Amana AEP222VAW0, AEP200VAW0, CE11000VAV0, TEP200VAQ0, TEP222VAB0 Installation Guide

...
INSTALLATION INSTRUCTIONS
20" (50.8 CM) FREESTANDING ELECTRIC RANGE
withStandardClean Oven
INSTRUCCIONES DE INSTALACION
ESTUFA ELI_CTRICAAUTONOMA DE 20" (50,8 CM)
con homo de limpieza est_ndar
Table ofContents/Indice
RANGE SAFETY ............................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 2
INSTALLATION INSTRUCTIONS .................................................. 5
Verify Anti-Tip Bracket Location ................................................ 12
Level Range ................................................................................ 12
Complete Installation ................................................................. 12
Check Operation ........................................................................ 12
SEGURIDAD DE LA ESTUFA ....................................................... 13
REQUlSITOS DE INSTALACION ................................................. 14
Piezas y herramientas ................................................................ 14
Requisitos de ubicacion ............................................................. 14
Requisitos electricos .................................................................. 15
INSTRUCCIONES DE INSTALACION ......................................... 17
Desempaque la estufa ............................................................... 17
Instalacion del soporte anti-vuelco ............................................ 17
Conexion electrica ...................................................................... 19
Verificacion de la ubicacion del soporte anti-vuelco ................. 24
Nivelacion de la estufa ............................................................... 24
Complete la instalacion .............................................................. 24
Verifique el funcionamiento ........................................................ 24
iMPORTANT:
Save for local electrical inspector's use.
IMPORTANTE:
Guarde para tenerlas a disposici6n del inspector de electricidad local.
W10175654B
RANGESAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Parts supplied Read and follow the instructions provided with any tools listed Check that all parts are included.
here. Tools needed
Tape measure Masking tape
Flat-blade screwdriver Wire strippers
Phillips screwdriver 3/8"nut driver
Level 1/8"(3.2 mm) drill bit
Hammer (for wood floors)
Hand or electric drill 3/16"(4.8 mm) carbide-
Wrench or pliers (for concrete/ceramic
Marker or pencil floors)
tipped masonry drill bit
A. Anti-tip bracket B. Plastic anchors (2)
C. #10 x 1Y2" screws (2)
B
/
f
S
Anti-tip bracket must be securely mounted to subfloor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware
store.
2
Parts needed If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 13/8"(3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See "Electrical Requirements" section.
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on under the left front
burner bowl.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
Product Dimensions
A. Model/serial rating plate
The range should be located for convenient use in the kitchen.
Recessed installations must provide complete enclosure of the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets. Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances. The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C).
Use an insulated pad or 1¼,,(0.64 cm) plywood under range if installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
A D
C
A. 36" (91.5 cm)
B. 19V2" (49.5 cm) C. 24V2" (62.2 cm) D. 42" (106. 7 cm)
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61.0 cm), the oven frame must extend beyond cabinet fronts by 1/2"(13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or
microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A
G
J J
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance
with local codes. Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances. A copy of the above code standards can be obtained from:
National Fire Protection Association One Batterymarch Park
Quincy, MA 02269 WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located under the front left burner bowl. Refer to the figure in the "Location Requirements" section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire UL listed, 40- or 50- amp power supply cord (pigtail) (see Range Rating chart below). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
A. 18" (45.7 cm) min. clearance
upper side cabinet to countertop
B. 13" (33.0 cm) max. upper
cabinet depth
C. 20" (50.8 cm) min. cabinet
opening width
D. 20 _" (51.1 cm) opening width
E.5" (12.7 cm) min. countertop
space to side wall or other
combustible material
F. For minimum clearance to top
of cooktop, see NOTE.
G. Wall receptacle - 8" (20.3 cm)
from either cabinet,
H. 57/2''(14.0 cm) max. from floor.
Locate 120/240-volt receptacle in shaded area.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1¼,,(0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.0- 16.5 KW 6.0- 12.5 KW 40 or 50"*
16.6 - 22.5 KW 12.6 - 18.5 KW 50 *The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8"(34.93 mm) diameter connection opening.
A circuit breaker is recommended. The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See "Electrical
Connection."
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range (40 amps).
