Amana 10M52TA-P1214708R, 12M52TA-P1214709R, 12M52TB-P1230813R, 12M52TA-P1214712R, 10M52TB-P1230808R Owner’s Manual

Quiet Zone
Room Air Conditioner
Contents
Electrical Requirements ........................................ 2
Electrical Grounding Instructions .................................. 2
Safety Features ...................................................... 2
Advantages of Amana's Electronic Controls ....... 2
Operation ............................................................... 3
General Information .............................................. 6
Air Flow Around Unit ........................................................ 6
Care and Maintenance .......................................... 6
Air Filter ........................................................................... 6
Before Calling For Service ................................... 7
Fan Motor ......................................................................... 7
Slide out Chassis ............................................................ 7
Model Identification ............................................. 8
Any Questions? ...................................................... 8
50
Use And Care
Manual
Please read this Use and Care Manual thoroughly. This
manual provides proper maintenance information for maxi- mum benefit of the features selected.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
I_= _k WARNING
To avoid death, personal injury or property damage due to overheating, do
not leave this room air conditioner unattended when used as cooling or life
support for persons or animals unable to react to unit failure. Take precautions to
warn or guard against such an
occurrence.
Electrical Requirements
Electrical Grounding Instructions
This appliance is equipped with a three-prong grounding plug for protection against possible shock hazards. Ifa two-
prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-
prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National
Electrical Code. Room air conditioners are designed to operate according to
requirements on the nameplate and as shown in Figure 1. Fuse or circuit breaker ratings must be according to the
fuse instruction label and as shown in Figure 1. Do not plug models marked "Use on Single Outlet Circuit Only" into a circuit with another appliance or light fixture.
I_k WARNING
To avoid death, personal injury or property damage due to electrical shock, this unit must be grounded. Do not under any
circumstances cut or remove the round grounding prong from the plug. Do not
use a two-prong adapter.
Safety Features
This room air conditioner is equipped with an electronic control to improve comfort and ensure reliability.
CompressorLockout
To extend the life of the compressor a three minute time delay will occur when:
Electrical power is first supplied to the unit
The thermostat isturned down immediately after the compressor stops running.
The Fan Control isquicklyturned from FAN ONLY to COOLING mode or vice versa.
Low Voltage Protection
This unit isequipped with "brownout" protection. Incase of an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the line voltage reaches at least 180 VAC, the control will re-
energize your unit.
Note: A compressor lockout will occur after the unit is
re-energized.
[-- _ WARNING
To avoid death, personal injury or property damage due to electrical shock, do not
use an extension cord. Do not pinch the power cord. Do not remove the warning
tag from the power cord.
RECEPTACLE PLUG
250 V- 16 AMP
Digital Temperature Setting
Temperature can be set from 16°C to 32°C in 1°C increments
Digital Temperature Display
Shows indoor room temperature in FAN ONLY mode
Shows desired temperature setting in other modes
Computer Memory that Remembers
The unit remembers the last settings used when last turned on.
TempAsure _ Thermostat
Maintains set temperature within 1,0°C for maxi- mum comfort
Smart Cool
Figure 1
Energy Saver with TempAsure _ air sampling
Delay Timer
Operation
Vent Control
Open or close the vent by sliding thevent control leverto the appropriate setting.
EXHAUST- This setting opens the vent to move indoor air
out.
Note: To conserve energy, the unit should be set to the
FAN ONL Ymode when using this setting.
CLOSED - In this position the vent is closed and room air is recirculated and filtered. This position should be used for
all normal cooling operations (see underlined cooling op- tions on control panel).
ENERGY SAVER mode provides the most
ENERGYSAVER (HIGH, MED and LOW)-
energy efficient use of your room air condi-
tioner. I n ENERGY SAVER mode, thefan stopswhen the
compressor stops cooling. This feature can be used with SMART COOL or cooling with any fan speed.
Amana's new air sampling system works to maintain set temperaturewithin 1.5°Fwhile inENERGY SAVER mode.
Approximately every 5 minutes the fan will turn on and "sample" the room airto determine ifcooling is needed. If
the room is cool enough, the fan will cycle off. If the room
needs further cooling, the compressor will start along with
the fan until the set temperature is reached.
ENERGY SAVER has a soft start fan feature. This feature
starts the fan in low speed to reduce noise.
FAN ONLY - FAN ONLY circulates room airat the set fan speed without cooling. This
feature can be turned off by pressing the FAN
ONLY, the SMART COOL, orthe ENERGY SAVER button. Indoor temperature is displayed in FAN ONLY mode.
Unit Control
Control Panel
OFF - Completely shuts off the unit.
SMART COOL- SMART COOL adjusts the
fan speed of the unit to achieve the selected
temperature. The SMART COOL feature uses computer logic to cool the room quickly
and quietly. The fan speed starts on high, automatically switches to medium, and finally goes to low as the room
temperature nears the set temperature.
___ LOW FAN, MED FAN, HIGH FAN
high fan speed to cool. If FAN ONLY is selected these buttons change fan speed without cooling. Selecting the fan speed starts normal cooling.
- These three buttons are used to select either a low, medium or
_-_ SET_ SET Temperature - These key pads _d;enCrease or decrease the set tempera-
DELAY TIMER - This button provides a
means of delaying the start up or shut down
of the air conditioner from 1 to 24 hours from the present time. After setting the delay timer, the displayed time will
countdown to unit start or stop. See next page for details.