20" (50.8 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
AGP200VD
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10459120A
5/11/12
19¹⁄₂"
(49.5 cm)
24¹⁄₂"
(62.2 cm)
42"
(106.7 cm)
36"
(91.5 cm)
Natural gas:
This range is design-certified by CSA International for use with Natural gas or,
after proper conversion, for use with LP gas.
●
This range is factory set for use with Natural gas. See “Gas Conversions”
section. The gas information plate (located behind the warming or storage
drawer on the side of the oven frame or on the side of the bottom oven frame,
depending on your model) has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas available, check
with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified on
the model/serial rating plate for use with a different gas without consulting the
serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
●
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A
smaller size pipe on longer runs may result in insufficient gas supply. With LP
gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas
suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used.
Do not use TEFLON®†tape.
Flexible metal appliance connector:
●
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm)
long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
●
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe
threads of the inlet to the appliance pressure regulator.
●
Do not kink or damage the flexible metal tubing when moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to
obtain an in-line connection to the range. The rigid pipe must be level
with the range connection. All strains must be removed from the
supply and fuel lines so range will be level and in line.
●
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve
should be located in the same room but external to the range opening, such
as an adjacent cabinet. It should be in a location that allows ease of opening
and closing. Do not block access to shutoff valve. The valve is for turning on
or shutting off gas to the range.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
GAS REQUIREMENTS
A
B
A. Gas supply line
B. Shutoff valve “open” position
C. To range
C
CABINET OPENING DIMENSIONS
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop
B. 13" (33.0 cm) max. upper cabinet depth
C. 20" (50.8 cm) min. cabinet opening width
D. For minimum clearance to top of cooktop, see NOTE.
E. 20
¹⁄₈
" (51.1 cm) min. opening width
F. This shaded area recommended for installation of electrical outlet.
G. This shaded area recommended for installation of gas pipe.
H. 3" (7.6 cm) min. countertop space to side wall or other
combustible material
I 24" (61.0 cm)
J. 10" (25.4 cm)
K. 5
¹⁄₂
" (14 cm)
L. 4" (10 cm)
M. 2" (5.1 cm)
N. 2
¹⁄₂
"(6.4cm)
A
B
C
D
E
F
G
H
J
K
M
L
L
N
I
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
If the cabinet depth is greater than 24" (61.0 cm), oven frame must
extend beyond cabinet fronts by ¹⁄₂" (1.3 cm) minimum.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above
the cooktop surface.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10459120A
5/11/12
Page 2 of 2