Thru-wall Installation Instructions
for Amana Compact Room Air Conditioner
Introduction
Amana Compact Room Air Conditioners can be installed
through a wall or in a window. Window installations require
an Instant Mount Mounting Kit (model number RAWK1).
Window mounting kits can be purchased from Authorized
Amana Dealers.
This instruction sheet provides guidelines for installing air
conditioner through an outside wall.
CAUTION
Installing air conditioner through a wall requires
extensive carpentry and/or masonry experience.
Through wall installations performed by inexperienced
or unqualified individuals can result in costly damage
to home.
Air Conditioner Dimensions
The following figures show the outside dimensions of air
conditioner with chassis installed, and dimensions of outer
case with chassis removed. Dimensions shown are with
the top rail removed (bottom rail on case is permanently
attached and is included in height dimensions).
16½"
11¾"
Front of
outer case
3
9
/8"
23¾"
1
/8"
23
Bottom rail
25½"
7
/8"
24
Air Conditioner Dimensions
(with chassis installed)
5
/8"
1"
Outer Case Dimensions
(chassis removed)
General Instructions
All Amana Compact Room Air Conditioners feature a slideout chassis. Chassis must be removed from outer case for
installation.
A finished opening 24¼-inches wide x 17-inches high is
recommended (this provides a finished opening ¼-inch
larger than the outer case on all sides). The lower left
inside corner of opening must be within 5 feet of an
appropriate electrical outlet (see Use and Care manual for
air conditioner electrical requirements.)
When wall thickness exceeds 93/8-inches, opening must be
modified to allow air to enter side louvers on case (see
special instructions on back ). Do not install air conditioner
in walls thicker than 1 1¾-inches.
June 1998
Back of case (outdoor side) must be at least 3/8-inch lower
than front of case to ensure proper condensate drainage.
Ensure case has proper slope before securing in place.
17"
24¼"
Electrical outlet must
be located within 5-feet
of this point.
Dimensions of Finished Opening
Masonry Construction
In masonry walls, cut or build a finished opening 17-inches
high by 24¼-inches wide. Secure outer case in wall with
mortar or concrete nails driven through holes in sides of
outer case (predrill holes in case before securing).
Brick Veneer or Frame W all Construction.
Cut or build rough opening large enough to allow a framed,
finished opening 17-inches high and 24¼-inches wide.
Secure outer case to framing material with nails or screws
driven through holes in sides of outer case (predrill holes in
case before securing).
Framing
lumber
17"
Outercase must project
a minimum ¾"
beyond inside wall
or molding to attach front frame
Lintel and
flashing
(if required)
Install case
3
/8"
with
slope to outside
for condensate
drainage
Caulk all
sides
93/8"
Front of outer case
to side air louvers
Optional
molding
(not provided)
Installed Case
(brick veneer or frame wall construction shown)
Installation in Wall Thicker Than 93/8-inches
The side louvers in outer case provide ventilation to air
conditioner compressor and fan motor and must not be
blocked. When installing unit in a wall over 93/8-inches
thick, provisions must be made in wall opening to ensure
free air flow to the side louvers. This can be accomplished
by chamfering the vertical portions of the outside opening
as shown.
Ventilation louvers on top of case must not be obstructed.
Do not attempt to install unit in walls thicker than
1 1¾-inches.
Front of
outercase
¾" minimum
projection
24¼"
93/8"
11¾"
Framed/Finished Opening
(brick veneer or frame wall construction)
Side air
louvers
Placement of Outer Case in Opening
Center outer case in finished opening. Front of case must
project ¾-inch (minimum) beyond inside wall in order to
attach air conditioner front frame.
If framing indoor side of finished opening with wood molding
4"
23¾"
31¾"
Chamfering Walls Thicker Than 93/8-inches
(top view)
(both sides)
4"
(or other decorative material), outer case must extend
¾-inch (minimum) beyond molding in order to attach air
conditioner front frame.
Part No. 20070203 ©1998 Amana Appliances