Amana 7M11TA-P1214602R, 7M11TA-P1214606R Owner’s Manual

Quiet Zone
Use And Care
Room Air Conditioner
Contents
Electrical Requirements ........................................ 2
Electrical Grounding Instructions.................................. 2
Safety Features ...................................................... 2
Compressor Lockout ..................................................... 2
Low Voltage Protection .................................................. 2
Advantages of Amana's Electronic Controls ....... 2
Operation ................................................................ 3
Vent Control ................................................................... 3
General Information .............................................. 6
Changing Air Flow Direction.......................................... 6
Air Flow Around Unit ...................................................... 6
Care and Maintenance .......................................... 6
Air Filter ......................................................................... 6
Before Calling For Service ................................... 7
Fan Motor....................................................................... 7
Slide out Chassis........................................................... 7
Model Identification .............................................. 8
Any Questions? ...................................................... 8
Manual
Please read this Use and Care Manual thoroughly. This manual provides proper maintenance information for maxi-
mum benefit of the features selected.
_ RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
As an ENERGY STAR ® partner, AMANA APPLIANCES has determined that models
5M11TA, 5M 11TB, 7M 11TA, and 18M23TB meet the ENERGY STAR ® guidelines for energy efficiency.
WARNING
To avoid death, personal injury or property damage due to overheating, do
not leave this room air conditioner unattended when used as cooling or life
support for persons or animals unable to reactto unit failure. Take precautions to
warn or guard against such an occurrence.
April 2000
Electrical Requirements
Electrical Grounding Instructions
This appliance is equipped with athree-pro nggrounding plug fer protection against possible shock hazards. Ifatwe-prong
wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall
receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical
Code. Room air conditioners aredesigned to operate according to
requirements on the nameplate and as shown in Table 1. Fuse or circuit breaker ratings must be according to the fuse
instruction label and as shown in Table 1. Do not plug models marked "Use on Single Outlet Circuit Only" into a
circuit with another appliance or light fixture.
i _i WARNING
To avoid death, personal injury or property damage due to electrical shock, this unit
must be grounded. Do not under any circumstances cut or remove the round
grounding prong from the plug. Do not use a two-prong adapter.
Safety Features
This room air conditioner is equipped with an electronic control to improve comfort and ensure reliability.
Compressor Lockout
To extend the life of the compressor a three minute time delay will occur when:
Electrical power is first supplied to the unit The thermostat is turned down immediately after the
compressor stops running, The Fan Control is quickly turned from FAN ONLY to
COOLING mode or vice versa.
Low Voltage Protection
This unit is equipped with "brownout" protection. In case of an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the line voltage reaches at least 100 VAC, the control will re-
energize your unit.
Note: A compressor lockout will occur after the unit is re- energized.
WARNING
To avoid death, personal inju ry or property damage due to electrical shock, do not use
an extension cord. Do not pinch the power cord. Do not remove the warning tag from
the power cord.
Unit Plug Type Receptacle Circuit Rating, Voltage Rating
(_ 125V-15AMP 115V
NEMA No 5-15P NEMA No 5=15R
NEMA No 6-15P NEMA No 6-15R
NEMA No 6-20P NEMA No 6-20R
NEMA No 6-30P NEMA No 6-30R
Required Breaker or On Unit Nameplate
Time
Delay Fuse
250V-15AMP
250V-20AMP 12 amperes but not more
250V=30AMP
230/208V rated
at 12 amperes or less
230/208V rated over
than 16 ampf_res
230/208V rated
at 24 amperes or Eess
Table 1
,Digital Temperature Setting
- Temperature can be set from 60°F to 90°F in I°F
increments
,Digital Temperature Display
- Shows indoor room temperature in FAN ONLY
mode
- Shows desired temperature setting in other modes
,Computer Memory that Remembers
- The unit remembers the last settings used when
last turned on.
,TempAsure ®Thermostat
- Maintains set temperature within 1.5°F for maxi-
mum comfort
,Smart Cool ,Energy Saver with TempAsure ®air sampling
,Delay Timer
2
Operation
Vent Control
Open or close the vent by sliding the vent control lever to the appropriate setting.
EXHAUST - This setting opens the vent to move indoor air out.
Note: To conserve energy, the unit should be set to the FAN ONLY mode when using this setting.
CLOSED - In this position the vent is closed and room air is recirculated and filtered. This position should be used for all
normal cooling operations (see underlined cooling options on control panel).
Unit Control
ENERGY SAVER mode provides the most
ENERGY SAVER (HIGH, MED and LOW) -
energy efficient use of your room air condi-
tioner. In ENERGYSAVERmode, thefanstopswhenthe compressor stops cooling. This feature can be used with
SMART COOL or cooling with any fan speed.
Amana's new air sampling system works to maintain set
temperature within 1.5°F while in ENERGY SAVER mode.
Approximately every 5 minutes the fan will turn on and
"sample" the room air todetermine if cooling isneeded. Ifthe room is cool enough, the fan will cycle off. If the room needs
further cooling, the cornpressor will start along with the fan
until the set temperature is reached. ENERGY SAVER has a soft start fan feature. This feature
starts the fan in low speed to reduce noise.
FAN ONLY- FAN ONLY circulates room air at
the set fan speed without cooling. This feature can be turned off by pressing the FAN ONLY,
the SMART COOL, or the ENERGY SAVER button. Indoor temperature is displayed in FAN ONLY mode.
Control Panel
[_ OFF - Completely shuts off the unit.
SMART COOL- SMART COOL adjusts the
temperature. The SMART COOL feature uses
fan speed of the unit to achieve the selected computer logic to cool the room quickly and
quietly. The fan speed starts onhigh, automatically switches to medium, and finally goes to low as the room temperature
nears the set temperature.
__ LOW FAN, MED FAN, HIGH FAN
fan speed to cool. If FAN ONLY is selected these buttons change fan speed without cooling. Selecting the fan speed
starts normal cooling.
- These three buttons are used to select either a low, medium or high
SET Temperature - These key pads in-crease or decrease the set temperature.
of delaying the start up or shut down of the air
DELAY TIMER- This button provides ameans conditioner from 1to 24 hours from the present
time. After setting the delay timer, the displayed time will
countdown to unit start or stop, See next page for details,
[_ _ _sriogmhetnme:dAsdlU_stiFp/atybeght.
ness can be changed using the "up" or "down" keypad. To decrease brightness, simultaneously press and hold OFF
pad with "down" arrow. To increase brightness, simulta- neously press and hold OFF pad with "up" arrow.