Vent Control ..................................................................... 3
Unit Control ...................................................................... 3
General Information .............................................. 6
Changing Air Flow Direction ........................................... 6
Air Flow Around Unit........................................................ 6
Care and Maintenance .......................................... 6
Air Filter ........................................................................... 6
Before Calling For Service ................................... 7
Fan Motor ......................................................................... 7
Slide out Chassis ............................................................ 7
Model Identification ............................................. 8
Any Questions? ......................................................8
50 Hz
Use And Care
Manual
Please read this Use and Care Manual thoroughly. This
manual provides proper maintenance information for maximum benefit of the features selected.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
WARNING
To avoid death, personal injury or
property damage due to overheating, do
not leave this room air conditioner
unattended when used as cooling or life
support for persons or animals unable to
react to unit failure. Take precautions to
warn or guard against such an
occurrence.
Electrical Requirements
Electrical Grounding Instructions
This appliance is equipped with a three-prong grounding
plug for protection against possible shock hazards. If a twoprong wall receptacle is encountered, the customer is
required to contact a qualified electrician and have the twoprong wall receptacle replaced with a properly grounded
three-prong wall receptacle in accordance with the National
Electrical Code.
Room air conditioners are designed to operate according to
requirements on the nameplate and as shown in Figure 1.
Fuse or circuit breaker ratings must be according to the
fuse instruction label and as shown in Figure 1. Do not plug
models marked “Use on Single Outlet Circuit Only” into a
circuit with another appliance or light fixture.
WARNING
To avoid death, personal injury or property
damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not
use a two-prong adapter.
Safety Features
This room air conditioner is equipped with an electronic
control to improve comfort and ensure reliability.
Compressor Lockout
To extend the life of the compressor a three minute time
delay will occur when:
•Electrical power is first supplied to the unit
•The thermostat is turned down immediately after the
compressor stops running.
•The Fan Control is quickly turned from FAN ONLY to
COOLING mode or vice versa.
Low Voltage Protection
This unit is equipped with “brownout” protection. In case of
an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the
line voltage reaches at least 180 VAC, the control will reenergize your unit.
Note: A compressor lockout will occur after the unit is
re-energized.
WARNING
To avoid death, personal injury or property
damage due to electrical shock, do not
use an extension cord. Do not pinch the
power cord. Do not remove the warning
tag from the power cord.
RECEPTACLE
250
- 16
V
Figure 1
AMP
PLUG
Advantages of Amana’s Electronic
Controls
•Digital Temperature Setting
- Temperature can be set from 16°C to 32°C in 1°C
increments
•Digital Temperature Display
- Shows indoor room temperature in FAN ONLY
mode
- Shows desired temperature setting in other modes
•Computer Memory that Remembers
- The unit remembers the last settings used when
last turned on.
•TempAsure® Thermostat
- Maintains set temperature within 1.0°C for maxi-
mum comfort
•Smart Cool
•Energy Saver with TempAsure® air sampling
•Delay Timer
2
Operation
Vent Control
QUIET ZONE
EXHAUST CLOSED
Open or close the vent by sliding the vent control lever to the
appropriate setting.
EXHAUST - This setting opens the vent to move indoor air
out.
Note: To conserve energy, the unit should be set to the
FAN ONLY mode when using this setting.
CLOSED - In this position the vent is closed and room air
is recirculated and filtered. This position should be used for
all normal cooling operations (see underlined cooling options on control panel).
Unit Control
ENERGY SAVER (HIGH, MED and LOW) -
ENERGY SAVER mode provides the most
energy efficient use of your room air conditioner. I nENERGY SAVER mode, the fan stops when the
compressor stops cooling. This feature can be used with
SMART COOL or cooling with any fan speed.
Amana’s new air sampling system works to maintain set
temperature within 1.5°F while in ENERGY SAVER mode.
Approximately every 5 minutes the fan will turn on and
“sample” the room air to determine if cooling is needed. If
the room is cool enough, the fan will cycle off. If the room
needs further cooling, the compressor will start along with
the fan until the set temperature is reached.
ENERGY SAVER has a soft start fan feature. This feature
starts the fan in low speed to reduce noise.
FAN ONLY - FAN ONLY circulates room air
at the set fan speed without cooling. This
feature can be turned off by pressing the FAN
ONLY, the SMART COOL, or the ENERGY SAVER button.
Indoor temperature is displayed in FAN ONLY mode.
SM ART
LOW
ME D
HIGH
ENERG Y
OFF
COOL
FAN
COOLING
COOLING
FAN
FAN
SAVER
FAN
ON LY
SET
Control Panel
OFF - Completely shuts off the unit.
SMART COOL - SMART COOL adjusts the
fan speed of the unit to achieve the selected
temperature. The SMART COOL feature
uses computer logic to cool the room quickly
and quietly. The fan speed starts on high, automatically
switches to medium, and finally goes to low as the room
temperature nears the set temperature.
LOW FAN, MED FAN, HIGH FAN
- These three buttons are used to
select either a low, medium or
high fan speed to cool. If FAN ONLY is selected these
buttons change fan speed without cooling. Selecting the
fan speed starts normal cooling.
DELAY
22
TIMER
QUIET ZONE
QUIET ZONE
EXHAUST CLOSED
EXHAUST CLOSED
SET Temperature - These key pads
increase or decrease the set tempera-
ture.
DELAY TIMER - This button provides a
means of delaying the start up or shut down
of the air conditioner from 1 to 24 hours from the present
time. After setting the delay timer, the displayed time will
countdown to unit start or stop. See next page for details.
3