Amana AEP200VA, AEP222VA Dimension Guide

20" (50.8 cm) Freestanding Electric Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
AEP222VA AEP200VA
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
CABINET OPENING DIMENSIONS
3/19/13
Cabinet opening dimensions shown are for: 25" (63.5 cm) countertop depth
24" (61.0 cm) base cabinet depth 36" (91.4 cm) countertop height
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or metal cabinet.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Electrical Requirements:
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located under the front left burner bowl. Refer to the figure in the “Location Requirements” section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire UL listed, 40- or 50-amp power supply cord (pigtail) (see Range Rating chart below). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.0 - 16.5 KW 6.0 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50 *The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord
with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.93 mm) diameter connection opening.
A circuit breaker is recommended.
A
A
B
D
C
A. 36" (91.5 cm) B. 19½" (49.5 cm) C. 24½" (62.2 cm) D. 42" (106.7 cm)
B
C
D
A
E
G
G
H
. 18" (45.7 cm) min. clearance
upper side cabinet to countertop
B. 13" (33.0 cm) max. upper
cabinet depth
C. 20" (50.8 cm) min. cabinet
opening width
D. 20
" (51.1 cm) opening width
¹⁄₈
E. 5" (12.7 cm) min. countertop
space to side wall or other combustible material
F. For minimum clearance to top
of cooktop, see NOTE.
G. Wall receptacle - 8" (20.3 cm)
from either cabinet,
H. 5½" (14.0 cm) max. from floor.
Locate 120/240-volt receptacle in shaded area.
F