WPTV248UL Series
CCTV Outdoor Power Supplies
Installation Guide
Models Include:
• WPTV248UL • WPTV248ULCB
- 24VAC @ 3.5 amp (85VA). - 24VAC @ 3.5 amp (85VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• WPTV248175UL • WPTV248175ULCB
- 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA). or 28VAC @ 6.25 amp (175VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• WPTV248300UL • WPTV248300ULCB
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
Rev
. 021104
Overview:
These outdoor Altronix CCTV Power Supplies provide power via eight (8) fused or PTC protected outputs for CCTV
Cameras, heaters and other video accessories. Units are UL Listed UL2044 “
U.S. and Canada for CCTV Equipment.”
Eight (8) Output WPTV Reference Chart:
wer limited)
Altronix
Model Number
WPTV248UL 24VAC 3.5 amp 8 - x 3.5 amp 3.5 amp/250V .9 amp
WPTV248ULCB 24VAC 3.5 amp 8 x - 2.5 amp - .9 amp
WPTV248175UL
WPTV248175ULCB
WPTV248300UL
Output Voltage
24VAC 7 amp
28VAC 6.25 amp
24VAC 7 amp
28VAC 6.25 amp
24VAC 12.5 amp
28VAC 10 amp
(Power)
Total Output Current
Outputs
Number of
8 - x 3.5 amp - 1.76 amp
8 x - 2.5 amp - 1.76 amp
8 - x 3.5 amp - 2.7 amp
PTC Protected Outputs
(Class 2 po
Outputs
Fuse Protected
(max per output)
Output Current
Main Fuse Ratings
on Board
115VAC
50/60Hz Input
Current
24VAC 12.5 amp
WPTV248300ULCB
28VAC 10 amp
8 x - 2.5 amp - 2.7 amp
Specifications:
• UL Listed for Commercial CCTV Equipment (UL2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch / circuit-breaker.
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions:
12"H x 8"W x 6"D
Installation Instructions:
1. Mount unit in desired location. Use hardware supplied and stainless steel fasteners.
2. Slide switch on PD board to OFF position for models WPTV248UL and WPTV248ULCB
n OFF main s
ur
T
All units are f
3.
For 28VAC operation (for models with 24VAC/28VAC option only), adjust unit prior to mounting and applying
power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
ellow wire [24V] is connected to the terminal marked [S].
the y
4. Before drilling WP enclosure for wire entry, remove back plate (four (4) screws) with all internal parts
(Fig. 2A, pg. 5). For suggested wire entry locations refer to (Fig. 1, pg. 4). Use weather tight NEMA 4 rated
connectors, bushings, and cables.
5. Place back plate with all internal parts (four (4) screws) back into WP enclosure
6. Connect AC po
to earth ground. Use 18 AWG or larger for all power connections.
Keep power limited (PTC protected outputs only) wiring separate from non-power limited wiring.
Minimum .25” spacing m
7. Measure output voltage before connecting devices. This helps avoid potential damage.
Terminals marked [1P - 8P] are of the same polarity.
witch on all other models
C operation.
y set for 24V
actor
wer to the black and white flying leads of the transformer(s) (Figs. 2-4, pgs. 5-7)
A
ust be pr
vided. Use separate entries.
o
igs. 3-4, pgs. 6-7).
(F
- 2 -
ig. 2A, pg. 5).
(F
(Fig. 2, pg. 5).
, secure g
reen lead
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output v
8.
Connect devices to terminals marked [1P - 1N through 8P - 8N] on PD8/PD8CB board (Figs. 2-4, pgs. 5-7),
carefull
9. Slide switch on PD board to ON position for models WPTV248UL and WPTV248ULCB
Turn main switch on all other models to the ON (RESET) position
oltage.
y observing polarity.
(Fig. 2, pg. 5).
(Figs. 3-4, pgs. 6-7).
10. Green LED will illuminate when unit is powered.
11. Upon completion of wiring, secure enclosure door with the cam lock (supplied).
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: This installation should be made by qualified service personnel. Unit should be installed in
accordance with the National Electrical Codes and all local codes. For continued protection against risk
of fire replace all fuses only with the same type and rating
(3.5 amp/250VAC).
Terminal Identification:
PD8 - Power Distribution Module
1P - 8P AC output.
1N - 8N AC output.
- 3 -