W11326823A
WARNING
FOR SERVICE TECHNICIAN’S USE ONLY
ACTIVATING THE SERVICE DIAGNOSTIC MODES
1. Enter Diagnostics Mode by pressing CANCEL>CANCEL>START within 5
seconds.
2. Press the “up” arrow keypad to scroll through the diagnostics settings.
© 2019
NOTES:
■ Entering Diagnostics mode will cancel any active oven operation.
■ Enter the Diagnostics mode only after the oven is cool.
Electrical Shock Hazard
Only authorized technicians should
perform diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Electrical Shock Hazard
result in death or electrical shock.
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
■ Verify the controls are in the off position so that the appliance does not start when energized.
■ Allow enough space to perform the voltage measurements without obstructions.
■ Keep other people a safe distance away from the appliance to prevent potential injury.
■ Always use the proper testing equipment.
■ After voltage measurements, always disconnect power before servicing.
ERROR CODES
Code Description
No display Control not operational
F1E0
F1E1
F1E2
F2E1 Shorted keypad
F3E0 Oven sensor opened
F5E0 Door and switches do not agree (Clean mode)
F5E1 Door latch not operating (Clean mode)
F6E1 Oven over temperature when heating
F9E0 Miswired house
Internal board failure
A/D Error(s)
Oven sensor shorted
Bake/Broil range over temperature
Clean range over temperature
Miswired range
RESISTANCES
Component Pinout Resistance or Voltage
Door switch P3-1 to P3-2 2 VDC with door open
Oven temp sensor P3-4 to P3-5 1000-1200 Ω at room temperature.
Oven light P2-1 to WH (neutral) P1-3 0-40 Ω nominal
Bake element P4-3 to P5-4 10-40 Ω nominal
Broil element P5-1 to P5-4 10-40 Ω nominal
Thermo fuse P5-1 to P5-4 240 VAC
Door latch motor P3-3 to WH (neutral) P1-3 500-3000 Ω
Radiant element (single) H1 to H2 240 VAC
Radiant element (dual) H1A to H2 240 VAC
Coil element H1 to H2 240 VAC
0 VDC with door closed
W11326823A
FOR SERVICE TECHNICIAN’S USE ONLY
IMPORTANT: Electrostatic discharge may cause damage to machine control electronics. Refer to online Tech Sheet for additional information.
Check for proper voltage by completing the following steps:
1. Disconnect the power or unplug the appliance.
2. Connect voltage measurement equipment to proper connectors.
3. Plug in appliance or reconnect power and conrm voltage reading.
4. Disconnect the power or unplug the appliance.
WIRE DIAGRAM
COOKTOP OVEN
© 2019
L1
BK
L1
BK
L1
BK
L1
BK
Cooktop Infinite
Switches
Heater
LR
H1
Heater
H2
LF
H1
Heater
H2
L2
RR
H1
H2
L2
L2
P
BK
WH
Oven Control LCX 1.0
L2
HIB
VT
VT
YL/BK
YL
1200 W (LR)
VT
VT
P10-1
P10-2
P
P
Membrane
Keypad
Main Oven Temp
Sensor (RTD)
1800 W (LF)
OR/BK
P3-5
RTD Oven
VT
P3-4
RTD Common
VT
P3-2
Switch Common
YL
P3-1
YL
P11
Keypad
Power Supply
Cooktop
Feedback
Bake (P4)
OR
VT
1800 W (RR)
P4-1
DLB (P6)
P5-4
K1
P5-1
Broil (P5)
P5-3
K2
P4-3
P4-4
K3
P2-6
P2-1
K4
P1-1
Power In (P1)
P1-3
P10-1
P10-2
WH
BK
RD
RD
BU
BK
BK
BK
BK
WH
Broil 3400 W
Bake 2400 W
Oven Light 40 W
Thermo Fuse
Opens at 363°F (184°C)
RD
RD
BU/BK
BU
RD
BK
L1
Heater
H1
H2
L2
RF
VT
P
1200 W (RF)
BR/BK
BR
RD