Amana AGR3300XD User Manual

Gas Range
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
AGR3300XD
Natural gas:
This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on
the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection. All strains must be removed from the supply and fuel lines so range will be level and in line.
Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10325493A
1/17/11
29⁷⁄₈" (75.9 cm)
42"
(106.7 cm)
24¹⁄₄"
(61.6 cm)
36"
(91.4 cm)
26³⁄₄"
(67.9 cm)
GAS SUPPLY REQUIREMENTS
INSTALLATION CLEARANCES
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend beyond cabinet fronts by ¹⁄₂" (13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
IMPORTANT: Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking and self-cleaning. Check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
†®
TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.
B
D
C
A
E
G
K
F
J
I
H
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*. E. 30¹⁄₈" (76.5 cm) min. opening width
F. 17" (43.2 cm) G. This shaded area recommended for installation of rigid gas pipe. H. 2" (5.1 cm)
I. 4" (10 cm)
J. 2" (5.1 cm)
K. 2" (5.1 cm) min. clearance from both sides of range to side wall
or other combustible material.