ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
GAS SUPPLY REQUIREMENTS
Type of gas
Natural gas:
This range is factory set for use with Natural gas. The model/serial rating plate is located on the left side of the bottom of the broiler and has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
Gas Supply Line
■ Provide a gas supply line of
location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be 1/2" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.
Flexible metal appliance connector:
■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122
to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D. flexible metal appliance connector may be used for connecting range to the gas supply line.
1
■ A
/2" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the
range.
■ Must include a shut-off valve:
The supply line must be equipped with a manual shut-off valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shut-off valve. The valve is for turning on or shutting off gas to the range.
3
/4" (1.9 cm) rigid pipe to the range
B
PRODUCT DIMENSIONS
D
A
C
B
A. 36" (91.4 cm) B. 297/8" (75.9 cm) C. 257/64" (63.8 cm) D. 475/64" (119.6 cm)
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
A. Gas supply line B. Shut-off valve open position C. To cooktop
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
Ref. W10821262A
12/19/2016
CABINET OPENING DIMENSIONS
B
C
A
E
H
I
J
F
M
L
N
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
D
G
K
L
If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond cabinet fronts by 1/2" (1.3 cm) minimum.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop B. 13" (33.0 cm) max. upper cabinet depth C. 30" (76.2 cm) min. cabinet opening width D. For min. clearance to top of cooktop, see NOTE.* E. 301/8" (76.5 cm) min. opening width F. This shaded area recommended for installation of electrical outlet. G. This shaded area recommended for installation of rigid gas pipe. H. 2" (5.1 cm) min. countertop space to side wall or other combustible
material I. 24" (61.0 cm) J. 10" (25.4 cm) K. 8" (20.3 cm) L. 5" (12.7 cm) M. 2" (5.1 cm) N. 3" (7.6 cm)
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 2 of 2