The wiring diagram is located on the underside of the storage drawer or below the warming drawer in a clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the
cabinet. See "Electrical Connection." Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
@
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors
1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250 volt, 40-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
INSTALLATIONINSTRUCTIONS
Unpc c Sc ag÷
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. Do not use oven door handle to lift or move the range.
2. Remove shipping materials, tape and film from range. Keep cardboard bottom under range. Remove oven racks and parts package from inside oven.
3. Take 4 cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with the other
2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back. Using 2 or more people, firmly grasp the range and gently lay it on
its back on the cardboard corners.
4=
Pull cardboard bottom firmly to remove.
5.
Use a wrench or pliers to loosen the leveling legs. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A maximum of 3Ae"(5.0 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.
6=
Place cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto cardboard or
hardboard.
Y!_. _;/*_ - .....
/_>_ ._ ..... _°_._ '-_
]i ![
A ................................4_ /-/
A. Cardboard shipping base
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket, if the range is moved. Failure to follow these instructions can result in death
or serious burns to children and adults.
Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering.
Before moving range, slide range onto shipping base, cardboard or hardboard.
1. Remove template from the anti-tip bracket kit (found inside the oven cavity).
2. Place template on the floor in cabinet opening so that left edge is against cabinet and top edge is against rear wall, molding or cabinet. 3
3. Tape template into place.
4. If countertop is not flush with cabinet opening edge, align template with overhang.
6=
Tap plastic anchors into holes with a hammer.
7.
Align the anti-tip bracket holes with the holes in the floor. Fasten the anti-tip bracket with the screws provided. Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the subfloor. Longer screws are available from your local hardware store.
8. Move the range close to the opening to allow for electrical connections to be made. Remove the shipping base, cardboard or hardboard from under the range.
9. Use a wrench or pliers to lower the front leveling legs one-half turn.
A. Rear leveling leg B. Front leveling leg
10. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of 3/16"(5.0 mm) is needed to engage the anti-tip
bracket.
11. Move the range into final location making sure the rear leveling leg slides into the anti-tip bracket.
If cabinet opening is wider than that specified in the "Location Requirements" section, adjust template so range will be
centered in cabinet opening.
5=
To mount anti-tip bracket to wood floor, drill two V8" (3.2 mm) holes at the positions marked on the bracket template.
Remove template from floor. To mount the anti-tip bracket to a concrete or ceramic floor,
use a 3/16"(4.8 mm) masonry drill bit to drill 2 holes at the positions marked on the bracket template. Remove the
template from the floor.
6
12. If installing the range in a mobile home, you must secure the range to the floor. The method of securing the range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use
the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501 A or with local codes.
13. Continue installing your range using the following installation instructions.
Power Supply Cord Direct Wire
Electrical Shock Hazard
Disconnect power before servicing. Use a new 40 amp power supply cord.
Plug into a grounded outlet. Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
Disconnect power
2.
Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove
cover.
o
A. Hold-down screws B. Terminal block cover
Electrical Shock Hazard
Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range. Failure to follow these instructions can result in death,
fire, or electrical shock.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and rotate/
conduit plate 180°.
3.
Add strain relief. Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
B
A. UL listed strain relief - large opening B. Small opening
Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
A
A.Largeopening B.Small opening
Position cord/conduit plate as shown in the following illustration.
A. Small opening B. Large opening
Replace cord/conduit plate and insert screws.
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed, 4-wire connection: (NEMA type 14-50R) 250-volt Power supply cord
, (
! I ! I
A. Small opening B. Large opening
Assemble a UL listed conduit connector in the opening.
.. ::9-._.
I......................... t
A. Removable retaining nut - small opening B. Conduit connector
C. Large opening
Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
40-amp, range minimum,
power supply cord
4-wire direct A circuit breaker 4-wire connection:
box or fused Direct wire disconnect
(12.7 cm)
3-wire receptacle A UL listed, (NEMA type 10-50R) 250-volt
3-wire connection: Power supply cord
minimum,
C._ 40-amp, range
power supply cord
3-wire direct A circuit breaker 3-wire connection:
1" box or fused Direct wire
disconnect
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the neutral
1. Part of metal ground strap must be cut out and removed.
4.
Replace back panel and screws on rear of range.
5.
Complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
8
A B
C
_,, _........
A. Metal ground strap B. Discard
C. Ground-link screw
2.
Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw and the end of the ground-link under the screw.