LP gas must be used. Do not use TEFLON
®†
tape. An individual manual shutoff valve must be located in the same room, but external to the range.
Electrical: A 120-volt, 60-Hz, AC-only, electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10153329
09-04-08
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height.
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
26 3/4"
(67.9 cm)
24
1
/4"
(61.6 cm)
29
7
/8"
(75.9 cm)
36"
(91.4 cm)
46
1
/4"
(117.5 cm)
A
B
C
D
E
F
G
G
H
I
J
K
K
L
M
A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*. E. 30¹⁄₈" (76.5 cm) min. opening width
F. This shaded area recommended for installation of rigid gas
pipe. G. 8" (20.3 cm) H. Grounded outlet
I. 17" (43.2 cm)
J. 4¹⁄₂" (11.4 cm)
K. 2" (5.1 cm)
L. 2" (5.1 cm) min. clearance from both sides of range to side
wall or other combustible material.
Loading...