20" (50.8 cm) Freestanding Electric Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
AEP222VA AEP200VA
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Electrical Requirements: If codes permit and a
separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path
is adequate and wire gauge is in accordance with local
codes.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.0 - 16.5 KW 6.0 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
*The NEC calculated load is less than the total connected
load listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated
cord with kit. For 50-amp rated cord kits, use kits that
specify use with a nominal 1³⁄₈" (34.9 mm) diameter
connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable.
The model/serial rating plate is located under the left front
burner bowl.
CABINET OPENING DIMENSIONS
Ref. W10175654B
12/20/10
Cabinet opening dimensions shown are for:
25" (63.5 cm) countertop depth
24" (61.0 cm) base cabinet depth
36" (91.4 cm) countertop height
IMPORTANT: If installing a range hood or microwave
hood combination above the range, follow the range hood
or microwave hood combination installation instructions
for dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or
metal cabinet is covered by not less than ¹⁄₄" (0.64 cm)
flame retardant millboard covered with not less than No.
28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood
or metal cabinet.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is
to be provided, the risk can be reduced by installing a
range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinets.
A
B
A. 36" (91.5 cm)
B. 19½" (49.5 cm)
C. 24½" (62.2 cm)
D. 42" (106.7 cm)
C
D
A
. 18" (45.7 cm) min. clearance
upper side cabinet to
countertop
B. 13" (33.0 cm) max. upper
cabinet depth
C. 20" (50.8 cm) min. cabinet
opening width
D. 20
¹⁄₈
" (51.1 cm) opening width
E
G
H
E. 5" (12.7 cm) min. countertop
F. For minimum clearance to top
G. Wall receptacle - 8" (20.3 cm)
H. 5½" (14.0 cm) max. from floor.
C
B
G
space to side wall or other
combustible material
of cooktop, see NOTE.
from either cabinet,
Locate 120/240-volt
receptacle in shaded area.
D
F