Amana AGR3311WD User Manual

Freestanding Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10130752
7-01-09
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height.
For minimum clearance to top of cooktop, see NOTE
.
This shaded area
recommended for
installation
of gas pipe.
This shaded area
recommended for
electrical outlet.
18" (45.7 cm) min. clearance upper side cabinet to countertop
13" (33.0 cm) max. upper cabinet depth
30-¹₈
" (76.5 cm)
opening width
30" (76.2 cm) min. cabinet opening width
8"
(20.3 cm)
2"
(5.1 cm)
3"
(7.6 cm)
5"
(12.7 cm)
5"
(12.7 cm)
10" (25.4 cm)
2" (5.1 cm) min. countertop space to side wall or other combustible material
24"
(61.0 cm)
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
®
AGR3311WD
Gas supply:
Use 3/4" (1.9 cm) rigid pipe gas supply line to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by CSA, 4-5 feet (122-152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., be used for connecting the range to the rigid gas supply line. A 1/2" (1.3 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. An individual manual shutoff valve must be located in the same room, but external to the range.
Electrical: 120-volt, 60-Hz, AC only, electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
"
26-3/4 (67.9 cm) depth with handle
24-1/4
(61.6 cm)
"
36
(91.4 cm)
top
cook
height
"
42
6.7 cm)
(10
l
overal
ht
heig
" (75.9 cm)
"
29-7/8
width